569 resultados para SILICONE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

After massive weight loss, one of the stigmas that afflict women is the remaining deformity of the breasts which become flaccid and ptotic, with an absent or flat upper pole. The authors propose the use of a well-established mammaplasty technique to fill the upper pole, reshape the breast cone, and correct ptosis with nipple-areola complex (NAC) repositioning. A total of 16 patients were analyzed; all underwent gastroplasty between 18 and 24 months prior to mammaplasty. The mean age was 41.6 years (range = 26-62) and the mean BMI previous to the mammaplasty was 29.2 kg/m(2) (range = 24.9-38.9). The technique included a dermo-lipo glandular flap pedicled on the inframammary fold (IMF) together with a superior flap containing the NAC. All patients who underwent surgery were satisfied with the outcomes since a more aesthetic breast shape was achieved, with projection of the upper pole and correction of ptosis. Adverse events included dehiscence at the junction point of the flaps in the inframammary fold, which resolved with secondary-intention wound healing in three patients; partial necrosis of the areola in one patient; epidermolysis in one of the NACs in one patient; and infection in one of the breasts in one patient, which resolved with proper antibiotic therapy. When compared to the current mammaplasty techniques performed in formerly obese patients, this is a good surgical option because it uses tissues adjacent to the breast itself and does not require silicone prosthesis for breast augmentation. The patients reported increased self-esteem and improvement in their quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study provides an investigation of the availability of octyl salicylate (OS), a common sunscreen agent, from liquid paraffin and the effect of OS on skin permeability. A model membrane system to isolate the vehicle effect from membrane permeability has been developed. Partitioning of OS between liquid paraffin and aqueous receptor phases was conducted. Partition coefficients increased with increase in OS concentration. A range of OS concentrations in liquid paraffin was diffused across human epidermis and synthetic membranes into 4% bovine serum albumin in phosphate-buffered saline and 50% ethanol. Absorption profiles of OS obtained from silicone and low-density polyethylene (LDPE) membranes were similar to each other but higher than for the high-density polyethylene [HDPE (3 times)] membrane and human epidermis (15 times). The steady state fluxes and apparent permeability coefficients (K-p') obtained from the diffusion studies showed the same trends with all membranes, except for the HDPE membrane which showed greater increase in flux and K-p' at concentrations above 30%. IR spectra showed that several bands of OS were shifted with concentrations, and the molecular models further suggested that the main contribution to the self-association is from non-1,4 van der Waals interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyze the influence of thermal partial punctal occlusion on the ocular surface of dry eye related to Sjogren syndrome. Material and Methods: Thirty-seven eyes of 19 patients (3 male and 16 female; 49.11 +/- 14.33 years old) with keratoconjunctivitis sicca were enrolled in this study. Superior and inferior partial occlusion were performed in both eyes under topical anesthesia using thermal cautery with a sterile tip to obtain lacrimal punctum smaller than 0.5 mm. Schirmer I, break-up-time, diameter of lacrimal puncta, corneal fluorescein, and rose Bengal staining scores were analyzed before and after 24 weeks and after 24 months of the procedure. All measurements were performed under controlled climate. Results: The average lacrimal punctum diameter before the procedure was 0.65 +/- 0.134 mm. All lacrimal puncta were successfully reduced to less than 0.5 mm after 4 weeks of the procedure. The average Schirmer I test values improved statistically after 24 weeks and maintained stable after 24 months. Average break-up-time, rose Bengal, and fluorescein staining score values improved statistically after 24 weeks and improved even more after 24 months. Average Schirmer I test, break-up-time, rose Bengal, and fluorescein staining scores showed significant improvement (p < 0.0001) after 24 months of partial thermal punctal occlusion. Conclusion: Our study showed that reducing the punctum diameter to 0.5 mm can improve vital staining scores, break-up-time, and Schirmer I test in dry eye related to Sjogren syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the use of orbital polyacrylamide gel injection for the correction of anophthalmic enophthalmos. Methods: Noncontrolled clinical trial of 21 patients (14 with ocular implants, 5 with phthisis bulbi, and 2 with dermis-fat graft). Orbital CT was performed to estimate the volume of polyacrylamide gel needed to restore orbital volume. Polyacrylamide gel was injected using a 22-gauge (30 x 0.7 min) needle transcutaneously inserted in the lateral third of the lower eyelid, directed to the orbital muscle cone. A second injection was administered 15 days later. if necessary. CT was repeated 30 days after the last procedure. Exophthalmometry was performed before Bind 90 days after file procedure. Results: The mean total volume injected per orbit was 2.4 +/- 0.7 ml (range 1-3.5 ml). The volume of the enophthalmic orbit increased front 26.9 +/- 5.0 ml to 29.3 +/- 4.9 ml (p < 0.001). The mean difference in exophthalmometry readings was 3.3 +/- 1.6 mm (range, 1.5-8.0 mm) before the procedure and 1.0 +/- 0.9 mm (range, 0.0-3.0 mm) after 3 months (p < 0.001). Adjustment of the ocular prosthesis or fabrication of a new one was necessary in 11 patients (52.4%), and the mean volume of the ocular prosthesis was reduced front 2.0 +/- 0.6 ml to 1.6 +/- 0.6 ml (p = 0.003). All patients were satisfied with the aesthetic results. No serious adverse events were observed. The initial results were maintained 1 year after the procedure. Conclusions: Polyacrylamide gel injection in the orbital space effectively reduces enophthalmos in ocular prosthesis wearers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The pterygopalatine fossa (PPF) is a narrow space located between the posterior wall of the antrum and the pterygoid plates. Surgical access to the PPF is difficult because of its protected position and its complex neurovascular anatomy. Endonasal approaches using rod lens endoscopes, however, provide better visualization of this area and are associated with less morbidity than external approaches. Our aim was to develop a simple anatomical model using cadaveric specimens injected with intravascular colored silicone to demonstrate the endoscopic anatomy of the PPF. This model could be used for surgical instruction of the transpterygoid approach. Methods: We dissected six PPF in three cadaveric specimens prepared with intravascular injection of colored material using two different injection techniques. An endoscopic endonasal approach, including a wide nasoantral window and removal of the posterior antrum wall, provided access to the PPF. Results: We produced our best anatomical model injecting colored silicone via the common carotid artery. We found that, using an endoscopic approach, a retrograde dissection of the sphenopalatine artery helped to identify the internal maxillary artery (IMA) and its branches. Neural structures were identified deeper to the vascular elements. Notable anatomical landmarks for the endoscopic surgeon are the vidian nerve and its canal that leads to the petrous portion of the internal carotid artery (ICA), and the foramen rotundum, and V2 that leads to Meckel`s cave in the middle cranial fossa. These two nerves, vidian and V2, are separated by a pyramidal shaped bone and its apex marks the ICA. Conclusion: Our anatomical model provides the means to learn the endoscopic anatomy of the PPF and may be used for the simulation of surgical techniques. An endoscopic endonasal approach provides adequate exposure to all anatomical structures within the PPF. These structures may be used as landmarks to identify and control deeper neurovascular structures. The significance is that an anatomical model facilitates learning the surgical anatomy and the acquisition of surgical skills. A dissection superficial to the vascular structures preserves the neural elements. These nerves and their bony foramina, such as the vidian nerve and V2, are critical anatomical landmarks to identify and control the ICA at the skull base.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Bronchial complications owing to the airway anastomosis in lung transplantation are important causes of morbidity and mortality. They occur in up to 27% of cases as defined by stenosis, necrosis, and dehiscence. Treatment depends on the type of complication. Objective. To report our experience to treat this complication. Methods. Between 2000 and 2007, we performed 71 lung transplants of which 36 were bilateral. The total number of anastomoses was 107:52 to the right and 55 to the left. The telescoping technique was initially used (14 initial unilateral transplants), and after October, 2003 it was changed to an end-to-end anastomosis (57 transplants and 93 anastomoses). Results. Eight patients developed bronchial complications including two that were bilateral. There were 4 stenosis, 3 dehiscences, and 3 necrosis complications (9.4%). The complication rate for telescoping anastomosis was 21.4%, and for the end-to-end technique, 7.5%. The treatment of the stenosis used metallic or plastic self-expandable stents. Two bronchial dehiscences resulted in case of bronchopleural fistulae, empyema, and death; the other patient experienced spontaneous resolution. Concerning bronchial necrosis, I patient developed fistulization to the pulmonary artery and massive hemoptysis, and the other with bilateral necrosis, a spontaneous resolution. Conclusion. Our bronchial anastomosis complication rate was comparable with that in other reports. The rate for the telescoping technique was greater compared with the end-to-end technique. The treatment of bronchial stenosis with a self-expandable prosthesis showed good results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess the ability of a three-layer graft in the closuse of large fetal skin defects. Methods: Ovine fetuses underwent a large (4 x 3 cm) full-thickness skin defect over the lumbar region at 105 days` gestation (term = 140 days). A bilaminar artificial skin was placed over a cellulose interface to cover the defect (3-layer graft). The skin was partially reapproximated with a continuous nylon suture. Pregnancy was allowed to continue and the surgical site was submitted to histopathological analysis at different post-operative intervals. Results: Seven fetuses underwent surgery. One maternal/fetal death occurred, and the remaining 6 fetuses were analyzed. Artificial skin adherence to the wound edges was observed in cases that remained in utero for at least 15 days. Neoskin was present beneath the silicone layer of the bilaminar artificial skin. Conclusions: Our study shows that neoskin can develop in the fetus using a 3-layer graft, including epidermal growth beneath the silicone layer of the bilaminar skin graft. These findings suggest that the fetus is able to reepithelialise even large skin defects. Further experience is necessary to assess the quality of this repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dacricistorrinostomia (DCR) endoscópica é uma técnica aceita e bem estabelecida no tratamento de obstruções distais da via lacrimal tornando seu domínio pelos otorrinolaringologistas indispensável. OBJETIVO: O objetivo desse artigo é apresentar a experiência em DCR endoscópica da Divisão de Clínica Otorrinolaringológica do Hospital das Clínicas da USP, comparando com os resultados na literatura. FORMA DE ESTUDO: clínico retrospectivo. MATERIAL E MÉTODO: Foram analisados prontuários de 17 pacientes (17 olhos), submetidos à DCR endoscópica, no período entre abril de 2001 e julho de 2004, na qual foram avaliados com relação a sexo, idade, etiologia, quadro clínico, técnica cirúrgica utilizada, uso de sonda de silicone e tempo de permanência, seguimento e as complicações observadas. RESULTADOS: Oito homens e nove mulheres, com idade variando de 29 a 79 (média: 42,64 13,1) apresentaram um seguimento médio de 15 meses. A causa principal da obstrução foi idiopática (58,8%). A epífora foi a queixa predominante. Em 6 pacientes utilizamos instrumentos motorizados, em um caso utilizamos o Laser Yag e no restante, chisel e martelo. Em todos os casos utilizamos sondas de silicone, por período médio de 7,9 semanas e o sucesso da técnica endonasal foi de 82,3%. CONCLUSÃO: A técnica endoscópica se mostrou uma técnica segura, com uma série de vantagens em relação à técnica externa e, desta forma, oftalmologistas e otorrinolaringologistas devem trabalhar em harmonia para oferecer maiores benefícios aos seus pacientes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Nosso objetivo foi verificar se os resultados com a dacriocistorrinostomia endonasal endoscópica em crianças com obstrução do canal nasolacrimal permitem considerá-la uma alternativa de tratamento aceitável para crianças. FORMA DE ESTUDO: clínico com coorte transversal. MATERIAL E MÉTODO: Vinte e sete dacriocistorrinostomias endonasais endoscópicas foram realizadas em crianças de 2 a 12 anos com obstrução do canal nasolacrimal. Todas as crianças haviam sido tratadas por sondagem lacrimal, sem resultado. A técnica utilizou uncinectomia e uma abertura do saco lacrimal pequena. O seguimento foi de 3 meses. RESULTADOS: Bom resultado foi verificado após 21 cirurgias (77,8% de sucesso). A única complicação verificada foi prolapso da intubação com silicone em 1 caso. CONCLUSÃO: Nossos resultados permitem confirmar a dacriocistorrinostomia endonasal endoscópica como alternativa válida e segura para o tratamento de crianças com obstrução nasolacrimal resistente a sondagens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação tem por finalidade compreender a influência dos tratamentos hidrófugos na secagem do tijolo cerâmico, tendo assentado na realização de ensaios de absorção capilar, permeabilidade ao vapor de água e secagem. Foi inicialmente avaliada a possibilidade de utilização de tijolo cerâmico maciço de três proveniências distintas. Uma destas origens foi a Praça de Touros do Campo Pequeno, em Lisboa, que permitiu estudar quatro tipos distintos de tijolo antigo. As outras duas origens foram as cerâmicas Torreense e de Vale de Gândara, tratando-se portanto neste caso de tijolos de fabrico recente. Os diferentes tipos de tijolo foram caracterizados quanto à sua aparência, morfologia, teor de sal, absorção capilar e comportamento em secagem. O tijolo de Vale de Gândara foi o tipo seleccionado para a aplicação dos tratamentos hidrófugos. Foi detectada a presença de fissuras neste tipo tijolo, tal como em todos os outros tipos caracterizados. Sendo este defeito relevante para o transporte de humidade, foi necessário ter em consideração a influência da orientação preferencial das fissuras. Assim, utilizaram-se em todos os ensaios provetes com fissuras paralelas e provetes com fissuras perpendiculares à superfície. Estudaram-se cinco tratamentos hidrófugos com base em silicone. Foram realizados ensaios de absorção capilar através da face tratada, ensaios de permeabilidade ao vapor de água e ensaios de secagem (método RILEM da curva de evaporação). Realizaram-se ensaios semelhantes sobre o material não-tratado, que serviram como referência. Os resultados do ensaio de absorção capilar indicam que a eficácia de quatro dos tratamentos é elevada, sendo a secagem do tijolo significativamente dificultada por esses quatro produtos. Verificou-se, no entanto, que o decréscimo da permeabilidade ao vapor apenas é significativo para três hidrófugos. A influência dos hidrófugos na permeabilidade ao vapor apenas é mensurável no caso dos provetes com fissuras paralelas à base. Quando as fissuras são perpendiculares à base, a permeabilidade ao vapor é bastante mais elevada, não sendo afectada pelo hidrófugo. Palavras-chave: materiais cerâmicos, hidrófugos, tratamentos à base de hidrófugos, materiais porosos, transporte de humidade, edifícios antigos, secagem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As gestantes, fruto das suas alterações fisiológicas e biomecânicas, constituem uma população de risco relativamente a dores ou lesões do sistema músculo-esquelético, nomeadamente, nos membros inferiores e coluna. Os objectivos deste estudo consistiram em avaliar: (i) a dor e o conforto dos pés durante a marcha: sem o uso de qualquer palmilha nas gestantes e no grupo de controlo; com a aplicação de uma palmilha de retropé e com a aplicação de uma palmilha completa (nas gestantes); (ii) a distribuição das pressões plantares e, (iii) as forças de reacção do solo nas mesmas condições experimentais. Avaliámos ainda a duração das diferentes fases do ciclo de marcha nas gestantes, com e sem palmilhas, e no grupo de controlo, sem o uso de palmilha. Os nossos resultados mostraram que: (i) as gestantes demoram mais tempo a completar a fase de apoio da marcha, (ii) têm um aumento significativo de dores nos pés, face ao grupo de controlo, (iii) as gestantes sentem menos dor e mais conforto quando realizam marcha, com palmilhas, especialmente com a palmilha completa, (iv) a palmilha completa redistribui as forças, diminui os valores de pressão e aumenta a área de contacto do pé com o solo. Os nossos resultados sugerem que, o uso da palmilha completa de silicone, durante a marcha, pode ser eficaz na melhoria da sintomatologia dolorosa e no aumento do conforto da grávida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have developed a new method for single-drop microextraction (SDME) for the preconcentration of organochlorine pesticides (OCP) from complex matrices. It is based on the use of a silicone ring at the tip of the syringe. A 5 μL drop of n-hexane is applied to an aqueous extract containing the OCP and found to be adequate to preconcentrate the OCPs prior to analysis by GC in combination with tandem mass spectrometry. Fourteen OCP were determined using this technique in combination with programmable temperature vaporization. It is shown to have many advantages over traditional split/splitless injection. The effects of kind of organic solvent, exposure time, agitation and organic drop volume were optimized. Relative recoveries range from 59 to 117 %, with repeatabilities of <15 % (coefficient of variation) were achieved. The limits of detection range from 0.002 to 0.150 μg kg−1. The method was applied to the preconcentration of OCPs in fresh strawberry, strawberry jam, and soil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho, cujo objectivo centra-se no desenvolvimento de um sistema primário para medição da densidade absoluta de líquidos, compara resultados obtidos através de diferentes metodologias, no que diz respeito ao valor da incerteza, demonstrando assim, qual o melhor método de pesagem a utilizar. A medição da densidade de líquidos efectua-se através do método da pesagem hidrostática, que consiste em pesar uma esfera de silicone fora do líquido (pesagem no ar) e de seguida pesá-la em suspensão num líquido. Para tal, a balança hidrostática possui um dispositivo que suspende a esfera para a sua imersão no líquido. Também é usado o densímetro digital como método de comparação com a pesagem hidrostática. O padrão de densidade utilizado foi a esfera de silicone pois os cristais de silicone são os melhores materiais, devido à elevada estabilidade na determinação da densidade. A densidade do ar é uma das magnitudes de influência mais comum em metrologia, influenciando diversas áreas de medida, incluindo massa, densidade do líquido, volume, entre outros. Por isso, foi importante determinar a densidade do ar medindo a temperatura, a pressão e a humidade relativa e aplicando a equação CIPM. Para medições de densidade por pesagem hidrostática, a água destilada é o líquido normalmente usado. A densidade da água, ρL, foi determinada pela fórmula M. Tanaka, Fujii e Masui, a uma temperatura de 20⁰C, aproximadamente. Após a determinação da densidade, foi estimada a incerteza associada ao valor da mensuranda, pois é a incerteza que define a qualidade do resultado da densidade. A validação de um resultado, como suporte à decisão, é impossível sem o conhecimento da incerteza associada ao próprio resultado. A fonte de incerteza que mais contribuiu para a incerteza global da densidade do líquido foi a massa da esfera. Considerando que o balanço de incertezas é influenciado por diversos factores inerentes ao próprio método, realizou-se uma abordagem ao desenho de experiências, através da análise de variância (ANOVA), cuja técnica permite determinar quais os parâmetros significativos. A fonte de incerteza que mais contribuiu para a incerteza global da densidade do líquido foi “Entre Ensaios”. Através do método ANOVA, verifica-se também que a amostra líquida é estável e homogénea devido a apresentar uma incerteza pequena.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau académico de Mestre em Engenharia Civil, na especialidade de Reabilitação de Edifícios. A presente dissertação foi preparada no âmbito do Convénio existente entre o Laboratório Nacional de Engenharia Civil(LNEC) e a Faculdade de Ciências e Tecnologia, tendo sido realizada no LNEC