914 resultados para Concurrent exception handling


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concurrent Engineering demands a new way of working and many organisations experience difficulty during implementation. The research described in this paper has the aim to develop a paper-based workbook style methodology that companies can use to increase the benefits generated by Concurrent Engineering, while reducing implementation costs, risk and time. The three-stage methodology provides guidance based on knowledge accumulated from implementation experience and best practitioners. It encourages companies to learn to manage their Concurrent Engineering implementation by taking actions which expose them to new and valuable experiences. This helps to continuously improve understanding of how to maximise the benefits from Concurrent Engineering. The methodology is particularly designed to cater for organisational and contextual uniqueness, as Concurrent Engineering implementations will vary from company to company. Using key actions which improve the Concurrent Engineering implementation process, individual companies can develop their own 'best practice' for product development. The methodology ensures that key implementation issues, which are primarily human and organisational, are addressed using simple but proven techniques. This paper describes the key issues that the majority of companies face when implementing Concurrent Engineering. The structure of the methodology is described to show how the issues are addressed and resolved. The key actions used to improve the Concurrent Engineering implementation process are explained and their inclusion in the implementation methodology described. Relevance to industry. Implementation of Concurrent Engineering concepts in manufacturing industry has not been a straightforward process. This paper describes a workbook-style tool that manufacturing companies can use to accelerate and improve their Concurrent Engineering implementation. © 1995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We captured free-ranging male Yangtze finless porpoises over three seasons and assayed leukocytes and serum biochemistry to investigate physiological responses to the capture and handlings. Serum thyroid hormones (THs) declined sharply in those porpoises compared with hormone variation in a captive male finless porpoise. Hypernatremia and hypokalemia were also significant in the free-ranging animals suggesting that conservation of serum sodium might be acutely vital for this freshwater subspecies. The animals captured in spring showed more significant neutrophilia and eosinopenia than those captured in autumn suggesting that they may be more affected by capture during the breeding season. Furthermore, physical examination of porpoises when out of the water was apparently stressful, particularly when they were kept out of the water for longer periods. However, an increase in circulating THs may be an adaptive response to accommodate these short-term stresses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemistry-based detection methods hold great potential towards development of hand-held nucleic-acid analyses instruments. In this work, we demonstrate the implementation of in situ electrochemical (EC) detection method in a microfluidic flow-through EC-qPCR (FTEC-qPCR) device, where both the amplification of the target nucleic-acid sequence and subsequent EC detection of the PCR amplicon are realized simultaneously at selected PCR cycles in the same device. The FTEC-qPCR device utilizes methylene blue (MB), an electroactive DNA intercalator, for electrochemical signal measurements in the presence of PCR reagent components. Our EC detection method is advantageous, when compared to other existing EC methods for PCR amplicon analysis, since FTEC-qPCR does not require probe-modified electrodes, or asymmetric PCR, or solid-phase PCR. Key technical issues related to surface passivation, electrochemical measurement, PCR inhibition by metal electrode, bubble-free PCR, were investigated. By controlling the concentration of MB and the exposure of PCR mixture to the bare metal electrode, we successfully demonstrated electrochemical measurement of MB in solution-phase, symmetric PCR by amplifying a fragment of lambda phage DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report addresses the problem of fault tolerance to system failures for database systems that are to run on highly concurrent computers. It assumes that, in general, an application may have a wide distribution in the lifetimes of its transactions. Logging remains the method of choice for ensuring fault tolerance. Generational garbage collection techniques manage the limited disk space reserved for log information; this technique does not require periodic checkpoints and is well suited for applications with a broad range of transaction lifetimes. An arbitrarily large collection of parallel log streams provide the necessary disk bandwidth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

N.W. Hardy and M.H. Lee. The effect of the product cost factor on error handling in industrial robots. In Maria Gini, editor, Detecting and Resolving Errors in Manufacturing Systems. Papers from the 1994 AAAI Spring Symposium Series, pages 59-64, Menlo Park, CA, March 1994. The AAAI Press. Technical Report SS-94-04, ISBN 0-929280-60-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada à Universidade Fernando Pessoa como parte dos requisitos para a obtenção do grau de Mestre em Psicologia, ramo de Psicologia Clínica e da Saúde

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hazard perception has been found to correlate with crash involvement, and has thus been suggested as the most likely source of any skill gap between novice and experienced drivers. The most commonly used method for measuring hazard perception is to evaluate the perception-reaction time to filmed traffic events. It can be argued that this method lacks ecological validity and may be of limited value in predicting the actions drivers’ will take to hazards encountered. The first two studies of this thesis compare novice and experienced drivers’ performance on a hazard detection test, requiring discrete button press responses, with their behaviour in a more dynamic driving environment, requiring hazard handling ability. Results indicate that the hazard handling test is more successful at identifying experience-related differences in response time to hazards. Hazard detection test scores were strongly related to performance on a driver theory test, implying that traditional hazard perception tests may be focusing more on declarative knowledge of driving than on the procedural knowledge required to successfully avoid hazards while driving. One in five Irish drivers crash within a year of passing their driving test. This suggests that the current driver training system does not fully prepare drivers for the dangers they will encounter. Thus, the third and fourth studies in this thesis focus on the development of two simulator-based training regimes. In the third study participants receive intensive training on the molar elements of driving i.e. speed and distance evaluation. The fourth study focuses on training higher order situation awareness skills, including perception, comprehension and projection. Results indicate significant improvement in aspects of speed, distance and situation awareness across training days. However, neither training programme leads to significant improvements in hazard handling performance, highlighting the difficulties of applying learning to situations not previously encountered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contribution of buildings towards total worldwide energy consumption in developed countries is between 20% and 40%. Heating Ventilation and Air Conditioning (HVAC), and more specifically Air Handling Units (AHUs) energy consumption accounts on average for 40% of a typical medical device manufacturing or pharmaceutical facility’s energy consumption. Studies have indicated that 20 – 30% energy savings are achievable by recommissioning HVAC systems, and more specifically AHU operations, to rectify faulty operation. Automated Fault Detection and Diagnosis (AFDD) is a process concerned with potentially partially or fully automating the commissioning process through the detection of faults. An expert system is a knowledge-based system, which employs Artificial Intelligence (AI) methods to replicate the knowledge of a human subject matter expert, in a particular field, such as engineering, medicine, finance and marketing, to name a few. This thesis details the research and development work undertaken in the development and testing of a new AFDD expert system for AHUs which can be installed in minimal set up time on a large cross section of AHU types in a building management system vendor neutral manner. Both simulated and extensive field testing was undertaken against a widely available and industry known expert set of rules known as the Air Handling Unit Performance Assessment Rules (APAR) (and a later more developed version known as APAR_extended) in order to prove its effectiveness. Specifically, in tests against a dataset of 52 simulated faults, this new AFDD expert system identified all 52 derived issues whereas the APAR ruleset identified just 10. In tests using actual field data from 5 operating AHUs in 4 manufacturing facilities, the newly developed AFDD expert system for AHUs was shown to identify four individual fault case categories that the APAR method did not, as well as showing improvements made in the area of fault diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to investigate the effects of cytochalasin B (20 μM) on the uptake of 3-O-[(14)C]-methyl-D-glucose or D-[U-(14)C]glucose (8.3 mM each) by BRIN-BD11 cells. Taking into account the distribution space of tritiated water ((3)HOH), which was unexpectedly increased shortly after exposure of the cells to cytochalasin B and then progressively returned to its control values, and that of L-[1-(14)C]glucose, used as an extracellular marker, it was demonstrated that cytochalasin B caused a modest, but significant inhibition of the uptake of D-glucose and its non-metabolized analog by the BRIN-BD11 cells. These findings resemble those observed in acinar or ductal cells of the rat submaxillary gland and displayed a relative magnitude comparable to that found for the inhibition of D-glucose metabolism by cytochalasin B in purified pancreatic islet B cells. These findings reinforce the view that the primary site of action of cytochalasin B is located at the level of the plasma membrane.