368 resultados para Eccentric
Resumo:
Abstract: Amorimia exotropica is an important plant associated with sudden death in cattle in Southern Brazil. In order to understand the mechanisms by which A. exotropica causes acute lesions in the heart and kidney of intoxicated animals, an experiment was conducted to determine the histopathology and ultrastructure of myocardial and renal lesions of intoxicated rabbits. After receiving 18g/kg of dried plant, six rabbits died suddenly. At necropsy, the liver was swollen and no other macroscopic lesions were observed. Histologically, centrolobular and midzonal hepatocytes were vacuolated. These vacuoles were strong PAS stained positive, suggesting that they corresponded to glycogen accumulations. In some regions of the ventricular septum and ventricles were found vacuoles of different sizes and the kidneys of two rabbits showed vacuolar degeneration on distal convoluted tubules. Ultrastructurally, the myocardium had cardiomyocytes swelling with separation of myofibrils bundles and rupture and disorganization of the sarcomeres. The mitochondria displayed swelling, disorganization, disruption of the mitochondrial cristae, and electron-dense matrix. Some mitochondria exhibited eccentric projections of their membranes with disruption of both outer and inner membranes. The sarcoplasmic reticulum had no alterations, whereas the T-tubule system was occasionally dilated and ruptured. The kidneys had mitochondrial swelling with disorganization and disruption of the mitochondrial cristae. The vacuoles result from the swelling of the endoplasmatic reticulum and usually were located between two basolateral infoldings and mitochondria, occurring preferentially around the nucleus. The myocytes and T system damages induced by A. exotropica result in acute heart failure and death. Furthermore, this mechanism of cardiotoxicity may be common to all plant containing monofluoroacetate.
Resumo:
Tässä työssä tutkittiin vääntökuormitettua hitsattua koteloprofiilipuomia. Vääntökuormitus aiheuttaa koteloprofiiliin vinouttavan voimasysteemin, joka aiheuttaa kotelopalkkiin sekä poikittaisia taivutusjännityksiä että pitkittäisiä jännityksiä. Vinoutumisen aiheuttamia lisära-situksia on tutkittu analyyttisesti BEF-analogian avulla sekä elementtimenetelmää apuna käyttäen. Lisäksi vääntökuormitus aiheuttaa puomiin estetyn väännön jännityksiä. Väsymiskestoikää tutkittiin laboratoriossa suoritettujen väsytyskokeiden avulla sekä las-kennallisesti. Kestoikälaskennassa käytettiin tehollisen lovijännityksen menetelmää hitsin juuren puolen väsymisen arvioinnissa sekä hot spot- jännityksen menetelmää hitsin rajavii-van väsymisen arvioinnissa. Teholliset lovijännitykset sekä hot spot jännitykset ovat määri-tetty elementtimenetelmän avulla. Laboratoriokokeiden ja elementtimenetelmä laskennan perusteella saatiin rakenteen kes-toiän kannalta kriittiset detaljit määritettyä. Kriittiset detaljit sijaitsevat puomin päädyn rakenteissa. Tutkimuksessa saatiin selville, että kriittisten detaljien rakenteellisilla ja valmis-tusteknisillä ratkaisuilla on merkittävä vaikutus lopullisen tuotteen väsymiskestoikään.
Resumo:
The aim of this thesis was to research how slurry’s viscosity and rheology affect to pumping in peristaltic hose pump and in eccentric progressive cavity pump. In addition, it was researched the formed pressure pulsation in hose pump. Pressure pulsation was studied by pumping different slurries and by using different pipe materials. Pressure and power curves were determined for both used pumps. It was also determined NPSHR curve for the progressive cavity pump. Literature part of the thesis considered to distribute fluids to different rheology types, as well as theories and models to identify different rheology types. Special attention was paid to non-Newtonian fluids, which were also used in experimental part of this thesis. In addition, the literature part discusses about pumps, parameters for pump sizing, and pressure pulsation in hose pump. Starch, bentonite, and carboxymethyl cellulose slurries were used in the experimental part of this thesis. The slurries were pumped with Flowrox peristaltic hose pump (LPP-T32) and eccentric progressive cavity pump (C10/10). From the each slurry was taken a sample, and the samples were analyzed for concentration, viscosity and rheology type. The used pipe materials in pressure pulsation experiments were steel and elastic, and it was also used a prototype of pulsation dampener. The pulsation experiments indicated that the elastic pipe and the prototype of pulsation dampener attenuated pressure pulsation better than the steel pipe at low pressure levels. The differences between different materials disappeared when pressure level and pump rotation speed increased. In slurry experiments, pulsation was different depending on rheology and viscosity of the slurry. According to experiments, the rheology did not significantly affect to pump power consumption or efficiency.
Resumo:
Vibrations in machines can cause noise, decrease the performance, or even damage the machine. Vibrations appear if there is a source of vibration that excites the system. In the worst case scenario, the excitation frequency coincides with the natural frequency of the machine causing resonance. Rotating machines are a machine type, where the excitation arises from the machine itself. The excitation originates from the mass imbalance in the rotating shaft, which always exists in machines that are manufactured using conventional methods. The excitation has a frequency that is dependent on the rotational speed of the machine. The rotating machines in industrial use are usually designed to rotate at a constant rotational speed, the case where the resonances can be easily avoided. However, the machines that have a varying operational speed are more problematic due to a wider range of frequencies that have to be avoided. Vibrations, which frequencies equal to rotational speed frequency of the machine are widely studied and considered in the typical machine design process. This study concentrates on vibrations, which arise from the excitations having frequencies that are multiples of the rotational speed frequency. These vibrations take place when there are two or more excitation components in a revolution of a rotating shaft. The dissertation introduces four studies where three kinds of machines are experiencing vibrations caused by different excitations. The first studied case is a directly driven permanent magnet generator used in a wind power plant. The electromagnetic properties of the generator cause harmonic excitations in the system. The dynamic responses of the generator are studied using the multibody dynamics formulation. In another study, the finite element method is used to study the vibrations of a magnetic gear due to excitations, which frequencies equal to the rotational speed frequency. The objective is to study the effects of manufacturing and assembling inaccuracies. Particularly, the eccentricity of the rotating part with respect to non-rotating part is studied since the eccentric operation causes a force component in the direction of the shortest air gap. The third machine type is a tube roll of a paper machine, which is studied while the tube roll is supported using two different structures. These cases are studied using different formulations. In the first case, the tube roll is supported by spherical roller bearings, which have some wavinesses on the rolling surfaces. Wavinesses cause excitations to the tube roll, which starts to resonate at the frequency that is a half of the first natural frequency. The frequency is in the range where the machine normally operates. The tube roll is modeled using the finite element method and the bearings are modeled as nonlinear forces between the tube roll and the pedestals. In the second case studied, the tube roll is supported by freely rotating discs, which wavinesses are also measured. The above described phenomenon is captured as well in this case, but the simulation methodology is based on the flexible multibody dynamics formulation. The simulation models that are used in both of the last two cases studied are verified by measuring the actual devices and comparing the simulated and measured results. The results show good agreement.
Resumo:
Simple manual reaction time (MRT) to a visual target (S2) is shortened when a non-informative cue (S1) is flashed at the S2 location shortly before the onset of S2 (early facilitation). Afterwards, MRT to S2 appearing at the S1 location is lengthened (inhibition of return - IOR). Similar results have been obtained for saccadic reaction time (SRT). Moreover, when there is a temporal gap between offset of the fixation point (FP) and onset of a target (gap paradigm), SRT is shorter than SRT in an overlap paradigm (FP remains on). In the present study, we determined SRT to S2 (10º) after presenting S1 at the same eccentricity (10º) or at a parafoveal position (2º) in the same or in the opposite hemifield. In addition, we employed both gap and overlap paradigms. Twelve subjects were asked not to respond to S1 (2º or 10º) to the right or to the left of FP, but to respond by making a saccadic movement in response to S2. We obtained the following results: 1) a 40-ms gap effect, 2) an interaction between gap effect and IOR, 3) a 39-ms delay (IOR) when S2 appeared at the cued (S1) position, and 4) a smaller (17 ms) but significant inhibition when S1 occurred at 2º in the ipsilateral hemifield. Thus, a parafoveal (2º) S1 elicits an inhibition of SRT towards ipsilateral peripheral targets. Since an inhibition of the ipsilateral hemifield by a 1º eccentric cue has been reported to occur when manual responses are employed, we suggest that the postulated functional link between covert and overt orienting of attention is also valid for parafoveal cues.
Resumo:
Cardiac structures, function, and myocardial contractility are affected by food restriction (FR). There are few experiments associating undernutrition with hypertension. The aim of the present study was to analyze the effects of FR on the cardiac response to hypertension in a genetic model of hypertension, the spontaneously hypertensive rat (SHR). Five-month-old SHR were fed a control or a calorie-restricted diet for 90 days. Global left ventricle (LV) systolic function was evaluated in vivo by transthoracic echocardiogram and myocardial contractility and diastolic function were assessed in vitro in an isovolumetrically beating isolated heart (Langendorff preparation). FR reduced LV systolic function (control (mean ± SD): 58.9 ± 8.2; FR: 50.8 ± 4.8%, N = 14, P < 0.05). Myocardial contractility was preserved when assessed by the +dP/dt (control: 3493 ± 379; FR: 3555 ± 211 mmHg/s, P > 0.05), and developed pressure (in vitro) at diastolic pressure of zero (control: 152 ± 16; FR: 149 ± 15 mmHg, N = 9, P > 0.05) and 25 mmHg (control: 155 ± 9; FR: 150 ± 10 mmHg, N = 9, P > 0.05). FR also induced eccentric ventricular remodeling, and reduced myocardial elasticity (control: 10.9 ± 1.6; FR: 9.2 ± 0.9%, N = 9, P < 0.05) and LV compliance (control: 82.6 ± 16.5; FR: 68.2 ± 9.1%, N = 9, P < 0.05). We conclude that FR causes systolic ventricular dysfunction without in vitro change in myocardial contractility and diastolic dysfunction probably due to a reduction in myocardial elasticity.
Resumo:
Several indexes of myocardial contractility have been proposed to assess ventricular function in the isovolumetrically beating isolated heart. However, the conclusions reached on the basis of these indexes may be influenced by ventricular geometry rather than contractility itself. The objective of the present study was to assess the performance of widely used contractility indexes in the isovolumetrically beating isolated heart in two experimental models of hypertrophy, the spontaneously hypertensive rat (SHR) and infrarenal aortocava fistula. Compared to normotensive controls (N = 8), SHRs with concentric hypertrophy (N = 10) presented increased maximum rate of ventricular pressure rise (3875 ± 526 vs 2555 ± 359 mmHg/s, P < 0.05) and peak of isovolumetric pressure (187 ± 11 vs 152 ± 11 mmHg, P < 0.05), and decreased developed stress (123 ± 20 vs 152 ± 26 g/cm², P < 0.05) and slope of stress-strain relationship (4.9 ± 0.42 vs 6.6 ± 0.77 g/cm²/%). Compared with controls (N = 11), rats with volume overload-induced eccentric hypertrophy (N = 16) presented increased developed stress (157 ± 38 vs 124 ± 22 g/cm², P < 0.05) and slope of stress-strain relationship (9 ± 2 vs 7 ± 1 g/cm²/%, P < 0.05), and decreased maximum rate of ventricular pressure rise(2746 ± 382 vs 3319 ± 352 mmHg, P < 0.05) and peak of isovolumetric pressure (115 ± 14 vs 165 ± 13 mmHg/s, P < 0.05). The results suggested that indexes of myocardial contractility used in experimental studies may present opposite results in the same heart and may be influenced by ventricular geometry. We concluded that several indexes should be taken into account for proper evaluation of contractile state, in the isovolumetrically beating isolated heart.
Resumo:
Skeletal muscle force production following repetitive contractions is preferentially reduced when muscle is evaluated with low-frequency stimulation. This selective impairment in force generation is called low-frequency fatigue (LFF) and could be dependent on the contraction type. The purpose of this study was to compare LFF after concentric and eccentric maximal and submaximal contractions of knee extensor muscles. Ten healthy male subjects (age: 23.6 ± 4.2 years; weight: 73.8 ± 7.7 kg; height: 1.79 ± 0.05 m) executed maximal voluntary contractions that were measured before a fatigue test (pre-exercise), immediately after (after-exercise) and after 1 h of recovery (after-recovery). The fatigue test consisted of 60 maximal (100%) or submaximal (40%) dynamic concentric or eccentric knee extensions at an angular velocity of 60°/s. The isometric torque produced by low- (20 Hz) and high- (100 Hz) frequency stimulation was also measured at these times and the 20:100 Hz ratio was calculated to assess LFF. One-way ANOVA for repeated measures followed by the Newman-Keuls post hoc test was used to determine significant (P < 0.05) differences. LFF was evident after-recovery in all trials except following submaximal eccentric contractions. LFF was not evident after-exercise, regardless of exercise intensity or contraction type. Our results suggest that low-frequency fatigue was evident after submaximal concentric but not submaximal eccentric contractions and was more pronounced after 1-h of recovery.
Resumo:
We determined the effects of exercise training and detraining on the morphological and mechanical properties of left ventricular myocytes in 4-month-old spontaneously hypertensive rats (SHR) randomly divided into the following groups: sedentary for 8 weeks (SED-8), sedentary for 12 weeks (SED-12), treadmill-running trained for 8 weeks (TRA, 16 m/min, 60 min/day, 5 days/week), and treadmill-running trained for 8 weeks followed by 4 weeks of detraining (DET). At sacrifice, left ventricular myocytes were isolated enzymatically, and resting cell length, width, and cell shortening after stimulation at a frequency of 1 Hz (~25°C) were measured. Cell length was greater in TRA than in SED-8 (161.30 ± 1.01 vs 156.10 ± 1.02 μm, P < 0.05, 667 vs 618 cells, respectively) and remained larger after detraining. Cell width and volume were unaffected by either exercise training or detraining. Cell length to width ratio was higher in TRA than in SED-8 (8.50 ± 0.08 vs 8.22 ± 0.10, P < 0.05) and was maintained after detraining. Exercise training did not affect cell shortening, which was unchanged with detraining. TRA cells exhibited higher maximum velocity of shortening than SED-8 (102.01 ± 4.50 vs 82.01 ± 5.30 μm/s, P < 0.05, 70 cells per group), with almost complete regression after detraining. The maximum velocity of relengthening was higher in TRA cells than in SED-8 (88.20 ± 4.01 vs70.01 ± 4.80 μm/s, P < 0.05), returning to sedentary values with detraining. Therefore, exercise training affected left ventricle remodeling in SHR towards eccentric hypertrophy, which remained after detraining. It also improved single left ventricular myocyte contractile function, which was reversed by detraining.
Resumo:
Stretching has been widely used to increase the range of motion. We assessed the effects of a stretching program on muscle-tendon length, flexibility, torque, and activities of daily living of institutionalized older women. Inclusion/exclusion criteria were according to Mini-Mental State Examination (MMSE) (>13), Barthel Index (>13) and Lysholm Scoring Scale (>84). Seventeen 67 ± 9 year-old elderly women from a nursing home were divided into 2 groups at random: the control group (CG, N = 9) participated in enjoyable cultural activities; the stretching group (SG, N = 8) performed active stretching of hamstrings, 4 bouts of 1 min each. Both groups were supervised three times per week over a period of 8 weeks. Peak torque was assessed by an isokinetic method. Both groups were evaluated by a photogrammetric method to assess muscle-tendon length of uni- and biarticular hip flexors and hamstring flexibility. All measurements were analyzed before and after 8 weeks by two-way ANOVA with the level of significance set at 5%. Hamstring flexibility increased by 30% in the SG group compared to pre-training (76.5 ± 13.0° vs 59.5 ± 9.0°, P = 0.0002) and by 9.2% compared to the CG group (76.5 ± 13.0° vs 64.0 ± 12.0°, P = 0.0018). Muscle-tendon lengths of hip biarticular flexor muscles (124 ± 6.8° vs 118.3 ± 7.6°, 5.0 ± 7.0%, P = 0.031) and eccentric knee extensor peak torque were decreased in the CG group compared to pre-test values (-49.4 ± 16.8 vs -60.5 ± 18.9 Nm, -15.7 ± 20%, P = 0.048). The stretching program was sufficient to increase hamstring flexibility and a lack of stretching can cause reduction of muscle performance.
Resumo:
Abstract The reduction of skeletal muscle loss in pathological states, such as muscle disuse, has considerable effects in terms of rehabilitation and quality of life. Since there is no currently effective and safe treatment available for skeletal muscle atrophy, the search for new alternatives is necessary. Resistance exercise (RE) seems to be an important tool in the treatment of disuse-induced skeletal muscle atrophy by promoting positive functional (strength and power) and structural (hypertrophy and phenotypic changes) adaptive responses. Human and animal studies using different types of resistance exercise (flywheel, vascular occlusion, dynamic, isometric, and eccentric) have obtained results of great importance. However, since RE is a complex phenomenon, lack of strict control of its variables (volume, frequency, intensity, muscle action, rest intervals) limits the interpretation of the impact of the manipulation on skeletal muscle remodeling and function under disuse. The aim of this review is to critically describe the functional and morphological role of resistance exercise in disuse-induced skeletal muscle atrophy with emphasis on the principles of training.
Resumo:
Extracellular matrix and costamere proteins transmit the concentric, isometric, and eccentric forces produced by active muscle contraction. The expression of these proteins after application of passive tension stimuli to muscle remains unknown. This study investigated the expression of laminin and dystrophin in the soleus muscle of rats immobilized with the right ankle in plantar flexion for 10 days and subsequent remobilization, either by isolated free movement in a cage or associated with passive stretching for up to 10 days. The intensity of the macrophage response was also evaluated. One hundred and twenty-eight female Wistar rats were divided into 8 groups: free for 10 days; immobilized for 10 days; immobilized/free for 1, 3, or 10 days; or immobilized/stretched/free for 1, 3, or 10 days. After the experimental procedures, muscle tissue was processed for immunofluorescence (dystrophin/laminin/CD68) and Western blot analysis (dystrophin/laminin). Immobilization increased the expression of dystrophin and laminin but did not alter the number of macrophages in the muscle. In the stretched muscle groups, there was an increase in dystrophin and the number of macrophages after 3 days compared with the other groups; dystrophin showed a discontinuous labeling pattern, and laminin was found in the intracellular space. The amount of laminin was increased in the muscles treated by immobilization followed by free movement for 10 days. In the initial stages of postimmobilization (1 and 3 days), an exacerbated macrophage response and an increase of dystrophin suggested that the therapeutic stretching technique induced additional stress in the muscle fibers and costameres.
Resumo:
The purpose of this study was to test the hypothesis that the potentiation of dynamic function was dependent upon both length change speed and direction. Mouse EDL was cycled in vitro (25º C) about optimal length (Lo) with constant peak strain (± 2.5% Lo) at 1.5, 3.3 and 6.9 Hz before and after a conditioning stimulus. A single pulse was applied during shortening or lengthening and peak dynamic (concentric or eccentric) forces were assessed at Lo. Stimulation increased peak concentric force at all frequencies (range: 19 ± 1 to 30 ± 2%) but this increase was proportional to shortening speed, as were the related changes to concentric work/power (range: -15 ± 1 to 39 ± 1 %). In contrast, stimulation did not increase eccentric force, work or power at any frequency. Thus, results reveal a unique hysteresis like effect for the potentiation of dynamic output wherein concentric and eccentric forces increase and decrease, respectively, with work cycle frequency.
Resumo:
The purpose of this study was to test the hypothesis that the potentiation of dynamic function was dependent upon both length change speed and direction. Mouse EDL was cycled in vitro (250 C) about optimal length (Lo) with constant peak strain (± 2.5% Lo) at 1.5,3.3 and 6.9 Hz before and after a conditioning stimulus. A single pulse was applied during shortening or lengthening and peak dynamic (concentric or eccentric) forces were assessed at Lo. Stimulation increased peak concentric force at all frequencies (range: 19±1 to 30 ± 2%) but this increase was proportional to shortening speed, as were the related changes to concentric work/power (range: -15 ± 1 to 39 ± 1 %). In contrast, stimulation did not increase eccentric force, work or power at any frequency. Thus, results reveal a unique hysteresis like effect for the potentiation of dynamic output wherein concentric and eccentric forces increase and decrease, respectively, with work cycle frequency.
Resumo:
Duchenne muscular dystrophy is a X-linked muscle disease, which leads to alterations in membrane phospholipid fatty acid (FA) composition and skeletal muscle damage. Increased membrane saturated FA in muscular dystrophy may suggest its association with increased susceptibility (as being the cause or consequence) to muscle damage. It was hypothesised that increased saturation is positively correlated to increased muscle damage. Correlations were hypothesized to be greater in extensor digitorum longus (EDL) at 20 weeks compared to soleus (SOL) at 10 weeks in dystrophin deficient (mdx) mice. Increased saturation was correlated to damage in EDL at both 10 and 20 weeks, with stronger correlations at 10 weeks. The results suggest that membrane PL FA composition may be associated with damage through two possible means. Increased saturation may be a cause or consequence of membrane damage. Association of membrane composition with eccentric induced damage has underscored the importance of saturated PL FA compositions in damage to dystrophic myofibres.