948 resultados para Positron Emission Tomography (PET)
Resumo:
Coupling of cerebral blood flow (CBF) and cerebral metabolic rate for oxygen (CMRO2) in physiologically activated brain states remains the subject of debates. Recently it was suggested that CBF is tightly coupled to oxidative metabolism in a nonlinear fashion. As part of this hypothesis, mathematical models of oxygen delivery to the brain have been described in which disproportionately large increases in CBF are necessary to sustain even small increases in CMRO2 during activation. We have explored the coupling of CBF and oxygen delivery by using two complementary methods. First, a more complex mathematical model was tested that differs from those recently described in that no assumptions were made regarding tissue oxygen level. Second, [15O] water CBF positron emission tomography (PET) studies in nine healthy subjects were conducted during states of visual activation and hypoxia to examine the relationship of CBF and oxygen delivery. In contrast to previous reports, our model showed adequate tissue levels of oxygen could be maintained without the need for increased CBF or oxygen delivery. Similarly, the PET studies demonstrated that the regional increase in CBF during visual activation was not affected by hypoxia. These findings strongly indicate that the increase in CBF associated with physiological activation is regulated by factors other than local requirements in oxygen.
Resumo:
Lesions to left frontal cortex in humans produce speech production impairments (nonfluent aphasia). These impairments vary from subject to subject and performance on certain speech production tasks can be relatively preserved in some patients. A possible explanation for preservation of function under these circumstances is that areas outside left prefrontal cortex are used to compensate for the injured brain area. We report here a direct demonstration of preserved language function in a stroke patient (LF1) apparently due to the activation of a compensatory brain pathway. We used functional brain imaging with positron emission tomography (PET) as a basis for this study.
Resumo:
O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas.
Resumo:
The cyclotron laboratory for radioisotope production and multi-disciplinary research at the Bern University Hospital (Inselspital) is based on an 18-MeV proton accelerator, equipped with a specifically conceived 6-m long external beam line, ending in a separate bunker. This facility allows performing daily positron emission tomography (PET) radioisotope production and research activities running in parallel. Some of the latest developments on accelerator and detector physics are reported. They encompass novel detectors for beam monitoring and studies of low current beams.
Resumo:
Purpose To evaluate the imaging characteristics of a cohort of patients with ocular adnexal lymphoproliferative disease (OALD). Methods A noncomparative retrospective review between 1992 and 1995 and prospective study from 1995 to 2005 of the clinical, imaging and treatment of 105 patients presenting to tertiary orbital referral centre presenting with OALD. Results One hundred and five patients (mean age 61 years, range 11-90 years) with equal gender distribution were included. Fifty-three were primary and 52 were secondary. Computed tomography (CT) usually showed a well-circumscribed lesion of greater than brain density, moulding to adjacent tissues with moderate enhancement. Aggressive histology was associated with bone destruction, while moulding was associated with indolent histology (P < 0.005). MRI in OALD showed intermediate signal intensity on T1- and T2-weighted images and moderate enhancement with gadolinium. Gallium scanning sensitivity to detect ocular adnexal disease was 25 and 57% for systemic involvement. Positron emission tomography (PET) upstaged (71%) of patients with systemic lymphoproliferative involvement, having a higher sensitivity than CT in detecting distant disease (86 vs 72%). Conclusions CT and/ or MRI are essential in the evaluation of OALD and can be used to establish that an orbital lesion may be lymphoprolifetaive in nature. Further, these imaging modalities may predict the behaviour of the lymphoma in certain cases. Gallium scanning provides no additional information to CT and does not influence patient treatment. PET represents an important addition to the assessment of OALD with real impact on patient management.
Resumo:
Functional magnetic resonance imaging (fMRI), positron emission tomography (PET) and magnetoencephalography (MEG) have been the principal neuroimaging tools used to assess the site and nature of cortical deficits in human amblyopia. A review of this growing body of work is presented here with particular reference to various controversial issues, including whether or not the primary visual cortex is dysfunctional, the involvement of higher-order visual areas, neural differences between strabismic and anisometropic amblyopes, and the effects of modern-day drug treatments. We also present our own recent MEG work in which we used the analysis technique of synthetic aperture magnetometry (SAM) to examine the effects of strabismic amblyopia on cortical function. Our results provide evidence that the neuronal assembly associated with form perception in the extrastriate cortex may be dysfunctional in amblyopia, and that the nature of this dysfunction may relate to a change in the normal temporal pattern of neuronal discharges. Based on these results and existing literature, we conclude that a number of cortical areas show reduced levels of activation in amblyopia, including primary and secondary visual areas and regions within the parieto-occipital cortex and ventral temporal cortex. Copyright © 2006 Taylor & Francis Group, LLC.
Resumo:
N-Heterocycles are ubiquitous in biologically active natural products and pharmaceuticals. Yet, new syntheses and modifications of N-heterocycles are continually of interest for the purposes of expanding chemical space, finding quicker synthetic routes, better pharmaceuticals, and even new handles for molecular labeling. There are several iterations of molecular labeling; the decision of where to place the label is as important as of which visualization technique to emphasize.
Piperidine and indole are two of the most widely distributed N-heterocycles and thus were targeted for synthesis, functionalization, and labeling. The major functionalization of these scaffolds should include a nitrogen atom, while the inclusion of other groups will expand the utility of the method. Towards this goal, ease of synthesis and elimination of step-wise transformations are of the utmost concern. Here, the concept of electrophilic amination can be utilized as a way of introducing complex secondary and tertiary amines with minimal operations.
Molecular tags should be on or adjacent to an N-heterocycle as they are normally the motifs implicated at the binding site of enzymes and receptors. The labeling techniques should be useful to a chemical biologist, but should also in theory be useful to the medical community. The two types of labeling that are of interest to a chemist and a physician would be positron emission tomography (PET) and magnetic resonance imaging (MRI).
Coincidentally, the 3-positions of both piperidine and indole are historically difficult to access and modify. However, using electrophilic amination techniques, 3-functionalized piperidines can be synthesized in good yields from unsaturated amines. In the same manner, 3-labeled piperidines can be obtained; the piperidines can either be labeled with an azide for biochemical research or an 18F for PET imaging research. The novel electrophiles, N-benzenesulfonyloxyamides, can be reacted with indole in one of two ways: 3-amidation or 1-amidomethylation, depending on the exact reaction conditions. Lastly, a novel, hyperpolarizable 15N2-labeled diazirine has been developed as an exogenous and versatile tag for use in magnetic resonance imaging.
Resumo:
Obesity is a major challenge to human health worldwide. Little is known about the brain mechanisms that are associated with overeating and obesity in humans. In this project, multimodal neuroimaging techniques were utilized to study brain neurotransmission and anatomy in obesity. Bariatric surgery was used as an experimental method for assessing whether the possible differences between obese and non-obese individuals change following the weight loss. This could indicate whether obesity-related altered neurotransmission and cerebral atrophy are recoverable or whether they represent stable individual characteristics. Morbidly obese subjects (BMI ≥ 35 kg/m2) and non-obese control subjects (mean BMI 23 kg/m2) were studied with positron emission tomography (PET) and magnetic resonance imaging (MRI). In the PET studies, focus was put on dopaminergic and opioidergic systems, both of which are crucial in the reward processing. Brain dopamine D2 receptor (D2R) availability was measured using [11C]raclopride and µ-opioid receptor (MOR) availability using [11C]carfentanil. In the MRI studies, voxel-based morphometry (VBM) of T1-weighted MRI images was used, coupled with diffusion tensor imaging (DTI). Obese subjects underwent bariatric surgery as their standard clinical treatment during the study. Preoperatively, morbidly obese subjects had significantly lower MOR availability but unaltered D2R availability in several brain regions involved in reward processing, including striatum, insula, and thalamus. Moreover, obesity disrupted the interaction between the MOR and D2R systems in ventral striatum. Bariatric surgery and concomitant weight loss normalized MOR availability in the obese, but did not influence D2R availability in any brain region. Morbidly obese subjects had also significantly lower grey and white matter densities globally in the brain, but more focal changes were located in the areas associated with inhibitory control, reward processing, and appetite. DTI revealed also signs of axonal damage in the obese in corticospinal tracts and occipito-frontal fascicles. Surgery-induced weight loss resulted in global recovery of white matter density as well as more focal recovery of grey matter density among obese subjects. Altogether these results show that the endogenous opioid system is fundamentally linked to obesity. Lowered MOR availability is likely a consequence of obesity and may mediate maintenance of excessive energy uptake. In addition, obesity has adverse effects on brain structure. Bariatric surgery however reverses MOR dysfunction and recovers cerebral atrophy. Understanding the opioidergic contribution to overeating and obesity is critical for developing new psychological or pharmacological treatments for obesity. The actual molecular mechanisms behind the positive change in structure and neurotransmitter function still remain unclear and should be addressed in the future research.
Resumo:
BACKGROUND: Histiocytic sarcoma (HS) is a rare hematologic neoplasm with a few hundred cases having been described to date.
Resumo:
Résumé : En imagerie médicale, il est courant d’associer plusieurs modalités afin de tirer profit des renseignements complémentaires qu’elles fournissent. Par exemple, la tomographie d’émission par positrons (TEP) peut être combinée à l’imagerie par résonance magnétique (IRM) pour obtenir à la fois des renseignements sur les processus biologiques et sur l’anatomie du sujet. Le but de ce projet est d’explorer les synergies entre l’IRM et la TEP dans le cadre d’analyses pharmacocinétiques. Plus spécifiquement, d’exploiter la haute résolution spatiale et les renseignements sur la perfusion et la perméabilité vasculaire fournis par l’IRM dynamique avec agent de contraste afin de mieux évaluer ces mêmes paramètres pour un radiotraceur TEP injecté peu de temps après. L’évaluation précise des paramètres de perfusion du radiotraceur devrait permettre de mieux quantifier le métabolisme et de distinguer l’accumulation spécifique et non spécifique. Les travaux ont porté sur deux radiotraceurs de TEP (18F-fluorodésoxyglucose [FDG] et 18F-fluoroéthyle-tyrosine [FET]) ainsi que sur un agent de contraste d’IRM (acide gadopentétique [Gd DTPA]) dans un modèle de glioblastome chez le rat. Les images ont été acquises séquentiellement, en IRM, puis en TEP, et des prélèvements sanguins ont été effectués afin d’obtenir une fonction d’entrée artérielle (AIF) pour chaque molécule. Par la suite, les images obtenues avec chaque modalité ont été recalées et l’analyse pharmacocinétique a été effectuée par régions d’intérêt (ROI) et par voxel. Pour le FDG, un modèle irréversible à 3 compartiments (2 tissus) a été utilisé conformément à la littérature. Pour la FET, il a été déterminé qu’un modèle irréversible à 2 tissus pouvait être appliqué au cerveau et à la tumeur, alors qu’un modèle réversible à 2 tissus convenait aux muscles. La possibilité d’effectuer une conversion d’AIF (sanguine ou dérivée de l’image) entre le Gd DTPA et la FET, ou vice versa, a aussi été étudiée et s’est avérée faisable dans le cas des AIF sanguines obtenues à partir de l’artère caudale, comme c’est le cas pour le FDG. Finalement, l’analyse pharmacocinétique combinée IRM et TEP a relevé un lien entre la perfusion du Gd-DTPA et du FDG, ou de la FET, pour les muscles, mais elle a démontré des disparités importantes dans la tumeur. Ces résultats soulignent la complexité du microenvironnement tumoral (p. ex. coexistence de divers modes de transport pour une même molécule) et les nombreux défis rencontrées lors de sa caractérisation chez le petit animal.
Resumo:
Résumé : Le trouble de l’acquisition de la coordination (TAC), d’étiologie encore indéterminée, est une anomalie neurologique affectant environ 6% des enfants de l'âge scolaire. Le TAC se manifeste essentiellement par un déficit au niveau des exécutions motrices. Le présent travail de recherche comporte deux volets portant sur le TAC. Premièrement, une étude clinique sur 129 sujets âgés de 4 à 18 ans a permis de classifier les caractéristiques du TAC en sous-groupes cliniques. Trente-trois caractéristiques du TAC, les plus fréquemment rapportées dans la littérature, ont été recensées chez nos sujets. L'application d'évaluations statistiques a permis de faire ressortir trois classes essentielles. Le deuxième volet consistait à identifier les régions cérébrales impliquées dans une tâche motrice à l'aide de l'imagerie par la tomographie d'émission par positrons (TEP). Deux sujets avec TAC et deux sujets normaux ont été étudiés en deux séances d'imagerie TEP dont l'une au repos et l'autre en tapotant du pouce sur les doigts de la main gauche non-dominante. Les analyses du premier volet ont montré, entre autres, que le TAC touchait 3.17 garçons pour une fille, que tous les sujets étaient lents, que 47% des sujets étaient gauchers ou ambidextres alors que seulement 10% sont gauchers dans la population générale, que 26% avaient une dyspraxie verbale, et que 83% avaient été diagnostiqués anxieux. Les sujets ont été classés en trois sous-groupes: 1- maladroits et autres caractéristiques, sans problème de langage; 2- trouble de l’estime de soi et relation avec les pairs; 3- difficulté de langage. En imagerie, les structures cérébrales ont été classées selon leur captation du 18F-fluorodesoxyglucose (FDG) dans les hémisphères droit et gauche, avant et après l'activation, et en comparaison avec les sujets normaux. Trois types de structures cérébrales sont ressortis avec les statistiques: des structures activées, celles relativement non sollicitées et des structures désactivées. Il y avait plus de variations dans la captation du FDG chez les sujets avec TAC que chez les normaux. En conclusion, la caractérisation des sujets avec TAC par le diagnostic clinique et par l'imagerie peut procurer un plan de thérapie adéquat et ciblé étant donné que le TAC a un large spectre et pourrait coexister avec d'autres déficits cérébraux.
Resumo:
Résumé : Les performances de détecteurs à scintillation, composés d’un cristal scintillateur couplé à un photodétecteur, dépendent de façon critique de l’efficacité de la collecte et de l’extraction des photons de scintillation du cristal vers le capteur. Dans les systèmes d’imagerie hautement pixellisés (e.g. TEP, TDM), les scintillateurs doivent être arrangés en matrices compactes avec des facteurs de forme défavorables pour le transport des photons, au détriment des performances du détecteur. Le but du projet est d’optimiser les performances de ces détecteurs pixels par l'identification des sources de pertes de lumière liées aux caractéristiques spectrales, spatiales et angulaires des photons de scintillation incidents sur les faces des scintillateurs. De telles informations acquises par simulation Monte Carlo permettent une pondération adéquate pour l'évaluation de gains atteignables par des méthodes de structuration du scintillateur visant à une extraction de lumière améliorée vers le photodétecteur. Un plan factoriel a permis d'évaluer la magnitude de paramètres affectant la collecte de lumière, notamment l'absorption des matériaux adhésifs assurant l'intégrité matricielle des cristaux ainsi que la performance optique de réflecteurs, tous deux ayant un impact considérable sur le rendement lumineux. D'ailleurs, un réflecteur abondamment utilisé en raison de ses performances optiques exceptionnelles a été caractérisé dans des conditions davantage réalistes par rapport à une immersion dans l'air, où sa réflectivité est toujours rapportée. Une importante perte de réflectivité lorsqu'il est inséré au sein de matrices de scintillateurs a été mise en évidence par simulations puis confirmée expérimentalement. Ceci explique donc les hauts taux de diaphonie observés en plus d'ouvrir la voie à des méthodes d'assemblage en matrices limitant ou tirant profit, selon les applications, de cette transparence insoupçonnée.
Resumo:
Introduction: PET-FDG and USPIO-enhanced MRI are increasingly being used in depicting carotid atheroma inflammation - a risk factor for the high risk plaque. Their combined use has not been previously reported. Report: Two patients presenting with stroke and identified with 50% carotid stenosis on duplex ultrasonography, underwent PET FDG and USPIO-enhanced MR imaging. Results were concordant and complementary suggesting that both techniques reflect similar metabolic processes. Discussion: The selection of patients for carotid revascularisation has largely been based on the severity of luminal stenosis alone. The two imaging modalities, which identify inflammatory activity, may be potential surrogate risk markers in the selection of patients eligible for carotid surgery, if plaque inflammation can be correlated with risk of developing clinical symptoms.
Resumo:
Cannabinoid receptors are members of the large family of G-protein coupled receptors. Two types of cannabinoid receptor have been discovered: CB1 and CB2. CB1 receptors are localised predominantly in the brain whereas CB2 receptors are more abundant in peripheral nervous system cells. CB1 receptors have been related with a number of disorders, including depression, anxiety, stress, schizophrenia, chronic pain and obesity. For this reason, several cannabinoid ligands were developed as drug candidates. Among these ligands, a prominent position is occupied by SR141716 (Rimonabant), which is a pyrazole derivative with inverse agonist activity discovered by Sanofi-Synthelabo in 1994. This compound was marketed in Europe as an anti-obesity drug, but subsequently withdrawn due to its side-effects. Since the relationship between the CB1 receptors’ functional modification, density and distribution, and the beginning of a pathological state is still not well understood, the development of radio-ligands suitable for in vivo PET (Positron Emission Tomography) functional imaging of CB1 receptors remains an important area of research in medicine and drug development. To date, a few radiotracers have been synthesised and tested in vivo, but most of them afforded unsatisfactory brain imaging results. A handful of radiolabelled CB1 PET ligands have also been submitted to clinical trials in humans. In this PhD Thesis the design, synthesis and characterization of three new classes of potential high-affinity CB1 ligands as candidate PET tracers is described.