979 resultados para Differential protection for power transformer
Resumo:
This article is concerned with the liability of search engines for algorithmically produced search suggestions, such as through Google’s ‘autocomplete’ function. Liability in this context may arise when automatically generated associations have an offensive or defamatory meaning, or may even induce infringement of intellectual property rights. The increasing number of cases that have been brought before courts all over the world puts forward questions on the conflict of fundamental freedoms of speech and access to information on the one hand, and personality rights of individuals— under a broader right of informational self-determination—on the other. In the light of the recent judgment of the Court of Justice of the European Union (EU) in Google Spain v AEPD, this article concludes that many requests for removal of suggestions including private individuals’ information will be successful on the basis of EU data protection law, even absent prejudice to the person concerned.
Resumo:
The purpose of this article is to discuss the relations between regulation, competition policy and consumer protection these relations in three key sectors of Brazil’s infrastructure: telecommunications, electricity and water supply. A study of the literature points to two general principles. First, the need for consumer protection depends on the “degree of sovereignty” enjoyed by consumers, defined in terms of the cost of consumer organization, consumers’ ability to evaluate services, and the level of competition in each sector. Second, the less sovereignty consumers enjoy the more consumer protection institutions are involved with regulation agencies. The evidence for the Brazilian case apparently corroborates these points. In addition, it is important to stress that consumer complaints in regulated sectors seem to have increased more intensely than in others. The article is divided into three sections. Section 1 presents theoretical elements and aspects of the relations between regulation, competition policy and consumer protection evidenced by international experience. Section 2 analyzes the Brazilian experience and in particular the available statistics on consumer complaints about telecommunications, electricity and water supply, submitted to Fundação Procon-SP during the nineties. The last section points to possible configurations of the institutional relations between competition policy, regulation and consumer protection, showing how the existing configuration of these areas in the three infrastructure sectors discussed confirms that the theoretical framework proposed has reasonable predictive power.
Resumo:
Best corporate governance practices published in the primers of Brazilian Securities and Exchange Commission and the Brazilian Corporate Governance Institute promote board independence as much as possible, as a way to increase the effectiveness of governance mechanism (Sanzovo, 2010). Therefore, this paper aims at understanding if what the managerial literature portraits as being self-evident - stricter governance, better performance - can be observed in actual evidence. The question answered is: do companies with a stricter control and monitoring system perform better than others? The method applied in this paper consists on comparing 116 companies in respect to the their independence level between top management team and board directors– being that measured by four parameters, namely, the percentage of independent outsiders in the board, the separation of CEO and chairman, the adoption of contingent compensation and the percentage of institutional investors in the ownership structure – and their financial return measured in terms return on assets (ROA) from the latest Quarterly Earnings release of 2012. From the 534 companies listed in the Stock Exchange of Sao Paulo – Bovespa – 116 were selected due to their level of corporate governance. The title “Novo Mercado” refers to the superior level of governance level within companies listed in Bovespa, as they have to follow specific criteria to assure shareholders ´protection (BM&F, 2011). Regression analyses were conducted in order to reveal the correlation level between two selected variables. The results from the regression analysis were the following: the correlation between each parameter and ROA was 10.26%; the second regression analysis conducted measured the correlation between the independence level of top management team vis-à-vis board directors – namely, CEO relative power - and ROA, leading to a multiple R of 5.45%. Understanding that the scale is a simplification of the reality, the second part of the analysis transforms all the four parameters into dummy variables, excluding what could be called as an arbitrary scale. The ultimate result from this paper led to a multiple R of 28.44%, which implies that the combination of the variables are still not enough to translate the complex reality of organizations. Nonetheless, an important finding can be taken from this paper: two variables (percentage of outside directors and percentage of institutional investor ownership) are significant in the regression, with p-value lower than 10% and with negative coefficients. In other words, counter affirming what the literature very often portraits as being self-evident – stricter governance leads to higher performance – this paper has provided evidences to believe that the increase in the formal governance structure trough outside directors in the board and ownership by institutional investor might actually lead to worse performance. The section limitations and suggestions for future researches presents some reasons explaining why, although supported by strong theoretical background, this paper faced some challenging methodological assumptions, precluding categorical statements about the level of governance – measured by four selected parameters – and the financial return in terms of financial on assets.
Resumo:
This dissertation investigates how credit institutions’ market power limits the effects of creditor protection rules on the interest rate and the spread of bank loans. We use the Brazilian Bankruptcy Reform of June/2005 (BBR) as a legal event affecting the institutional environment of the Brazilian credit market. The law augments creditor protection and aims to improve the access of firms to the credit market and to reduce the cost of borrowing. Either access to credit or the credit cost are also determined by bank industry competition and the market power of suppliers of credit. We derive a simple economic model to study the effect of market power interacting with cost of lending. Using an accounting and operations dataset from July/2004 to December/2007 provided by the Brazilian Central Bank, we estimate that the lack of competition in the bank lending industry hinders the potential reducing effect of the BBR on the interest rate of corporate loans by approximately 30% and on the spread by approximately 23%. We also find no statistical evidence that the BBR affected the concentration level of the Brazilian credit market. We present a brief report on bankruptcy reforms around the world, the changes in the Brazilian legislation and on some recent related articles in our introductory chapter. The second chapter presents the economic model and the testable hypothesis on how the lack of competition in the lending market limits the effects of improved creditor protection. In this chapter, we introduce our empirical strategy using a differences-in-differences model and we estimate the limiting effect of market power on the BBR’s potential to reduce interest rates and on the spread of bank loans. We use the BBR as an exogenous event that affects collateralized corporate loans (treatment group) but that does not affect clean consumer loans (control group) to identify these effects, using different concentration measures. In Chapter 3, we propose a two-stage empirical strategy to handle the H–Statistics proposed by Panzar and Rosse as a measure of market competition. We estimate the limiting effects of the lack of competition in replacing the concentration statistics by the H–Statistics. Chapter 4 presents a structural break test of the concentration index and checks if the BBR affects the dynamic evolution of the concentration index.
Resumo:
This work aims to predict the total maximum demand of a transformer that will be used in power systems to attend a Multiple Unit Consumption (MUC) in design. In 1987, COSERN noted that calculation of maximum total demand for a building should be different from that which defines the scaling of the input protection extension in order to not overestimate the power of the transformer. Since then there have been many changes, both in consumption habits of the population, as in electrical appliances, so that this work will endeavor to improve the estimation of peak demand. For the survey, data were collected for identification and electrical projects in different MUCs located in Natal. In some of them, measurements were made of demand for 7 consecutive days and adjusted for an integration interval of 30 minutes. The estimation of the maximum demand was made through mathematical models that calculate the desired response from a set of information previously known of MUCs. The models tested were simple linear regressions, multiple linear regressions and artificial neural networks. The various calculated results over the study were compared, and ultimately, the best answer found was put into comparison with the previously proposed model
Resumo:
This paper proposes the application of computational intelligence techniques to assist complex problems concerning lightning in transformers. In order to estimate the currents related to lightning in a transformer, a neural tool is presented. ATP has generated the training vectors. The input variables used in Artificial Neural Networks (ANN) were the wave front time, the wave tail time, the voltage variation rate and the output variable is the maximum current in the secondary of the transformer. These parameters can define the behavior and severity of lightning. Based on these concepts and from the results obtained, it can be verified that the overvoltages at the secondary of transformer are also affected by the discharge waveform in a similar way to the primary side. By using the tool developed, the high voltage process in the distribution transformers can be mapped and estimated with more precision aiding the transformer project process, minimizing empirics and evaluation errors, and contributing to minimize the failure rate of transformers. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The conventional Newton and fast decoupled power flow methods are considered inadequate for obtaining the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. At this point, the Jacobian matrix of the Newton method becomes singular. In addition, it is widely accepted that the P-V and Q-theta decoupling assumptions made for the fast decoupled power flow formulation no longer hold. However, in this paper, it is presented a new fast decoupled power flow that becomes adequate for the computation of the maximum loading point by simply using the reactive power injection of a selected PV bus as a continuation parameter. Besides, fast decoupled methods using V and 0 as parameters and a secant predictor are also presented. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained for the IEEE systems (14 and 118 buses) show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged.
Resumo:
This work proposes a methodology to generalize the Y-connections for 12- and 18-pulse autotransformers. A single mathematical expression, obtained through simple trigonometric operations, represents all the connections. The proposed methodology allows choosing any ratio between the input and the output voltages. The converters can operate either as step-up or as step-down voltage. To simplify the design of the windings, graphics are generated to calculate the turn-ratio and the polarity of each secondary winding, with respect to the primary winding. A design example, followed by digital simulations, illustrates the presented steps. Experimental results of two prototypes (12 and 18 pulses) are presented. The results also show that high power factor is an inherent characteristic of multi-pulse converters, without any active or passive power factor pre-regulators needs. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work proposes a methodology to generalize the A-connections for 12 and 18-pulse autotransformers. A single mathematical expression, obtained through simple trigonometric operations, represents all the connections. The proposed methodology allows choosing any ratio between the input and the output voltages. The converters can operate either as step-up or as step-down voltage. To simplify the design of the windings, graphics are generated to calculate the turn-ratio and the polarity of each secondary winding, with respect to the primary winding. A design example, followed by digital simulations, and experimental results illustrate the presented steps. The results also show that high power factor is an inherent characteristic of multi-pulse converters, without any active or passive power factor pre-regulators needs.