956 resultados para Scanline sampling technique
Resumo:
A scheme for built-in self-test of analog signals with minimal area overhead for measuring on-chip voltages in an all-digital manner is presented. The method is well suited for a distributed architecture, where the routing of analog signals over long paths is minimized. A clock is routed serially to the sampling heads placed at the nodes of analog test voltages. This sampling head present at each test node, which consists of a pair of delay cells and a pair of flip-flops, locally converts the test voltage to a skew between a pair of subsampled signals, thus giving rise to as many subsampled signal pairs as the number of nodes. To measure a certain analog voltage, the corresponding subsampled signal pair is fed to a delay measurement unit to measure the skew between this pair. The concept is validated by designing a test chip in a UMC 130-nm CMOS process. Sub-millivolt accuracy for static signals is demonstrated for a measurement time of a few seconds, and an effective number of bits of 5.29 is demonstrated for low-bandwidth signals in the absence of sample-and-hold circuitry.
Resumo:
Remote sensing of physiological parameters could be a cost effective approach to improving health care, and low-power sensors are essential for remote sensing because these sensors are often energy constrained. This paper presents a power optimized photoplethysmographic sensor interface to sense arterial oxygen saturation, a technique to dynamically trade off SNR for power during sensor operation, and a simple algorithm to choose when to acquire samples in photoplethysmography. A prototype of the proposed pulse oximeter built using commercial-off-the-shelf (COTS) components is tested on 10 adults. The dynamic adaptation techniques described reduce power consumption considerably compared to our reference implementation, and our approach is competitive to state-of-the-art implementations. The techniques presented in this paper may be applied to low-power sensor interface designs where acquiring samples is expensive in terms of power as epitomized by pulse oximetry.
Resumo:
The paper proposes Latin hypercube sampling combined with the stratified sampling of variance reduction technique to calculate accurate fracture probability. In the compound sampling, the number of simulations is relatively small and the calculation error is satisfactory.
Resumo:
A new method is described and evaluated for visually sampling reef fish community structure in environments with highly diverse and abundant reef fish populations. The method is based on censuses of reef fishes taken within a cylinder of 7.5 m radius by a diver at randomly selected, stationary points. The method provides quantitative data on frequency of occnrrence, fish length, abundance, and community composition, and is simple, fast, objective, and repeatable. Species are accumulated rapidly for listing purposes, and large numbers of samples are easily obtained for statistical treatment. The method provides an alternative to traditional visual sampling methods. Observations showed that there were no significant differences in total numbers of species or individuals censused when visibility ranged between 8 and 30 m. The reefs and habitats sampled were significant sources of variation in number of species and individuals censused, but the diver was not a significant influence. Community similarity indices were influenced significantly by the specific sampling site and the reef sampled, but were not significantly affected by the habitat or diver (PDF file contains 21 pages.)
Resumo:
The direct simulation Monte Carlo (DSMC) method is a widely used approach for flow simulations having rarefied or nonequilibrium effects. It involves heavily to sample instantaneous values from prescribed distributions using random numbers. In this note, we briefly review the sampling techniques typically employed in the DSMC method and present two techniques to speedup related sampling processes. One technique is very efficient for sampling geometric locations of new particles and the other is useful for the Larsen-Borgnakke energy distribution.
Resumo:
A new approach based on the gated integration technique is proposed for the accurate measurement of the autocorrelation function of speckle intensities scattered from a random phase screen. The Boxcar used for this technique in the acquisition of the speckle intensity data integrates the photoelectric signal during its sampling gate open, and it repeats the sampling by a preset number, in. The average analog of the in samplings output by the Boxcar enhances the signal-to-noise ratio by root m, because the repeated sampling and the average make the useful speckle signals stable, while the randomly varied photoelectric noise is suppressed by 1/ root m. In the experiment, we use an analog-to-digital converter module to synchronize all the actions such as the stepped movement of the phase screen, the repeated sampling, the readout of the averaged output of the Boxcar, etc. The experimental results show that speckle signals are better recovered from contaminated signals, and the autocorrelation function with the secondary maximum is obtained, indicating that the accuracy of the measurement of the autocorrelation function is greatly improved by the gated integration technique. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
The potential for changes to onboard handling practices in order to improve the fate of juvenile school prawns (Metapenaeus macleayi) discarded during trawling were investigated in two Australian rivers (Clarence and Hunter) by comparing a purpose-built, water-filled sorting tray against a conventional dry tray across various conditions, including the range of typical delays before the start of sorting the catch (2 min vs. 15 min). Juvenile school prawns (n= 5760), caught during 32 and 16 deployments in each river, were caged and sacrificed at four times: immediately (T0), and at 24 (T24), 72 (T72), and 120 (T12 0) hours after having been discarded. In both rivers, most mortalities occurred between T0 and T24 and, after adjusting for control deaths (<12%), were greatest for the 15-min conventional treatment (up to 41% at T120). Mixed-effects logistic models revealed that in addition to the sampling time, method of sorting, and delay in sorting, the weight of the catch, salinity, and percentage cloud cover were significant predictors of mortality. Although trawling caused some mortalities and comparable stress (measured as L -lactate) in all school prawns, use of the water tray lessened the negative impacts of some of the above factors across both the 2-min and 15-min delays in sorting so that the overall discard mortality was reduced by more than a third. When used in conjunction with selective trawls, widespread application of the water tray should help to improve the sustainability of trawling for school prawns.
Resumo:
For bacterial sampling of raw unprocessed fish and frozen fishery products, spread plate method is preferable to pour plate method; incubation of plates at 30°C gives a higher count than incubation at 37°C. Analysis of variance of the data shows that sample variation between different types of fishes is highly significant whereas the variations between triplicate plates are not significant at 5 % level.
Resumo:
In order to carry out Biometric studies, 75 samples were caught from 3 locations ( Tajan river, Sefidrud and Shirud) using Salic and the length (±1 mm) and weights (± 5 gr) of samples were determined. Using One-way ANOVA by SPPSS software, there wasn’t significant difference between locations in length and fecondity (P ≥0.01(, but there was significant difference between Shirud and tajan samples with sefidrud in weight ) P≤0.01(. In order to carry out genetic variation studies, 210 fish were caught from 3 different regions of the Iranian coastline (Khoshkrud, Tonekabon, Gorganrud) and 1 region in Azerbaijan (Waters of the Caspian Sea close to Kura River mouth) during 2008-2009 . Genomic DNA was extracted of fin using the phenol-chloroform. The quantity and quality of DNA from samples were assessed by spectrophptometer and 1% agarose gel electro-phoresis. PCR was carried out using 15 paired microsatellite primers. PCR products were separated on 8% polyacrylamide gels that were stained using silver nitrate. Molecular weight calculate using UVTech software. The recorded microsatellite genotypes were used as input data for the GENALEX software version 6 package in order to calculate allele and genotype frequencies, observed (Ho) and (He) expected heterozygosities and to test for deviations from Hardy-Weinberg equilibrium. Genetic distance between two populations was estimated from Nei standard genetic distance and genetic similarity index (Nei, 1972). Genetic differentiation between populations was also evaluated by the calculation of pairwise estimates of Fst and Rst values. From 15 SSR markers were used in this investigation, 9 of them were polymorph. Average of expected and observed heterozygosity was 0.54 and 0.49 respectively. Significant deviations from Hardy-Weinberg expectations were observed in all of location except Anzali lagoon- autumn in AF277576 and EF144125, Khoshkrud in EF144125 and Gorganrud and Kura in AF277576. Using Fst and Rst there was significant difference between locations ) P≤0.01(. According to Fst , the highest population differentiation (Fst= 0.217) was between Gorganrud and Khoshkrud that have the lowest Nm and the lowest (Fst= 0.086) was between Gorganrud and Tonekabon that have the highest Nm. Using Rst the highest population differentiation (Rst= 0.271) was between Tonekabon and spring Anzali lagoon and the lowest (Rst= 0.026) was between Tonekabon and Autumn Anzali 159 lagoon. Also the difference between Spring Anzali lagoon and Autumn Anzali lagoon was noticeable (Fst=0.15). AMOVA analysis with consideration of 2 sampling regions (Iran and Azerbaijan) and 7 sampling locations (Iran: Khoshkrud, Tonekabon, Gorganrud, Spring Anzali lagoon and Autumn Anzali lagoon ; Azerbaijan: the Kura mouth) revealed that almost all of the variance in data namely 83% )P≤0.01( was within locations, Genetic variances among locations was 14% )P≤0.01( and among regions was 3% )P≤0.01(. The genetic distance was the highest (0.646) between Gorganrud and Autumn Anzali lagoon populations, whereas the lowest distance (0.237) was between Gorganrud and Tonekabon River. Result obtained from the present study show that at least 2 different population of Rutilus frissi kutum are found in the Caspian sea,which are including the kura river population and the southern Caspian sea samples and it appears that there is more than one population in southern Caspian sea that should be attantioned in artifical reproduction Center and stoke rebilding.
Resumo:
In this paper, we propose a low complexity and reliable wideband spectrum sensing technique that operates at sub-Nyquist sampling rates. Unlike the majority of other sub-Nyquist spectrum sensing algorithms that rely on the Compressive Sensing (CS) methodology, the introduced method does not entail solving an optimisation problem. It is characterised by simplicity and low computational complexity without compromising the system performance and yet delivers substantial reductions on the operational sampling rates. The reliability guidelines of the devised non-compressive sensing approach are provided and simulations are presented to illustrate its superior performance. © 2013 IEEE.
Resumo:
Wind erosion is one of the major environmental problems in semi-arid and arid regions. Here we established the Tariat-Xilin Gol transect from northwest to southeast across the Mongolian Plateau, and selected seven sampling sites along the transect. We then estimated the soil wind erosion rates by using the Cs-137 tracing technique and examined their spatial dynamics. Our results showed that the Cs-137 inventories of sampling sites ranged from 265.63 +/- 44.91 to 1279.54 +/- 166.53 Bq.m(-2), and the wind erosion rates varied from 64.58 to 419.63 t.km(-2).a(-1) accordingly. In the Mongolia section of the transect (from Tariat to Sainshand), the wind erosion rate increased gradually with vegetation type and climatic regimes; the wind erosion process was controlled by physical factors such as annual precipitation and vegetation coverage, etc., and the impact of human activities was negligible. While in the China section of the transect (Inner Mongolia), the wind erosion rates of Xilin Hot and Zhengxiangbai Banner were thrice as much as those of Bayannur of Mongolia, although these three sites were all dominated by typical steppe. Besides the physical factors, higher population density and livestock carrying level should be responsible for the higher wind erosion rates in these two regions of Inner Mongolia.
Resumo:
A novel technique to detect and localize periodic movements in video is presented. The distinctive feature of the technique is that it requires neither feature tracking nor object segmentation. Intensity patterns along linear sample paths in space-time are used in estimation of period of object motion in a given sequence of frames. Sample paths are obtained by connecting (in space-time) sample points from regions of high motion magnitude in the first and last frames. Oscillations in intensity values are induced at time instants when an object intersects the sample path. The locations of peaks in intensity are determined by parameters of both cyclic object motion and orientation of the sample path with respect to object motion. The information about peaks is used in a least squares framework to obtain an initial estimate of these parameters. The estimate is further refined using the full intensity profile. The best estimate for the period of cyclic object motion is obtained by looking for consensus among estimates from many sample paths. The proposed technique is evaluated with synthetic videos where ground-truth is known, and with American Sign Language videos where the goal is to detect periodic hand motions.
Resumo:
The comet assay is a technique used to quantify DNA damage and repair at a cellular level. In the assay, cells are embedded in agarose and the cellular content is stripped away leaving only the DNA trapped in an agarose cavity which can then be electrophoresed. The damaged DNA can enter the agarose and migrate while the undamaged DNA cannot and is retained. DNA damage is measured as the proportion of the migratory ‘tail’ DNA compared to the total DNA in the cell. The fundamental basis of these arbitrary values is obtained in the comet acquisition phase using fluorescence microscopy with a stoichiometric stain in tandem with image analysis software. Current methods deployed in such an acquisition are expected to be both objectively and randomly obtained. In this paper we examine the ‘randomness’ of the acquisition phase and suggest an alternative method that offers both objective and unbiased comet selection. In order to achieve this, we have adopted a survey sampling approach widely used in stereology, which offers a method of systematic random sampling (SRS). This is desirable as it offers an impartial and reproducible method of comet analysis that can be used both manually or automated. By making use of an unbiased sampling frame and using microscope verniers, we are able to increase the precision of estimates of DNA damage. Results obtained from a multiple-user pooled variation experiment showed that the SRS technique attained a lower variability than that of the traditional approach. The analysis of a single user with repetition experiment showed greater individual variances while not being detrimental to overall averages. This would suggest that the SRS method offers a better reflection of DNA damage for a given slide and also offers better user reproducibility.
Resumo:
This paper reports the detailed description and validation of a fully automated, computer controlled analytical method to spatially probe the gas composition and thermal characteristics in packed bed systems. As an exemplar, we have examined a heterogeneously catalysed gas phase reaction within the bed of a powdered oxide supported metal catalyst. The design of the gas sampling and the temperature recording systems are disclosed. A stationary capillary with holes drilled in its wall and a moveable reactor coupled with a mass spectrometer are used to enable sampling and analysis. This method has been designed to limit the invasiveness of the probe on the reactor by using the smallest combination of thermocouple and capillary which can be employed practically. An 80 mu m (O.D.) thermocouple has been inserted in a 250 mu m (O.D.) capillary. The thermocouple is aligned with the sampling holes to enable both the gas composition and temperature profiles to be simultaneously measured at equivalent spatially resolved positions. This analysis technique has been validated by studying CO oxidation over a 1% Pt/Al2O3 catalyst and the spatial resolution profiles of chemical species concentrations and temperature as a function of the axial position within the catalyst bed are reported.
Resumo:
Objectives: To explore children's views on microneedle use for this population, particularly as an alternative approach to blood sampling, in monitoring applications, and so, examine the acceptability of this approach to children.
Methods: Focus groups were conducted with children (aged 10-14 years) in a range of schools across Northern Ireland. Convenience sampling was employed, i.e. children involved in a university-directed community-outreach project (Pharmacists in Schools) were recruited.
Key findings: A total of 86 children participated in 13 focus groups across seven schools in Northern Ireland. A widespread disapproval for blood sampling was evident, with pain, blood and traditional needle visualisation particularly unpopular aspects. In general, microneedles had greater visual acceptability and caused less fear. A patch-based design enabled minimal patient awareness of the monitoring procedure, with personalised designs, e.g. cartoon themes, favoured. Children's concerns included possible allergy and potential inaccuracies with this novel approach; however, many had confidence in the judgement of healthcare professionals if deeming this technique appropriate. They considered paediatric patient education critical for acceptance of this new approach and called for an alternative name, without any reference to 'needles'.
Conclusions: The findings presented here support the development of blood-free, minimally invasive techniques and provide an initial indication of microneedle acceptability in children, particularly for monitoring purposes. A proactive response to these unique insights should enable microneedle array design to better meet the needs of this end-user group. Further work in this area is recommended to ascertain the perspectives of a purposive sample of children with chronic conditions who require regular monitoring. © 2013 Royal Pharmaceutical Society.