981 resultados para STRUCTURAL TESTING CRITERIA
Resumo:
Ideally projected to be applied on soft tissues, infrared lasers were improved by restorative dentistry to be used in hard dental tissues cavity preparations-namely enamel and dentin. This paper evidentiates the relevant aspects of infrared Erbium laser's action mechanism and its effects, and characterizes the different effects deriving from the laser's beams emission. The criteria for use and selection of optimal parameters for the correct application of laser systems and infuence of supporting factors on the process, such as water amount and its presence in the ablation process, protection exerted by the plasma shielding and structural factors, which are indispensable in dental tissues cavity preparation related to restorative technique, are subordinated to optical modifcations caused by the interaction of the energy dissipated by these laser light emission systems in the targeted tissue substrate. Clinical relevance: Differences in the action of infrared Erbium laser system in regard to the nature of the ablation process and variations on the morphological aspects observed in the super-fcial structure of the target tissue irradiated, may be correlated to the structural optical modifcations of the substrate produced by an interaction of the energy propagated by laser systems.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background: The main manifestation of hyperglycaemia during pregnancy is gestational diabetes mellitus. It can herald diabetes mellitus type 2 and its deleterious long-term effects, such as hypertension and cardiovascular disease. The aim of this study was to assess diastolic function in women with gestational diabetes mellitus, one of the first signs of future cardiovascular disease.Methods: A total of 21 women with gestational diabetes mellitus and 23 healthy pregnant women (control group) between 34 and 37weeks of gestation underwent echocardiographic assessment. The diagnosis of gestational diabetes mellitus was made in agreement with the American Diabetes Association criteria. Echocardiographic images obtained were analysed according to the criteria of the American Society of Echocardiography. Data were analysed using Pearson correlation coefficient, analysis of variance and Student's t-test.Results: Women with gestational diabetes mellitus had higher posterior wall and interventricular septum thickness, increased left ventricular mass and left ventricular mass index, lower early diastolic annular velocity and early diastolic annular velocity/late diastolic annular velocity ratio. There was a positive correlation between left ventricular mass index and fasting glucose and pregnancy body mass index.Conclusion: Patients with gestational diabetes mellitus seem to have a different diastolic profile as well as a mildly dysfunctional pattern on echocardiogram, which may show a need for greater glycaemic control.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The broader knowledge about physical and mechanical properties of wood allows reliable timber structures design. Even little addressed in the literature, in several situations Poisson's ratios are required for the evaluation of stresses acting on structural elements. This study aimed to obtain values of Poisson's ratios (ν), plans Longitudinal-Radial (νLR) and Longitudinal-Tangential (νLT), for species Peroba Rosa (Aspidosperma polyneuron) and Jatobá (Hymenaea courbaril L.). For this purpose, forty samples Peroba Rosa and eight samples of Jatobá were prepared for testing in compression parallel to the grain, following the recommendations of ABNT NBR 7190 standard. The results of means confidence intervals, considered at the level of 5% significance, revealed that the Poisson's ratios νLR e νLT to Peroba Rosa are 0.27 and 0.42, respectively, and 0.25 and 0.43 to Jatobá.
Resumo:
A new steel girder bridge system was developed at the University of Nebraska. The innovative girder design is a box girder folded from a single steel plate that has a trapezoid shape with an opening on the bottom. The girder has application in short span bridges and accelerated construction situations. The structural performance of the girder requires investigation in all stages of a bridge’s lifecycle. This thesis contains descriptions and results from the first two tests from a series of tests developed to evaluate this new girder shape. The objective of these two tests was to investigate the constructability of the girders. During construction a bridge is in its least stable condition and it is important that the bridge components exhibit both adequate strength and stability during this critical stage. To this end, two girders were tested in flexure over a simple span as a non-composite beam simulating the loading the girders would be subjected to during construction. The results of the two tests indicate that the folded girder as a whole, and its components, provide adequate strength and stability at construction load levels. Failure occurred at loads that were above normal construction load levels and resulted in a ductile failure mode, which is a well documented benefit of steel components. The girders remained stable through all phases of loading including failure. The top flange was the weakest component of the beam during construction due to its role as a compression element that has a slender and un-braced form. The compression in the top flange caused local buckling in the top flange even at elastic load levels. This was the cause for loss of stiffness and failure in both specimens. Incorporation of a ridge at the center of the top flange of specimens, results of which are not reported in this thesis, proved to resolve this very early buckling issue.
Resumo:
There are several techniques to characterize the elastic modulus of wood and those currently using the natural frequencies of vibration stand out as they are non-destructive techniques, producing results that can be repeated and compared over time. This study reports on the effectiveness of the testing methods based on the natural frequencies of vibration versus static bending to obtain the elastic properties of reforested structural wood components usually employed in civil construction. The following components were evaluated: 24 beams of Eucalyptus sp. with nominal dimensions (40 x 60 x 2.000 mm) and 14 beams of Pinus oocarpa with nominal dimensions (45 x 90 x 2.300 mm) both without treatment; 30 boards with nominal dimensions (40 x 240 x 2.010 mm) and 30 boards with nominal dimensions (40 x 240 x 3.050 mm), both of Pinus oocarpa and with chromate copper arsenate (CCA) preservative treatment. The results obtained in thiswork show good correlation when compared to the results obtained by the static bending mechanical method, especially when applying the natural frequency of longitudinal vibration. The use of longitudinal frequency was reliable and practical, therefore recommended for determining the modulus of elasticity of wood structural elements. It was also found that no specific support is needed for the specimens using the longitudinal frequency, as well as no previous calibrations, reducing the execution time and enabling to test many samples.
Resumo:
Aims: This report discusses the use of antinuclear antibody (ANA) detection as a screening test for neuropsychiatry systemic lupus erythematosus (NPSLE) in patients presenting a first-episode psychosis. Methods: We reviewed the medical records of 85 patients admitted to an emergency service due to first-episode psychosis, during a 1-year period, for whom ANA detection was performed through an IFI HEp2 cell assay. ANA-positive patients were subsequently evaluated for autoantibodies and neuroimaging exams. Results: Three patients presented as ANA positive in the initial screening and further investigation confirmed NPSLE in two patients. The patients were treated with antipsychotics and cyclophosphamide pulses with satisfactory outcomes. Conclusion: Even though ANA detection is not specific, it is a low-cost procedure and could be an important screening test for NPSLE in the early-onset psychosis.
Resumo:
Background: Clinical multistage risk assessment associated with electrocardiogram (ECG) and NT-proBNP may be a feasible strategy to screen hypertrophic cardiomyopathy (HCM). We investigated the effectiveness of a screening based on ECG and NT-proBNP in first-degree relatives of patients with HCM. Methods and Results: A total of 106 first-degree relatives were included. All individuals were evaluated by echocardiography, ECG, NT-proBNP, and molecular screening (available for 65 individuals). From the 106 individuals, 36 (34%) had diagnosis confirmed by echocardiography. Using echocardiography as the gold standard, ECG criteria had a sensitivity of 0.71, 0.42, and 0.52 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Mean values of NT-ProBNP were higher in affected as compared with nonaffected relatives (26.1 vs. 1290.5, P < .001). The AUC of NT-proBNP was 0.98. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.92 and specificity of 0.96. Using molecular genetics as the gold standard, ECG criteria had a sensitivity of 0.67, 0.37, and 0.42 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.83 and specificity of 0.98. Conclusion: Values of NT-proBNP above 70 pg/mL can be used to effectively select high-risk first-degree relatives for HCM screening. (J Cardiac Fail 2012;18:564-568)
Resumo:
Abstract Background Considering the increasing use of polymyxins to treat infections due to multidrug resistant Gram-negative in many countries, it is important to evaluate different susceptibility testing methods to this class of antibiotic. Methods Susceptibility of 109 carbapenem-resistant P. aeruginosa to polymyxins was tested comparing broth microdilution (reference method), disc diffusion, and Etest using the new interpretative breakpoints of Clinical and Laboratory Standards Institute. Results Twenty-nine percent of isolates belonged to endemic clone and thus, these strains were excluded of analysis. Among 78 strains evaluated, only one isolate was resistant to polymyxin B by the reference method (MIC: 8.0 μg/mL). Very major and major error rates of 1.2% and 11.5% were detected comparing polymyxin B disc diffusion with the broth microdilution (reference method). Agreement within 1 twofold dilution between Etest and the broth microdilution were 33% for polymyxin B and 79.5% for colistin. One major error and 48.7% minor errors were found comparing polymyxin B Etest with broth microdilution and only 6.4% minor errors with colistin. The concordance between Etest and the broth microdilution (reference method) was respectively 100% for colistin and 90% for polymyxin B. Conclusion Resistance to polymyxins seems to be rare among hospital carbapenem-resistant P. aeruginosa isolates over a six-year period. Our results showed, using the new CLSI criteria, that the disc diffusion susceptibility does not report major errors (false-resistant results) for colistin. On the other hand, showed a high frequency of minor errors and 1 very major error for polymyxin B. Etest presented better results for colistin than polymyxin B. Until these results are reproduced with a large number of polymyxins-resistant P. aeruginosa isolates, susceptibility to polymyxins should be confirmed by a reference method.
Resumo:
This work provides a numerical and experimental investigation of fatigue crack growth behavior in steel weldments including crack closure effects and their coupled interaction with weld strength mismatch. A central objective of this study is to extend previously developed frameworks for evaluation of crack clo- sure effects on FCGR to steel weldments while, at the same time, gaining additional understanding of commonly adopted criteria for crack closure loads and their influence on fatigue life of structural welds. Very detailed non-linear finite element analyses using 3-D models of compact tension C ( T ) fracture spec- imens with center cracked, square groove welds provide the evolution of crack growth with cyclic stress intensity factor which is required for the estimation of the closure loads. Fatigue crack growth tests con- ducted on plane-sided, shallow-cracked C ( T ) specimens provide the necessary data against which crack closure effects on fatigue crack growth behavior can be assessed. Overall, the present investigation pro- vides additional support for estimation procedures of plasticity-induced crack closure loads in fatigue analyses of structural steels and their weldments
Resumo:
Catenary risers can present during installation a very low tension close to seabed, which combined with torsion moment can lead to a structural instability, resulting in a loop. This is undesirable once it is possible that the loop turns into a kink, creating damage. This work presents a numerical methodology to analyze the conditions of loop formation in catenary risers. Stability criteria were applied to finite element models, including geometric nonlinearities and contact constraint due to riser-seabed interaction. The classical Greenhill's formula was used to predict the phenomenon and parametric analysis shows a “universal plot” able to predict instability in catenaries using a simple equation that can be applied for typical risers installation conditions and, generically, for catenary lines under torsion.
Resumo:
Assessment of the integrity of structural components is of great importance for aerospace systems, land and marine transportation, civil infrastructures and other biological and mechanical applications. Guided waves (GWs) based inspections are an attractive mean for structural health monitoring. In this thesis, the study and development of techniques for GW ultrasound signal analysis and compression in the context of non-destructive testing of structures will be presented. In guided wave inspections, it is necessary to address the problem of the dispersion compensation. A signal processing approach based on frequency warping was adopted. Such operator maps the frequencies axis through a function derived by the group velocity of the test material and it is used to remove the dependence on the travelled distance from the acquired signals. Such processing strategy was fruitfully applied for impact location and damage localization tasks in composite and aluminum panels. It has been shown that, basing on this processing tool, low power embedded system for GW structural monitoring can be implemented. Finally, a new procedure based on Compressive Sensing has been developed and applied for data reduction. Such procedure has also a beneficial effect in enhancing the accuracy of structural defects localization. This algorithm uses the convolutive model of the propagation of ultrasonic guided waves which takes advantage of a sparse signal representation in the warped frequency domain. The recovery from the compressed samples is based on an alternating minimization procedure which achieves both an accurate reconstruction of the ultrasonic signal and a precise estimation of waves time of flight. Such information is used to feed hyperbolic or elliptic localization procedures, for accurate impact or damage localization.
Resumo:
Multifunctional Structures (MFS) represent one of the most promising disruptive technologies in the space industry. The possibility to merge spacecraft primary and secondary structures as well as attitude control, power management and onboard computing functions is expected to allow for mass, volume and integration effort savings. Additionally, this will bring the modular construction of spacecraft to a whole new level, by making the development and integration of spacecraft modules, or building blocks, leaner, reducing lead times from commissioning to launch from the current 3-6 years down to the order of 10 months, as foreseen by the latest Operationally Responsive Space (ORS) initiatives. Several basic functionalities have been integrated and tested in specimens of various natures over the last two decades. However, a more integrated, system-level approach was yet to be developed. The activity reported in this thesis was focused on the system-level approach to multifunctional structures for spacecraft, namely in the context of nano- and micro-satellites. This thesis documents the work undertaken in the context of the MFS program promoted by the European Space Agency under the Technology Readiness Program (TRP): a feasibility study, including specimens manufacturing and testing. The work sequence covered a state of the art review, with particular attention to traditional modular architectures implemented in ALMASat-1 and ALMASat-EO satellites, and requirements definition, followed by the development of a modular multi-purpose nano-spacecraft concept, and finally by the design, integration and testing of integrated MFS specimens. The approach for the integration of several critical functionalities into nano-spacecraft modules was validated and the overall performance of the system was verified through relevant functional and environmental testing at University of Bologna and University of Southampton laboratories.
Resumo:
The Pulmonary Embolism Rule-out Criteria (PERC) rule is a clinical diagnostic rule designed to exclude pulmonary embolism (PE) without further testing. We sought to externally validate the diagnostic performance of the PERC rule alone and combined with clinical probability assessment based on the revised Geneva score.