901 resultados para Self-weight Consolidation
Resumo:
The rheological properties of block co-polymers in water solution at different pH have been investigated. The block copolymers are based on different architectures containing poly(ethylene glycol), poly(propylene glycol) and different blocks of polymer that change their hydrophobic/hydrophilic behavior as a function of pH. The polymer chains of the starting material were extended at their functional ends with the pH-sensitive units using ATRP; this mechanism of controlled radical polymerization was chosen because of the need to minimize polydispersity and avoid transfer reactions possibly leading to homopolymeric inpurities. The starting material were modified in order to use them as macroinitiator for ATRP. The kinetic of each ATRP reaction has been investigated, in order to be able to synthesize polymers with different degree of polymerization, stopping the reaction when the desired polymers chain length has been reached. We will use polymer chains with different basicity and degree of polymerization to link any possible effect of their presence to the conditions under which they become hydrophobic. It has been shown that the rate of polymerization changes changing the type of macroinitiator and the type of monomer synthesized. The slowest rate of polymerization is the one with the most hindered monomer synthesized using the macroinitiator with the highest molecular weight. The water solubility of the synthesized polymers changes depending on the pH of the solution and on the structure of the polymers. It has been shown using 1H-NMR that some of the synthesized polymers are capable to self-aggregation in water solution. The self-aggregation and the type of aggregation is influenced from the structure of the polymer and from the pH of the solution. Changing the structure of the polymers and the pH it is possible to obtain different type of aggregates in solution. This aggregates differ for the volume occupied from them, and for their hardness. Rheological measurements have been demonstrated that the synthesized polymers are capable to form gel phases. The gelation temperature changes changing the structure of the aggregates in solution and it is possible to correlate the changing in the gelation temperature with the changing in the structure of the polymer.
Resumo:
In der vorliegenden Arbeit wurden Materialien und Aufbauten für Hybrid Solarzellen entwickelt und erforscht. rnDer Vergleich zweier bekannter Lochleitermaterialien für Solarzellen in einfachen Blend-Systemen brachte sowohl Einsicht zur unterschiedlichen Eignung der Materialien für optoelektronische Bauelemente als auch neue Erkenntnisse in Bereichen der Langzeitstabilität und Luftempfindlichkeit beider Materialien.rnWeiterhin wurde eine Methode entwickelt, um Hybrid Solarzelle auf möglichst unkomplizierte Weise aus kostengünstigen Materialien darzustellen. Die „Eintopf“-Synthese ermöglicht die unkomplizierte Darstellung eines funktionalen Hybridmaterials für die optoelektronische Anwendung. Mithilfe eines neu entwickelten amphiphilen Blockcopolymers, das als funktionelles Templat eingesetzt wurde, konnten mit einem TiO2-Precursor in einem Sol-Gel Ansatz verschiedene selbstorganisierte Morphologien des Hybridmaterials erhalten werden. Verschiedene Morphologien wurden auf ihre Eignung in Hybrid Solarzellen untersucht. Ob und warum die Morphologie des Hybridsystems die Effizienz der Solarzelle beeinflusst, konnte verdeutlicht werden. Mit der Weiterentwicklung der „Eintopf“-Synthese, durch den Austausch des TiO2-Precursors, konnte die Solarzelleneffizienz von 0.15 auf 0.4 % gesteigert werden. Weiterhin konnte die Übertragbarkeit des Systems durch den erfolgreichen Austausch des Halbleiters TiO¬2 mit ZnO bewiesen werden.rn
Resumo:
In this work self-assembling model systems in aqueous solution were studied. The systems contained charged polymers, polyelectrolytes, that were combined with oppositely charged counterions to build up supramolecular structures. With imaging, scattering and spectroscopic techniques it was investigated how the structure of building units influences the structure of their assemblies. Polyelectrolytes with different chemical structure, molecular weight and morphology were investigated. In addition to linear polyelectrolytes, semi-flexible cylindrical bottle-brush polymers that possess a defined cross-section and a relatively high persistence along the backbone were studied. The polyelectrolytes were combined with structural organic counterions having charge numbers one to four. Especially the self-assembly of polyelectrolytes with different tetravalent water-soluble porphyrins was studied. Porphyrins have a rigid aromatic structure that has a structural effect on their self-assembly behavior and through which porphyrins are capable of self-aggregation via π-π interaction. The main focus of the thesis is the self-assembly of cylindrical bottle-brush polyelectrolytes with tetravalent porphyrins. It was shown that the addition of porphyrins to oppositely charged brush molecules induces a hierarchical formation of stable nanoscale brush-porphyrin networks. The networks can be disconnected by addition of salt and single porphyrin-decoratedrncylindrical brush polymers are obtained. These two new morphologies, brush-porphyrin networks and porphyrin-decorated brush polymers, may have potential as functional materials with interesting mechanical and optical properties.
Resumo:
This work covers the synthesis of second-generation, ethylene glycol dendrons covalently linked to a surface anchor that contains two, three, or four catechol groups, the molecular assembly in aqueous buffer on titanium oxide surfaces, and the evaluation of the resistance of the monomolecular adlayers against nonspecific protein adsorption in contact with full blood serum. The results were compared to those of a linear poly(ethylene glycol) (PEG) analogue with the same molecular weight. The adsorption kinetics as well as resulting surface coverages were monitored by ex situ spectroscopic ellipsometry (VASE), in situ optical waveguide lightmode spectroscopy (OWLS), and quartz crystal microbalance with dissipation (QCM-D) investigations. The expected compositions of the macromolecular films were verified by X-ray photoelectron spectroscopy (XPS). The results of the adsorption study, performed in a high ionic strength ("cloud-point") buffer at room temperature, demonstrate that the adsorption kinetics increase with increasing number of catechol binding moieties and exceed the values found for the linear PEG analogue. This is attributed to the comparatively smaller and more confined molecular volume of the dendritic macromolecules in solution, the improved presentation of the catechol anchor, and/or their much lower cloud-point in the chosen buffer (close to room temperature). Interestingly, in terms of mechanistic aspects of "nonfouling" surface properties, the dendron films were found to be much stiffer and considerably less hydrated in comparison to the linear PEG brush surface, closer in their physicochemical properties to oligo(ethylene glycol) alkanethiol self-assembled monolayers than to conventional brush surfaces. Despite these differences, both types of polymer architectures at saturation coverage proved to be highly resistant toward protein adsorption. Although associated with higher synthesis costs, dendritic macromolecules are considered to be an attractive alternative to linear polymers for surface (bio)functionalization in view of their spontaneous formation of ultrathin, confluent, and nonfouling monolayers at room temperature and their outstanding ability to present functional ligands (coupled to the termini of the dendritic structure) at high surface densities.
Resumo:
Electrochemical capacitors have been an important development in recent years in the field of energy storage. Capacitors can be developed by utilizing either double layer capacitance at the electrode/solution interfaces alone or in combination with a battery electrode associated with a faradic redox process in one electrode. An asymmetric capacitor consisting of electrochemically deposited nickel hydroxide, supported on carbon foam as a positive electrode and carbon sheet as a negative electrode has been successfully assembled and cycled. One objective of this study has been to demonstrate the viability of the nickel carbon foam positive electrode, especially in terms of cycle life. Electrochemical characterization shows stable, high cycle performance in 26 wt. % KOH electrolyte with a maximum energy density of 4.1 Wh/Kg and a relaxation time constant of 6.24 s. This cell has demonstrated high cycle life, 14,500 cycles, with efficiency better than 98%. In addition, the cell failure mechanism and self-discharge behavior of the aforesaid capacitor are analyzed.
Resumo:
BACKGROUND: Adults use the Internet for weight loss information, sometimes by participating in discussion forums. Our purpose was to analyze the quality of advice exchanged on these forums. METHODS: This was a retrospective analysis of messages posted to 18 Internet weight loss forums during 1 month in 2006. Advice was evaluated for congruence with clinical guidelines; potential for causing harm; and subsequent correction when it was contradictory to guidelines (erroneous) or potentially harmful. Message- and forum-specific characteristics were evaluated as predictors of advice quality and self-correction. RESULTS: Of 3368 initial messages, 266 (7.9%) were requests for advice. Of 654 provisions of advice, 56 (8.6%) were erroneous and 19 of these 56 (34%) were subsequently corrected. Forty-three (6.6%) provisions of advice were harmful, and 12 of these 43 (28%) were subsequently corrected. Messages from low-activity forums (fewer messages) were more likely than those from high-activity forums to be erroneous (10.6% vs 2.4%, P < .001) or harmful (8.4% vs 1.2%, P < .001). In high-activity forums, 2 of 4 (50%) erroneous provisions of advice and 2 of 2 (100%) potentially harmful provisions of advice were corrected by subsequent postings. Compared with general weight loss advice, medication-related advice was more likely to be erroneous (P = .02) or harmful (P = .01). CONCLUSIONS: Most advice posted on highly active Internet weight loss forums is not erroneous or harmful. However, clinical and research strategies are needed to address the quality of medication-related advice.
Resumo:
BACKGROUND: Adults use the Internet for weight loss information, sometimes by participating in discussion forums. Our purpose was to analyze the quality of advice exchanged on these forums. METHODS: This was a retrospective analysis of messages posted to 18 Internet weight loss forums during 1 month in 2006. Advice was evaluated for congruence with clinical guidelines; potential for causing harm; and subsequent correction when it was contradictory to guidelines (erroneous) or potentially harmful. Message- and forum-specific characteristics were evaluated as predictors of advice quality and self-correction. RESULTS: Of 3368 initial messages, 266 (7.9%) were requests for advice. Of 654 provisions of advice, 56 (8.6%) were erroneous and 19 of these 56 (34%) were subsequently corrected. Forty-three (6.6%) provisions of advice were harmful, and 12 of these 43 (28%) were subsequently corrected. Messages from low-activity forums (fewer messages) were more likely than those from high-activity forums to be erroneous (10.6% vs 2.4%, P < .001) or harmful (8.4% vs 1.2%, P < .001). In high-activity forums, 2 of 4 (50%) erroneous provisions of advice and 2 of 2 (100%) potentially harmful provisions of advice were corrected by subsequent postings. Compared with general weight loss advice, medication-related advice was more likely to be erroneous (P = .02) or harmful (P = .01). CONCLUSIONS: Most advice posted on highly active Internet weight loss forums is not erroneous or harmful. However, clinical and research strategies are needed to address the quality of medication-related advice.
Resumo:
Two studies investigated differences in the relationships between adolescents' fruit and vegetable intake (FVI) and the predictors specified in the Health Action Process Approach and Social-Cognitive Theory. Retrospective (Study 1; N = 502) and prospective (Study 2; N = 668) designs were applied. Among adolescents with overweight/obesity, intention was cross-sectionally associated with FVI (Study 1); no social or cognitive predictors explained FVI at 14-month follow-up (Study 2). The planning - FVI and self-efficacy - FVI relationships were stronger among adolescents who reduced their body weight to normal, compared to effects observed among those who maintained their body weight (Studies 1 and 2).
Resumo:
Background Research results from large, national population-based studies investigating gender differences in weight dissatisfaction and disordered eating across the adult life span are still limited. Gender is a significant factor in relation to weight dissatisfaction and disordered eating. However, the reasons for gender differences in these conditions are still poorly understood. The aim of this study was to examine gender differences in weight dissatisfaction and disordered eating in the general Swiss adult population and to identify gender-specific risk factors. Methods The study population consisted of 18156 Swiss adults who completed the population-based Swiss Health Survey 2007. Self-reported weight dissatisfaction, disordered eating and associated risk factors were assessed. In order to examine whether determinants of weight dissatisfaction and disordered eating (dieting to lose weight, binge eating, and irregular eating) differ in men and women, multivariate logistic regressions were applied separately for women and men. Results Although more men than women were overweight, more women than men reported weight dissatisfaction. Weight category, smoking status, education, and physical activity were significantly associated with weight dissatisfaction in men and women. In women, nationality and age were also significant factors. Gender-specific risk factors such as physical activity or weight category were identified for specific disordered eating behaviours. Conclusions The results suggest that gender specific associations between predictors and disordered eating behaviour should be considered in the development of effective prevention programs against disordered eating.
Resumo:
Social stressors at work (such as conflict or animosities) imply disrespect or a lack of appreciation and thus a threat to self. Stress induced by this offence to self might result, over time, in a change in body weight. The current study investigated the impact of changing working conditions--specifically social stressors, demands, and control at work--on women's change in weighted Body-Mass-Index over the course of a year. Fifty-seven women in their first year of occupational life participated at baseline and thirty-eight at follow-up. Working conditions were assessed by self-reports and observer-ratings. Body-Mass-Index at baseline and change in Body-Mass-Index one year later were regressed on self-reported social stressors as well as observed work stressors, observed job control, and their interaction. Seen individually, social stressors at work predicted Body-Mass-Index. Moreover, increase in social stressors and decrease of job control during the first year of occupational life predicted increase in Body-Mass-Index. Work redesign that reduces social stressors at work and increases job control could help to prevent obesity epidemic.
Resumo:
PRINCIPLES We aimed to evaluate the efficacy of, and treatment satisfaction with, insulin glargine administered with SoloSTAR® or ClikSTAR® pens in patients with type 2 diabetes mellitus managed by primary care physicians in Switzerland. METHODS A total of 327 patients with inadequately controlled type 2 diabetes were enrolled by 72 physicians in this prospective observational study, which aimed to evaluate the efficacy of a 6-month course of insulin glargine therapy measured as development of glycaemic control (glycosylated haemoglobin [HbA1c] and fasting plasma glucose [FPG]) and weight change. We also assessed preference for reusable or disposable pens, and treatment satisfaction. RESULTS After 6 months, the mean daily dose of insulin glargine was 27.7±14.3 U, and dose titration was completed in 228 (72.4%) patients. Mean HbA1c decreased from 8.9%±1.6% (n=327) to 7.3%±1.0% (n=315) (p<0.0001), and 138 (43.8%) patients achieved an HbA1c≤7.0%. Mean FPG decreased from 10.9±4.5 to 7.3±1.8 mmol/l (p<0.0001). Mean body weight did not change (85.4±17.2 kg vs 85.0±16.5 kg; p=0.11). Patients' preference was in favour of the disposable SoloStar® pen (80%), as compared with the reusable ClickStar® pen (20%). Overall, 92.6% of physicians and 96.3% of patients were satisfied or very satisfied with the insulin glargine therapy. CONCLUSIONS In patients with type 2 diabetes insulin glargine administered by SoloSTAR® or ClikSTAR® pens, education on insulin injection and on self-management of diabetes was associated with clinically meaningful improvements in HbA1c and FPG without a mean collective weight gain. The vast majority of both patients and primary care physicians were satisfied with the treatment intensification.
Resumo:
It is estimated that more than half the U.S. adult population is overweight or obese as classified by a body mass index of 25.0–29.9 or ≥30 kg/m 2, respectively. Since the current treatment approaches for long-term maintenance of weight loss are lacking, the National Institutes of Health state that an effective approach may be to focus on weight gain prevention. There is a limited body of literature describing how adults maintain a stable weight as they age. It is hypothesized that weight stability is the result of a balance between energy consumption and energy expenditure as influenced by diet, lifestyle, behavior, genetics and environment. The purpose of this research was to examine the dietary intake and behaviors, lifestyle habits, and risk factors for weight change that predict weight stability in a cohort of 2101 men and 389 women aged 20 to 8 7 years in the Aerobic Center Longitudinal Study regardless of body weight at baseline. At baseline, participants completed a maximal exercise treadmill test to determine cardiorespiratory fitness, a medical history questionnaire, which included self-reported measures of weight, dietary behaviors, lifestyle habits, and risk factors for weight change, a three-day diet record, and a mail-back version of the medical history questionnaire in 1990 or 1995. All analyses were performed separately for men and women. Results from multivariate regression analyses indicated that the strongest predictor of follow-up weight for men and women was previous weight, accounting for 87.0% and 81.9% of the variance, respectively. Age, length of follow-up and eating habits were also significant predictors of follow-up weight in men, though these variables only explained 3% of the variance. For women, length of follow-up and currently being on a diet were significantly associated with follow-up weight but these variables explained only an additional 2% of the variance. Understanding the factors that influence weight change has tremendous public health importance for developing effective methods to prevent weight gain. Since current weight was the strongest predictor of previous weight, preventing initial weight gain by maintaining a stable weight may be the most effective method to combat the increasing prevalence of overweight and obesity. ^
Resumo:
The purpose of this study was to assess the effect of maternal pre-pregnancy weight status on the relationship between prenatal smoking and infant birth weight (IBW). Prenatal cigarette smoking and maternal weight exert opposing effects on IBW; smoking decreases birth weight while maternal pre-pregnancy weight is positively correlated with birth weight. As such, mutual effect modification may be sufficiently significant to alter the independent effects of these two birth weight correlates. Finding of such an effect has implications of prenatal smoking cessation education. Perception of risk is an important determinant of smoking cessation, and reduced or low birth weight (LBW) as a smoking-associated risk predominates prenatal smoking counseling and education. In a population such as the US, where obesity is becoming epidemic, particularly among minority and low-income groups, perception of risk may be lowered should increased maternal size attenuate the effect of smoking. Previous studies have not found a significant interaction effect of prenatal smoking and maternal pre-pregnancy weight on IBW; however, use of self-reported smoking status may have biased findings. Reliability of self-reported smoking status reported in the literature is variable, with deception rates ranging from a low of 5% to as high as 16%. This study, using data from a prenatal smoking cessation project, in which smoking status was validated by saliva cotinine, was an opportunity to assess effect modification of smoking and maternal weight using biochemically determined smoking status in lieu of self report. Stratified by saliva cotinine, 151 women from a prenatal smoking cessation cohort, who were 18 years and older and had full-term, singleton births, were included in this study. The effect of smoking in terms of mean birth weight across three levels of maternal pre-pregnancy weight was assessed by general linear modeling procedures, adjusting for other known correlates of IBW. Effect modification was marginally significant, p = .104, but only with control for differential effects among racial/ethnic groups. A smaller than planned sample of nonsmokers, or women who quit smoking during the pregnancy, prohibited rejection of the null hypothesis of no difference in the effect of smoking across levels of pre-pregnancy weight. ^
Resumo:
Objective. To assess differences in body weight, body composition, total cholesterol, blood pressure, and blood glucose between OC users and non-users age 18-30 y before and after a 15-week cardiovascular exercise program in Houston, TX from 2003 to 2007.^ Study Design. Secondary analysis of prospective data. ^ Study Subjects. 453 Non-Hispanic white (NHW), Hispanic, and African American (AA) women age 18-30 y with no previous live birth, a history of menstruating, no use of other hormonal contraceptives or medications, no menopause or hysterectomy, and no current pregnancies.^ Measurements. Demographic data, medication use, and menstrual history were assessed via self-administered questionnaires at baseline. Anthropometric and laboratory measures were taken at baseline and 15-weeks. ^ Data Analysis. Linear regression assessed the association between OC use and study variables at baseline, and the change in study variables from baseline to 15-weeks. Logistic regression assessed the association between OC use and CVD risk. Each analysis was also stratified by race/ethnicity. ^ Results. At baseline, OC users had higher total cholesterol (p<.0005) and were above cholesterol risk cut points for CVD (OR=4.3, 95% CI=2.4-7.7) compared to non-users. At baseline, OC use was also associated with higher diastolic blood pressure (p=.018) compared to non-users, primarily in non-Hispanic whites (p=.007). OC use was associated with lower blood glucose compared to non-users in Hispanics only (p=.008). OC use was associated with absolute change in diastolic blood pressure (p=.044) and total cholesterol (p=.003). There was evidence that OC use may affect individuals differently based on race/ethnicity for certain obesity and CVD risk factors.^ Conclusions. OC users and non-users responded similarly to a 15-week cardiovascular exercise program. Exceptions included a greater change in diastolic blood pressure and total cholesterol among NHW and Hispanic OC users compared to non-users after exercise intervention. At baseline, OC use was associated with diastolic blood pressure and was most strongly associated with increased levels of total cholesterol. OC users were at greater risk of having total cholesterol above CVD risk cut points than non-users.^
Resumo:
Background. Excess weight and obesity are at epidemic proportions in the United States and place individuals at increased risk for a variety of chronic conditions. Rates of diabetes, high blood pressure, coronary artery disease, stroke, cancer, and arthritis are all influenced by the presence of obesity. Small reductions in excess weight can produce significant positive clinical outcomes. Healthcare organizations have a vital role to play in the identification and management of obesity. Currently, healthcare providers do not adequately diagnose and manage excess weight in patients. Lack of skill, time, and knowledge are commonly cited as reasons for non-adherence to recommended standards of care. The Chronic Care Model offers an approach to healthcare organizations for chronic disease management. The model consists of six elements that work together to empower both providers and patients to have more productive interactions: the community, the health system itself, self-management support, delivery system design, decision support, and clinical information systems. The model and its elements may offer a framework through which healthcare organizations can adapt to support, educate, and empower providers and patients in the management of excess weight and obesity. Successful management of excess weight will reduce morbidity and mortality of many chronic conditions. Purpose. The purpose of this review is to synthesize existing research on the effectiveness of the Chronic Care Model and its elements as they relate to weight management and behaviors associated with maintaining a healthy weight. Methods: A narrative review of the literature between November 1998 and November 2008 was conducted. The review focused on clinical trials, systematic reviews, and reports related to the chronic care model or its elements and weight management, physical activity, nutrition, or diabetes. Fifty-nine articles are included in the review. Results. This review highlights the use of the Chronic Care Model and its elements that can result in improved quality of care and clinical outcomes related to weight management, physical activity, nutrition, and diabetes. Conclusions. Healthcare organizations can use the Chronic Care Model framework to implement changes within their systems to successfully address overweight and obesity in their patient populations. Specific recommendations for operationalizing the Chronic Care Model elements for weight management are presented.^