988 resultados para Imaging system


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The problem of supersonic flow over a 5 degree half-angle cone with injection of gas through a porous section on the body into the boundary layer is studied experimentally. Three injected gases are used: helium, nitrogen, and RC318 (octafluorocyclobutane). Experiments are performed in a Mach 4 Ludwieg tube with nitrogen as the free stream gas. Shaping of the injector section relative to the rest of the body is found to admit a "tuned" injection rate which minimizes the strength of shock waves formed by injection. A high-speed schlieren imaging system with a framing rate of 290 kHz is used to study the instability in the region of flow downstream of injection, referred to as the injection layer. This work provides the first experimental data on the wavelength, convective speed, and frequency of the instability in such a flow. The stability characteristics of the injection layer are found to be very similar to those of a free shear layer. The findings of this work present a new paradigm for future stability analyses of supersonic flow with injection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atmospheric scattering plays a crucial rule in degrading the performance of electro optical imaging systems operating in the visible and infra-red spectral bands, and hence limits the quality of the acquired images, either through reduction of contrast or increase of image blur. The exact nature of light scattering by atmospheric media is highly complex and depends on the types, orientations, sizes and distributions of particles constituting these media, as well as wavelengths, polarization states and directions of the propagating radiation. Here we follow the common approach for solving imaging and propagation problems by treating the propagating light through atmospheric media as composed of two main components: a direct (unscattered), and a scattered component. In this work we developed a detailed model of the effects of absorption and scattering by haze and fog atmospheric aerosols on the optical radiation propagating from the object plane to an imaging system, based on the classical theory of EM scattering. This detailed model is then used to compute the average point spread function (PSF) of an imaging system which properly accounts for the effects of the diffraction, scattering, and the appropriate optical power level of both the direct and the scattered radiation arriving at the pupil of the imaging system. Also, the calculated PSF, properly weighted for the energy contributions of the direct and scattered components is used, in combination with a radiometric model, to estimate the average number of the direct and scattered photons detected at the sensor plane, which are then used to calculate the image spectrum signal to- noise ratio (SNR) in the visible near infra-red (NIR) and mid infra-red (MIR) spectral wavelength bands. Reconstruction of images degraded by atmospheric scattering and measurement noise is then performed, up to the limit imposed by the noise effective cutoff spatial frequency of the image spectrum SNR. Key results of this research are as follows: A mathematical model based on Mie scattering theory for how scattering from aerosols affects the overall point spread function (PSF) of an imaging system was developed, coded in MATLAB, and demonstrated. This model along with radiometric theory was used to predict the limiting resolution of an imaging system as a function of the optics, scattering environment, and measurement noise. Finally, image reconstruction algorithms were developed and demonstrated which mitigate the effects of scattering-induced blurring to within the limits imposed by noise.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Determining groundwater flow paths of infiltrated river water is necessary for studying biochemical processes in the riparian zone, but their characterization is complicated by strong temporal and spatial heterogeneity. We investigated to what extent repeat 3D surface electrical resistance tomography (ERT) can be used to monitor transport of a salt-tracer plume under close to natural gradient conditions. The aim is to estimate groundwater flow velocities and pathways at a site located within a riparian groundwater system adjacent to the perialpine Thur River in northeastern Switzerland. Our ERT time-lapse images provide constraints on the plume's shape, flow direction, and velocity. These images allow the movement of the plume to be followed for 35 m. Although the hydraulic gradient is only 1.43 parts per thousand, the ERT time-lapse images demonstrate that the plume's center of mass and its front propagate with velocities of 2x10(-4) m/s and 5x10(-4) m/s, respectively. These velocities are compatible with groundwater resistivity monitoring data in two observation wells 5 m from the injection well. Five additional sensors in the 5-30 m distance range did not detect the plume. Comparison of the ERT time-lapse images with a groundwater transport model and time-lapse inversions of synthetic ERT data indicate that the movement of the plume can be described for the first 6 h after injection by a uniform transport model. Subsurface heterogeneity causes a change of the plume's direction and velocity at later times. Our results demonstrate the effectiveness of using time-lapse 3D surface ERT to monitor flow pathways in a challenging perialpine environment over larger scales than is practically possible with crosshole 3D ERT.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Les traités scientifiques ne font que depuis peu d'années l'objet d'études en histoire des sciences. Pourtant, ces traités ont énormément à apporter car ils renseignent sur la manière de raisonner des auteurs, ainsi que sur le développement d'une discipline. Dans ce travail de doctorat, différents traités des maladies du système nerveux ont été dépouillés, notamment le traité de Sémiologie des affections du système nerveux (1914) de Jules Dejerine (1849-1917). Ce traité a été analysé de trois manières différentes. Il a tout d'abord été comparé à une édition précédente publiée sous forme de chapitre (1901), révélant un large remodelage du contenu du traité, suggérant une évolution rapide de la discipline neurologique en l'espace de quelques années. Deuxièmement, l'analyse de la Sémiologie a permis de recréer un réseau de professionnels avec qui Jules Dejerine était en contact et, en parcourant les livres publiés par ces auteurs, il a été possible de décrire de quelle manière ces auteurs se citent mutuellement. Finalement, ces livres contiennent de nombreuses illustrations, qui sont associées à la notion de « preuve » : les auteurs utilisent des images sous forme de dessins, de photographies ou de schémas qui illustrent des patients ou des pièces anatomiques pour « montrer » la maladie ou la lésion. Chaque illustration a un rôle à jouer pour décrire la lésion, montrer la progression de la maladie et elle aide le médecin à poser le diagnostic. Grâce à ces trois axes de recherche, un traité devient un outil de travail dynamique, qui évolue au fil des rééditions, influencé par les critiques et commentaires retrouvés dans d'autres traités et articles, et par les progrès accomplis dans la discipline traitée. Des, passages et certaines images de l'ouvrage circulent également de traité en traité et véhiculent l'autorité de l'auteur de ces passages et images qui en viennent à représenter la maladie. Ce transfert d'images joue également un rôle dans la standardisation du diagnostic et dans l'unification de la neurologie à travers le monde occidental au début du XXe siècle, une période charnière pour l'histoire de la médecine. -- Au début du XXe siècle, la neurologie est une jeune spécialité médicale qui se développe rapidement. Les différents médecins publient des traités, communiquent entre eux et échangent leurs données. Un traité scientifique est un outil de travail dynamique qui évolue avec les rééditions et le développement d'une discipline. Ces ouvrages recèlent toutes sortes d'informations et leur analyse ne fait que depuis peu de temps l'objet d'études en histoire des sciences. Ces traités regorgent notamment d'illustrations qui sont associées à la notion de « preuve » : les auteurs utilisent des images sous forme de dessins, de photographies ou de schémas qui représentent des patients ou des pièces anatomiques afin de « montrer » la maladie ou la lésion. Chaque illustration a un rôle à jouer pour décrire la pathologie, montrer la progression de la maladie et elle aide le médecin à poser le diagnostic. Les auteurs des traités, qui viennent d'Europe et d'Amérique du Nord, se citent mutuellement, permettant au lecteur de recréer leur réseau de professionnels au niveau international. De plus, comme ces auteurs réutilisent les observations et les illustrations des autres, celles-ci circulent de traité en traité et en viennent à représenter la maladie. Ce transfert d'images joue également un rôle dans la standardisation du diagnostic et dans l'unification de la neurologie à travers le monde occidental au début du XXe siècle, une période charnière pour l'histoire de la médecine. -- Until recently, the study of textbooks has been neglected in the history of the sciences. However, textbooks can provide fruitful sources of information regarding the way authors work and the development of a particular discipline. This dissertation reviews editions of a single textbook, the Sémiologie des affections du système nerveux (1914) by Jules Dejerine (1849-1917). This textbook enabled the description of three axes of research. Firstly, by comparing the book to a first edition published as a chapter, one can acknowledge an extensive remodeling of the content of the book, suggesting a vast increase in knowledge over time. Secondly, by looking at the authors that Dejerine quotes repeatedly, it becomes possible to recreate his professional network, to review the works of these authors and to determine how they cross-reference each other. Thirdly, these textbooks contain numerous medical illustrations, which are linked with the concept of "proof;" the authors demonstrate a willingness to "show" the lesion or the pathology by publishing an image. Drawings, schematic representations, radiographies, or photographs of patients or of anatomical preparations all have their own purpose in describing the lesion and the progression of the disease. They assist in the diagnosis of the pathology. By looking at all of these aspects, it is therefore possible to conclude that a neurological textbook is a dynamic object that evolves through re-editions, comments and references found in other textbooks and by the circulations of parts of these books, such as the images. The illustrations also carry the author's authority, since their ongoing use claims that the work by the owner of the image has been endorsed by others. At the same time, it validates the borrowers' arguments. By using medical illustrations from different authors worldwide, the authors are also making a claim to a common language, to a similar way of examining patients, and about how much they depend on medical imagery to prove their points. In that sense, by focusing upon these textbooks, one can affirm that neurology already existed as a worldwide specialty at the turn of the twentieth century. Much more than mere accompaniments to the text, images were of paramount importance to the unification of neurology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O Breast Imaging Reporting and Data System (BI-RADS™), do American College of hRadiology, foi concebido para padronizar o laudo mamográfico e reduzir os fatores de confusão na descrição e interpretação das imagens, além de facilitar o monitoramento do resultado final. OBJETIVO: Identificar a maneira como vem sendo utilizado o BI-RADS™, gerando informações que possam auxiliar o Colégio Brasileiro de Radiologia a desenvolver estratégias para aperfeiçoar o seu uso. MATERIAIS E MÉTODOS: Os dados foram coletados na cidade de Goiânia, GO. Foram solicitados os exames de mamografia anteriores a todas as mulheres que se dirigiram ao serviço para realização de mamografia entre janeiro/2003 e junho/2003. Foram incluídos na análise exames anteriores, realizados entre 1/7/2001 e 30/6/2003. RESULTADOS: Foram coletados 104 laudos anteriores, emitidos por 40 radiologistas de 33 diferentes serviços. Dos 104 laudos, 77% (n = 80) utilizavam o BI-RADS™. Destes, apenas 15% (n = 12) eram concisos, nenhum utilizava a estrutura e organização recomendadas pelo sistema, 98,75% (n = 79) não respeitavam o léxico e 65% (n = 51) não faziam recomendação de conduta. CONCLUSÃO: O BI-RADS™, apesar de bastante utilizado, não foi reconhecido como sistema para padronização dos laudos. Foi usado quase exclusivamente como forma de classificação final dos exames.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJETIVO: Avaliar artigos, na literatura, que verificam o valor preditivo positivo das categorias 3, 4 e 5 do Breast Imaging Reporting and Data System (BI-RADS®). MATERIAIS E MÉTODOS: Foi realizada pesquisa na base de dados Medline utilizando os termos "predictive value" e "BI-RADS". Foram incluídos 11 artigos nesta revisão. RESULTADOS: O valor preditivo positivo das categorias 3, 4 e 5 variou entre 0% e 8%, 4% e 62%, 54% e 100%, respectivamente. Três artigos avaliaram, concomitantemente, os critérios morfológicos das lesões que apresentaram maior valor preditivo positivo na mamografia, sendo nódulo espiculado o critério com maior valor preditivo positivo. CONCLUSÃO: Houve grande variabilidade do valor preditivo positivo das categorias 3, 4 e 5 do BI-RADS® em todos os estudos, porém foram identificadas diferenças metodológicas que limitaram a comparação desses estudos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJETIVO: O objetivo deste trabalho foi avaliar o BI-RADS® como fator preditivo de suspeição de malignidade em lesões mamárias não palpáveis nas categorias 3, 4 e 5, correlacionando as mamografias com os resultados histopatológicos através do cálculo do valor preditivo positivo do exame mamográfico. MATERIAIS E MÉTODOS: Trezentas e setenta e uma pacientes encaminhadas a um serviço de referência em tratamento de câncer em Teresina, PI, para realização de exames histopatológicos em mama no período de julho de 2005 a março de 2008, por terem mamografia de categorias 3, 4 ou 5, tiveram seus exames revisados. Das 371 pacientes, 265 foram submetidas a biópsia por agulha grossa e 106, a marcação pré-cirúrgica. RESULTADOS: Em relação às mamografias, 11,32% foram classificadas como categoria 3, 76,28% como categoria 4 e 12,4% como categoria 5. Os resultados histológicos demonstraram 24% de exames positivos para malignidade. Os valores preditivos positivos das categorias 3, 4 e 5 foram, respectivamente, de 7,14%, 16,96% e 82,61%. Foram calculados os valores preditivos positivos, separadamente, para as biópsias percutâneas (7,14%, 15,76%, 76,47%) e para as marcações pré-cirúrgicas (7,14%, 20%, 100%). CONCLUSÃO: Achados malignos foram subestimados pelo laudo radiológico e houve superestimação de achados benignos, o que resultou na realização desnecessária de alguns procedimentos invasivos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To evaluate the BI-RADS as a predictive factor of suspicion for malignancy in breast lesions by correlating radiological with histological results and calculating the positive predictive value for categories 3, 4 and 5 in a breast cancer reference center in the city of São Paulo. Materials and Methods Retrospective, analytical and cross-sectional study including 725 patients with mammographic and/or sonographic findings classified as BI-RADS categories 3, 4 and 5 who were referred to the authors' institution to undergo percutaneous biopsy. The tests results were reviewed and the positive predictive value was calculated by means of a specific mathematical equation. Results Positive predictive values found for categories 3, 4 and 5 were respectively the following: 0.74%, 33.08% and 92.95%, for cases submitted to ultrasound-guided biopsy, and 0.00%, 14.90% and 100% for cases submitted to stereotactic biopsy. Conclusion The present study demonstrated high suspicion for malignancy in lesions classified as category 5 and low risk for category 3. As regards category 4, the need for systematic biopsies was observed.