402 resultados para MALEATED POLYPROPYLENE
Resumo:
An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.
Resumo:
Verandah trap huts in Tanzania village were used to assess the effectiveness if impregnated bednets and curtains in preventing hut entry and feeding by, and in killing of, Anopheles gambiae and An. funestus. Permethrin, deltamethrin, lambdacyhalothrin and pyrethrum were used for impregnation of damaged or undamaged bednets, sisal eaves curtains or bed curtains made of polypropylene fibre. The performance of the synthetic pyrethroids did not differ statistically significantly, except that on a damage net permethrin was better at preventing feeding. sisal eaves curtains deterred mosquitoes from hut entry but did not kill those that had entered. In assessing damaged nets and curtains it must be recognised that anything less than the best vector control may have no appreciable impact on holoendemic malaria.
Resumo:
The present study was undertaken to examine the cross-sectional vascular compliance at the anastomotic site. METHODS AND MATERIAL: We performed end-to-end anastomosis on the carotid artery of six pigs using continuous 6/0 polypropylene. Four carotid arteries were excised and mounted in a perfusion chamber while the remaining two were left in living animals. We used pulsed ultrasound (NIUS 02) to generate detailed longitudinal profiles of diameter and compliance in the proximity and on the anastomosis. RESULTS: On the anastomosis, the vessel diameter decreases (-1 to -2.6% of diastolic diameter) when blood pressure increases with an exponential correlation (R2 = 0.75). The arterial compliance at the anastomosis was negative: the vessel cross-section reduction for a pulse pressure of 1 up to 32 mmHg was 0.9 to 2% of diastolic vessel cross-section. CONCLUSIONS: Vessel movement generated a dynamic stenosis whose magnitude seems to depend on blood pressure level. Increasing blood pressure causes the retraction of vessel ends which causes vessel lumen reduction. These results suggest that continuous suture does not provide the continuity of mechanical properties of the artery.
Resumo:
A new and original reagent based on the use of highly fluorescent cadmium telluride (CdTe) quantum dots (QDs) in aqueous solution is proposed to detect weak fingermarks in blood on non-porous surfaces. To assess the efficiency of this approach, comparisons were performed with one of the most efficient blood reagents on non-porous surfaces, Acid Yellow 7 (AY7). To this end, four non-porous surfaces were studied, i.e. glass, transparent polypropylene, black polyethylene, and aluminium foil. To evaluate the sensitivity of both reagents, sets of depleted fingermarks were prepared, using the same finger, initially soaked with blood, which was then successively applied on the same surface without recharging it with blood or latent secretions. The successive marks were then cut in halves and the halves treated separately with each reagent. The results showed that QDs were equally efficient to AY7 on glass, polyethylene and polypropylene surfaces, and were superior to AY7 on aluminium. The use of QDs in new, sensitive and highly efficient latent and blood mark detection techniques appears highly promising. Health and safety issues related to the use of cadmium are also discussed. It is suggested that applying QDs in aqueous solution (and not as a dry dusting powder) considerably lowers the toxicity risks.
Resumo:
L’empresa Proslit Equipment forma part del Grup Comexi i la seva activitat consisteix en la fabricació de màquines talladores de material flexible. Degut als avenços tecnològics, s’han incrementat les prestacions de les seves màquines, entre altres coses, s’ha augmentat la velocitat de tall del film fins a 800 m/min. Aquest factor afegit a condicionants com per exemple treballar amb materials gruixuts i abrasius, a temperatures ambientals elevades, etc. fa que sorgeixi una problemàtica en el tall gillette. Degut a la fricció entre el film que circula i les gillettes que el tallen, es crea una energia calorífica que fa augmentar la temperatura de les gillettes fins a tal extrem que aquestes provoquen petites fusions del plàstic, aquest s’incrusta a les gillettes que s’acaben trencant. L’objecte principal d’aquest projecte és fer una anàlisi tècnica mitjançant elements finits de la problemàtica que s’ha detectat a les màquines talladores de l’empresa Proslit Equipment, concretament de l’escalfament de les gillettes utilitzades en el sistema de tall. Es pretén crear un model teòric que s’aproximi al màxim a la realitat de manera que es pugui observar el comportament tèrmic del sistema de tall en funció de les condicions que es determinin com a més desfavorables. Una vegada s’obtinguin aquests resultats teòrics, es valoraran i es proposaran solucions
Resumo:
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.
Resumo:
Aquest projecte de doctorat és un treball interdisciplinari adreçat a l’obtenció de nous nanocompòsits (NCs) funcionals sintetitzats a partir de materials polimèrics bescanviadors d’ions que són modificats amb nanopartícules metàl•liques (NPMs) de diferent composició. Els materials desenvolupats s’avaluen en funció de dues possibles aplicacions: 1) com a catalitzadors de reaccions orgàniques d’interès actual (NCs basats en pal•ladi) i, 2) la seva dedicació a aplicacions bactericides en el tractament d’aigües domèstiques o industrials (NCs basats en plata). El desenvolupament de nanomaterials és de gran interès a l’actualitat donades les seves especials propietats, l’aprofitament de les quals és la força impulsora per a la fabricació de nous NCs. Les nanopartícules metàl•liques estabilitzades en polímer (Polymer Stabilized Metal Nanoparticles, PSNPM) s’han preparat mitjançant la tècnica in-situ de síntesi intermatricial (Inter-matrix synthesis, IMS) que consisteix en la càrrega seqüencial dels grups funcionals de les matrius polimèriques amb ions metàl•lics, i la seva posterior reducció química dins de la matriu polimèrica de bescanvi iònic. L’estabilització en matrius polimèriques evita l’agregació entre elles (self-aggreagtion), un dels principals problemes coneguts de les NPs. Pel desenvolupament d’aquesta metodologia, s’han emprat diferents tipus de matrius polimèriques de bescanvi iònic: membrana Sulfonated PolyEtherEtherKetone, SPEEK, així com fibres sintètiques basades en polypropilè amb diferents tipus de grups funcionals, que ens permeten el seu ús com a filtres en la desinfecció de solucions aquoses o com a material catalitzador. Durant el projecte s’ha anat avançant en l’optimització del material nanocomposite final per a les aplicacions d’interès, en quant activitat i funcionalitat de les nanopartícules i estabilitat del nanocomposite. Així, s’ha optimitzat la síntesi de NPs estabilitzades en resines de bescanvi iònic, realitzant un screening de diferents tipus de resines i la seva avaluació en aplicacions industrials d’interès.
Resumo:
Stone groundwood (SGW) is a fibrous matter commonly prepared in a high yield process, and mainly used for papermaking applications. In this work, the use of SGW fibers is explored as reinforcing element of polypropylene (PP) composites. Due to its chemical and superficial features, the use of coupling agents is needed for a good adhesion and stress transfer across the fiber-matrix interface. The intrinsic strength of the reinforcement is a key parameter to predict the mechanical properties of the composite and to perform an interface analysis. The main objective of the present work was the determination of the intrinsic tensile strength of stone groundwood fibers. Coupled and non-coupled PP composites from stone groundwood fibers were prepared. The influence of the surface morphology and the quality at interface on the final properties of the composite was analyzed and compared to that of fiberglass PP composites. The intrinsic tensile properties of stone groundwood fibers, as well as the fiber orientation factor and the interfacial shear strength of the current composites were determined
Resumo:
A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.
Resumo:
· Evaluate conventional methods of slab removal and asphalt surface preparation for subsequent overlays of portland cement concrete (PCC) in the “remove and replace” areas. · Evaluate existing asphaltic concrete surface under the “remove and patch” areas of rehabilitation areas and evaluate joint formation in the areas of patching. · Evaluate polypropylene fiber enhanced concrete at the three-inch depth to determine the cost/benefit of its inclusion. · Evaluate the performance of the rehabilitated ultra-thin whitetopping sections and the extended performance of the existing ultra-thin sections with and without patching. · Validate existing ultra-thin whitetopping design procedures of the Portland Cement Association (PCA) and American Concrete Pavement Association (ACPA) for application in Iowa.
Resumo:
RATIONALE The choice of containers for storage of aqueous samples between their collection, transport and water hydrogen (2H) and oxygen (18O) stable isotope analysis is a topic of concern for a wide range of fields in environmental, geological, biomedical, food, and forensic sciences. The transport and separation of water molecules during water vapor or liquid uptake by sorption or solution and the diffusive transport of water molecules through organic polymer material by permeation or pervaporation may entail an isotopic fractionation. An experiment was conducted to evaluate the extent of such fractionation. METHODS Sixteen bottle-like containers of eleven different organic polymers, including low and high density polyethylene (LDPE and HDPE), polypropylene (PP), polycarbonate (PC), polyethylene terephthalate (PET), and perfluoroalkoxy-Teflon (PFA), of different wall thickness and size were completely filled with the same mineral water and stored for 659?days under the same conditions of temperature and humidity. Particular care was exercised to keep the bottles tightly closed and prevent loss of water vapor through the seals. RESULTS Changes of up to +5 parts per thousand for d2H values and +2.0 parts per thousand for d18O values were measured for water after more than 1?year of storage within a plastic container, with the magnitude of change depending mainly on the type of organic polymer, wall thickness, and container size. The most important variations were measured for the PET and PC bottles. Waters stored in glass bottles with Polyseal (TM) cone-lined PP screw caps and thick-walled HDPE or PFA containers with linerless screw caps having an integrally molded inner sealing ring preserved their original d2H and d18O values. The carbon, hydrogen, and oxygen stable isotope compositions of the organic polymeric materials were also determined. CONCLUSIONS The results of this study clearly show that for precise and accurate measurements of the water stable isotope composition in aqueous solutions, rigorous sampling and storage procedures are needed both for laboratory standards and for unknown samples. Copyright (c) 2012 John Wiley & Sons, Ltd.
Resumo:
The use of quantum dots (QDs) in the area of fingermark detection is currently receiving a lot of attention in the forensic literature. Most of the research efforts have been devoted to cadmium telluride (CdTe) quantum dots often applied as powders to the surfaces of interests. Both the use of cadmium and the nano size of these particles raise important issues in terms of health and safety. This paper proposes to replace CdTe QDs by zinc sulphide QDs doped with copper (ZnS:Cu) to address these issues. Zinc sulphide-copper doped QDs were successfully synthesized, characterized in terms of size and optical properties and optimized to be applied for the detection of impressions left in blood, where CdTe QDs proved to be efficient. Effectiveness of detection was assessed in comparison with CdTe QDs and Acid Yellow 7 (AY7, an effective blood reagent), using two series of depletive blood fingermarks from four donors prepared on four non-porous substrates, i.e. glass, transparent polypropylene, black polyethylene and aluminium foil. The marks were cut in half and processed separately with both reagents, leading to two comparison series (ZnS:Cu vs. CdTe, and ZnS:Cu vs. AY7). ZnS:Cu proved to be better than AY7 and at least as efficient as CdTe on most substrates. Consequently, copper-doped ZnS QDs constitute a valid substitute for cadmium-based QDs to detect blood marks on non-porous substrates and offer a safer alternative for routine use.
Resumo:
The objective of this work was to set up ideal conditions for conidia mass production of Dicyma pulvinata. Four isolates were compared in terms of their growth and conidia production on various substrates (grains of parboiled rice, common rice, maize and wheat, besides chipped maize and rice husk), temperatures (19, 22, 25, 28 and 31ºC), growth containers (aluminum trays, polypropylene bags and Erlenmeyers) and light regimes (continuous darkness, 6 and 12 hours of light/darkness, and continuous light). Temperature effects on conidia germination capacity were also evaluated. The experiments were done in randomized complete block designs, in factorial arrangements (isolates x treatments - substrates, containers, temperatures and light regimes), with four replicates. In general, parboiled rice and polypropylene bags provided the best development of the fungus. Complete darkness and 6 hours of light increased mycelial growth, whereas continuous light favored sporulation. All tested temperatures favored the cultures of the fungus, except 31ºC. Temperatures between 19 and 25ºC ensure spore germination of more than 76%.
Resumo:
The objective of this work was to analyze changes in the isoflavone profile, determined by high performance liquid chromatography, at different processing stages and after refrigeration of tempeh. For tempeh production, clean soybean grains from cultivars BR 36 (low isoflavone content) and IAS 5 (high) were dehulled, and the separated cotyledons were hydrated and then cooked in boiling water for 30 min. Spores of the fungus Rhizopus microsporus var. oligosporus were inoculated in the cooked and cooled cotyledons, and incubated at 32ºC for 6, 12, 18, and 24 hours in perforated polypropylene bags, for fermentation. The resulting tempeh was stored at 4ºC for 6, 12, 18, and 24 hours. After 24-hour fermentation, isoflavone glucosides were 50% reduced, and the aglycone forms in the tempeh from both cultivars was increased. The malonyl forms reduced 83% after cooking. Less than 24 hours of refrigeration did not affect the isoflavone profile of tempeh from either cultivar, which is a good indicator of its quality. The tempeh maintains the high and low isoflavone content of the cultivars, which indicates that cultivar differences in this trait should be considered when processing tempeh.
Resumo:
IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.