966 resultados para PERSISTENT LUMINESCENCE
Resumo:
Electrokinetics has emerged as a potential technique for in situ soil remediation and especially unique because of the ability to work in low permeability soil. In electrokinetic remediation, non-polar contaminants like most organic compounds are transported primarily by electroosmosis, thus the process is effective only if the contaminants are soluble in pore fluid. Therefore, enhancement is needed to improve mobility of these hydrophobic compounds, which tend to adsorb strongly to the soil. On the other hand, as a novel and rapidly growing science, the applications of ultrasound in environmental technology hold a promising future. Compared to conventional methods, ultrasonication can bring several benefits such as environmental friendliness (no toxic chemical are used or produced), low cost, and compact instrumentation. It also can be applied onsite. Ultrasonic energy applied into contaminated soils can increase desorption and mobilization of contaminants and porosity and permeability of soil through developing of cavitation. The research investigated the coupling effect of the combination of these two techniques, electrokinetics and ultrasonication, in persistent organic pollutant removal from contaminated low permeability clayey soil (with kaolin as a model medium). The preliminary study checked feasibility of ultrasonic treatment of kaolin highly contaminated by persistent organic pollutants (POPs). The laboratory experiments were conducted in various conditions (moisture, frequency, power, duration time, initial concentration) to examine the effects of these parameters on the treatment process. Experimental results showed that ultrasonication has a potential to remove POPs, although the removal efficiencies were not high with short duration time. The study also suggested intermittent ultrasonication over longer time as an effective means to increase the removal efficiencies. Then, experiments were conducted to compare the performances among electrokinetic process alone and electrokinetic processes combined with surfactant addition and mainly with ultrasonication, in designed cylinders (with filtercloth separating central part and electrolyte parts) and in open pans. Combined electrokinetic and ultrasonic treatment did prove positive coupling effect compared to each single process alone, though the level of enhancement is not very significant. The assistance of ultrasound in electrokinetic remediation can help reduce POPs from clayey soil by improving the mobility of hydrophobic organic compounds and degrading these contaminants through pyrolysis and oxidation. Ultrasonication also sustains higher current and increases electroosmotic flow. Initial contaminant concentration is an essential input parameter that can affect the removal effectiveness.
Resumo:
Responses evoked in the earthworm, Amynthas hawayanus, main muscle contraction generator M-2 (postsynaptic mechanical-stimulus-sensitive) neuron by threshold mechanical stimuli in 2-s intertrial intervals (ITI) were used as the control or unconditioned responses (UR). Their attenuation induced by decreasing these intervals in non-associative conditioning and their enhancement induced by associating the unconditioned stimuli (US) to a train of short (0.1 s) hyperpolarizing electrical substitutive conditioning stimuli (SCS) in the Peri-Kästchen (PK) neuron were measured in four parameters, i.e., peak numbers (N) and amplitude ()averaged from 120 responses, sum of these amplitudes (SAMP) and the highest peak amplitude (V) over a period of 4 min. Persistent attenuation similar to habituation was induced by decreasing the control ITI to 0.5 s and 2.0 s in non-associative conditioning within less than 4 min. Dishabituation was induced by randomly pairing one of these habituated US to an electrical stimulus in the PK neuron. All four parameters of the UR were enhanced by forward (SCS-US), but not backward (US-SCS), association of the US with 25, 100 and 250-Hz trains of SCS with 40-ms interstimulus intervals (ISI) for 4 min and persisted for another 4 min after turning off the SCS. The enhancement of these parameters was proportional to the SCS frequencies in the train. No UR was evoked by the SCS when the US was turned off after 4 min of classical conditioning.
Resumo:
Measuring protein biomarkers from sample matrix, such as plasma, is one of the basic tasks in clinical diagnostics. Bioanalytical assays used for the measuring should be able to measure proteins with high sensitivity and specificity. Furthermore, multiplexing capability would also be advantageous. To ensure the utility of the diagnostic test in point-of-care setting, additional requirements such as short turn-around times, ease-ofuse and low costs need to be met. On the other hand, enhancement of assay sensitivity could enable exploiting novel biomarkers, which are present in very low concentrations and which the current immunoassays are unable to measure. Furthermore, highly sensitive assays could enable the use of minimally invasive sampling. In the development of high-sensitivity assays the label technology and affinity binders are in pivotal role. Additionally, innovative assay designs contribute to the obtained sensitivity and other characteristics of the assay as well as its applicability. The aim of this thesis was to study the impact of assay components on the performance of both homogeneous and heterogeneous assays. Applicability of two different lanthanide-based label technologies, upconverting nanoparticles and switchable lanthanide luminescence, to protein detection was explored. Moreover, the potential of recombinant antibodies and aptamers as alternative affinity binders were evaluated. Additionally, alternative conjugation chemistries for production of the labeled binders were studied. Different assay concepts were also evaluated with respect to their applicability to point-of-care testing, which requires simple yet sensitive methods. The applicability of upconverting nanoparticles to the simultaneous quantitative measurement of multiple analytes using imaging-based detection was demonstrated. Additionally, the required instrumentation was relatively simple and inexpensive compared to other luminescent lanthanide-based labels requiring time-resolved measurement. The developed homogeneous assays exploiting switchable lanthanide luminescence were rapid and simple to perform and thus applicable even to point-ofcare testing. The sensitivities of the homogeneous assays were in the picomolar range, which are still inadequate for some analytes, such as cardiac troponins, requiring ultralow limits of detection. For most analytes, however, the obtained limits of detection were sufficient. The use of recombinant antibody fragments and aptamers as binders allowed site-specific and controlled covalent conjugation to construct labeled binders reproducibly either by using chemical modification or recombinant technology. Luminescent lanthanide labels were shown to be widely applicable for protein detection in various assay setups and to contribute assay sensitivity.
Resumo:
We describe the ultrastructural abnormalities of the small bowel surface in 16 infants with persistent diarrhea. The age range of the patients was 2 to 10 months, mean 4.8 months. All patients had diarrhea lasting 14 or more days. Bacterial overgrowth of the colonic microflora in the jejunal secretion, at concentrations above 10(4) colonies/ml, was present in 11 (68.7%) patients. The stool culture was positive for an enteropathogenic agent in 8 (50.0%) patients: for EPEC O111 in 2, EPEC O119 in 1, EAEC in 1, and Shigella flexneri in 1; mixed infections due to EPEC O111 and EAEC in 1 patient, EPEC O119 and EAEC in 1 and EPEC O55, EPEC O111, EAEC and Shigella sonnei in 1. Morphological abnormalities in the small bowel mucosa were observed in all 16 patients, varying in intensity from moderate 9 (56.3%) to severe 7 (43.7%). The scanning electron microscopic study of small bowel biopsies from these subjects showed several surface abnormalities. At low magnification (100X) most of the villi showed mild to moderate stunting, but on several occasions there was subtotal villus atrophy. At higher magnification (7,500X) photomicrographs showed derangement of the enterocytes; on several occasions the cell borders were not clearly defined and very often microvilli were decreased in number and height; in some areas there was a total disappearance of the microvilli. In half of the patients a mucus-fibrinoid pseudomembrane was seen partially coating the enterocytes, a finding that provides additional information on the pathophysiology of persistent diarrhea.
Resumo:
Trials have demonstrated that high-dose escalation followed by autologous transplantation can promote better long-term survival as salvage treatment in malignant lymphomas. The aim of the present nonrandomized clinical trial was to demonstrate the role of high-dose cyclophosphamide (HDCY) in reducing tumor burden and also to determine the effectiveness of HDCY followed by etoposide (VP-16) and methotrexate (MTX) in Hodgkin's disease plus high-dose therapy with peripheral blood progenitor cell (PBPC) transplantation as salvage treatment. From 1998 to 2000, 33 patients with a median age of 33 years (13-65) affected by aggressive non-Hodgkin's lymphoma (NHL) (60.6%) or persistent or relapsed Hodgkin's disease (39.4%) were enrolled and treated using high dose escalation (HDCY + HDVP-16 plus HDMTX in Hodgkin's disease) followed by autologous PBPC transplantation. On an "intention to treat" basis, 33 patients with malignant lymphomas were evaluated. The overall median follow-up was 400 days (40-1233). Thirty-one patients underwent autografting and received a median of 6.19 x 10(6)/kg (1.07-29.3) CD34+ cells. Patients who were chemosensitive to HDCY (N = 22) and patients who were chemoresistant (N = 11) presented an overall survival of 96 and 15%, respectively (P<0.0001). Overall survival was 92% for chemosensitive patients and 0% for patients who were still chemoresistant before transplantation (P<0.0001). Toxicity-related mortality was 12% (four patients), related to HDCY in two cases and to transplant in the other two. HDCY + HDVP-16 plus HDMTX in only Hodgkin's disease followed by autologous PBPC proved to be effective and safe as salvage treatment for chemosensitive patients affected by aggressive NHL and Hodgkin's disease, with acceptable mortality rates related to sequential treatment.
Resumo:
This thesis describes the occurrence and sources of selected persistent organic pollutants (POPs) such as polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and hexachlorocyclohexanes (HCHs) in the northern watershed of Lake Victoria. Sediments and fish were collected from three highly polluted embayments (i.e. Murchison Bay, Napoleon Gulf and Thurston Bay) of the lake. The analysis for PCDD/Fs, PCBs and PBDEs was done using a high resolution mass spectrometer coupled to a gas chromatograph (GC), and a GC equipped with an electron capture detector was used for HCHs. Total (Σ) PCDD/Fs, PCBs and PBDEs in sediments ranged from 3.19 to 478, 313 to 4325 and 60.8 to 179 pg g-1 dry weight (dw), respectively. The highest concentrations of pollutants were found at sites close to industrial areas and wastewater discharge points. The maximum concentrations of PCDD/Fs, PCBs, PBDEs and HCHs in fish muscle homogenates were 49, 779, 495 and 45,900 pg g-1 wet weight (ww), respectively. The concentrations of the pollutants in Nile perch (Lates niloticus) were significantly greater than those in Nile tilapia (Oreochromis niloticus), possibly due to differences in trophic level and dietary feeding habits among fish species. World Health Organization-toxic equivalency quotient (WHO2005-TEQ) values in the sediments were up to 4.24 pg g-1 dw for PCDD/Fs and 0.55 pg TEQ g-1 dw for the 12 dioxin-like PCBs (dl-PCBs). 23.1% of the samples from the Napoleon Gulf were above the interim sediment quality guideline value of 0.85 pg WHO-TEQ g-1 dw set by the Canadian Council for Ministers of the Environment. The WHO2005-TEQs in fish were 0.001-0.16 pg g-1 for PCDD/Fs and 0.001-0.31 pg g-1 ww for dl- PCBs. The TEQ values were within a permissible level of 3.5 pg g−1 ww recommended by the European Commission. Based on the Commission set TEQs and minimum risk level criteria formulated by the Agency for Toxic Substances and Disease Registry, the consumption of fish from Lake Victoria gives no indication of health risks associated to PCDD/Fs and PCBs. Principal component analysis (PCA) indicated that anthropogenic activities such as agricultural straw open burning, medical waste incinerators and municipal solid waste combustors were the major sources of PCDD/Fs in the watershed of Lake Victoria. The ratios of α-/γ-HCH varied from 0.89 to 1.68 suggesting that the highest HCH residues mainly came from earlier usage and fresh γ-HCH (lindane). In the present study, the concentration of POPs in fish were not significantly related to those in sediments, and the biota sediment accumulation factor (BSAF) concept was found to be a poor predictor of the bioavailability and bioaccumulation of environmental pollutants.
Resumo:
Asthma is an inflammatory condition characterized by the involvement of several mediators, including reactive oxygen species. The aim of the present study was to investigate the superoxide release and cellular glutathione peroxidase (cGPx) activity in peripheral blood granulocytes and monocytes from children and adolescents with atopic asthma. Forty-four patients were selected and classified as having intermittent or persistent asthma (mild, moderate or severe). The spontaneous or phorbol myristate acetate (PMA, 30 nM)-induced superoxide release by granulocytes and monocytes was determined at 0, 5, 15, and 25 min. cGPx activity was assayed spectrophotometrically. The spontaneous superoxide release by granulocytes from patients with mild (N = 15), moderate (N = 12) or severe (N = 6) asthma was higher at 25 min compared to healthy individuals (N = 28, P < 0.05, Duncan test). The PMA-induced superoxide release by granulocytes from patients with moderate (N = 12) or severe (N = 6) asthma was higher at 15 and 25 min compared to healthy individuals (N = 28, P < 0.05 in both times of incubation, Duncan test). The spontaneous or PMA-induced superoxide release by monocytes from asthmatic patients was similar to healthy individuals (P > 0.05 in all times of incubation, Duncan test). cGPx activity of granulocytes and monocytes from patients with persistent asthma (N = 20) was also similar to healthy individuals (N = 10, P > 0.05, Kruskal-Wallis test). We conclude that, under specific circumstances, granulocytes from children with persistent asthma present a higher respiratory burst activity compared to healthy individuals. These findings indicate a risk of oxidative stress, phagocyte auto-oxidation, and the subsequent release of intracellular toxic oxidants and enzymes, leading to additional inflammation and lung damage in asthmatic children.
Resumo:
Escherichia coli K-12 (pEGFPluxABCDEAmp) (E. coli-lux), constitutively emitting bioluminescence (BL), was constructed and its BL emitting properties tested in different growth and killing conditions. The BL emission directly correlated with the number of viable E. coli-lux cells, and when subjected to the antimicrobial agent, the diminishment of the BL signal was linked directly to the number of killed bacterial cells. The method provided a very convenient application, especially when compared to conventional plate counting assays. This novel real-time based method was utilized in both immunological and toxicological assessments. The parameters such as the activation phase, the lytic phase and the capacity of the killing of the serum complement system were specified not only in humans but also in other species. E. coli-lux was also successfully used to study the antimicrobial activities of insect haemolymph. The mechanisms of neutrophil activity, like that of a myeloperoxidase (MPO)-H2O2-halide system, were studied using the E. coli-lux approach. The fundamental role of MPO was challenged, since during the actual killing in described circumstances in phagolysosome the MPO system was inactivated and chlorination halted. The toxicological test system, assessing indoor air total toxicity, particularly suitable for suspected mold damages, was designed based on the E. coli-lux method. Susceptibility to the vast number of various toxins, both pure chemicals and dust samples from the buildings and extracts from molds, were investigated. The E. coli-lux application was found to possess high sensitivity and specificity attributes. Alongside the analysis system, the sampling kit for indoor dust was engineered based on the swipe stick and the container. The combination of practical specimen collector and convenient analysis system provided accurate toxic data from the dust sample within hours. Neutrophils are good indicators of the pathophysiological state of the individual, and they can be utilized as a toxicological probe due to their ability to emit chemiluminescence (CL). Neutrophils can either be used as probe cells, directly exposed to the agent studied, or they can act as indicators of the whole biological system exposed to the agent. Human neutrophils were exposed to the same toxins as tested with the E. coli-lux system and measured as luminol amplified CL emission. The influence of the toxins on the individuals was investigated by exposing rats with moniliniformin, the mycotoxin commonly present in Finnish grains. The activity of the rat neutrophils was found to decrease significantly during the 28 days of exposure.
Resumo:
We evaluated the recovery of cardiovascular function after transient cardiogenic shock. Cardiac tamponade was performed for 1 h and post-shock data were collected in 5 domestic large white female pigs (43 ± 5 kg) for 6 h. The control group (N = 5) was observed for 6 h after 1 h of resting. During 1 h of cardiac tamponade, experimental animals evolved a low perfusion status with a higher lactate level (8.0 ± 2.2 vs 1.9 ± 0.9 mEq/L), lower standard base excess (-7.3 ± 3.3 vs 2.0 ± 0.9 mEq/L), lower urinary output (0.9 ± 0.9 vs 3.0 ± 1.4 mL·kg-1·h-1), lower mixed venous saturation, higher ileum partial pressure of CO2-end tidal CO2 (EtCO2) gap and a lower cardiac index than the control group. Throughout the 6-h recovery phase after cardiac tamponade, tamponade animals developed significant tachycardia with preserved cardiac index, resulting in a lower left ventricular stroke work, suggesting possible myocardial dysfunction. Vascular dysfunction was present with persistent systemic hypotension as well as persistent pulmonary hypertension. In contrast, oliguria, hyperlactatemia and metabolic acidosis were corrected by the 6th hour. The inflammatory characteristics were an elevated core temperature and increased plasma levels of interleukin-6 in the tamponade group compared to the control group. We conclude that cardiovascular recovery after a transient and severe low flow systemic state was incomplete. Vascular dysfunction persisted up to 6 h after release of tamponade. These inflammatory characteristics may also indicate that inflammatory activation is a possible pathway involved in the pathogenesis of cardiogenic shock.
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
Ce travail est axé vers la compréhension détaillée des propriétés de luminescence de composés de certains métaux lourds. La première partie de ce mémoire décrit la caractérisation spectroscopique d'un radical de type nitronyle nitroxyde, 2-(2-pyridinyl)-4,4,5,5-tétraméthyl-4,5-dihydro-1H-imidazolyl-1-oxyl-3-oxyde, abrégé (NIT2-Py), et de ses complexes avec les cations Tb(III), [Tb(hfac)3NIT2-Py], et Y(III), [Y(hfac)3NIT2-Py]. La variation de la température affecte les spectres de luminescence qui montrent de la structure vibronique résolue. Les maxima de ces transitions vibroniques se rapprochent au fur et à mesure que la température augmente. Ces variations des maxima en fonction de la température ne correspondent pas à des variations de fréquences vibrationnelles et sont de l'ordre de 200 cm-1 entre 80 K et 240 K. La variation de la température n'a pas d'influence significative sur la structure moléculaire, comme atteste la variation mineure des maxima des spectres Raman entre 80 K et 300 K. La comparaison des spectres expérimentaux à des spectres calculés montre que ces variations peuvent être reproduites par l'utilisation d'une combinaison de fréquences vibrationnelles. Le paramètre dont la variation est très significative est la résolution du spectre de luminescence, représentée par la largeur à mi-hauteur des transitions vibroniques qui forment le spectre de luminescence. La deuxième partie de ce mémoire décrit les propriétés de luminescence d'une série de complexes d’or(I). Elles sont comparées aux changements structuraux à pression et température variable. Les interactions aurophiles ont une grande influence sur la luminescence. La variation de la température et de la pression est une approche efficace pour varier la luminescence. Les effets observés dans les spectres d'émission de ces complexes dépendent des changements de structure induits par variation de la température et de la pression. Ces petites variations structurales mènent à des changements importants, à titre d'exemple à un déplacement du maximum de la bande de luminescence de 60 cm-1/ kbar vers les faibles énergies pour un des complexes de l'or(I) étudiés au cours de ce projet.
Resumo:
The thesis entitled “ Investigations on the solvent extraction and luminescence of lanthanoids with mixtures of heterocyclic β-diketone S and various neutral oxo-donors” embodies the results of investigations carried out on the solvent extraction of trivalent lanthanoids with various heterocyclic β-diketones in the presence and absence of neutral oxo-donors and also on the luminescent studies of Eu3+-heterocyclic β-diketonate complexes with Lewis bases. The primary objective of the present work is to generate the knowledge base, especially to understand the interactions of lanthanoid-heterocyclic β-diketonates with various macrocyclic ligands such as crown ethers and neutral organophosphorus extractants , with a view to achieve better selectivity. The secondary objective of this thesis is to develop novel lanthanoid luminescent materials based on 3-phenyl-4-aroyl-5-isoxazolones and organophosphorus ligands, for use in electroluminescent devices. In the beginning it describes the need for the development of new mixed-ligand systems for the separation of lanthanoids and the development and importance of novel luminescent lanthanoid- β-diketonate complexes for display devices. The syntheses of various para substituted derivatives of 4-aroyl-5-isoxazolones and their characterization by various spectroscopic techniques are described. It also investigate the solvent extraction behaviour of trivalent lanthanoids with 4-aroyl-5-isoxazolones in the presence and absence of various crown ethers such as 18C6, DC18C6, DB18C6 and B18C6. Elemental analysis, IR and H NMR spectral studies are used to understand the interactions of crown ethers with 4-aroyl-5-isoxazolonate complexes of lanthanoids. The synergistic extraction of trivalent lanthanoids with sterically hindered 1-phenyl-3-methyl-4-pivaloyl-5-pyrazolone in the presence of various structurally related crown ethers are studied. The syntheses, characterization and photyphysical properties of Eu3+-4-aroyl-5-isoxazolonate complexes in the presence of Lewis bases like trictylphosphine oxide or triphenylphosphine oxide were studied.
Resumo:
Highly transparent, luminescent and biocompatible ZnO quantum dots were prepared in water, methanol, and ethanol using liquid-phase pulsed laser ablation technique without using any surfactant. Transmission electron microscopy analysis confirmed the formation of good crystalline ZnO quantum dots with a uniform size distribution of 7 nm. The emission wavelength could be varied by varying the native defect chemistry of ZnO quantum dots and the laser fluence. Highly luminescent nontoxic ZnO quantum dots have exciting application potential as florescent probes in biomedical applications.
Resumo:
In this article we present the spectral and nonlinear optical properties of ZnO–TiO2 nanocomposites prepared by colloidal chemical synthesis. Emission peaks of ZnO–TiO2 nanocomposites change from 340 nm to 385 nm almost in proportion to changes in Eg. The nanocomposites show self-defocusing nonlinearity and good nonlinear absorption behaviour. The nonlinear refractive index and the nonlinear absorption increase with increasing TiO2 volume fraction at 532 nm and can be attributed to the enhancement of exciton oscillator strength. ZnO–TiO2 is a potential nanocomposite material for the tunable light emission and for the development of nonlinear optical devices with a relatively small limiting threshold