990 resultados para Onlay bone graft


Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report the application of a novel scaffold design in a sheep thoracic spine model for spine deformity correction. The combination of the calcium-phosphate coated polycaprolactone scaffolds with recombinant human bone morphogenic protein-2 (rhBMP-2) are intended as a future bone graft substitute in ensuring the stability of bony intervertebral fusion. A solid free-form fabrication process based on melt extrusion has been utilized in the manufacturing of these scaffolds. To date there are no studies examining the use of such biodegradable implants in a sheep thoracic spine model. The success of anterior scoliosis surgery in humans depends on achieving a solid bony fusion between adjacent vertebrae after the intervertebral discs have been surgically cleared and the disc spaces filled with graft material. Due to limited availability of autograft, there is much current interest in the development of synthetic scaffolds in combination with growth factors such as recombinant human bone morphogenetic protein (rhBMP-2) to achieve a solid bony fusion following scoliosis surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Study Design. A sheep study designed to compare the accuracy of static radiographs, dynamic radiographs, and computed tomographic (CT) scans for the assessment of thoracolumbar facet joint fusion as determined by micro-CT scanning. Objective. To determine the accuracy and reliability of conventional imaging techniques in identifying the status of thoracolumbar (T13-L1) facet joint fusion in a sheep model. Summary of Background Data. Plain radiographs are commonly used to determine the integrity of surgical arthrodesis of the thoracolumbar spine. Many previous studies of fusion success have relied solely on postoperative assessment of plain radiographs, a technique lacking sensitivity for pseudarthrosis. CT may be a more reliable technique, but is less well characterized. Methods. Eleven adult sheep were randomized to either attempted arthrodesis using autogenous bone graft and internal fixation (n = 3) or intentional pseudarthrosis (IP) using oxidized cellulose and internal fixation (n = 8). After 6 months, facet joint fusion was assessed by independent observers, using (1) plain static radiography alone, (2) additional dynamic radiographs, and (3) additional reconstructed spiral CT imaging. These assessments were correlated with high-resolution micro-CT imaging to predict the utility of the conventional imaging techniques in the estimation of fusion success. Results. The capacity of plain radiography alone to correctly predict fusion or pseudarthrosis was 43% and was not improved using plain radiography and dynamic radiography with also a 43% accuracy. Adding assessment by reformatted CT imaging to the plain radiography techniques increased the capacity to predict fusion outcome to 86% correctly. The sensitivity, specificity, and accuracy of static radiography were 0.33, 0.55, and 0.43, respectively, those of dynamic radiography were 0.46, 0.40, and 0.43, respectively, and those of radiography plus CT were 0.88, 0.85, and 0.86, respectively. Conclusion. CT-based evaluation correlated most closely with high-resolution micro-CT imaging. Neither plain static nor dynamic radiographs were able to predict fusion outcome accurately. © 2012 Lippincott Williams & Wilkins.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reconstruction of large defects (>10 mm) in humans usually relies on bone graft transplantation. Limiting factors include availability of graft material, comorbidity, and insufficient integration into the damaged bone. We compare the gold standard autograft with biodegradable composite scaffolds consisting of medical-grade polycaprolactone and tricalcium phosphate combined with autologous bone marrow-derived mesenchymal stem cells (MSCs) or recombinant human bone morphogenetic protein 7 (rhBMP-7). Critical-sized defects in sheep - a model closely resembling human bone formation and structure - were treated with autograft, rhBMP-7, or MSCs. Bridging was observed within 3 months for both the autograft and the rhBMP-7 treatment. After 12 months, biomechanical analysis and microcomputed tomography imaging showed significantly greater bone formation and superior strength for the biomaterial scaffolds loaded with rhBMP-7 compared to the autograft. Axial bone distribution was greater at the interfaces. With rhBMP-7, at 3 months, the radial bone distribution within the scaffolds was homogeneous. At 12 months, however, significantly more bone was found in the scaffold architecture, indicating bone remodeling. Scaffolds alone or with MSC inclusion did not induce levels of bone formation comparable to those of the autograft and rhBMP-7 groups. Applied clinically, this approach using rhBMP-7 could overcome autograft-associated limitations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis is a complex three dimensional deformity affecting 2-3% of the general population. Resulting spine deformities include progressive coronal curvature, hypokyphosis, or frank lordosis in the thoracic spine and vertebral rotation in the axial plane with posterior elements turned into the curve concavity. The potential for curve progression is heightened during the adolescent growth spurt. Success of scoliosis deformity correction depends on solid bony fusion between adjacent vertebrae after the intervertebral discs have been surgically cleared and the disc spaces filled with graft material. Problems with bone graft harvest site morbidity as well as limited bone availability have led to the search for bone graft substitutes. Recently, a bioactive and resorbable scaffold fabricated from medical grade polycaprolactone (PCL) has been developed for bone regeneration at load bearing sites. Combined with recombinant human bone morphogenic protein–2 (rhBMP-2), this has been shown to be successful in acting as a bone graft substitute in acting as a bone graft substitute in a porcine lumbar interbody fusion model when compared to autologous bone graft. This in vivo sheep study intends to evaluate the suitability of a custom designed medical grade PCL scaffold in combination with rhBMP-2 as a bone graft substitute in the setting of mini–thoracotomy surgery as a platform for ongoing research to benefit patients with adolescent idiopathic scoliosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction. We develop a sheep thoracic spine interbody fusion model to study the suitability of polycaprolactone-based scaffold and recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute within the thoracic spine. The surgical approach is a mini- open thoracotomy with relevance to minimally invasive deformity correction surgery for adolescent idiopathic scoliosis. To date there are no studies examining the use of this biodegradable implant in combination with biologics in a sheep thoracic spine model. Methods. In the present study, six sheep underwent a 3-level (T6/7, T8/9 and T10/11) discectomy with randomly allocated implantation of a different graft substitute at each of the three levels; (i) calcium phosphate (CaP) coated polycaprolactone based scaffold plus 0.54µg rhBMP-2, (ii) CaP coated PCL- based scaffold alone or (iii) autograft (mulched rib head). Fusion was assessed at six months post-surgery. Results. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL- based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluations of the respective groups. Biomechanical testing revealed significantly higher stiffness for the rhBMP-2 plus PCL- based scaffold group in all loading directions in comparison to the other two groups. Conclusions. The results of this study demonstrate that rhBMP-2 plus PCL-based scaffold is a viable bone graft substitute, providing an optimal environment for thoracic interbody spinal fusion in a large animal model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis represents a step forward in the development of a pre-clinical model investigating a suitable substitute for host bone for use in human spinal fusion. By way of an animal model, it examines the biological performance of a novel bone graft substitute comprised of a combination of a custom-designed biodegradable material and biologics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The transplantation of autologous bone graft as a treatment for large bone defects has the limitation of harvesting co-morbidity and limited availability. This drives the orthopaedic research community to develop bone graft substitutes. Routinely, supra-physiological doses of bone morphogenetic proteins (BMPs) are applied perpetuating concerns over undesired side effects and cost of BMPs. We therefore aimed to design a composite scaffold that allows maintenance of protein bioactivity and enhances growth factor retention at the implantation site. Critical-sized defects in sheep tibiae were treated with the autograft and with two dosages of rhBMP-7, 3.5 mg and 1.75 mg, embedded in a slowly degradable medical grade poly(ε-caprolactone) (PCL) scaffold with β-tricalcium phosphate microparticles (mPCL-TCP). Specimens were characterised by biomechanical testing, microcomputed tomography and histology. Bridging was observed within 3 months for the autograft and both rhBMP-7 treatments. No significant difference was observed between the low and high rhBMP-7 dosages or between any of the rhBMP-7 groups and autograft implantation. Scaffolds alone did not induce comparable levels of bone formation compared to the autograft and rhBMP-7 groups. In summary, the mPCL-TCP scaffold with the lower rhBMP-7 dose led to equivalent results to autograft transplantation or the high BMP dosage. Our data suggest a promising clinical future for BMP application in scaffold-based bone tissue engineering, lowering and optimising the amount of required BMP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE. We develop a sheep thoracic spine interbody fusion model to study the suitability of polycaprolactone-based scaffold and recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute within the thoracic spine. The surgical approach is a mini- open thoracotomy with relevance to minimally invasive deformity correction surgery for adolescent idiopathic scoliosis. To date there are no studies examining the use of this biodegradable implant in combination with biologics in a sheep thoracic spine model. METHODS. In the present study, six sheep underwent a 3-level (T6/7, T8/9 and T10/11) discectomy with randomly allocated implantation of a different graft substitute at each of the three levels; (i) calcium phosphate (CaP) coated polycaprolactone-based scaffold plus 0.54μg rhBMP-2, (ii) CaP coated PCL- based scaffold alone or (iii) autograft (mulched rib head). Fusion was assessed at six months post-surgery. RESULTS. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL- based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluations of the respective groups. Biomechanical testing revealed significantly higher stiffness for the rhBMP-2 plus PCL- based scaffold group in all loading directions in comparison to the other two groups. CONCLUSION. The results of this study demonstrate that rhBMP-2 plus PCL- based scaffold is a viable bone graft substitute, providing an optimal environment for thoracic interbody spinal fusion in a large animal model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction Well-designed biodegradable scaffolds in combination with bone growth factors offer a valuable alternative to the current gold standard autograft in spinal fusion surgery Yong et al. (2013). Here we report on 6- vs 12- month data set evaluating the longitudinal performance of a CaP coated polycaprolactone (PCL) scaffold loaded with recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute within a large preclinical animal model. Methods Twelve sheep underwent a 3-level (T6/7, T8/9 and T10/11) discectomy with randomly allocated implantation of a different graft substitute at each of the three levels; (i) calcium phosphate (CaP) coated polycaprolactone based scaffold plus 0.54µg rhBMP-2, (ii) CaP coated PCL- based scaffold alone or (iii) autograft (mulched rib head). Fusion assessments were performed via high resolution clinical computed tomography and histological evaluation were undertaken at six (n=6) and twelve (n=6) months post-surgery using the Sucato grading system (Sucato et al. 2004). Results The computed tomography fusion grades of the 6- and 12- months in the rhBMP-2 plus PCL- based scaffold group were 1.9 and 2.1 respectively, in the autograft group 1.9 and 1.3 respectively, and in the scaffold alone group 0.9 and 1.17 respectively. There were no statistically significant differences in the fusion scores between 6- and 12- month for the rhBMP plus PCL- based scaffold or PCL – based scaffold alone group however there was a significant reduction in scores in the autograft group. These scores were seen to correlate with histological evaluations of the respective groups. Conclusions The results of this study demonstrate the efficacy of scaffold-based delivery of rhBMP-2 in promoting higher fusion grades at 6- and 12- months in comparison to the scaffold alone or autograft group within the same time frame. Fusion grades achieved at six months using PCL+rhBMP-2 are not significantly increased at twelve months post-surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is strong current interest in the use of biodegradable scaffolds in combination with bone growth factors as a valuable alternative to the current gold standard autograft in spinal fusion surgery Yong et al. (2013). Here we report on 6- vs 12- month data set evaluating the longitudinal performance of a CaP coated polycaprolactone (PCL) scaffold loaded with recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute within a preclinical ovine thoracic spine. The results of this study demonstrate the efficacy of scaffold-based delivery of rhBMP-2 in promoting higher fusion grades at 6- and 12- months in comparison to the scaffold alone or autograft group within the same time frame. Fusion grades achieved at six months using PCL+rhBMP-2 are not significantly increased at twelve months post surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Study Design This was a randomised controlled trial in patients with degenerative disc disease (DDD) who underwent instrumented posterolateral lumbar fusion (PLF) surgery. Objective The aim of this study was to assess the efficacy of the bone grafting substitute, silicate-substituted calcium phosphate (SiCaP) compared with bone morphogenetic protein (rhBMP-2) and to evaluate clinical outcomes over a period of two years. Methods Patients undergoing PLF surgery for DDD at a single centre were recruited and randomised to one of two groups; SiCaP (n=9) or rhBMP-2 (n=10). One patient withdrew prior to randomisation and another from the rhBMP-2 group after randomisation. The radiological and clinical outcomes were examined and compared. Fusion was assessed at 12 months with computed tomography (CT) and plain radiographs. Clinical outcomes were evaluated by recording measures of pain, quality of life, disability and neurological status from six weeks to two years postoperatively. Results In the SiCaP and rhBMP-2 groups, fusion was observed in 9/9 and 8/9 patients respectively. Pain and disability scores were reduced and quality of life increased in both groups. Leg pain, disability and satisfaction scores were similar between the groups at each postoperative time point, however, back pain was less at six weeks and quality of life was higher at six months in the SiCaP group than the rhBMP-2 group. Conclusions SiCaP and rhBMP-2 were comparable in terms of achieving successful bone growth and fusion. Both groups similarly alleviated pain and improved quality of life, neurological, satisfaction and return to work outcomes following PLF surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Os estudos abordando a regeneração dos tecidos dentários ganharam uma nova perspectiva com a utilização das células-tronco. E novas perspectivas têm surgido com a bioengenharia tecidual e as terapias periodontais e pulpares regeneradoras. O objetivo deste trabalho foi desenvolver o modelo experimental de autotransplante em ratos visando compará-lo à técnica de reimplante e estudar a capacidade terapêutica das células da medula óssea em diferentes biomateriais utilizados como matriz para a terapia de células-tronco no reparo dos tecidos dentais. Foram utilizados 23 ratos Wistar divididos em grupos de 1, 3, 15 e 60 dias para as técnicas de reimplante e autotransplante. Os grupos com injeção de células-tronco (CT) foram: (1) grupo de 3 dias, combinado à técnica de reimplante; (2) grupo de 15 dias com ambas as técnicas. Blocos contendo os três dentes molares superiores de cada lado dos ratos foram removidos, feitas radiografias periapicais e as peças foram processadas para inclusão em parafina. Foram avaliadas a espessura do ligamento periodontal (LPD) comparada entre os diferentes grupos e a morfologia celular e matriz extracelular relacionadas à superfície radicular, ao osso alveolar e à porção média do LPD, além das células da polpa dental de cada grupo. As células isoladas a partir da medula-óssea foram incubadas por 24h, 48h, e 72h em placas de cultura contendo membranas de colágeno bovino tipo I - CollaTape (Integra LifeSciences Corporation, Plainsboro, NJ, USA), enxerto ósseo - Extra Graft XG-13 (Silvestre Labs Quimica e Farmaceutica LTDA, RJ, Brazil) ou um dente molar de rato. Os espécimes foram observados em um microscópio invertido para contagem de células e processadas para observação no microscópio eletrônico de varredura (MEV). Os grupos de 1 e 3 dias apresentaram medidas de LPD significativamente maiores para a técnica de autotransplante quando comparadas ao reimplante. O grupo de 3 dias com CT não apresentou alterações pulpares significativas, diferente do controle (sem CT) O grupo de 15 dias com CT apresentou as mesmas características histológicas do grupo sem injeção de CT. A observação ao MEV dos biomateriais revelou que as células apresentaram pouca adesão e proliferação no enxerto ósseo e no cemento dentário quando comparados à membrana colágena. A técnica de reimplante associada à injeção de células-tronco sugere alguma influência da terapia com as células-tronco sobre a polpa. As distâncias aumentadas no LPD com a técnica de autotransplante podem não influenciar tanto o sucesso da técnica. As células mesenquimais da medula óssea possuem grande potencial para colonizarem a membrana colágena CollaTape que mostrou vantagens sobre o enxerto ósseo Extra Graft XG-13 como biomaterial para a aderência e a proliferação de células mononucleares da medula óssea, permitindo a diferenciação destas células.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Enxerto ósseo homólogo é utilizado independentemente da compatibilidade HLA entre doador e receptor ou uso de drogas imunossupressoras. Considerando o volume de transplantes ósseos realizados no Brasil e o possível efeito deletério da sensibilização HLA para o transplante de órgãos sólidos, este estudo tem como objetivo avaliar a alorreatividade do enxerto ósseo homólogo fresco-congelado utilizado na reconstrução alveolar com finalidade de reabilitação oral com prótese sobre implantes. Anticorpos anti-HLA e anti-MICA foram monitorados através do teste Labscreen Mixed, nos intervalos 0, 7, 30, 90 e 180 pós transplante ósseo em 15 pacientes (6 homens e 9 mulheres, idade média 58,1, DP=10,1) que estavam em tratamento no Instituto de Odontologia da Pontifícia Universidade Católica do Rio de Janeiro. Caso resultado do teste Mixed fosse positivo (Razão de fundo normatizado, NBG>4,5) o teste Labscreen Single (tecnologia antígeno único por pérola, SABA) era realizado para verificar se os anticorpos anti-HLA eram específicos ao doador. Nenhum paciente relatou transplante prévio, 4 relataram transfusão prévia e todas as mulheres relataram gravidez. Dez pacientes não apresentaram reação positiva no dia 0 sendo considerados não sensibilizados previamente (NSP); destes, 6 pacientes permaneceram sem nenhuma evidência de sensibilização, 2 pacientes apresentaram reação positiva para Classe I e II; 2 para Classe I apenas; e 2 para MICA, sendo considerados sensibilizados pelo enxerto ósseo oral. Dois pacientes apresentaram aumento de Intensidade Média de Fluorescência (ΔMFI>1000) de anticorpos específicos ao doador para Classe I e Classe II, e 2 somente para Classe II, demonstrando uma reação específica ao doador. Os resultados sugerem uma alorreatividade HLA oscilatória ao enxerto ósseo homólogo em reconstruções alveolares, confirmada pela formação de anticorpos anti-HLA específicos ao doador em 4 pacientes (27%) da amostra.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Enxertos ósseos homólogos congelados têm sido documentados apresentando bons resultados clínicos como substituto ao material autógeno nas reconstruções alveolares. Entretanto, dados referentes à incorporação e remodelação destes enxertos não estão disponíveis na literatura. Este estudo tem por objetivo determinar um período ótimo de espera para instalação de implantes em rebordos reconstruídos com enxertos ósseos homólogos em bloco no que se refere à incorporação e reabsorção. 24 pacientes foram submetidos à reconstrução alveolar óssea homóloga previamente à instalação de implantes. Os indivíduos foram alocados randomicamente em um de 3 grupos de acordo com o tempo de espera para o segundo estágio cirúrgico (4, 6 e 8 meses). Análises tomográficas, histológicas e histomorfométricas foram utilizadas a fim de determinar o grau de reabsorção e incorporação dos enxertos nos diferentes intervalos de tempo para cada grupo. Os dados de reabsorção sofrida pelos enxertos demonstraram diferenças estatisticamente significativas para os três intervalos de espera. Da mesma forma, parâmetros histomorfométricos como contagem de osteócitos e quantificação de remanescentes de osso homólogo nas biópsias apresentaram diferenças significativas entre os grupos. De acordo com os dados do presente trabalho, no que diz respeito à remodelação e incorporação, o período mais favorável à instalação dos implantes a curto prazo após recontruções com enxertos homólogos é de 4 meses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Monografia apresentada à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciada em Medicina Dentária