838 resultados para Corrective measures
Resumo:
Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor
Resumo:
Pectus excavatum is the most common deformity of the thorax. Pre-operative diagnosis usually includes Computed Tomography (CT) to successfully employ a thoracic prosthesis for anterior chest wall remodeling. Aiming at the elimination of radiation exposure, this paper presents a novel methodology for the replacement of CT by a 3D laser scanner (radiation-free) for prosthesis modeling. The complete elimination of CT is based on an accurate determination of ribs position and prosthesis placement region through skin surface points. The developed solution resorts to a normalized and combined outcome of an artificial neural network (ANN) set. Each ANN model was trained with data vectors from 165 male patients and using soft tissue thicknesses (STT) comprising information from the skin and rib cage (automatically determined by image processing algorithms). Tests revealed that ribs position for prosthesis placement and modeling can be estimated with an average error of 5.0 ± 3.6 mm. One also showed that the ANN performance can be improved by introducing a manually determined initial STT value in the ANN normalization procedure (average error of 2.82 ± 0.76 mm). Such error range is well below current prosthesis manual modeling (approximately 11 mm), which can provide a valuable and radiation-free procedure for prosthesis personalization.
Resumo:
Pectus excavatum is the most common deformity of the thorax. Pre-operative diagnosis usually includes Computed Tomography (CT) to successfully employ a thoracic prosthesis for anterior chest wall remodeling. Aiming at the elimination of radiation exposure, this paper presents a novel methodology for the replacement of CT by a 3D laser scanner (radiation-free) for prosthesis modeling. The complete elimination of CT is based on an accurate determination of ribs position and prosthesis placement region through skin surface points. The developed solution resorts to a normalized and combined outcome of an artificial neural network (ANN) set. Each ANN model was trained with data vectors from 165 male patients and using soft tissue thicknesses (STT) comprising information from the skin and rib cage (automatically determined by image processing algorithms). Tests revealed that ribs position for prosthesis placement and modeling can be estimated with an average error of 5.0 ± 3.6 mm. One also showed that the ANN performance can be improved by introducing a manually determined initial STT value in the ANN normalization procedure (average error of 2.82 ± 0.76 mm). Such error range is well below current prosthesis manual modeling (approximately 11 mm), which can provide a valuable and radiation-free procedure for prosthesis personalization.
Resumo:
Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor.
Resumo:
Pectus excavatum is the most common deformity of the thorax and usually comprises Computed Tomography (CT) examination for pre-operative diagnosis. Aiming at the elimination of the high amounts of CT radiation exposure, this work presents a new methodology for the replacement of CT by a laser scanner (radiation-free) in the treatment of pectus excavatum using personally modeled prosthesis. The complete elimination of CT involves the determination of ribs external outline, at the maximum sternum depression point for prosthesis placement, based on chest wall skin surface information, acquired by a laser scanner. The developed solution resorts to artificial neural networks trained with data vectors from 165 patients. Scaled Conjugate Gradient, Levenberg-Marquardt, Resilient Back propagation and One Step Secant gradient learning algorithms were used. The training procedure was performed using the soft tissue thicknesses, determined using image processing techniques that automatically segment the skin and rib cage. The developed solution was then used to determine the ribs outline in data from 20 patient scanners. Tests revealed that ribs position can be estimated with an average error of about 6.82±5.7 mm for the left and right side of the patient. Such an error range is well below current prosthesis manual modeling (11.7±4.01 mm) even without CT imagiology, indicating a considerable step forward towards CT replacement by a 3D scanner for prosthesis personalization.
Resumo:
Work-related musculoskeletal disorders (WMSDs) are among the most costly health problems that society is facing today. Prevention involves investments and it is important for organizations to make a cost ebenefit analysis of ergonomic projects. Return on prevention is a recent concern in the domain of occupational safety and health (OSH). There are many studies concerning the return on the prevention of WMSDs, in terms of the benefits for the organization in which the preventive measures are implemented. However, it is also important to perform an analysis of the impact of each measure on society (externalities). A model to perform a financial and economic costebenefit analysis related to OSH projects was developed and it was applied in the case of the prevention of WMSDs in a Portuguese hospital. An analysis of the accidents and corresponding costs has been made in six of the services of the hospital. Financial and an economic costebenefit analysis have been made and the benefitecost ratio (B/C) has been calculated. While the B/C financial ratio, considering only the benefits to the hospital, is around 2, the economic B/C ratio, taking into account all the external benefits that have been quantified, is higher than 14. Relevance to industry: Both the economic and the financial B/C ratio are important support tools for decision makers in public and private organizations, helping them to define which preventive measures should be implemented, taking into account the costs involved and the resulting quantified benefits, for the organization, for the workers and for the society.
Resumo:
BACKGROUND: When an organization performs an integrated analysis of risks through its Occupational Health and Safety Management System, several steps are suggested to address the implications of the identified risks. Namely, the organization should make a detailed analysis of the monetary impact for the organization of each of the preventive measures considered. However, it is also important to perform an analysis of the impact of each measure on society (externalities). OBJECTIVE: The aim of this paper is to present a case study related to the application of the proposed economic evaluation methodology. METHODS: An analysis of the work accidents in a hospital has been made. Three of the major types of accidents have been selected: needle stings, falls and excessive strain. Following the risk assessment, some preventive measures have been designed. Subsequently, the Benefit/Cost ratio (B/C) of these measures has been calculated, both in financial terms (from the organization’s perspective) and in economic terms (including the benefits for the worker and for the Society). RESULTS: While the financial ratio is only advantageous in some cases, when the externalities are taken into account, the B/C ratio increases significantly. CONCLUSIONS: It is important to consider external benefits to make decisions concerning the implementation of preventive measures in Occupational Health and Safety projects
Resumo:
There are many circumstances in which the effectiveness of preventive measures depends to a large extent on the compliance of the patient in changing his or her behavior or lifestyle. It is shown how economic techniques can be used (i) to describe the rationale of individuals and predict their behavior (Section 2); and (ii) to assess preventive measures that, by requiring a change of conduct, imply "costs" to the individual due to a decline in the quality of life (Appendix). Cigarette smoking and coronary heart disease are used as an illustration. While the analysis of Section 2 uses graphical techniques, a simple textbook-type of lifetime utility model with a mathematical emphasis is used in the Appendix. It is also shown that techniques often used to assess health care programs such as the QALYs (Quality-Adjusted Life Years) are inappropriate to the evaluation of preventive programs aiming at behavioral changes. Finally, topics that call for further research are indicated.
Resumo:
We have studied, in particular under normality of the implied random variables, the connections between different measures of risk such as the standard deviation, the W-ruin probability and the p-V@R. We discuss conditions granting the equivalence of these measures with respect to risk preference relations and the equivalence of dominance and efficiency of risk-reward criteria involving these measures. Then more specifically we applied these concepts to rigorously face the problem of finding the efficient set of de Finetti’s variable quota share proportional reinsurance.
Resumo:
Background: Poor nutritional status and worse health-related quality of life (QoL) have been reported in haemodialysis (HD) patients. The utilization of generic and disease specific QoL questionnaires in the same population may provide a better understanding of the significance of nutrition in QoL dimensions. Objective: To assess nutritional status by easy to use parameters and to evaluate the potential relationship with QoL measured by generic and disease specific questionnaires. Methods: Nutritional status was assessed by subjective global assessment adapted to renal patients (SGA), body mass index (BMI), nutritional intake and appetite. QoL was assessed by the generic EuroQoL and disease specific Kidney Disease Quality of Life-Short Form (KDQoL-SF) questionnaires. Results: The study comprised 130 patients of both genders, mean age 62.7 ± 14.7 years. The prevalence of undernutrition ranged from 3.1% by BMI ≤ 18.5 kg/m2 to 75.4% for patients below energy and protein intake recommendations. With the exception of BMI classification, undernourished patients had worse scores in nearly all QoL dimensions (EuroQoL and KDQoL-SF), a pattern which was dominantly maintained when adjusted for demographics and disease-related variables. Overweight/obese patients (BMI ≥ 25) also had worse scores in some QoL dimensions, but after adjustment the pattern was maintained only in the symptoms and problems dimension of KDQoL-SF (p = 0.011). Conclusion: Our study reveals that even in mildly undernourished HD patients, nutritional status has a significant impact in several QoL dimensions. The questionnaires used provided different, almost complementary perspectives, yet for daily practice EuroQoL is simpler. Assuring a good nutritional status, may positively influence QoL.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright 2013 Springer Netherlands.
Resumo:
Mestrado em Engenharia Química
Resumo:
This article is is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. Attribution-NonCommercial (CC BY-NC) license lets others remix, tweak, and build upon work non-commercially, and although the new works must also acknowledge & be non-commercial.
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ciências da Educação