966 resultados para Pump-turbine


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found. © 2012 The Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

http://digitalcommons.colby.edu/atlasofmaine2009/1029/thumbnail.jpg

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project was designed to demonstrate the visibility of potential future wind turbines built on the Colby campus. We conducted viewshed analyses in ArcGIS on three different potential turbine sites to determine the visibility of the turbines within a 10km radius. We found that the Runnals hill turbine would be visible to the largest area and the largest number of residents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a detailed thermodynamic analysis for an extraction-condensation steam turbine capable to drive a 40 MVA electricity generator in a sugar-alcohol factory was carried out. The use of this turbine in the cogeneration system showed that its efficiency contributed to increase the power generation, although the condensation reduces the overall efficiency of the plant. Sensibility analyses were performed to evaluate the behavior of the overall energy efficiency of a plant with the extraction-condensation turbine in function of the boiler efficiency, the specific consumption of steam in the processes and the condensation rate in the turbine. It was observed that the plant efficiency is very sensible to the condensation rate variation and it increases when there is an increase in the demand of steam for processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective - Kidney dysfunction is a common complication after cardiac surgery. It occurs in 7 to 31% of the patients. The lowest haematocrit after cardiopulmonary bypass surgery (LHCT) has been identified as a risk factor for kidney dysfunction after cardiac surgery. The aim of this study is to determine whether different levels of haematocrit during cardiopulmonary bypass surgery are related to kidney dysfunction.Methods and results-A prospective study was conducted on consecutive adult patients undergoing myocardial revascularization. Preoperative renal function was assessed by baseline serum creatinine level (CrPre). Peak postoperative creatinine (CrPost) was defined as the highest daily in-hospital postoperative value. Peak fractional change in creatinine (% Delta Cr) was defined as the difference between the CrPre and CrePost represented as a percentage of the preoperative value. The LHTC was defined as the lowest recorded haematocrit prior to weaning from the initial pump run. A category variable was created for haematocrit based on the distribution of values. The category variable had the following cut-off points: less than 23%, 23.1 to 28% and greater than 28.1 %. Lowest haematocrit (26.62 +/- 4.15%), CPB (74.71 +/- 24.90 min), CrPre (1.23 +/- 0.37 mg/dl) and highest CrPost (1.52 +/- 0.47 mg/dl) data varied in near-normal fashion. Statistical significance has been observed in the < 23% lowest haematocrit group (CrIPOD and Cr5POD; P = 0.006) and the 23.1 28% lowest haematocrit level group (CrPre and Cr2POD; P = 0.047). CrPre and Cr5POD did not differ between groups (P > 0.05). The multiple linear regression model confirmed that the determinants for higher %Delta Cr were age, body surface area and preoperative serum creatinine level.Conclusion - The LHTC was not identified as a risk factor for kidney dysfunction after myocardial revascularization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary excited state absorption processes relating to the (5)I(6) -> (5)I(7) 3 mu m laser transition in singly Ho(3+)-doped fluoride glass have been investigated in detail using time-resolved fluorescence spectroscopy. Selective laser excitation of the (5)I(6) and (5)I(7) energy levels established the occurrence of two excited state absorption transitions from these energy levels that compete with previously described energy transfer upconversion processes. The (5)I(7) -> (5)I(4) excited state absorption transition has peak cross sections at 1216 nm (sigma(esa)=2.8x10(-21) cm(2)), 1174 nm (sigma(esa)=1x10(-21) cm(2)), and 1134 nm (sigma(esa)=7.4x10(-22) cm(2)) which have a strong overlap with the (5)I(8) -> (5)I(6) ground state absorption. on the other hand, it was established that the excited state absorption transition (5)I(6) -> (5)S(2) had a weak overlap with ground state absorption. Using numerical solution of the rate equations, we show that Ho(3+)-doped fluoride fiber lasers employing pumping at 1100 nm rely on excited state absorption from the lowest excited state of Ho(3+) to maintain a population inversion and that energy transfer upconversion processes compete detrimentally with the excited state absorption processes in concentrated Ho(3+)-doped fluoride glass. (c) 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drying kinetics of tomato was studied by using heat pump dryer (HPD) and electric resistance dryers with parallel and crossed airflow. The performance of both systems was evaluated and compared and the influence of temperature, air velocity, and tomato type on the drying kinetics was analyzed. The use of HPD showed to be adequate in the drying process of tomatoes, mainly in relation to the conversion rate of electric energy into thermal energy. The heat pump effective coefficient of performance (COPHT,EF) was between 2.56 and 2.68, with an energy economy of about 40% when compared to the drying system with electric resistance. The Page model could be used to predict drying time of tomato and statistical analysis showed that the model parameters were mainly affected by drying temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility to install a getter vacuum pump and its feasible in the anode of a high-power klystron amplifier is investigated in order to decrease of the pressure in the gun and consequently increasing its lifetime. The study is conducted using a 1.3 GHz, 100 A and 240 kV high-power klystron with five reentrant coaxial cavities, assembled in a cylindrical drift tube 1.2 m long. This work takes into account the specific conductance of components of gun and all important gas sources, like the degassing of the drift tube, the cavity walls, the cathode, the anode, and the collector, as well the position and pumping speed of the getter vacuum pump in anode region. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo desta dissertação é desenvolver uma ferramenta computacional para a análise do potencial de bombeamento de água com base nos valores de velocidades de vento de uma localidade, utilizando um aerogerador de pequeno porte acoplado a um conjunto motobomba convencional, por intermédio de um inversor de frequência. No trabalho são apresentados dois métodos para o cálculo da vazão. O método 1 utiliza um modelo teórico, enquanto que no método 2 o modelamento é feito a partir de dados de bombeamento obtidos em laboratório. Os dois métodos descrevem o funcionamento de um sistema de bombeamento de água envolvendo os equipamentos citados. Utilizando os modelos matemáticos descritos, foi criado um programa em linguagem Delphi®, para a obtenção dos valores de vazão e volume de água bombeada, além do número de pessoas que podem ser atendidas, com base nos dados de velocidade de vento do local, para com isso, ser possível analisar a viabilidade ou não de instalação do sistema. O funcionamento do programa é descrito através de um exemplo, que contém valores reais de velocidade de vento, e cujos resultados são analisados de forma a possibilitar seu entendimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present article is to assess and compare the performance of electricity generation systems integrated with downdraft biomass gasifiers for distributed power generation. A model for estimating the electric power generation of internal combustion engines and gas turbines powered by syngas was developed. First, the model determines the syngas composition and the lower heating value; and second, these data are used to evaluate power generation in Otto, Diesel, and Brayton cycles. Four synthesis gas compositions were tested for gasification with: air; pure oxygen; 60% oxygen with 40% steam; and 60% air with 40% steam. The results show a maximum power ratio of 0.567 kWh/Nm(3) for the gas turbine system, 0.647 kWh/Nm(3) for the compression ignition engine, and 0.775 kWh/Nm(3) for the spark-ignition engine while running on synthesis gas which was produced using pure oxygen as gasification agent. When these three systems run on synthesis gas produced using atmospheric air as gasification agent, the maximum power ratios were 0.274 kWh/Nm(3) for the gas turbine system, 0.302 kWh/Nm(3) for CIE, and 0.282 kWh/Nm(3) for SIE. The relationship between power output and synthesis gas flow variations is presented as is the dependence of efficiency on compression ratios. Since the maximum attainable power ratio of CIE is higher than that of SIE for gasification with air, more research should be performed on utilization of synthesis gas in CIE. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance and emissions behavior of a Rover 1S/60 turboshaft engine when operated with several blends of aviation kerosene and ox tallow ethyl-ester are shown in this article. The tests were performed with a compressor shaft coupled to an hydraulic dynamometer where data of power and mass fuel flow were collected to determine the brake specific fuel consumption. A flue gas analyzer was positioned at the exhaust duct to collect oxygen, carbon dioxide, carbon monoxide and nitrous oxides. An increase in the specific fuel consumption was observed due to the lesser lower heating value of the most oxygenated blends. However, reductions of CO, CO2 and NO (x) have been observed and no-significant ill effects have occurred in the turbine operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiopulmonary bypass (CPB) is often associated with renal dysfunction, as measured by plasma creatinine levels and hemodialysis rates. Aim. To compare creatinine clearance (CrCl), estimated with the Cockroft and Gault formula, between patients undergoing off-pump coronary artery bypass grafting (OPCAB) versus on-pump CABG (on-CAB). Material and methods. Between April 2008 and April 2009, 119 patients underwent coronary bypass graft surgery. Fifty-eight (58) of these patients underwent OPCAB while 61 had on-CAB. Creatinine clearance, plasma creatinine levels, and clinical outcome were compared between the groups. A creatinine clearance value of 50 mL/minute was accepted as the lowest limit of normal renal function. Results. There were two hospital deaths caused by sepses after pulmonary infection. Creatinine clearance (Preoperative OPCAB 73,64±33,72 x on-CAB 75,70±34,30mL/min; discharge OPCAB 75,73±35,07 x on-CAB 79,07±34,71 mL/ min; p=0,609), and creatinine levels (Preoperative OPCAB 1,04±0,38 x on-CAB 1,13±0,53 mg/dL; discharge OPCAB 1,12±0,79 x on-CAB 1,04±0,29mg/dL; p=0,407) did not show statistically inter-group differences. Conclusion. Deterioration in renal function is associated with higher rates of postoperative complications. No significant difference in CrCl could be demonstrated between the groups.