958 resultados para Isometric Contraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose. Activity of the trunk muscles is essential for maintaining stability of the lumbar spine because of the unstable structure of that portion of the spine. A model involving evaluation of the response of the lumbar multifidus and abdominal muscles to leg movement was developed to evaluate this function. Subjects. To examine this function in healthy persons, 9 male and 6 female subjects (mean age = 20.6 years, SD = 2.3) with no history of low back pain were studied. Methods. Fine-wire and surface electromyography electrodes were used to record the activity of selected trunk muscles and the prime movers for hip flexion, abduction, and extension during hip movements in each of these directions. Results. Trunk muscle activity occurring prior to activity of the prime mover of the limb was associated with hip movement in each direction. The transversus abdominis (TrA) muscle was invariably the first muscle that was active. Although reaction time for the TrA and oblique abdominal muscles was consistent across movement directions, reaction time for the rectus abdominis and multifidus muscles varied with the direction of limb movement. Conclusion and Discussion. Results suggest that the central nervous st stem deals with stabilization of the spine by contraction of the abdominal and multifidus muscles in anticipation of reactive forces produced by limb movement. The TrA and oblique abdominal muscles appear to contribute to a function not related to the direction of these forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibroblasts are thought to be partially responsible for the persisting contractile forces that result in burn contractures. Using a monolayer cell culture and fibroblast populated collagen lattice (FPCL) three-dimensional model we subjected hypertrophic scar and non-cicatricial fibroblasts to the antifibrogenic agent pentoxifylline (PTF - 1 mg/mL) in order to reduce proliferation, collagen types I and III synthesis and model contraction. Fibroblasts were isolated from post-burn hypertrophic scars (HSHF) and non-scarred skin (NHF). Cells were grown in monolayers or incorporated into FPCL`s and exposed to PTF. In monolayer, cell number proliferation was reduced (46.35% in HSHF group and 37.73% in NHF group, p < 0.0001). PTF selectively inhibited collagen III synthesis in the HSHF group while inhibition was more evident to type I collagen synthesis in the NHF group. PTF also reduced contraction in both (HSHF and NHF) FPCL. (C) 2009 Elsevier Ltd and ISBI. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because the structure of the spine is inherently unstable, muscle activation is essential for the maintenance of trunk posture and intervertebral control when the limbs are moved. To investigate how the central nervous system deals with this situation the temporal components of the response of the muscles of the trunk were evaluated during rapid limb movement performed in response to a visual stimulus. Fine-wire electromyography (EMG) electrodes were inserted into transversus abdominis (TrA), obliquus internus abdominis (OI) and obliquus externus abdominis (OE) of 15 subjects under the guidance of real-time ultrasound imaging. Surface electrodes were placed over rectus abdominis (RA), lumbar multifidus (MF) and the three parts of deltoid. In a standing position, ten repetitions of shoulder flexion, abduction and extension were performed by the subjects as fast as possible in response to a visual stimulus. The onset of TrA EMG occurred in advance of deltoid irrespective of the movement direction. The time to onset of EMC activity of OI, OE, RA and MF varied with the movement direction, being activated earliest when the prime action of the muscle opposed the reactive forces associated with the specific limb movement. It is postulated that the non-direction-specific contraction of TrA may be related to the control of trunk. stability independent of the requirement for direction-specific control of the centre of gravity in relation to the base of support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid shoulder movement is preceded by contraction of the abdominal muscles to prepare the body for the expected disturbance to postural equilibrium and spinal stability provoked by the reactive forces resulting from the movement. The magnitude of the reactive forces is proportional to the inertia of the limb. The aim of the study was to investigate if changes in the reaction time latency of the abdominal muscles was associated with variation in the magnitude of the reactive forces resulting from variation in limb speed. Fifteen participants performed shoulder flexion at three different speeds (fast, natural and slow). The onset of EMG of the abdominal muscles, erector spinae and anterior deltoid (AD) was recorded using a combination of fine-wire and surface electrodes. Mean and peak velocity was recorded for each limb movement speed for five participants. The onset of transversus abdominis (TrA) EMG preceded the onset of AD in only the fast movement condition. No significant difference in reaction time latency was recorded between the fast and natural speed conditions for all muscles. The reaction time of each of the abdominal muscles relative to AD was significantly delayed with the slow movement compared to the other two speeds. The results indicate that the reaction time latency of the trunk muscles is influenced by limb inertia only with limb movement below a threshold velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design. Prospective clinical electromyographic study in adolescents with idiopathic scoliosis and control group. Objective. To evaluate electromyographic amplitude from erector spinae muscles of patients with idiopathic scoliosis in comparison with control volunteers without spinal deformities. Summary of Background Data. Previous studies have indicated an increased electromyographic activity in paravertebral muscles in the convex side of the scoliotic curvature. However, in previous studies there is the absence or poor description of methods used, and some studies were conducted before the recording and processing recommendations for surface electromyographic signals had been described. Methods. Thirty individuals, matched by sex, age, and body mass index, were divided into two groups: scoliosis and control. The electric activity of the erector spinae muscles was determined by surface electromyography on both sides of the three levels of spine: T8, L2, and L5. Results. Normalized electromyographic amplitudes of erector spinae muscles, in the convex and concave sides of the apex region of the scoliotic curve in the thoracic and lumbar regions, were not significantly different. Also, there was no significant difference between the muscles of these regions when the scoliosis group was compared with the control group. The erector spinae muscle at the L5 level, representing the lower vertebral limit of the lumbar scoliotic curve, had significantly higher electromyographic activity on the convex side. However, the same alteration was shown in the control group homologous muscle (on the left side). Conclusion. Erector spinae muscles on the convex and concave sides at the curvature apex in patients with idiopathic scoliosis and small magnitude of curves did not show significant differences in electromyographic amplitude. Future studies should evaluate whether intragroup activation differences, at the L5 level in 80% of the maximum voluntary isometric contractions with predominance of the left side of the vertebral column, have any relation to the condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Endothelin-1 (ET-1), a potent vasoconstrictor peptide, acts mainly through the Gprotein-coupled ET(A) receptor (ET(A)R). Increased vascular ET-1 production and constrictor sensitivity have been observed in various cardiovascular diseases, including hypertension, as well as erectile dysfunction. The internal pudendal artery (IPA) supplies blood to the vagina and clitoris. Inadequate blood flow through the IPA may lead to insufficient vaginal engorgement and clitoral tumescence. Aim. Characterize the effects of ET-1 on the IPA and clitoral artery (CA). Methods. IPA and CA from female Sprague Dawley rats (225-250 g) were mounted in myograph chambers. Arterial segments were submitted to increasing concentrations of ET-1 (10-10-10-6 M). Segments were incubated with the ET(A)R antagonist, atrasentan (10-8 M) or the Rho-kinase inhibitor, Y-27632 (10-6 M) 30 minutes prior to agonist exposure. All E(max) values are expressed as % KCl-induced maximal contraction. ET(A)R, RhoA, and Rho-kinase expression from IPA was evaluated by Western blot. mRNA of preproET-1, ET(A)R, ET(B)R, RhoA, and Rho-kinase were measured by real time PCR. Main Outcome Measures. ET-1 constrictor sensitivity in IPA and CA, protein expression and messenger RNA levels of ET-1-mediated constriction components. Results. ET-1 concentration-dependently contracted IPA (% Contraction and pD2, respectively: 156 +/- 18, 8.2 +/- 0.1) and CA (163 +/- 12, 8.8 +/- 0.08), while ET(A)R antagonism reduced ET-1-mediated contraction (IPA: 104 +/- 23, 6.4 +/- 0.2; CA: 112 +/- 17, 6.6 +/- 0.08). Pretreatment with Y-27632 significantly shifted ET-1 pD2 in IPA (108 +/- 24, 7.9 +/- 0.1) and CA (147 +/- 58 and 8.0 +/- 0.25). Protein expression of ET(A)R, ET(B)R, RhoA, and Rho-kinase were detected in IPA. IPA and CA contained preproET-1, ET(A)R, ET(B)R, RhoA, and Rho-kinase message. Conclusion. We observed that the IPA and CA are sensitive to ET-1, signaling through the ET(A)R and Rho-kinase pathway. These data indicate that ET-1 may play a role in vaginal and clitoral blood flow and may be important in pathologies where ET-1 levels are elevated. Allahdadi KJ, Hannan JL, Tostes RC, and Webb RC. Endothelin-1 induces contraction of female rat internal pudendal and clitoral arteries through ETA receptor and Rho-kinase activation. J Sex Med 2010;7:2096-2103.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to verify whether AC biosusceptometry (ACB) is suitable for monitoring gastrointestinal (GI) contraction directly from smooth muscle in dogs, comparing with electrical recordings simultaneously. All experiments were performed in dogs with magnetic markers implanted under the serosa of the right colon and distal stomach, and their movements were recorded by ACB. Monopolar electrodes were implanted close to the magnetic markers and their electric potentials were recorded by electromyography (EMG). The effects of neostigmine, hyoscine butylbromide and meal on gastric and colonic parameters were studied. The ACB signal from the distal stomach was very similar to EMG; in the colonic recordings, however, within the same low-frequency band, ACB and EMG signals were characterized by simultaneity or a widely changeable frequency profile with time. ACB recordings were capable of demonstrating the changes in gastric and colonic motility determined by pharmacological interventions as well as by feeding. Our results reinforce the importance of evaluating the mechanical and electrical components of motility and show a temporal association between them. ACB and EMG arecomplementary for studying motility, with special emphasis on the colon. ACB offers an accurate method for monitoring in vivo GI motility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To investigate the effects of chronic ethanol consumption on nitric oxide (NO)-mediated relaxation in rat cavernosal smooth muscle (CSM). METHODS Male wistar rats were divided into 2 groups: control and ethanol. CSM obtained from both groups were mounted in organ chambers for measurement of isometric tension. Contraction of the strips was induced by electrical field stimulation (EFS, 1-32 Hertz) and phenylephrine. We also evaluated the effect of ethanol consumption on the relaxation induced by acetylcholine (0.01-1000 mu mol L(-1)), sodium nitroprusside (SNP, 0.01-1000 mu mol L(-1)), or EFS (1-32 Hz) in strips precontracted with phenylephrine (10 mu mol L(-1)). Blood ethanol, serum testosterone levels, and basal nitrate generation were determined. Immunoexpression of endothelial NO synthase (eNOS) and inducible NO synthase (iNOS) was also accessed. RESULTS Ethanol intake for 4 weeks significantly increased noradrenergic nerve-mediated contractions of CSM in response to EFS. The endothelium-dependent relaxation induced by acetylcholine decreased after the ethanol treatment. Ethanol consumption decreased serum testosterone levels but did not affect the nitrate levels on rat CSM. The mRNA and protein levels for eNOS and iNOS receptors were increased in CSM from ethanol-treated rats. CONCLUSIONS Ethanol consumption reduces endothelium-dependent relaxation induced by acetylcholine, but does not affect SNP or EFS-induced relaxation, suggesting that ethanol disrupts the endothelial function. Despite the overexpression of eNOS and iNOS in ethanol-treated rats, the impaired relaxation induced by acetylcholine may suggest that chronic ethanol consumption induces endothelial dysfunction. UROLOGY 74: 1250-1256, 2009. (C) 2009 Published by Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To investigate the effects of chronic ethanol consumption and diabetes on nitric oxide (NO)-mediated relaxation of cavernosal smooth muscle (CSM). MATERIAL AND METHODS Male Wistar rats were divided into four groups: control, isocaloric, diabetic and ethanol-diabetic. The CSMs were mounted in organ chambers for measurement of isometric tension. Contraction of the strips was induced by electrical field stimulation (EFS, 1-32 Hz) and phenylephrine. We also evaluated the effect of ethanol consumption on the relaxation induced by acetylcholine (ACh; 0.01-1000 mu mol/L), sodium nitroprusside (SNP, 0.01-1000 mu mol/L) or EFS (1-32 Hz) in strips pre-contracted with phenylephrine (10 mu mol/L). Immunoexpression of endothelial NO synthase (eNOS) and inducible NOS (iNOS) was also accessed. RESULTS The endothelium-dependent relaxation induced by ACh was decreased in CSM from ethanol-diabetic rats when compared with the controls, with a mean (sem) of 21 (4) vs 37 (2)%. Similarly, the potency and maximal responses induced by SNP were reduced in the ethanol-diabetic [3.97 (0.38) and 85 (1)%, respectively] and diabetic groups [3.78 (0.56) and 81 (2)%, respectively] when compared with the controls [5.3 (0.22) and 90 (3)%, respectively] and isocaloric [5.3 (0.19) and 92 (1)%, respectively] groups. Noradrenergic nerve-mediated contractions of CSM in response to EFS were increased in rats from ethanol-diabetic and diabetic groups when compared with the control and isocaloric groups. Conversely, there were no differences in EFS-induced relaxation among the groups. The immunostaining assays showed overexpression of eNOS and iNOS in the CSM from diabetic and ethanol-diabetic rats when compared with the control and isocaloric rats. CONCLUSION There was an impairment of relaxation of CSM from ethanol-diabetic and diabetic rats that involved a decrease in the NO-cyclic guanosine monophosphate signalling pathway by endothelium-dependent mechanisms accompanied by a change in the CSM contractile sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature shows contradictory results regarding the role of composite shrinkage and elastic modulus as determinants of polymerization stress. The present study aimed at a better understanding of the test mechanics that could explain such divergences among studies. The hypothesis was that the effects of composite shrinkage and elastic modulus on stress depend upon the compliance of the testing system. A commonly used test apparatus was simulated by finite element analysis, with different compliance levels defined by the bonding substrate (steel, glass, composite, or acrylic). Composites with moduli between 1 and 12 GPa and shrinkage values between 0.5% and 6% were modeled. Shrinkage was simulated by thermal analogy. The hypothesis was confirmed. When shrinkage and modulus increased simultaneously, stress increased regardless of the substrate. However, if shrinkage and modulus were inversely related, their magnitudes and interaction with rod material determined the stress response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The role of inorganic content on physical properties of resin composites is well known. However, its influence on polymerization stress development has not been established. The aim of this investigation was to evaluate the influence of inorganic fraction on polymerization stress and its determinants, namely, volumetric shrinkage, elastic modulus and degree of conversion. Methods. Eight experimental composites containing 1:1 BisGMA (bisphenylglycidyl dimethacrylate): TEGDMA (triethylene glycol dimethacrylate) (in mol) and barium glass at increasing concentrations from 25 to 60 vol.% (5% increments) were tested. Stress was determined in a universal test machine using acrylic as bonding substrate. Nominal polymerization stress was obtained diving the maximum load by the cross-surface area. Shrinkage was measured using a water picnometer. Elastic modulus was obtained by three-point flexural test. Degree of conversion was determined by FT-Raman spectroscopy. Results. Polymerization stress and shrinkage showed inverse relationships with filler content (R(2) = 0.965 and R(2) = 0.966, respectively). Elastic modulus presented a direct correlation with inorganic content (R(2) = 0.984). Degree of conversion did not vary significantly. Polymerization stress showed a strong direct correlation with shrinkage (R(2) = 0.982) and inverse with elastic modulus (R(2) = 0.966). Significance. High inorganic contents were associated with low polymerization stress values, which can be explained by the reduced volumetric shrinkage presented by heavily filled composites. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of composite organic content on polymerization stress development remains unclear. It was hypothesized that stress was directly related to differences in degree of conversion, volumetric shrinkage, elastic modulus, and maximum rate of polymerization encountered in composites containing different BisGMA (bisphenylglycidyl dimethacrylate) concentrations and TEGDMA ( triethylene glycol dimethacrylate) and/or BisEMA ( ethoxylated bisphenol-A dimethacrylate) as co-monomers. Stress was determined in a tensilometer. Volumetric shrinkage was measured with a mercury dilatometer. Elastic modulus was obtained by flexural test. We used fragments of flexural specimens to determine degree of conversion by FT-Raman spectroscopy. Reaction rate was determined by differential scanning calorimetry. Composites with lower BisGMA content and those containing TEGDMA showed higher stress, conversion, shrinkage, and elastic modulus. Polymerization rate did not vary significantly, except for the lower value of the 66% TEGDMA composite. We used linear regressions to evaluate the association between polymerization stress and conversion (R-2 = 0.905), shrinkage ( R-2 = 0.825), and modulus ( R-2 = 0.623).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The purpose of this study was to investigate the effect of light-curing protocol on degree of conversion (DC), volume contraction (C), elastic modulus (E), and glass transition temperature (T(g)) as measured on a model polymer. It was a further aim to correlate the measured values with each other. Methods. Different light-curing protocols were used in order to investigate the influence of energy density (ED), power density (PD), and mode of cure on the properties. The modes of cure were continuous, pulse-delay, and stepped irradiation. DC was measured by Raman micro-spectroscopy. C was determined by pycnometry and a density column. E was measured by a dynamic mechanical analyzer (DMA), and T(g) was measured by differential scanning calorimetry (DSC). Data were submitted to two-and three-way ANOVA, and linear regression analyses. Results. ED, PD, and mode of cure influenced DC, C, E, and T(g) of the polymer. A significant positive correlation was found between ED and DC (r = 0.58), ED and E (r = 0.51), and ED and T(g) (r = 0.44). Taken together, ED and PD were significantly related to DC and E. The regression coefficient was positive for ED and negative for PD. Significant positive correlations were detected between DC and C (r = 0.54), DC and E (r = 0.61), and DC and T(g) (r = 0.53). Comparisons between continuous and pulse-delay modes of cure showed significant influence of mode of cure: pulse-delay curing resulted in decreased DC, decreased C, and decreased T(g). Influence of mode of cure, when comparing continuous and step modes of cure, was more ambiguous. A complex relationship exists between curing protocol, microstructure of the resin and the investigated properties. The overall performance of a composite is thus indirectly affected by the curing protocol adopted, and the desired reduction of C may be in fact a consequence of the decrease in DC. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electromyographic (EMG) studies have shown that a large number of trunk muscles are recruited during axial rotation. The functional roles of these trunk muscles in axial rotation are multiple and have not been well investigated. In addition, there is no information on the coupling torque at different exertion levels during axial rotation. The aim of the study was to investigate the functional roles of rectus abdominis. external oblique. internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus during isometric right and left axial rotation at 100%, 70%, 50% and 30% maximum voluntary contractions (MVC) in a standing position. The coupling torques in sagittal and coronal planes were measured during axial rotation to examine the coupling nature of torque at different levels of exertions. Results showed that the coupled sagittal torque switches from nil to flexion at maximum exertion of axial rotation. Generally, higher EMG activities were shown at higher exertion levels for all the trunk muscles. Significant differences in activity between the right and left axial rotation exertions were demonstrated in external oblique, internal oblique, latissimus dorsi and iliocostalis lumborum while no difference was shown in rectus abdominis and multifidus. These results demonstrated the different functional roles of trunk muscles during axial rotation. This is important considering that the abdominal and back muscles not only produce torque but also maintain the spinal posture and stability during axial rotation exertions. The changing coupling torque direction in the sagittal plane when submaximal to maximal exertions were compared may indicate the complex nature of the kinetic coupling of trunk muscles. (C) 2001 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.