975 resultados para LU-LC Conjecture
Resumo:
Résumé de: Glynn RJ et al. Rosuvastatin for primary prevention in older persons with elevated C-reactive protein and low to average low-density lipoprotein cholesterol levels: exploratory analysis of a randomized trial. Ann Intern Med. 2010 Apr 20;152(8):488-96, PMID: 20404379.
Resumo:
Collection : Archives de la linguistique française ; 79
Resumo:
The present study arose from the need to determine inorganic arsenic (iAs) at low levels in cereal-based food. Validated methods with a low limit of detection (LOD) are required to analyse these kinds of food. An analytical method for the determination of iAs, methylarsonic acid (MA) and dimethylarsinic acid (DMA) in cereal-based food and infant cereals is reported. The method was optimised and validated to achieve low LODs. Ion chromatography-inductively coupled plasma mass spectrometry (LC-ICPMS) was used for arsenic speciation. The main quality parameters were established. To expand the applicability of the method, different cereal products were analysed: bread, biscuits, breakfast cereals, wheat flour, corn snacks, pasta and infant cereals. The total and inorganic arsenic content of 29 cereal-based food samples ranged between 3.7-35.6 and 3.1-26.0 microg As kg-1, respectively. The present method could be considered a valuable tool for assessing inorganic arsenic contents in cereal-based foods.
Resumo:
BACKGROUND: Niemann-Pick type C (NP-C) is a rare progressive neurodegenerative lipid storage disorder with heterogeneous clinical presentation and challenging diagnostic procedures. Recently oxysterols have been reported to be specific biomarkers for NP-C but knowledge on the intra-individual variation and on reference intervals in children and adolescents are lacking. METHODS: We established a LC-MS/MS assay to measure Cholestane-3β, 5α, 6β-triol (C-triol) and 7-Ketocholesterol (7-KC) following Steglich esterification. To assess reference intervals and intra-individual variation we determined oxysterols in 148 children and adolescents from 0 to 18 years and repeat measurements in 19 of them. RESULTS: The reported method is linear (r>0.99), sensitive (detection limit of 0.03 ng/mL [0.07 nM] for C-triol, and 0.54 ng/mL [1.35 nM] for 7-KC) and precise, with an intra-day imprecision of 4.8% and 4.1%, and an inter-day imprecision of 7.0% and 11.0% for C-triol (28 ng/ml, 67 nM) and 7-KC (32 ng/ml, 80 nM), respectively. Recoveries for 7-KC and C-triol range between 93% and 107%. The upper reference limit obtained for C-triol is 40.4 ng/mL (95% CI: 26.4-61.7 ng/mL, 96.0 nM, 95% CI: 62.8-146.7 nM) and 75.0 ng/mL for 7-KC (95% CI: 55.5-102.5 ng/mL, 187.2 nM, 95% CI: 138.53-255.8 nM), with no age or gender dependency. Both oxysterols have a broad intra-individual variation of 46%±23% for C-triol and 52%±29% for 7-KC. Nevertheless, all Niemann-Pick patients showed increased C-triol levels including Niemann-Pick type A and B patients. CONCLUSIONS: The LC-MS/MS assay is a robust assay to quantify C-triol and 7-KC in plasma with well documented reference intervals in children and adolescents to screen for NP-C in the pediatric population. In addition our results suggest that especially the C-triol is a biomarker for all three Niemann-Pick diseases.
Resumo:
Viime vuosien nopea kehitys on kiihdyttänyt uusien lääkkeiden kehittämisprosessia. Kombinatorinen kemia on tehnyt mahdolliseksi syntetisoida suuria kokoelmia rakenteeltaan toisistaan poikkeavia molekyylejä, nk. kombinatorisia kirjastoja, biologista seulontaa varten. Siinä molekyylien rakenteeseen liittyvä aktiivisuus tutkitaan useilla erilaisilla biologisilla testeillä mahdollisten "osumien" löytämiseksi, joista osasta saatetaan myöhemmin kehittää uusia lääkeaineita. Jotta biologisten tutkimusten tulokset olisivat luotettavia, on syntetisoitujen komponenttien oltava mahdollisimman puhtaita. Tämän vuoksi tarvitaan HTP-puhdistusta korkealaatuisten komponenttien ja luotettavan biologisen tiedon takaamiseksi. Jatkuvasti kasvavat tuotantovaatimukset ovat johtaneet näiden puhdistustekniikoiden automatisointiin ja rinnakkaistamiseen. Preparatiivinen LC/MS soveltuu kombinatoristen kirjastojen nopeaan ja tehokkaaseen puhdistamiseen. Monet tekijät, esimerkiksi erotuskolonnin ominaisuudet sekä virtausgradientti, vaikuttavat preparatiivisen LC/MS puhdistusprosessin tehokkuuteen. Nämä parametrit on optimoitava parhaan tuloksen saamiseksi. Tässä työssä tutkittiin emäksisiä komponentteja erilaisissa virtausolosuhteissa. Menetelmä kombinatoristen kirjastojen puhtaustason määrittämiseksi LC/MS-puhdistuksen jälkeen optimoitiin ja määritettiin puhtaus joillekin komponenteille eri kirjastoista ennen puhdistusta.
Resumo:
In this work methods for the multiresidue determination of the series of quinolones include in the European regulation in food of animal origin are de veloped and validated in line with Commission Decision 2002/657/EC in terms of linearity, decision limit, capability detection, precision and stability. Mult iresidue methods were established to allow the determination of quinolones covered by EU legislation in 2377/90/EC in muscle of chicken, turkey, pig and cow, plasma of cow and pig, liver of pig and milk of cow. First an extraction step was optimized and a SPE step was applied to clean!up and preconcentrate quinolones prior to their separation by CE or LC and determination by CE!UV, LC!UV, LC!Fl, LC!MS with different ion sources (ESI ,ApCI) and different mass analyser (Q, ToF) and LC!E SI!QqQ tandem mass spectrometry. The limits of quantification obtained are always lower than Maxim um Residue Limit (MRL) established by EU for quinolones in animal products and they can be applied to the control of quinolones in foodstuffs of animal origin . Finally the proposed methods were applied to determine quinolones in samples of turkey and pig muscle, pig plasma and milk of cow. Excellent quality parameters and reduced time of analysis were obtained when LC!ESI!MS/MS is used, although the others techniques presented too satisfactory results.
Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.
Resumo:
High-resolution mass spectrometry (HRMS) has been associated with qualitative and research analysis and QQQ-MS with quantitative and routine analysis. This view is now challenged and for this reason, we have evaluated the quantitative LC-MS performance of a new high-resolution mass spectrometer (HRMS), a Q-orbitrap-MS, and compared the results obtained with a recent triple-quadrupole MS (QQQ-MS). High-resolution full-scan (HR-FS) and MS/MS acquisitions have been tested with real plasma extracts or pure standards. Limits of detection, dynamic range, mass accuracy and false positive or false negative detections have been determined or investigated with protease inhibitors, tyrosine kinase inhibitors, steroids and metanephrines. Our quantitative results show that today's available HRMS are reliable and sensitive quantitative instruments and comparable to QQQ-MS quantitative performance. Taking into account their versatility, user-friendliness and robustness, we believe that HRMS should be seen more and more as key instruments in quantitative LC-MS analyses. In this scenario, most targeted LC-HRMS analyses should be performed by HR-FS recording virtually "all" ions. In addition to absolute quantifications, HR-FS will allow the relative quantifications of hundreds of metabolites in plasma revealing individual's metabolome and exposome. This phenotyping of known metabolites should promote HRMS in clinical environment. A few other LC-HRMS analyses should be performed in single-ion-monitoring or MS/MS mode when increased sensitivity and/or detection selectivity will be necessary.
Resumo:
Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns (“intra capacitance”) of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be iron or even air as in the filter considered in this work. One of the foils, called the main foil, can be placed between the inverter and the motor cable. Other ones, called auxiliary foils, may be connected in star to create differential-mode noise paths, and then coupled to the DC link midpoint to guarantee a traveling path, especially for the common-mode currents. This way, there is a remarkable capacitance between the main foil and the auxiliary foil. Investigations showed that such a system can be described by a simple equivalent LC filter in a wide range of frequencies. Because of its simple hybrid construction, the proposed LC filter can be a cost-effective and competitive solution for modern power drives. In the thesis, the application field of the proposed filter is considered and determined. The basics of hybrid LC filter design are developed further. High-frequency behaviour of the proposed filter is analysed by simulations. Finally, the thesis presents experimental data proving that the hybrid LC filter can be used for du/dt of PWM pulses and reduction of common-mode currents.
Resumo:
A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.
Resumo:
A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.
Resumo:
A sensitive RP-HPLC method with UV detection successfully measured phenol(s) in an ointment containing 3% Stryphnodendron adstringens extract. Chromatography used acetonitrile (0.05% trifluoroacetic acid):water (0.05% trifluoroacetic acid) (v/v), flow rate 0.8 mL min-1. Quantitation was accomplished by the external-standard method. Linearity for 2.00 to 16.00 μg mL-1 (gallic acid) and 1.14 to 18.24 μg mL-1 (gallocatechin) was established. Intra- and inter-day precision levels were under 5%. LOD and LOQ were 0.231 and 0.770 μg mL-1 (gallic acid) and 0.151 and 0.504 μg mL-1 (gallocatechin), respectively. Determination of phenols was unaffected by product excipients.
Resumo:
Monitoring of sewage sludge has proved the presence of many polar anthropogenic pollutants since LC/MS techniques came into routine use. While advanced techniques may improve characterizations, flawed sample processing procedures, however, may disturb or disguise the presence and fate of many target compounds present in this type of complex matrix before analytical process starts. Freeze-drying or oven-drying, in combination with centrifugation or filtration as sample processing techniques were performed followed by visual pattern recognition of target compounds for assessment of pretreatment processes. The results shown that oven-drying affected the sludge characterization, while freeze-drying led to less analytical misinterpretations.