860 resultados para Carga pontual
Resumo:
In recent decades, the search for quality care has been widely discussed by the institutions and health professionals. In this context, it is the nurse coordinator of the process of providing nursing staff, reflecting the commitment to quality of care. In this process, it is the appearance of Infections Related to health care and its potential association with the workload in nursing as a valuable indicator of quality of care. Thus, this research contributes to studies to characterize the demand of nursing work to promote a safe healthcare practice. This study aimed to identify the association of nursing workload with the number of cases of Ventilator-Associated Pneumonia, urinary tract infection and central venous catheter infection in the intensive care unit. This is a quantitative research approach, descriptive, cross-sectional and prospective, held at Unimed Hospital in Natal-RN. The study population consisted of all patients treated in the Intensive Care Unit, Hospital for a period of 90 consecutive days in 2011. The convenience sample was compostapelos patients admitted to the ICU during the period of data collection, a total sample of 286 patients. To perform the data analysis software were used: Statistica 6.0, SPPS (Statistical Package for Social Sciences) version 17.0 (2004) and Excel 2007. In the descriptive analysis, we used Measures of Central Tendency and Measures of Dispersion or Variability and the use of nonparametric tests. Of the 286 patients, 88 were from the ICU and 198 ICU II II. Males predominated in the ICU I (51.1%) and female ICU II (57.6%) patients in the ICU I were aged 61-80 years (39.8%) followed by greater than 80 years (39.8%). In the ICU II, most of the patients were aged 61-80 years (38.9%) and then from 41 to 60 years (24.2%). In relation to the class of TISS inlet predominant class II in the two ICUs (59.1%), followed by Class III also in the two units (34.6%). Most patients (70.6%) out of the ICUs belonging to class II TISS. In the ICU I, the average number of forms of the TISS 28 was 6, has in ICU II this value drops to 3.2 forms. The overall mean was 19.9 TISS points in ICU patients I and ICU II.the 17 points in the average hours required to provide adequate nursing care to patients in the ICU I found that is 10 , 7 hours, and the ICU II 9.2 hours. It was found that the time provided by the nursing staff were higher in ICU II, with an average of 19 hours available for nurses in this sector. In the ICU I, which showed higher need of available hours, it was found that the mean value of 12.7 available hours. It was found that only 2.4% of patients had these units Ventilator-Associated Pneumonia, 1.0% were infected central venous catheter and 1.4% of patients had urinary tract infection. Infection associated with health care occurs, on average, on the tenth day of hospitalization. In the ICU II, this average value extends to the twelfth day with an excess of 2.7 hours of nursing care while in ICU I value decays to the ninth day of hospitalization with a deficiency of 12-hour assistance. It is concluded that patients generally showed a need for classification of semi-intensive care and has been assisted in their need to load. As for his association with the Related Infections Health will assist this analysis could not be performed due to the small number of notifications in this period. It is suggested further study how other factors related to infections me a longer period of analysis
Resumo:
This work presents results of field and laboratory tests using a Dynamic Cone Penetrometer, DCP. The tests were performed in order to evaluate the use of the equipment in sand for the control of bearing capacity of shallow foundations and fill compaction. For shallow foundations, the laboratory tests were conducted on sand placed in a metallic mould by the method of sand pluviation. Although the results show the inability to reproduce field conditions in the laboratory it was possible to verify the ability of the DCP to identify less resistant soil layers. The DCP tests for the analysis of compaction control were performed in a strong box with inside dimensions of 1,40 m x 1,40 m and 0,70 m in height. The soil layers were compacted with different densities though the use of a vibrating plate in order to obtain correlations between penetration index, DPI, and soil relative density. Other tests were also conducted to assess the influence of soil moisture on tests results. Among other findings, the results showed the great potential for the use of DCP to control the compaction of sand fills
Resumo:
An experimental study has been conducted to investigate the behavior of continuous flight auger (cfa) bored piles and metalic driven H-section piles under lateral loading in cohesionless soils. The piles were tested in two different areas at the same site. Both areas consisted of a 3-m thick compacted superficial fill of pure fine sand, underlain by layers of naturally occurring pure fine-thick sand. Fills are differentiated by the relative densities which were compressed, 45% e 70%, respectively. Each area received one identical pair of cfa piles and two identical pairs of H-piles. A static lateral loading test was performed in each pair of piles. In this work, the pile load test results are reported and interpreted. The horizontal coefficient of subgrade reaction was determined from the results of the loading tests and compared with values determined by correlations based on penetration resistance index of SPT tests (NSPT). p-y formulations describing the static behavior of the piles were applied to the problem under evaluation. Back Analyses were made through theoretical and experimental p-y curves for obtaining input parameters for the analytic models, among which the coefficient of horizontal reaction. The soil pile system horizontal loading at rupture was determined by the theoretical methods and the results were compared with the experimental results, checking its validity
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The objective of the present work is develop a model to simulate electrical energy networks in transient and stead states, using the software ATP (Alternative Transient Program), able to be a way to join two distinct themes, present in classical methodology planning networks: short circuit analysis and load flow theory. Beyond that, using a tool for relay simulation, this paper intend to use the new developed model to investigate the influence of transient phenomenon in operation of protection relays, and calibrate the enterprise's protections relays. For testing the model, some relays, actually, installed at COSERN were used
Resumo:
This work has as main objective to show all the particularities regarding the Three-phase Power Summation Method, used for load flow calculation, in what it says respect to the influence of the magnetic coupling among the phases, as well as to the losses presented in all the existent transformers in the feeder to be analyzed. Besides, its application is detailed in the study of the short-circuits, that happen in the presence of high impedance values, which possess a problem, that is its difficult detection and consequent elimination on the part of common devices of protection. That happens due to the characteristic presented by the current of short¬ circuit, in being generally of the same order of greatness that the load currents. Results of simulations accomplished in several situations will be shown, objectifying a complete analysis of the behavior of the proposed method in several types of short-circuits. Confront of the results obtained by the method with results of another works will be presented to verify its effectiveness
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this study were conducted experimental procedures for determination of variation of the expandability of rigid polyurethane foam (PUR) from a natural oil polyol (NOP), specifically the Castor oil plant, Ricinus communis, pure and additions of the vermiculite in phase dispersed in different percentage within a range from 0% to 20%, mass replacement. From the information acquired, were defined the parameters for production of bodies of test, plates obtained through controlled expansion, with the final volume fixed. Initially, the plates were subjected to thermal performance tests and evaluated the temperature profiles, to later be extracted samples duly prepared in accordance with the conditions required for each test. Was proceeded then the measurement of the coefficient of thermal conductivity, volumetric capacity heat and thermal diffusivity. The findings values were compared with the results obtained in the tests of thermal performance, contributing to validation of the same. Ultimately, it was investigated the influence that changes in physical-chemical structure of the material had exerted on the variation of thermophysical quantities through gas pycnometry, scanning electron microscopy (SEM) combined with energy dispersive X-ray fluorescence spectroscopy (EDXRF), infrared spectroscopy using Fourier transform (FTIR), thermogravimetric analysis (TGA) and differential thermal analysis (DTA). Based on the results obtained was possible to demonstrate that all load percentage analyzed promoted an increase in the potential expansion (PE) of the resin. In production of the plates, the composites with density near at the free expansion presented high contraction during the cure, being the of higher density adopted as definitive standard. In the thermal performance tests, the heating and cooling curves of the different composites had presented symmetry and values very close for lines of the temperature. The results obtained for the thermophysical properties of composites, showed little difference in respect of pure foam. The percentage of open pores and irregularities in the morphology of the composites were proportionate to the increment of vermiculite. In the interaction between the matrix and dispersed phase, there were no chemical transformations in the region of interface and new compounds were not generated. The composites of PUR-NOP and vermiculite presented thermal insulating properties near the foam pure and percentage significantly less plastic in its composition, to the formulation with 10% of load
Resumo:
In the execution of civil engineering works, either by wasting during the coating of wall or demolition of gypsum walls, the generation of the gypsum waste involves serious environmental concerns. These concerns are increased by the high demand of this raw material in the sector and by the difficulties of proper disposal byproduct generated. In the search for alternatives to minimize this problem, many research works are being conducted, giving emphasis in using gypsum waste as fillers in composites materials in order to improve the acoustic, thermal and mechanical performances. Through empirical testing, it was observed that the crystallization water contained in the residue (CaSO4.2H2O) could act like primary agent in the expanding of the polyurethane foam. Considering that polyurethane produced from vegetable oils are biodegradable synthetic polymers and that are admittedly to represent an alternative to petrochemical synthetic polyurethane, this research consist an analysis of the thermal behavior of a composite whose matrix obtained from a resin derived from the expansive castor oil seed, with loads of 4%, 8%, 12% and 16% of gypsum waste replacing to the polyol prepolymer blend. Contributors to this analysis: a characterization of the raw material through analysis of spectroscopy by Fourier transform infrared (FTIR), chemical analysis by X-Ray Fluorescence (XRF) and mineralogical analysis by X Ray Diffraction (XRD), complemented by thermo gravimetric analysis (TGA). In order to evaluate the thermo physical properties and thermal behavior of the composites manufactured in die closed with expansion contained, were also carried tests to determine the percentage of open pore volume using a gas pycnometer, scanning electronic microscopy (SEM), in addition to testing of flammability and the resistance to contact with hot surfaces. Through the analysis of the results, it appears that it is possible to produce a new material, which few changes in their thermo physical properties and thermal performance, promotes significant changes and attractive to the environment
Resumo:
The growing demand in the use of composite materials necessitates a better understanding of its behavior related to many conditions of loading and service, as well as under several ways of connections involved in mechanisms of structural projects. Within these project conditions are highlighted the presence of geometrical discontinuities in the area of cross and longitudinal sections of structural elements and environmental conditions of work like UV radiation, moisture, heat, leading to a decrease in final mechanical response of the material. In this sense, this thesis aims to develop studies detailed (experimental and semi-empirical models) the effects caused by the presence of geometric discontinuity, more specifically, a central hole in the longitudinal section (with reduced cross section) and the influence of accelerated environmental aging on the mechanical properties and fracture mechanism of FGRP composite laminates under the action of uniaxial tensile loads. Studies on morphological behavior and structural degradation of composite laminates are performed by macroscopic and microscopic analysis of affected surfaces, in addition to evaluation by the Measurement technique for mass variation (TMVM). The accelerated environmental aging conditions are simulated by aging chamber. To study the simultaneous influence of aging/geometric discontinuity in the mechanical properties of composite laminates, a semiempirical model is proposed and called IE/FCPM Model. For the stress concentration due to the central hole, an analisys by failures criteria were performed by Average-Stress Criterion (ASC) and Point-Stress Criterion (PSC). Two polymeric composite laminates, manufactured industrially were studied: the first is only reinforced by short mats of fiberglass-E (LM) and the second where the reinforced by glass fiber/E comes in the form of bidirectional fabric (LT). In the conception configurations of laminates the anisotropy is crucial to the final mechanical response of the same. Finally, a comparative study of all parameters was performed for a better understanding of the results. How conclusive study, the characteristics of the final fracture of the laminate under all conditions that they were subjected, were analyzed. These analyzes were made at the macroscopic level (scanner) microscope (optical and scanning electron). At the end of the analyzes, it was observed that the degradation process occurs similarly for each composite researched, however, the LM composite compared to composite LT (configurations LT 0/90º and LT ±45º) proved to be more susceptible to loss of mechanical properties in both regarding with the central hole as well to accelerated environmental aging
Resumo:
The standardization of the bovine skin thickness in the leather industry generates a residue known as wet-blue . At the end of twentieth century, the brazilian industry discarded about 131 thousand tons of this residue in nature, provoking a great environmental liability. In this paper is presented the analyses of the termophysical properties, thermal and volumetric expansion performance of a composite of vegetable resin of castor oil plant (Ricinus communis) with load of industrial residue of leather "wet-blue", for application as thermal isolation material of warm surfaces. There were considered four percentile levels of residue load in the proportions in mass of 0%, 5%, 10% and 15%, added to the expansible resin of castor oil plant in two configurations: sawed leather and crushed leather in a smaller particle (powder) by grinding in a mill of balls. Twenty-one proof bodies were produced for termophysical properties analysis (three for each configuration) and four proof bodies for rehearsals of thermal acting. Analyses of thermal acting were done in test cameras. The results of the rehearsals were compared to those obtained considering the castor oil plant foam without residue addition. A small reduction of the thermal conductivity of the composite was observed in the proportion of 10% of leather residue in both configurations. Regarding thermal conductivity, calorific capacity and diffusivity, it was verified that the proposed composite showed very close values to the commercial insulating materials (glass wool, rock wool, EPS). It was still demonstrated the technical viability of the use of composite as insulating thermal for systems of low potency. The composite presented larger volumetric expansion with 15% of sawed residue of leather.
Resumo:
The use of composite materials and alternative is being increased every day, as it becomes more widespread awareness that the use of renewable and not harmful to the environment is part of a new environmentally friendly model. Since its waste (primarily fiberglass) can not be easily recycled by the difficulty that still exists in this process, since they have two phases mixed, a polymeric matrix thermoset difficult to recycle because it is infusible and phase of fiber reinforcements. Thermoset matrix composites like Polyester + fiberglass pose a threat due to excessive discharge. Aiming to minimize this problem, aimed to reuse the composite Polyester + fiber glass, through the wastes obtained by the grinding of knifes and balls. These residues were incorporated into the new composite Polyester/Fiberglass for hot compression mold and compared tribological to composites with filler CaCO3, generally used as filler, targeting a partial replacement of CaCO3 by such waste. The composites were characterized by thermal analysis (TGA, DSC and DMA), by the surface integrity (roughness determination, contact angle and surface energy), mechanical properties (hardness) and tribological tests (wear and coefficient of dynamic friction) in order to evaluate the effect of loads and characterize these materials for applications that can take, in the tribological point of view since waste Polyester + fiberglass has great potential for replacement of CaCO3
Resumo:
Space Science was built using a composite made of plaster, EPS, shredded tires, cement and water. Studies were conducted to thermal and mechanical resistance. Inside the mold EPS plates were placed in order to obtain a higher thermal resistance on the wall constructed, as well as to give it an end environmentally friendly in view of both the tire and the EPS occupy a large space in landfills and year need to be degraded when released into the environment. Compression tests were performed according to ABNT blocks to seal, measurements of the temperature variation in the external and internal walls using a laser thermometer and check the temperature of the indoor environment using a thermocouple attached to a digital thermometer. The experiments demonstrated the heat provided by the composite values from the temperature difference between the internal and external surfaces on the walls, reaching levels of 12.4 ° C and room temperature in the interior space of the Science of 33.3 ° C, remaining within the zone thermal comfort for hot climate countries. It was also demonstrated the proper mechanical strength of such a composite for sealing walls. The proposed use of the composite can contribute to reducing the extreme housing shortage in our country, producing popular homes at low cost and with little time to work
Resumo:
With a view to revitalizing public environments through criteria that include economy, tourism, aesthetics and respect for the environment, this paper proposes a model of kiosk manufactured with composite material blocks, to be employed as a public instrument. . The model consists of a structure composed of planned blocks and manufactured in cement-based composite, gypsum, ground and water, having the styrofoam inside filled with pet bottles of 500 ml dose. The social and environmental issue is the critical point of the work when it can, through the reuse of environmentally harmful materials such as polyethylene terephthalate PET, using such modules for the construction of various areas of Commerce, promoting the protection of the environment combined with the improvement of the quality of life of the population. The tourism factor, which is significant in the economy of the North, is also considered as the modulated kiosk has a visual aspect innovative and differentiated. The environmental issue is addressed by encouraging the reuse of PET material and EPS (polystyrene)
Resumo:
Introduction: The intrinsic gait disorders in individuals with Parkinson's disease (PD) are one of the most disabling motor symptoms. Among the therapeutic approaches used in attempts to improve the motor function, especially the gait pattern of individuals, stands out the treadmill gait training associated with the addition of load. However, there are few findings that elucidate the benefits arising from such practice. Objective: To assess the effects of adding load on the treadmill gait training in individuals with PD. Material and Methods: A controlled, randomized and blinded clinical trial, was performed with a sample of 27 individuals (18 men and 9 women) with PD, randomly assigned to three experimental conditions, namely: treadmill gait training (n=9), treadmill gait training associated with addition of 5% load (n=9) and treadmill gait training associated with addition of 10% load (n=9). All volunteers were assessed, during phase on of Parkinson's medication, regarding to demographic, clinical and anthropometric (identification form) data, level of disability (Hoehn and Yahr Modified Scale), cognitive function (Mini Mental State Examination), clinical functional - in those areas activity of daily living and motor examination (Unified Parkinson's Disease Rating Scale - UPDRS) and gait cinematic analysis was performed through Qualisys Motion Capture System®. The intervention protocol consisted of gait training in a period of 4 consecutive weeks, with three weekly sessions, lasting 30 minutes each. The post-intervention assessment occurred the next day after the last training session, which was performed cinematic analysis of gait and the UPDRS. Data analysis was performed using the software Statistical Package for Social Sciences® (SPSS) 17.0. Results: The age of volunteers ranged from 41 to 75 years old (62,26 ± 9,07) and the time of clinical diagnosis of PD between 2 to 9 years (4,56 ± 2,42). There was a reduction regarding the score from motor exam domain (p=0,005), only when training with the addition of a 5% load. As for the space-time variables there was no significant difference between groups (p>0,120); however, the training with addition of 5% load presented the following changes: increase in stride length (p=0,028), in step length (p=0,006), in time balance of the most affected member (p=0,006) and reduction in support time of the referred member (p=0,007). Regarding angular variables significant differences between groups submitted to treadmill gait training without addition load and with 5% of load were observed in angle of the ankle at initial contact (p=0,019), in plantar flexion at toe-off (p=0,003) and in the maximum dorsiflexion in swing (p=0,005). While within groups, there was a reduction in amplitude of motion of the ankle (p=0,048), the only workout on the treadmill. Conclusion: The treadmill gait training with addition of 5% load proved to be a better experimental condition than the others because it provided greater gains in a number of variables (space-time and angular gait) and in the motion function, becoming a therapy capable of effectively improving the progress of individuals with PD