946 resultados para GAS-LIQUID FLOW
Resumo:
In this study, an in situ derivatization and extraction method for the determination of pentachlorophenol (PCP) has been applied successfully in the analysis of water samples. The PCP derivative analysis was performed by gas-liquid chromatography with electron capture detection. The limit of detection of the method is 1 μg/L and recoveries averaged 78-108% for PCP acetate at levels of 2, 10 and 20 μg/L.
Resumo:
The freshwater planktonic alga Kirchneriella aperta was grown in batch cultures to stationary growth phase. Copper and lead complexation properties of the exudate from stationary and exponential growth phases were determined by titrations monitored by ion-selective electrodes. Molecular weight fractionation dialysis) and analysis of the titration data (Scatchard Plot) revealed that K. aperta releases metal-complexing ligands. Copper is associated with low and high molecular weight compounds, whereas lead forms complexes with only high molecular weight compounds. Gas-liquid chromatography showed that mannose and rhamnose make up 74% of the total high molecular weight organic material, with uronic acids present at 19%.
Resumo:
A bounded upwinding scheme for numerical solution of hyperbolic conservation laws and Navier-Stokes equations is presented. The scheme is based on convection boundedness criterion and total variation diminishing stability criteria and developed by employing continuously differentiable functions. The accuracy of the scheme is verified by assessing the error and observed convergence rate on 1-D benchmark test cases. A comparative study between the new scheme and conventional total variation diminishing/convection boundedness criterion-based upwind schemes to solve standard nonlinear hyperbolic conservation laws is also accomplished. The scheme is then examined in the simulation of Newtonian and non-Newtonian fluid flows of increasing complexity; a satisfactory agreement has been observed in terms of the overall behavior. Finally, the scheme is used to study the hydrodynamics of a gas-solid flow in a bubbling fluidized bed. © 2013 John Wiley & Sons, Ltd.
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Rayleigh optical activities of small hydrogen-bonded methanol clusters containing two to five molecules are reported. For the methanol trimer, tetramer, and pentamer both cyclic and linear structures are considered. After the geometry optimizations, the dipole moments and the dipole polarizabilities (mean, interaction, and anisotropic components) are calculated using HF, MP2 and DFT (B3LYP, B3P86 and BH&HLYP) with aug-cc-pVDZ extended basis set. The polarizabilities are used to analyse the depolarization ratios and the Rayleigh scattering activities. The variations in the activity and in the depolarization for Rayleigh scattered radiation with the increase in the cluster size for both cyclic and linear structures are analysed.
Resumo:
Das Phasenverhalten und die Grenzflächeneigenschaften vonPolymeren in superkritischer Lösung werden anhand einesvergröberten Kugel-Feder-Modells für das ReferenzsystemHexadekan-CO2 untersucht. Zur Bestimmung der Parameter imPotential setzt man die kritischen Punkte von Simulation undExperiment gleich. Wechselwirkungen zwischen beidenKomponenten werden durch eine modifizierteLorentz-Berthelot-Regel modelliert. Die Übereinstimmung mitden Experimenten ist sehr gut - insbesondere kann dasPhasendiagramm des Mischsystems inklusive kritischer Linienreproduziert werden. Ein Vergleich mit numerischenStörungsrechnungen (TPT1) liefert eine qualitativeÜbereinstimmung und Hinweise zur Verbesserung derverwendeten Zustandsgleichung. Aufbauend auf diesen Betrachtungen werden die Frühstadiender Keimbildung untersucht. Für das Lennard-Jones-Systemwird zum ersten Mal der Übergang vom homogenen Gas zu einemeinzelnen Tropfen im endlichen Volumen direkt nachgewiesenund quantifiziert. Die freie Energie von kleinen Clusternwird mit einem einfachen, klassischen Nukleationsmodellbestimmt und nach oben abgeschätzt. Die vorgestellten Untersuchungen wurden durch eineWeiterentwicklung des Umbrella-Sampling-Algorithmusermöglicht. Hierbei wird die Simulation in mehrereSimulationsfenster unterteilt, die nacheinander abgearbeitetwerden. Die Methode erlaubt eine Bestimmung derFreien-Energie-Landschaft an einer beliebigen Stelle desPhasendiagramms. Der Fehler ist kontrollierbar undunabhängig von der Art der Unterteilung.
Resumo:
When non-adsorbing polymers are added to an isotropic suspension of rod-like colloids, the colloids effectively attract each other via depletion forces. Monte Carlo simulations were performed to study the phase diagram of such rod-polymer mixtures. The colloidal rods were modelled as hard spherocylinders; the polymers were described as spheres of the same diameter as the rods. The polymers may overlap with no energy cost, while overlap of polymers and rods is forbidden. In this thesis the emphasis was on the depletion effects caused by the addition of spheres on the isotropic phase of rod-like particles. Although most of the present experimental studies consider systems close to or beyond the isotropic-nematic transition, the isotropic phase with depletion interactions turns out to be a not less interesting topic. First, the percolation problem was studied in canonical simulations of a system of hard rods and soft spheres, where the amount of depletant was kept low to prevent phase separation of the mixture. The lowering of the percolation threshold seen in experiment is confirmed to be due to the depletion interactions. The local changes in the structure of the fluid of rods, which were measured in the simulations, indicated that the depletion forces enhance local alignment and aggregation of the rods. Then, the phase diagram of isotropic-isotropic demixing of short spherocylinders was calculated using grand canonical ensemble simulations with successive umbrella sampling. Finite size scaling analysis allowed to estimate the location of the critical point. Also, estimates for the interfacial tension between the coexisting isotropic phases and analyses of its power-law behaviour on approach of the critical point are presented. The obtained phase diagram was compared to the predictions of the free volume theory. After an analysis of the bulk, the phase behaviour in confinement was studied. The critical point of gas-liquid demixing is shifted to higher concentrations of rods and smaller concentrations of spheres due to the formation of an orientationally ordered surface film. If the separation between the walls becomes very small, the critical point is shifted back to smaller concentrations of rods because the surface film breaks up. A method to calculate the contact angle of the liquid-gas interface with the wall is introduced and the wetting behaviour on the approach to the critical point is analysed.
Resumo:
Understanding liquid flow at the vicinity of solid surfaces is crucial to the developmentrnof technologies to reduce drag. One possibility to infer flow properties at the liquid-solid interface is to compare the experimental results to solutions of the Navier-Stokes equations assuming the no-slip boundary condition (BC) or the slip BC. There is no consensus in the literature about which BC should be used to model the flow of aqueous solutions over hydrophilic surfaces. Here, the colloidal probe technique is used to systematically address this issue, measuring forces acting during drainage of water over a surface. Results show that experimental variables, especially the cantilever spring constant, lead to the discrepancy observed in the literature. Two different parameters, calculated from experimental variables, could be used to separate the data obtained in this work and those reported in the literature in two groups: one explained with the no-slip BC, and another with the slip BC. The observed residual slippage is a function of instrumental variables, showing a trend incompatible with the available physical justifications. As a result, the no-slip is the more appropriate BC. The parameters can be used to avoid situations where the no-slip BC is not satisfied.
Resumo:
Die pneumatische Zerstäubung ist die häufigste Methode der Probenzuführung von Flüssigkeiten in der Plasmaspektrometrie. Trotz der bekannten Limitierungen dieser Systeme, wie die hohen Probenverluste, finden diese Zerstäuber aufgrund ihrer guten Robustheit eine breite Anwendung. Die flussratenabhängige Aerosolcharakteristik und pumpenbasierte Signalschwankungen limitieren bisher Weiterentwicklungen. Diese Probleme werden umso gravierender, je weiter die notwendige Miniaturisierung dieser Systeme fortschreitet. Der neuartige Ansatz dieser Arbeit basiert auf dem Einsatz modifizierter Inkjet-Druckerpatronen für die Dosierung von pL-Tropfen. Ein selbst entwickelter Mikrokontroller ermöglicht den Betrieb von matrixkodierten Patronen des Typs HP45 mit vollem Zugriff auf alle essentiellen Betriebsparameter. Durch die neuartige Aerosoltransportkammer gelang die effiziente Kopplung des Tropfenerzeugungssystems an ein ICP-MS. Das so aufgebaute drop-on-demand-System (DOD) zeigt im Vergleich zu herkömmlichen und miniaturisierten Zerstäubern eine deutlich gesteigerte Empfindlichkeit (8 - 18x, elementabhängig) bei leicht erhöhtem, aber im Grunde vergleichbarem Signalrauschen. Darüber hinaus ist die Flexibilität durch die große Zahl an Freiheitsgraden des Systems überragend. So ist die Flussrate über einen großen Bereich variabel (5 nL - 12,5 µL min-1), ohne dabei die primäre Aerosolcharakteristik zu beeinflussen, welche vom Nutzer durch Wahl der elektrischen Parameter bestimmt wird. Das entwickelte Probenzuführungssystem ist verglichen mit dem pneumatischen Referenzsystem weniger anfällig gegenüber Matrixeffekten beim Einsatz von realen Proben mit hohen Anteilen gelöster Substanzen. So gelingt die richtige Quantifizierung von fünf Metallen im Spurenkonzentrationsbereich (Li, Sr, Mo, Sb und Cs) in nur 12 µL Urin-Referenzmaterial mittels externer Kalibrierung ohne Matrixanpassung. Wohingegen beim pneumatischen Referenzsystem die aufwändigere Standardadditionsmethode sowie über 250 µL Probenvolumen für eine akkurate Bestimmung der Analyten nötig sind. Darüber hinaus wird basierend auf der Dosierfrequenz eines dualen DOD-Systems eine neuartige Kalibrierstrategie vorgestellt. Bei diesem Ansatz werden nur eine Standard- und eine Blindlösung anstelle einer Reihe unterschiedlich konzentrierter Standards benötigt, um eine lineare Kalibrierfunktion zu erzeugen. Zusätzlich wurde mittels selbst entwickelter, zeitlich aufgelöster ICP-MS umfangreiche Rauschspektren aufgenommen. Aus diesen gelang die Ermittlung der Ursache des erhöhten Signalrauschens des DOD, welches maßgeblich durch das zeitlich nicht äquidistante Eintreffen der Tropfen am Detektor verursacht wird. Diese Messtechnik erlaubt auch die Detektion einzeln zugeführter Tropfen, wodurch ein Vergleich der Volumenverteilung der mittels ICP-MS detektierten, gegenüber den generierten und auf optischem Wege charakterisierten Tropfen möglich wurde. Dieses Werkzeug ist für diagnostische Untersuchungen äußerst hilfreich. So konnte aus diesen Studien neben der Aufklärung von Aerosoltransportprozessen die Transporteffizienz des DOD ermittelt werden, welche bis zu 94 Vol.-% beträgt.