977 resultados para ORTHOPEDIC IMPLANTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In his forum paper, Prof. Kevin Warwick considers four different examples of how the use of implant technology is opening up the possibility of upgrading human abilities, particularly in terms of mental cognition. The main thrust is an overview of Prof. Warwick's own research, which led to him receiving a neural implant linking his nervous system bi-directionally with the internet. With this implant in place, neural signals were transmitted to various technological devices to directly control them, in some cases via the internet, and feedback to the brain was obtained from such stimuli as the fingertips of a robot hand, ultrasonic (extra-) sensory input and neural signals directly from another human's nervous system. A view is taken as to the prospects for the future, both in the short-term as a therapeutic device and in the long-term as a form of enhancement, including the realistic potential, in the near future, for thought communication – thereby opening up tremendous commercial potential. The therapy/enhancement dichotomy is considered here, as well as military and medical issues. Clearly though, an individual whose brain is part human/part machine can have abilities that far surpass those who remain with a human brain alone. Will such an individual exhibit different moral and ethical values to those of a human? If so, what effects might this have on society?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power delivery for biomedical implants is a major consideration in their design for both measurement and stimulation. When performed by a wireless technique, transmission efficiency is critically important not only because of the costs associated with any losses but also because of the nature of those losses, for example, excessive heat can be uncomfortable for the individual involved. In this study, a method and means of wireless power transmission suitable for biomedical implants are both discussed and experimentally evaluated. The procedure initiated is comparable in size and simplicity to those methods already employed; however, some of Tesla’s fundamental ideas have been incorporated in order to obtain a significant improvement in efficiency. This study contains a theoretical basis for the approach taken; however, the emphasis here is on practical experimental analysis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human ICT implants, such as RFID implants, cochlear implants, cardiac pacemakers, Deep Brain Stimulation, bionic limbs connected to the nervous system, and networked cognitive prostheses, are becoming increasingly complex. With ever-growing data processing functionalities in these implants, privacy and security become vital concerns. Electronic attacks on human ICT implants can cause significant harm, both to implant subjects and to their environment. This paper explores the vulnerabilities which human implants pose to crime victimisation in light of recent technological developments, and analyses how the law can deal with emerging challenges of what may well become the next generation of cybercrime: attacks targeted at technology implanted in the human body. After a state-of-the-art description of relevant types of human implants and a discussion how these implants challenge existing perceptions of the human body, we describe how various modes of attacks, such as sniffing, hacking, data interference, and denial of service, can be committed against implants. Subsequently, we analyse how these attacks can be assessed under current substantive and procedural criminal law, drawing on examples from UK and Dutch law. The possibilities and limitations of cybercrime provisions (eg, unlawful access, system interference) and bodily integrity provisions (eg, battery, assault, causing bodily harm) to deal with human-implant attacks are analysed. Based on this assessment, the paper concludes that attacks on human implants are not only a new generation in the evolution of cybercrime, but also raise fundamental questions on how criminal law conceives of attacks. Traditional distinctions between physical and non-physical modes of attack, between human bodies and things, between exterior and interior of the body need to be re-interpreted in light of developments in human implants. As the human body and technology become increasingly intertwined, cybercrime legislation and body-integrity crime legislation will also become intertwined, posing a new puzzle that legislators and practitioners will sooner or later have to solve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power delivery for biomedical implants is a major consideration in their design for both measurement and stimulation. When performed by a wireless technique, transmission efficiency is critically important not only because of the costs associated with any losses but also because of the nature of those losses, for example, excessive heat can be uncomfortable for the individual involved. In this study, a method and means of wireless power transmission suitable for biomedical implants are both discussed and experimentally evaluated. The procedure initiated is comparable in size and simplicity to those methods already employed; however, some of Tesla’s fundamental ideas have been incorporated in order to obtain a significant improvement in efficiency. This study contains a theoretical basis for the approach taken; however, the emphasis here is on practical experimental analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subdermal magnetic implants originated as an art form in the world of body modification. To date an in depth scientific analysis of the benefits of this implant has yet to be established. This research explores the concept of sensory extension of the tactile sense utilising this form of implantation. This relatively simple procedure enables the tactile sense to respond to static and alternating magnetic fields. This is not to say that the underlying biology of the system has changed; i.e. the concept does not increase our tactile frequency response range or sensitivity to pressure, but now does invoke a perceptual response to a stimulus that is not innately available to humans. Within this research two social surveys have been conducted in order to ascertain one, the social acceptance of the general notion of human enhancement, and two the perceptual experiences of individuals with the magnetic implants themselves. In terms of acceptance to the notion of sensory improvement (via implantation) ~39% of the general population questioned responded positively with a further ~25% of the respondents answering with the indecisive response. Thus with careful dissemination a large proportion of individuals may adopt this technology much like this if it were to become available for consumers. Interestingly of the responses collected from the magnetic implants survey ~60% of the respondents actually underwent the implant for magnetic vision purposes. The main contribution of this research however comes from a series of psychophysical testing. In which 7 subjects with subdermal magnetic implants, were cross compared with 7 subjects that had similar magnets superficially attached to their dermis. The experimentation examined multiple psychometric thresholds of the candidates including intensity, frequency and temporal. Whilst relatively simple, the experimental setup for the perceptual experimentation conducted was novel in that custom hardware and protocols were created in order to determine the subjective thresholds of the individuals. Abstract iv The overall purpose of this research is to utilise this concept in high stress scenarios, such as driving or piloting; whereby alerts and warnings could be relayed to an operator without intruding upon their other (typically overloaded) exterior senses (i.e. the auditory and visual senses). Hence each of the thresholding experiments were designed with the intention of utilising the results in the design of signals for information transfer. The findings from the study show that the implanted group of subjects significantly outperformed the superficial group in the absolute intensity threshold experiment, i.e. the implanted group required significantly less force than the superficial group in order to perceive the stimulus. The results for the frequency difference threshold showed no significant difference in the two groups tested. Interestingly however at low frequencies, i.e. 20 and 50 Hz, the ability of the subjects tested to discriminate frequencies significantly increased with more complex waveforms i.e. square and sawtooth, when compared against the typically used sinewave. Furthermore a novel protocol for establishing the temporal gap detection threshold during a temporal numerosity study has been established in this thesis. This experiment measured the subjects’ capability to correctly determine the number of concatenated signals presented to them whilst the time between the signals, referred to as pulses, tended to zero. A significant finding was that when altering the length of, the frequency of, and the number of cycles of the pulses, the time between pulses for correct recognition altered. This finding will ultimately aid in the design of the tactile alerts for this method of information transfer. Preliminary development work for the use of this method of input to the body, in an automotive scenario, is also presented within this thesis in the form of a driving simulation. The overall goal of which is to present warning alerts to a driver, such as rear-to-end collision, or excessive speeds on roads, in order to prevent incidents and penalties from occurring. Discussion on the broader utility of this implant has been presented, reflecting on its potential use as a basis for vibrotactile, and sensory substitution, devices. This discussion furthers with postulations on its use as a human machine interface, as well as how a similar implant could be used within the ear as a hearing aid device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postural control was evaluated in cochlear implant participants with and without amplification under several auditory paradigms. Speed of sway was recorded in each condition by means of Computerized Dynamic Posturography. Results indicate that an external sound source significantly improves balance in patients with cochlear implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spontaneous writing samples of deaf children with cochlear implants were analyzed for auxiliary verb errors. These results were compared to norms of typically developing children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the checkerboard DNA-DNA hybridization method for detection and quantitation of bacteria from the internal parts of dental implants and to compare bacterial leakage from implants connected either to cast or to pre-machined abutments. Nine plastic abutments cast in a Ni-Cr alloy and nine pre-machined Co-Cr alloy abutments with plastic sleeves cast in Ni-Cr were connected to Branemark-compatible implants. A group of nine implants was used as control. The implants were inoculated with 3 mu l of a solution containing 10(8) cells/ml of Streptococcus sobrinus. Bacterial samples were immediately collected from the control implants while assemblies were completely immersed in 5 ml of sterile Tripty Soy Broth (TSB) medium. After 14 days of anaerobic incubation, occurrence of leakage at the implant-abutment interface was evaluated by assessing contamination of the TSB medium. Internal contamination of the implants was evaluated with the checkerboard DNA-DNA hybridization method. DNA-DNA hybridization was sensitive enough to detect and quantify the microorganism from the internal parts of the implants. No differences in leakage and in internal contamination were found between cast and pre-machined abutments. Bacterial scores in the control group were significantly higher than in the other groups (P < 0.05). Bacterial leakage through the implant-abutment interface does not significantly differ when cast or pre-machined abutments are used. The checkerboard DNA-DNA hybridization technique is suitable for the evaluation of the internal contamination of dental implants although further studies are necessary to validate the use of computational methods for the improvement of the test accuracy. To cite this article:do Nascimento C, Barbosa RES, Issa JPM, Watanabe E, Ito IY, Albuquerque Junior RF. Use of checkerboard DNA-DNA hybridization to evaluate the internal contamination of dental implants and comparison of bacterial leakage with cast or pre-machined abutments.Clin. Oral Impl. Res. 20, 2009; 571-577.doi: 10.1111/j.1600-0501.2008.01663.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments. Int J Prosthodont 2009;22:283-286.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate, through fluorescence analysis, the effect that different interimplant distances, after prosthetic restoration, will have on bone remodeling in submerged and nonsubmerged implants restored with a ""platform switch."" Materials and Methods: Fifty-six Ankylos implants were placed 1.5 mm subcrestally in seven dogs. The implants were placed so that two fixed prostheses, with three interimplant contacts separated by 1-mm, 2-mm, and 3-mm distances, could be fabricated for each side of the mandible. The sides and the positions of the groups were selected randomly. To better evaluate bone remodeling, calcein green was injected 3 days before placement of the prostheses at 12 weeks postimplantation. At 3 days before sacrifice (8 weeks postloading), alizarin red was injected. The amounts of remodeled bone within the different interimplant areas were compared statistically before and after loading in submerged and nonsubmerged implants. Results: Statistically significant differences existed in the percentage of remodeled bone seen in the different regions. Mean percentages of remodeled bone in the submerged and nonsubmerged groups, respectively, were as follows: for the 1-mm distance, 23.0% +/- 0.05% and 23.1% +/- 0.03% preloading and 27.0% +/- 0.03% and 25.2% +/- 0.04% postloading, for the 2-mm distance, 18.2% +/- 0.05% and 18.1% +/- 0.04% preloading and 21.3% +/- 0.07% and 19.9% +/- 0.03% postloading, for the 3-mm distance, 18.3% +/- 0.03% and 18.3% +/- 0.03% preloading and 18.8% +/- 0.04% and 19.8% +/- 0.04% postloading, for distal-extension regions, 16.6% +/- 0.02% and 17.4% +/- 0.04% preloading and 17.0% +/- 0.04% and 18.4% +/- 0.04% postloading. Conclusions: Based upon this animal study, loading increases bone formation for submerged or nonsubmerged implants, and the interimplant distance of 1 mm appears to result in more pronounced bone remodeling than the 2-mm or 3-mm distances in implants with a ""platform switch."" INT J ORAL MAXILLOFAC IMPLANTS 2009;24:257-266

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hopeless retained primary teeth without permanent successors represent a restorative challenge for clinicians, along with esthetic and functional problems for patients. While various treatment approaches for congenitally missing teeth have been proposed, the replacement of a missing tooth with a dental implant offers specific advantages, such as preservation of the alveolar crest and elimination of the need to restore the adjacent teeth, over other options for tooth replacement. The aim of this article was to illustrate the surgical and prosthetic treatment with implants of a patient with primary teeth without permanent successors. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:151-154