1000 resultados para BIOLOGICAL MONITOR
Resumo:
ABSTRACT Pathogenic fungi cause skin darkening and peach quality depreciation in post harvest. Therefore, alternative techniques to chemical treatment are necessary in order to reduce risks to human health. The aim of this study was to evaluate the effect of the application of Trichoderma harzianum in association with different fungicides applied before harvest to 'Eldorado' peaches for brown rot control and other quality parameters during storage. The treatments consisted of five preharvest fungicide applications (control, captan, iprodione, iminoctadine and tebuconazole) associated with postharvest application of T. harzianum, after cold storage (with and without application), in three evaluation times (zero, two and four days at 20 °C), resulting in a 5x2x3 factorial design. The application of T. harzianum only brought benefits to the control of brown rot when combined with the fungicide captan, at zero day shelf life. After two days, there was a greater skin darkening in peaches treated with T. harzianum compared with peaches without the treatment, except for peaches treated with the fungicide iprodione and T. harzianum The application of T. harzianum during postharvest showed no benefits for the control of brown rot, however, the association with fungicides reduced the incidence of Rhizopus stolonifer during the shelf life.
Resumo:
Although a great body of literature exists concerning the ingestion of food contaminated with aflatoxin, there are still few studies regarding mycotoxin inhalation in occupational settings. Since mycotoxins are relatively non-volatile, inhalation exposure is cause by inhalation of airborne fungal particulates or fungi-contaminated substrates that contain aflatoxin. We intend to know if there is occupational exposure to aflatoxin in Portuguese poultry and swine production. A total of 19 individuals (11 swine; 8 poultry) agreed and provided blood samples during the course of this investigation. Measurement of AFB1 was performed by ELISA. The samples were treated with pronase (Merck), wash in a Column C18 and purification was made with immunoaffinity columns (R.biopharma), specific for AFB1. It was applied statistical test (Mann-Whitney) to verified statistical difference in AFB1 results between the two settings. Results varied with concentrations from
Resumo:
Introdução – No caso de uma eventual contaminação radioativa esta deve ser quantificada, pelo que é necessário garantir que as condições de funcionamento de um monitor de contaminação de superfícies se encontrem adequadamente caracterizadas, através da determinação da sua eficiência de deteção. Este estudo tem como objetivo determinar a eficiência de deteção de um monitor de contaminação e analisar a influência da distância e da atividade. Metodologia – O monitor de contaminação Thermo Mini 900E e as fontes radioativas planas de referência de Carbono – 14 (C-14), Césio – 137 (Cs-137), Estrôncio – 90 (Sr-90), Cloro – 36 (Cl-36) e Amerício – 241 (Am-241) com débito de emissão superficial rastreável ao Physikalish Technischen Bundesanstalt (PTB) foram utilizadas. Fontes de Sr-90 e C-14 com dois débitos de emissão distintos para cada e distâncias de 1 a 20mm foram usados para estudar a sua influência na eficiência de deteção. Resultados – Verificou-se que as fontes radioativas emissoras de partículas de maior energia apresentam uma maior eficiência de deteção e que esta diminui com o aumento da distância do detetor à fonte, sendo que os radioisótopos de maior energia apresentam um decréscimo na eficiência de 15% ao longo de 20mm, enquanto os radioisótopos de menor energia apresentam um decréscimo de 10%. Não se verificou uma influência expressiva do débito de emissão na eficiência de deteção deste monitor de contaminação. Conclusão – A eficiência de deteção de um monitor de contaminação portátil é dependente da distância deste à contaminação bem como do tipo de radiação emitida e energia dos radioisótopos presentes na contaminação. - ABSTRACT - Introduction – A radioactive contamination needs to be quantified in case it eventually occurs. Therefore it is necessary to ensure that the operating conditions of a surface contamination monitor are characterized by determining its detection efficiency. This experimental study aims to determine the detection efficiency of a contamination monitor and evaluate the distance and surface emission rate influence on the detection efficiency. Methodology – A contamination monitor Thermo Mini 900E was tested with reference radiation sources of Carbon – 14 (C-14), Cesium – 137 (Cs-137), Strontium – 90 (Sr-90), Chlorine – 36 (Cl-36) and Americium – 241 (Am-241) with its emission rate traced to the Physikalish Technischen Bundesanstalt (PTB). Sources of Sr-90 and C-14 with two different emission rates for each one and distances of 1 to 20mm were used to study its influence in the detection efficiency. Results – With the increasing of distance, the detection efficiency decreases. The most energetic radiation sources have higher detection efficiency, boasting a 15% decrease over 20mm whereas the sources bearing a smaller efficiency decrease 10%. No influence of the surface emission rate in the detection efficiency was verified. Conclusion – Thus, it is concluded that the detection efficiency of a contamination monitor is dependent of the distance between it and the contamination as well as the type and energy of the radioisotopes present in the contamination.
Resumo:
In the context of the design of working hours inequities in health associated with biological, psychological, social, and socioeconomic diversities can be observed. The paper first tries to set up a frame of reference for a discussion of this topic, relating to the Universal Declaration of Human Rights and some recent discussions on equity in health and then goes into some factors that produce inequities in health in the context of the design of working hours, dealing with sex or gender, age and job age, personality traits, marital status, social support, diversities in values, and socio-economic differences; the discussion deals with approaches on how to deal with these differences and inequities.
Resumo:
Visto que o tratamento das águas residuais é um tema muito importante para a saúde pública, é necessário criar vários processos para o tratamento de efluentes. Após a finalização de todos os processos, o efluente tratado terá de cumprir requisitos de qualidade químicos e biológicos para a sua descarga no meio ambiente. A utilização de equipamentos e técnicas, caraterizados por elevados níveis de precisão (como a tecnologia), é muito importante, pois é possível tornar o sistema mais autónomo, monitorizar processos e controlá-los de forma eficiente e acessível para o utilizador. Assim, neste tipo de sistemas terá que ser utilizado um elemento central de controlo e vários elementos auxiliares, nomeadamente vários tipos de sensores. Também terá que se usar uma interface que permita ao utilizador comunicar com o sistema de controlo, de forma a poder manipular e ajustar determinados parâmetros que influenciam os processos de tratamento. Neste sentido, a presente dissertação apresenta um estudo/projeto, na Adega Cooperativa de Mangualde, onde se pretende automatizar, controlar e monitorizar a Estação de Tratamento de Águas Residuais (ETAR) da mesma. Como, cada vez mais, os lucros das empresas dependem do bom funcionamento, não só dos trabalhadores mas também dos seus equipamentos, é necessário que estes estejam em ótimas condições de trabalho, de forma a evitar avarias e paragens na produção, o que vem trazer, por consequência, prejuízos para as empresas. Assim, realizar-se-á, também, um plano de manutenção para garantir o bom desempenho dos equipamentos desta unidade fabril.
Resumo:
In recent years Ionic Liquids (ILs) are being applied in life sciences. ILs are being produce with active pharmaceutical drugs (API) as they can reduce polymorphism and drug solubility problems [1] Also ILs are being applied as a drug delivery device in innovative therapies What is appealing in ILs is the ILs building up platform, the counter-ion can be carefully chosen in order to avoid undesirable side effects or to give innovative therapies in which two active ions are paired. This work shows ILs based on ampicillin (an anti-bacterial agent) and ILs based on Amphotericin B. Also we show studies that indicate that ILs based on Ampicillin could reverse resistance in some bacteria. The ILs produced in this work were synthetized by the neutralization method described in Ferraz et. al. [2] Ampicillin anion was combined with the following organic cations 1-ethyl-3-methylimidazolium, [EMIM]; 1-hydroxy-ethyl-3-methylimidazolium, [C2OHMIM]; choline, [cholin]; tetraethylammonium, [TEA]; cetylpyridinium, [C16pyr] and trihexyltetradecylphosphonium, [P6,6,6,14]. Amphotericin B was combined with [C16pyr], [cholin] and 1-metohyethyl-3-methylimidazolium, [C3OMIM]. The ILs-APIs based on ampicillin[2] were tested against sensitive Gram-negative bacteria Escherichia coli ATCC 25922 and Klebsiella pneumonia (clinical isolated), as well as on Gram positive Staphylococcus Aureus ATCC 25923, Staphylococcus epidermidis and Enterococcus faecalis. The arising resistance developed by bacteria to antibiotics is a serious public health threat and needs new and urgent measures. We study the bacterial activity of these compounds against a panel of resistant bacteria (clinical isolated strains): E. coli CTX M9, E. coli TEM CTX M9, E. coli TEM1, E. coli CTX M2, E. coli AmpC Mox2. In this work we demonstrate that is possible to produce ILs from anti-bacterial and anti-fungal compounds. We show here that the new ILs can reverse the bacteria resistance. With the careful choice of the organic cation, it is possible to create important biological and physic-chemical properties. This work also shows that the ion-pair is fundamental in ampicillin mechanism of action.
Resumo:
3rd Portuguese Meeting on Medicinal Chemistry and 1st Portuguese-Spanish-Brazilian Meeting on Medicinal Chemistry, Aveiro, 28-30 Novembro 2012.
Resumo:
Anticancer activity of the new [Ru(eta(5)-C5H5)(PPh3)(Me(2)bpy)][CF3SO3] (Me(2)bpy = 4,4'-dimethyl-2,2'-bipyridine) complex was evaluated in vitro against several human cancer cell lines, namely A2780, A2780CisR, HT29, MCF7, MDAMB231 and PC3. Remarkably, the IC50 values, placed in the nanomolar and sub-micromolar range, largely exceeded the activity of cisplatin. Binding to human serum albumin, either HSA (human serum albumin) or HSA(faf) (fatty acid-free human serum albumin) does not affect the complex activity. Fluorescence studies revealed that the present ruthenium complex strongly quench the intrinsic fluorescence of albumin. Cell death by the [Ru(eta(5)-C5H5)(PPh3)(Me(2)bpy)][CF3SO3] complex was reduced in the presence of endocytosis modulators and at low temperature, suggesting an energy-dependent mechanism consistent with endocytosis. On the whole, the biological activity evaluated herein suggests that the complex could be a promising anticancer agent. (C) 2013 Elsevier Inc. All rights reserved.
Resumo:
New PVC membrane electrodes for the determination of sulfadiazine (SDZ) are presented. The electrodes are fabricated with conventional and tubular configurations with a graphite-based electrical contact, and no internal reference solution. The selective membranes consist of bis(triphenylphosphoranilidene)ammonium·SDZ (electrode A), tetraoctylammonium bromide (electrode B), or iron(II)-phthalocyanine (FePC) (electrode C) electroactive materials dispersed in a PVC matrix of o-nitrophenyl octyl ether (o-NPOE) plasticizer. The sensors A, B, and C displayed linear responses over the concentration ranges 1.0*10-2 – 1.0*10–5, 1.0*10–2 – 7.5*10–6, and 3.2*10–2 – 7.0* 10–6 mol l–1 (detection limits of 1.09, 2.04 and 0.87 mg ml–1) with anionic slopes of –57.3 ± 0.1, –46.7 ± 0.5, and –65.1 ± 0.2 mV decade–1, respectively. No effect from pH was observed within 4.0 – 5.5, 4.8 – 10, and 4.5 – 8, respectively, and good selectivity was found. The sensors were applied to the analysis of pharmaceuticals and biological fluids in steady state and in flow conditions.
Resumo:
New potentiometric membrane sensors with cylindrical configuration for tetracycline (TC) are described based on the use of a newly designed molecularly imprinted polymer (MIP) material consisting of 2-vinylpyridine as a functional monomer in a plasticized PVC membrane. The sensor exhibited significantly enhanced response towards TC over the concentration range 1.59 10 5–1.0 10 3 mol L 1 at pH 3–5 with a lower detection limit of 1.29 10 5 mol L 1. The response was near-Nernstian, with average slopes of 63.9 mV decade 1. The effect of lipophilic salts and various foreign common ions were tested and were found to be negligible. The possibility of applying the proposed sensor to TC determination in spiked biological fluid samples was demonstrated.
Resumo:
Radiotherapy (RT) is one of the most important approaches in the treatment of cancer and its performance can be improved in three different ways: through the optimization of the dose distribution, by the use of different irradiation techniques or through the study of radiobiological initiatives. The first is purely physical because is related to the physical dose distributiuon. The others are purely radiobiological because they increase the differential effect between the tumour and the health tissues. The Treatment Planning Systems (TPS) are used in RT to create dose distributions with the purpose to maximize the tumoral control and minimize the complications in the healthy tissues. The inverse planning uses dose optimization techniques that satisfy the criteria specified by the user, regarding the target and the organs at risk (OAR’s). The dose optimization is possible through the analysis of dose-volume histograms (DVH) and with the use of computed tomography, magnetic resonance and other digital image techniques.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Gestão e Sistemas Ambientais
Resumo:
OBJECTIVE To analyze the access and utilization profile of biological medications for psoriasis provided by the judicial system in Brazil.METHODSThis is a cross-sectional study. We interviewed a total of 203 patients with psoriasis who were on biological medications obtained by the judicial system of the State of Sao Paulo, from 2004 to 2010. Sociodemographics, medical, and political-administrative characteristics were complemented with data obtained from dispensation orders that included biological medications to treat psoriasis and the legal actions involved. The data was analyzed using an electronic data base and shown as simple variable frequencies. The prescriptions contained in the lawsuits were analyzed according to legal provisions.RESULTS A total of 190 lawsuits requesting several biological drugs (adalimumab, efalizumab, etanercept, and infliximab) were analyzed. Patients obtained these medications as a result of injunctions (59.5%) or without having ever demanded biological medication from any health institution (86.2%), i.e., public or private health services. They used the prerogative of free legal aid (72.6%), even though they were represented by private lawyers (91.1%) and treated in private facilities (69.5%). Most of the patients used a biological medication for more than 13 months (66.0%), and some patients were undergoing treatment with this medication when interviewed (44.9%). Approximately one third of the patients discontinued treatment due to worsening of their illness (26.6%), adverse drug reactions (20.5%), lack of efficacy, or because the doctor discontinued this medication (13.8%). None of the analyzed medical prescriptions matched the legal prescribing requirements. Clinical monitoring results showed that 70.3% of the patients had not undergone laboratory examinations (blood work, liver and kidney function tests) for treatment control purposes.CONCLUSIONS The plaintiffs resorted to legal action to get access to biological medications because they were either unaware or had difficulty in accessing them through institutional public health system procedures. Access by means of legal action facilitated long-term use of this type of medication through irregular prescriptions and led to a high rate of adverse drug reactions as well as inappropriate clinical monitoring.
Resumo:
[CoCl(-Cl)(Hpz(Ph))(3)](2) (1) and [CoCl2(Hpz(Ph))(4)] (2) were obtained by reaction of CoCl2 with HC(pz(Ph))(3) and Hpz(Ph), respectively (Hpz(Ph)=3-phenylpyrazole). The compounds were isolated as air-stable solids and fully characterized by IR and far-IR spectroscopy, MS(ESI+/-), elemental analysis, cyclic voltammetry (CV), controlled potential electrolysis, and single-crystal X-ray diffraction. Electrochemical studies showed that 1 and 2 undergo single-electron irreversible (CoCoIII)-Co-II oxidations and (CoCoI)-Co-II reductions at potentials measured by CV, which also allowed, in the case of dinuclear complex 1, the detection of electronic communication between the Co centers through the chloride bridging ligands. The electrochemical behavior of models of 1 and 2 were also investigated by density functional theory (DFT) methods, which indicated that the vertical oxidation of 1 and 2 (that before structural relaxation) affects mostly the chloride and pyrazolyl ligands, whereas adiabatic oxidation (that after the geometry relaxation) and reduction are mostly metal centered. Compounds 1 and 2 and, for comparative purposes, other related scorpionate and pyrazole cobalt complexes, exhibit catalytic activity for the peroxidative oxidation of cyclohexane to cyclohexanol and cyclohexanone under mild conditions (room temperature, aqueous H2O2). Insitu X-ray absorption spectroscopy studies indicated that the species derived from complexes 1 and 2 during the oxidation of cyclohexane (i.e., Ox-1 and Ox-2, respectively) are analogous and contain a Co-III site. Complex 2 showed low invitro cytotoxicity toward the HCT116 colorectal carcinoma and MCF7 breast adenocarcinoma cell lines.