629 resultados para RPM


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Isoamyl butyrate production was investigated using free and immobilized lipases by esterification of butyric acid with isoamyl alcohol in a solvent-free system and in an organic media. Among the enzymes studied, Lipozyme TL IM was found to be the most active catalyst in n-hexane as a solvent. The effects of different solvents and the amount of water added on conversion rates were studied. A maximum conversion yield of 80% in n-hexano at 48 h was obtained under the following conditions: 3 g L-1 of Lipozyme TL IM, 30 ºC, 180 rpm of agitation, isoamyl alcohol to butyric acid molar ratio of 1:1 and acid substrate concentration of 0.06 M.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biospecific affinity chromatography was used to purify three cyclodextrin glycosyl transferases (CGTases) obtained from microorganisms isolated of soil. The cyclodextrins (CDs) production by CGTases was evaluated using starches from different sources. CDs were measured through the Complexation Theory and by HPLC. CGTase from Bacillus firmus strain 7B showed the best production (30 mmol/L of β-CD and 4.3 mmol/L of γ-CD), and its cultivation conditions were optimized. The maximum enzymatic activity was achieved using lung peptone, soluble starch and agitation speed of 160 rpm. Studied CGTases were shown quite interesting for the industrial production of CDs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermophilic Bacillus sp. SMIA-2, produced protease when grown on apple pectic, whey protein and corn step liquor medium, whose concentration was varied from 3 to 10 gL-1, according to the central composite design 2³. The experiments were conducted in shaker, at 50 °C, 150 rpm and initial pH 6.5. The results revealed that the culture medium affected both, cell growth and enzyme production. After graphical and numerical optimization procedure, the enzyme production reached its maximum value at 30 h fermentation, reaching, approximately, 70 U protein mg-1, suggesting that this process was partially associated to the growth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the establishment of dissolution test conditions for 75 mg cinnarizine capsules using a multivariate approach. A 2³ full factorial design was carried out to achieve the best conditions and HCl 0.1 mol L-1 as dissolution medium, basket as apparatus at 100 rpm and collect time at 30 min were considered adequate. The quantification was carried out by spectrophotometry at 251 nm. Both dissolution procedure and analytical method were validated and all parameters were within the acceptable limits. Since there is no official monograph for this pharmaceutical product, this dissolution test could be applied for quality control routine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report results of the efficiency of tungsten extraction from wolframite concentrate (containing 61.5 wt % WO3) from the Igarapé Manteiga mine (state of Rondônia, Brazil) through acid leaching with strong mineral acids at 100 ºC and 400 rpm for 2-4 h. HCl yielded insoluble matter containing the highest WO3 content (90 wt %). This solid was dissolved in concentrated NH3(aq) at 25 ºC and the insoluble matter filtrated. The filtrate was slowly evaporated. 70 wt % of the tungsten present in the starting concentrate material was recovered as ammonium paratungstate (APT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Materials obtained by the immobilization of 12-tungstophosphoric acid (PTA) on silica using the method of impregnation with excess solution in distinct solvents (aqueous HCl, methanol:H2O, and acetonitrile) were evaluated for use as catalysts in the methyl esterification of stearic acid. Optimum conditions were established for the impregnation of 0.5 g (w/w) of PTA on amorphous silica, under stirring at 150 rpm for 24 h, using 20 mL of 0.1 mol L-1 HCl as the solvent. After calcination at 200 ºC, high conversions were obtained under mild reaction conditions, resulting in high turnover numbers. The catalyst was evaluated in ten catalytic cycles of use, where the activity was reduced only slightly, attesting its stability and the possibility to apply it to industrial production of methylesters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aimed to adapt the analysis of methemoglobin recommended by Evelyn - Malloy (visible spectrophotometry), in order to facilitate its application in the field, or to analysis in clinical laboratory, of existing sites of diflubenzuron application. The parameters changed included: centrifuge rotation speed; time between the collection of biological sample and analysis, and storage temperature of the samples; and the volume of reagents. The comparison of the rotation speed (rpm) of the reference methodology with the rpm of a "clinical centrifuge" did not reveal a statistically significant difference in the levels of methemoglobin. The time between the collection of biological sample and analysis was extended for a period of up to 48 hours for both conservation by refrigeration and ambient temperature, producing no statistically significant difference when compared to the standard duration of 2 hours. Regarding the reagents, the reference methodology already uses the volume necessary to ensure complete reaction, whereas a wider range from the recommended volume to a 5-fold reduction in comparison to the reference methodology could be used. It was concluded that the proposed changes to the methodology for adapting the analysis are applicable to studies of field / workplace exposure and ensure the reliability of results. The adapted methodology was inter-laboratory validated and the parameters changed can be selected according to the requirements of the laboratory at which the methemoglobin is to be measured.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the theoretical part, the different polymerisation catalysts are introduced and the phenomena related to mixing in the stirred tank reactor are presented. Also the advantages and challenges related to scale-up are discussed. The aim of the applied part was to design and implement an intermediate-sized reactor useful for scale-up studies. The reactor setting was tested making one batch of Ziegler–Natta polypropylene catalyst. The catalyst preparation with a designed equipment setting succeeded and the catalyst was analysed. The analyses of the catalyst were done, because the properties of the catalyst were compared to the normal properties of Ziegler–Natta polypropylene catalyst. The total titanium content of the catalyst was slightly higher than in normal Ziegler–Natta polypropylene catalyst, but the magnesium and aluminium content of the catalyst were in the normal level. By adjusting the siphonation tube and adding one washing step the titanium content of the catalyst could be decreased. The particle size of the catalyst was small, but the activity was in a normal range. The size of the catalyst particles could be increased by decreasing the stirring speed. During the test run, it was noticed that some improvements for the designed equipment setting could be done. For example more valves for the chemical feed line need to be added to ensure inert conditions during the catalyst preparation. Also nitrogen for the reactor needs to separate from other nitrogen line. With this change the pressure in the reactor can be kept as desired during the catalyst preparation. The proposals for improvements are presented in the applied part. After these improvements are done, the equipment setting is ready for start-up. The computational fluid dynamics model for the designed reactor was provided by cooperation with Lappeenranta University of Technology. The experiments showed that for adequate mixing with one impeller, stirring speed of 600 rpm is needed. The computational fluid dynamics model with two impellers showed that there was no difference in the mixing efficiency if the upper impeller were pumping downwards or upwards.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this thesis is to describe hybrid drive design problems, the advantages and difficulties related to the drive. A review of possible hybrid constructions, benefits of parallel, series and series-parallel hybrids is done. In the thesis analytical and finite element calculations of permanent magnet synchronous machines with embedded magnets were done. The finite element calculations were done using Cedrat’s Flux 2D software. This machine is planned to be used as a motor-generator in a low power parallel hybrid vehicle. The boundary conditions for the design were found from Lucas-TVS Ltd., India. Design Requirements, briefly: • The system DC voltage level is 120 V, which implies Uphase = 49 V (RMS) in a three phase system. • The power output of 10 kW at base speed 1500 rpm (Torque of 65 Nm) is desired. • The maximum outer diameter should not be more than 250 mm, and the maximum core length should not exceed 40 mm. The main difficulties which the author met were the dimensional restrictions. After having designed and analyzed several possible constructions they were compared and the final design selected. Dimensioned and detailed design is performed. Effects of different parameters, such as the number of poles, number of turns and magnetic geometry are discussed. The best modification offers considerable reduction of volume.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to develop and validate simple, accurate and precise spectroscopic methods (multicomponent, dual wavelength and simultaneous equations) for the simultaneous estimation and dissolution testing of ofloxacin and ornidazole tablet dosage forms. The medium of dissolution used was 900 ml of 0.01N HCl, using a paddle apparatus at a stirring rate of 50 rpm. The drug release was evaluated by developed and validated spectroscopic methods. Ofloxacin and ornidazole showed 293.4 and 319.6nm as λmax in 0.01N HCl. The methods were validated to meet requirements for a global regulatory filing. The validation included linearity, precision and accuracy. In addition, recovery studies and dissolution studies of three different tablets were compared and the results obtained show no significant difference among products.