906 resultados para Speech in Noise


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the speech in subjects with cleft lip and palate, in whom three methods of the hard palate closure were used. One hundred and thirty-seven children (96 boys, 41 girls; mean age = 12 years, SD = 1·2) with complete unilateral cleft lip and palate (CUCLP) operated by a single surgeon with a one-stage method were evaluated. The management of the cleft lip and soft palate was comparable in all subjects; for hard palate repair, three different methods were used: bilateral von Langenbeck closure (b-vL group, n = 39), unilateral von Langenbeck closure (u-vL group, n = 56) and vomerplasty (v-p group, n = 42). Speech was assessed: (i) perceptually for the presence of a) hypernasality, b) compensatory articulations (CAs), c) audible nasal air emissions (ANE) and d) speech intelligibility; (ii) for the presence of compensatory facial grimacing, (iii) with clinical intra-oral evaluation and (iv) with videonasendoscopy. A total rate of hypernasality requiring pharyngoplasty was 5·1%; total incidence post-oral compensatory articulations (CAs) was 2·2%. The overall speech intelligibility was good in 84·7% of cases. Oronasal fistulas (ONFs) occurred in 15·7% b-vL subjects, 7·1% u-vL subjects and 50% v-p subjects (P < 0·001). No statistically significant intergroup differences for hypernasality, CAs and intelligibility were found (P > 0·1). In conclusion, the speech after early one-stage repair of CUCLP was satisfactory. The method of hard palate repair affected the incidence of ONFs, which, however, caused relatively mild and inconsistent speech errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct), aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conclusion Using a second bone anchored hearing implant (BAHI) mounted on a testband in unilaterally implanted BAHI users to test its potential advantage pre-operatively under-estimates the advantage of two BAHIs placed on two implants. Objectives To investigate how well speech understanding with a second BAHI mounted on a testband approaches the benefit of bilaterally implanted BAHIs. Method Prospective study with 16 BAHI users. Eight were implanted unilaterally (group A) and eight were implanted bilaterally (group B). Aided speech understanding was measured. Speech was presented from the front and noise came either from the left, right, or from the front in two conditions for group A (with one BAHI, and with two BAHIs, where the second device was mounted on a testband) and in three conditions for group B (same two conditions as group A, and in addition with both BAHIs mounted on implants). Results Speech understanding in noise improved with the additional device for noise from the side of the first BAHI (+0.7 to +2.1 dB) and decreased for noise from the other side (-1.8 dB to -3.9 dB). Improvements were highest (+2.1 dB, p = 0.016) and disadvantages were smallest (-1.8 dB, p = 0.047) with both BAHIs mounted on implants. Testbands yielded smaller advantages and higher disadvantages of the additional BAHI (average difference = -0.9 dB).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. Loud noises in neonatal intensive care units (NICUs) may impede growth and development for extremely low birthweight (ELBW, < 1000 grams) newborns. The objective of this study was to measure the association between NICU sound levels and ELBW neonates' arterial blood pressure to determine whether these newborns experience noise-induced stress. ^ Methods. Noise and arterial blood pressure recordings were collected for 9 ELBW neonates during the first week of life. Sound levels were measured inside the incubator, and each subject's arterial blood pressures were simultaneously recorded for 15 minutes (at 1 sec intervals). Time series cross-correlation functions were calculated for NICU noise and mean arterial blood pressure (MABP) recordings for each subject. The grand mean noise-MABP cross-correlation was calculated for all subjects and for lower and higher birthweight groups for comparison. ^ Results. The grand mean noise-MABP cross-correlation for all subjects was mostly negative (through 300 sec lag time) and nearly reached significance at the 95% level at 111 sec lag (mean r = -0.062). Lower birthweight newborns (454-709 g) experienced significant decreases in blood pressure with increasing NICU noise after 145 sec lag (peak r = -0.074). Higher birthweight newborns had an immediate negative correlation with NICU sound levels (at 3 sec lag, r = -0.071), but arterial blood pressures increased to a positive correlation with noise levels at 197 sec lag (r = 0.075). ^ Conclusions. ELBW newborns' arterial blood pressure was influenced by NICU noise levels during the first week of life. Lower birthweight newborns may have experienced an orienting reflex to NICU sounds. Higher birthweight newborns experienced an immediate orienting reflex to increasing sound levels, but arterial blood pressure increased approximately 3 minutes after increases in noise levels. Increases in arterial blood pressure following increased NICU sound levels may result from a stress response to noise. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The introduction of open-plan offices in the 1960s with the intent of making the workplace more flexible, efficient, and team-oriented resulted in a higher noise floor level, which not only made concentrated work more difficult, but also caused physiological problems, such as increased stress, in addition to a loss of speech privacy. Irrelevant background human speech, in particular, has proven to be a major factor in disrupting concentration and lowering performance. Therefore, reducing the intelligibility of speech and has been a goal of increasing importance in recent years. One method employed to do so is the use of masking noises, which consists in emitting a continuous noise signal over a loudspeaker system that conceals the perturbing speech. Studies have shown that while effective, the maskers employed to date – normally filtered pink noise – are generally poorly accepted by users. The collaborative "Private Workspace" project, within the scope of which this thesis was carried out, attempts to develop a coupled, adaptive noise masking system along with a physical structure to be used for open-plan offices so as to combat these issues. There is evidence to suggest that nature sounds might be more accepted as masker, in part because they can have a visual object that acts as the source for the sound. Direct audio recordings are not recommended for various reasons, and thus the nature sounds must be synthesized. This work done consists of the synthesis of a sound texture to be used as a masker as well as its evaluation. The sound texture is composed of two parts: a wind-like noise synthesized with subtractive synthesis, and a leaf-like noise synthesized through granular synthesis. Different combinations of these two noises produced five variations of the masker, which were evaluated at different levels along with white noise and pink noise using a modified version of an Oldenburger Satztest to test for an affect on speech intelligibility and a questionnaire to asses its subjective acceptance. The goal was to find which of the synthesized noises works best as a speech masker. This thesis first uses a theoretical introduction to establish the basics of sound perception, psychoacoustic masking, and sound texture synthesis. The design of each of the noises, as well as their respective implementations in MATLAB, is explained, followed by the procedures used to evaluate the maskers. The results obtained in the evaluation are analyzed. Lastly, conclusions are drawn and future work is and modifications to the masker are proposed. RESUMEN. La introducción de las oficinas abiertas en los años 60 tenía como objeto flexibilizar el ambiente laboral, hacerlo más eficiente y que estuviera más orientado al trabajo en equipo. Como consecuencia, subió el nivel de ruido de fondo, que no sólo dificulta la concentración, sino que causa problemas fisiológicos, como el aumento del estrés, además de reducir la privacidad. Hay estudios que prueban que las conversaciones de fondo en particular tienen un efecto negativo en el nivel de concentración y disminuyen el rendimiento de los trabajadores. Por lo tanto, reducir la inteligibilidad del habla es uno de los principales objetivos en la actualidad. Un método empleado para hacerlo ha sido el uso de ruido enmascarante, que consiste en reproducir señales continuas de ruido a través de un sistema de altavoces que enmascare el habla. Aunque diversos estudios demuestran que es un método eficaz, los ruidos utilizados hasta la fecha (normalmente ruido rosa filtrado), no son muy bien aceptados por los usuarios. El proyecto colaborativo "Private Workspace", dentro del cual se engloba el trabajo realizado en este Proyecto Fin de Grado, tiene por objeto desarrollar un sistema de ruido enmascarador acoplado y adaptativo, además de una estructura física, para su uso en oficinas abiertas con el fin de combatir los problemas descritos anteriormente. Existen indicios de que los sonidos naturales son mejor aceptados, en parte porque pueden tener una estructura física que simule ser la fuente de los mismos. La utilización de grabaciones directas de estos sonidos no está recomendada por varios motivos, y por lo tanto los sonidos naturales deben ser sintetizados. El presente trabajo consiste en la síntesis de una textura de sonido (en inglés sound texture) para ser usada como ruido enmascarador, además de su evaluación. La textura está compuesta de dos partes: un sonido de viento sintetizado mediante síntesis sustractiva y un sonido de hojas sintetizado mediante síntesis granular. Diferentes combinaciones de estos dos sonidos producen cinco variaciones de ruido enmascarador. Estos cinco ruidos han sido evaluados a diferentes niveles, junto con ruido blanco y ruido rosa, mediante una versión modificada de un Oldenburger Satztest para comprobar cómo afectan a la inteligibilidad del habla, y mediante un cuestionario para una evaluación subjetiva de su aceptación. El objetivo era encontrar qué ruido de los que se han sintetizado funciona mejor como enmascarador del habla. El proyecto consiste en una introducción teórica que establece las bases de la percepción del sonido, el enmascaramiento psicoacústico, y la síntesis de texturas de sonido. Se explica a continuación el diseño de cada uno de los ruidos, así como su implementación en MATLAB. Posteriormente se detallan los procedimientos empleados para evaluarlos. Los resultados obtenidos se analizan y se extraen conclusiones. Por último, se propone un posible trabajo futuro y mejoras al ruido sintetizado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Repetitions in child-directed speech (CDS) have been shown to vary over time, and are suggested to affect first language acquisition. Correlations between verbal contents of repetitions in CDS and children’s language development have been suggested. The verbal contents of repetitions in Swedish CDS have not yet been investigated. The aim of this study was to examine the verbal contents of repetitions in Swedish CDS during the child’s first 2 years and possible changes in proportions of repetitions during the same time span. Verbal contents of repetitions in parents’ speech in 10 parent-child dyads as the children were 3, 6, 9, 12 and 24 months old were investigated focusing on word classes, sentence types and whole-constituent change. The results were compared to the children’s productive vocabularies at the age of 30 months. Possible occurrences of item-based constructions and frequent frames in the repetitions were also examined. The overall results revealed patterns concerning change in verbal contents in repetitions over time and correlations between verbal contents in repetitions and child language development. Two proposals were made: parents adjust the complexity of their speech to linguistic developmental stages of their children, and linguistic variation in the input increases as the child grows older.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrastdiscrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3 c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224--1243.] was `lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis describes work undertaken in order to fulfil a need experienced in the Department of Educational Enquiry at the University of Aston in Birmingham for speech analysis facilities suitable for use in teaching and research work within the Department. The hardware and software developed during the research project provides displays of speech fundamental frequency and intensity in real time. The system is suitable for the provision of visual feedback of these parameters of a subject's speech in a learning situation, and overcomes the inadequacies of equipment currently used for this task in that it provides a clear indication of fundamental frequency contours as the subject is speaking. The thesis considers the use of such equipment in several related fields, and the approaches that have been reported to one of the major problems of speech analysis, namely pitch-period estimation. A number of different systems are described, and their suitability for the present purposes is discussed. Finally, a novel method of pitch-period estimation is developed, and a speech analysis system incorporating this method is described. Comparison is made between the results produced by this system and those produced by a conventional speech spectrograph.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work described in this thesis is directed towards the reduction of noise levels in the Hoover Turbopower upright vacuum cleaner. The experimental work embodies a study of such factors as the application of noise source identification techniques, investigation of the noise generating principles for each major source and evaluation of the noise reducing treatments. It was found that the design of the vacuum cleaner had not been optimised from the standpoint of noise emission. Important factors such as noise `windows', isolation of vibration at the source, panel rattle, resonances and critical speeds had not been considered. Therefore, a number of experimentally validated treatments are proposed. Their noise reduction benefit together with material and tooling costs are presented. The solutions to the noise problems were evaluated on a standard Turbopower and the sound power level of the cleaner was reduced from 87.5 dB(A) to 80.4 db(A) at a cost of 93.6 pence per cleaner.The designers' lack of experience in noise reduction was identified as one of the factors for the low priority given to noise during design of the cleaner. Consequently, the fundamentals of acoustics, principles of noise prediction and absorption and guidelines for good acoustical design were collated into a Handbook and circulated at Hoover plc.Mechanical variations during production of the motor and the cleaner were found to be important. These caused a vast spread in the noise levels of the cleaners. Subsequently, the manufacturing processes were briefly studied to identify their source and recommendations for improvement are made.Noise of a product is quality related and a high level of noise is considered to be a bad feature. This project suggested that the noise level be used constructively both as a test on the production line to identify cleaners above a certain noise level and also to promote the product by `designing' the characteristics of the sound so that the appliance is pleasant to the user. This project showed that good noise control principles should be implemented early in the design stage.As yet there are no mandatory noise limits or noise-labelling requirements for household appliances. However, the literature suggests that noise-labelling is likely in the near future and the requirement will be to display the A-weighted sound power level. However, the `noys' scale of perceived noisiness was found more appropriate to the rating of appliance noise both as it is linear and therefore, a sound level that seems twice as loud is twice the value in noys and also takes into consideration the presence of pure tones, which even in the absence of a high noise level can lead to annoyance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The deliberate addition of Gaussian noise to cochlear implant signals has previously been proposed to enhance the time coding of signals by the cochlear nerve. Potentially, the addition of an inaudible level of noise could also have secondary benefits: it could lower the threshold to the information-bearing signal, and by desynchronization of nerve discharges, it could increase the level at which the information-bearing signal becomes uncomfortable. Both these effects would lead to an increased dynamic range, which might be expected to enhance speech comprehension and make the choice of cochlear implant compression parameters less critical (as with a wider dynamic range, small changes in the parameters would have less effect on loudness). The hypothesized secondary effects were investigated with eight users of the Clarion cochlear implant; the stimulation was analogue and monopolar. For presentations in noise, noise at 95% of the threshold level was applied simultaneously and independently to all the electrodes. The noise was found in two-alternative forced-choice (2AFC) experiments to decrease the threshold to sinusoidal stimuli (100 Hz, 1 kHz, 5 kHz) by about 2.0 dB and increase the dynamic range by 0.7 dB. Furthermore, in 2AFC loudness balance experiments, noise was found to decrease the loudness of moderate to intense stimuli. This suggests that loudness is partially coded by the degree of phase-locking of cochlear nerve fibers. The overall gain in dynamic range was modest, and more complex noise strategies, for example, using inhibition between the noise sources, may be required to get a clinically useful benefit. © 2006 Association for Research in Otolaryngology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple but efficient voice activity detector based on the Hilbert transform and a dynamic threshold is presented to be used on the pre-processing of audio signals -- The algorithm to define the dynamic threshold is a modification of a convex combination found in literature -- This scheme allows the detection of prosodic and silence segments on a speech in presence of non-ideal conditions like a spectral overlapped noise -- The present work shows preliminary results over a database built with some political speech -- The tests were performed adding artificial noise to natural noises over the audio signals, and some algorithms are compared -- Results will be extrapolated to the field of adaptive filtering on monophonic signals and the analysis of speech pathologies on futures works

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of ICT infrastructures has facilitated the emergence of new paradigms for looking at society and the environment over the last few years. Participatory environmental sensing, i.e. directly involving citizens in environmental monitoring, is one example, which is hoped to encourage learning and enhance awareness of environmental issues. In this paper, an analysis of the behaviour of individuals involved in noise sensing is presented. Citizens have been involved in noise measuring activities through the WideNoise smartphone application. This application has been designed to record both objective (noise samples) and subjective (opinions, feelings) data. The application has been open to be used freely by anyone and has been widely employed worldwide. In addition, several test cases have been organised in European countries. Based on the information submitted by users, an analysis of emerging awareness and learning is performed. The data show that changes in the way the environment is perceived after repeated usage of the application do appear. Specifically, users learn how to recognise different noise levels they are exposed to. Additionally, the subjective data collected indicate an increased user involvement in time and a categorisation effect between pleasant and less pleasant environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early intervention is the key to spoken language for hearing impaired children. A severe hearing loss diagnosis in young children raises the urgent question on the optimal type of hearing aid device. As there is no recent data on comparing selection criteria for a specific hearing aid device, the goal of the Hearing Evaluation of Auditory Rehabilitation Devices (hEARd) project (Coninx & Vermeulen, 2012) evolved to collect and analyze interlingually comparable normative data on the speech perception performances of children with hearing aids and children with cochlear implants (CI). METHOD: In various institutions for hearing rehabilitation in Belgium, Germany and the Netherlands the Adaptive Auditory Speech Test AAST was used in the hEARd project, to determine speech perception abilities in kindergarten and school aged hearing impaired children. Results in the speech audiometric procedures were matched to the unaided hearing loss values of children using hearing aids and compared to results of children using CI. 277 data sets of hearing impaired children were analyzed. Results of children using hearing aids were summarized in groups as to their unaided hearing loss values. The grouping was related to the World Health Organization’s (WHO) grading of hearing impairment from mild (25–40 dB HL) to moderate (41–60 dB HL), severe (61-80 dB HL) and profound hearing impairment (80 dB HL and higher). RESULTS: AAST speech recognition results in quiet showed a significantly better performance for the CI group in comparison to the group of profoundly impaired hearing aid users as well as the group of severely impaired hearing aid users. However the CI users’ performances in speech perception in noise did not vary from the hearing aid users’ performances. Within the collected data analyses showed that children with a CI show an equivalent performance on speech perception in quiet as children using hearing aids with a “moderate” hearing impairment.