934 resultados para Alton (Ill.)
Resumo:
This paper examines the implications of policy fracture and arms length governance within the decision making processes currently shaping curriculum design within the English education system. In particular it argues that an unresolved ‘ideological fracture’ at government level has been passed down to school leaders whose response to the dilemma is distorted by the target-driven agenda of arms length agencies. Drawing upon the findings of a large scale on-line survey of history teaching in English secondary schools, this paper illustrates the problems that occur when policy making is divorced from curriculum theory, and in particular from any consideration of the nature of knowledge. Drawing on the social realist theory of knowledge elaborated by Young (2008), we argue that the rapid spread of alternative curricular arrangements, implemented in the absence of an understanding of curriculum theory, undermines the value of disciplined thinking to the detriment of many young people, particularly those in areas of social and economic deprivation.
Resumo:
Optimal state estimation from given observations of a dynamical system by data assimilation is generally an ill-posed inverse problem. In order to solve the problem, a standard Tikhonov, or L2, regularization is used, based on certain statistical assumptions on the errors in the data. The regularization term constrains the estimate of the state to remain close to a prior estimate. In the presence of model error, this approach does not capture the initial state of the system accurately, as the initial state estimate is derived by minimizing the average error between the model predictions and the observations over a time window. Here we examine an alternative L1 regularization technique that has proved valuable in image processing. We show that for examples of flow with sharp fronts and shocks, the L1 regularization technique performs more accurately than standard L2 regularization.
Resumo:
We consider four-dimensional variational data assimilation (4DVar) and show that it can be interpreted as Tikhonov or L2-regularisation, a widely used method for solving ill-posed inverse problems. It is known from image restoration and geophysical problems that an alternative regularisation, namely L1-norm regularisation, recovers sharp edges better than L2-norm regularisation. We apply this idea to 4DVar for problems where shocks and model error are present and give two examples which show that L1-norm regularisation performs much better than the standard L2-norm regularisation in 4DVar.
Resumo:
In this paper we explore classification techniques for ill-posed problems. Two classes are linearly separable in some Hilbert space X if they can be separated by a hyperplane. We investigate stable separability, i.e. the case where we have a positive distance between two separating hyperplanes. When the data in the space Y is generated by a compact operator A applied to the system states ∈ X, we will show that in general we do not obtain stable separability in Y even if the problem in X is stably separable. In particular, we show this for the case where a nonlinear classification is generated from a non-convergent family of linear classes in X. We apply our results to the problem of quality control of fuel cells where we classify fuel cells according to their efficiency. We can potentially classify a fuel cell using either some external measured magnetic field or some internal current. However we cannot measure the current directly since we cannot access the fuel cell in operation. The first possibility is to apply discrimination techniques directly to the measured magnetic fields. The second approach first reconstructs currents and then carries out the classification on the current distributions. We show that both approaches need regularization and that the regularized classifications are not equivalent in general. Finally, we investigate a widely used linear classification algorithm Fisher's linear discriminant with respect to its ill-posedness when applied to data generated via a compact integral operator. We show that the method cannot stay stable when the number of measurement points becomes large.
Resumo:
P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.
Resumo:
Objectives: To examine whether denture use and recurrent sores caused by ill-fitting dentures are associated with intra-oral squamous cell carcinoma (IO-SCC) in individuals exposed to tobacco. Methods: We conducted a hospital-based case-control study. The study population comprised 124 patients with IO-SCC and the same number of controls (individually paired according to gender and age) recruited from outpatient units of the same hospital. Conditional logistic regression analysis assessed the effect of denture use and recurrent oral sores by ill-fitting dentures, adjusted by covariates on the lifetime exposure to alcohol and tobacco, socioeconomic standings, and dietary patterns. Results: The use of dentures showed no association with IO-SCC [adjusted odds ratio (OR) 1.40, 95 percent confidence interval 0.51-3.87, P = 0.513] in an assessment controlled by socioeconomic position, lifetime exposure to alcohol and tobacco, and dietary patterns. However, the report of recurrent sores caused by ill-fitting dentures showed significant association with the disease (adjusted OR 4.58, 95 percent confidence interval 1.52-13.76, P = 0.007). Conclusions: The association between recurrent oral sores caused by ill-fitting dentures and squamous cell carcinoma of the mouth in smokers is in agreement with the hypothesis that the chronic physical irritation of oral mucosa contributes to the topical carcinogenic effect of tobacco, which must be taken into careful consideration in the planning of dental services for adults and the elderly.
Resumo:
This paper traces the historical development in the State of Maine of the procedures by which persons found to be mentally unsound can be committed to institutional care against their will. Beginning in 1820 and continuing to the present, specific changes in the statutes governing this area are noted. Both the criminal and civil commitment procedures are dealt with. Following the historical trace, pending legislation relating to the criminal commitment process is examined in detail. Finally, consideration is given to the need for a complete reexamination of the practice of involuntary commitment involving ethical and constitutional issues.
Resumo:
This article describes analyzing Interlibrary Loan data to help inform collection management decision and offers guidance for formulating policies for discerning borrowed titles indicative of gaps in the library from special-interest pursuits beyond the scope of the university curriculum.
Resumo:
According to the World Health Organization (WHO) estimates for the year 2020, approximately 1.5 million people will commit suicide, and at least 10 times that many will make an attempt. This paper offers a brief overview of the current state of the epidemiology of suicide, a burgeoning public health problem. The information provided is based in large measure on reports of suicide mortality from 130/193 countries. In order to contextualize these data, this paper explores the contribution of both individual and sociocultural factors that influence suicidal behavior, from which much has been learned. Outlining the history of attempts by international and national organizations like WHO, United Nations, member states in the European community and other countries to regularize identification and suicide reporting procedures, this paper also demonstrates that serious knowledge gaps remain. Minimal requirements for successful evidence-based interventions are presented. (C) 2010 Published by Elsevier Masson SAS.
Resumo:
BACKGROUND: In spontaneously breathing cardiac patients, pulmonary artery pressure (PAP) can be accurately estimated from the transthoracic Doppler study of pulmonary artery and tricuspid regurgitation blood flows. In critically ill patients on mechanical ventilation for acute lung injury, the interposition of gas between the probe and the heart renders the transthoracic approach problematic. This study was aimed at determining whether the transesophageal approach could offer an alternative. METHODS: Fifty-one consecutive sedated and ventilated patients with severe hypoxemia (arterial oxygen tension/fraction of inspired oxygen < 300) were prospectively studied. Mean PAP measured from the pulmonary artery catheter was compared with several indices characterizing pulmonary artery blood flow assessed using transesophageal echocardiography: preejection time, acceleration time, ejection duration, preejection time on ejection duration ratio, and acceleration time on ejection duration ratio. In a subgroup of 20 patients, systolic PAP measured from the pulmonary artery catheter immediately before withdrawal was compared with Doppler study of regurgitation tricuspid flow performed immediately after pulmonary artery catheter withdrawal using either the transthoracic or the transesophageal approach. RESULTS: Weak and clinically irrelevant correlations were found between mean PAP and indices of pulmonary artery flow. A statistically significant and clinically relevant correlation was found between systolic PAP and regurgitation tricuspid flow. In 3 patients (14%), pulmonary artery pressure could not be assessed echocardiographically. CONCLUSIONS: In hypoxemic patients on mechanical ventilation, mean PAP cannot be reliably estimated from indices characterizing pulmonary artery blood flow. Systolic PAP can be estimated from regurgitation tricuspid flow using either transthoracic or transesophageal approach. © 2008 American Society of Anesthesiologists, Inc.
Resumo:
Objective: Characterizing the transport of critically ill patients in an adult intensive care unit.Methods: Cross-sectional study in which 459 intra -hospital transports of critically ill patients were included. Data were collected from clinical records of patients and from a form with the description of the materials and equipment necessary for the procedure, description of adverse events and of the transport team.Results: A total of 459 transports of 262 critically ill patients were carried out, with an average of 51 transports per month. Patients were on ventilatory support (41.3 %) and 34.5 % in use of vasoactive drugs. Adverse events occurred in 9.4% of transports and 77.3 % of the teams were composed of physicians, nurses and nurse technicians.Conclusion: The transport of critically ill patients occurred in the morning period for performing computerized tomographies (CT scans) with patients dependent on mechanical ventilation and vasoactive drugs. During the transports the equipment was functioning, and the adverse events were attributed to clinical changes of patients.
Resumo:
Background: The rapid shallow breathing index (RSBI) is the most widely used index within intensive care units as a predictor of the outcome of weaning, but differences in measurement techniques have generated doubts about its predictive value. Objective: To investigate the influence of low levels of pressure support (PS) on the RSBI value of ill patients. Method: Prospective study including 30 patients on mechanical ventilation (MV) for 72 hours or more, ready for extubation. Prior to extubation, the RSBI was measured with the patient connected to the ventilator (Drager (TM) Evita XL) and receiving pressure support ventilation (PSV) and 5 cmH(2)O of positive end expiratory pressure or PEEP (RSBI_MIN) and then disconnected from the VM and connected to a Wright spirometer in which respiratory rate and exhaled tidal volume were recorded for 1 min (RSBI_ESP). Patients were divided into groups according to the outcome: successful extubation group (SG) and failed extubation group (FG). Results: Of the 30 patients, 11 (37%) failed the extubation process. In the within-group comparison (RSBI_MIN versus RSBI_ESP), the values for RSBI_MIN were lower in both groups: SG (34.79 +/- 4.67 and 60.95 +/- 24.64) and FG (38.64 +/- 12.31 and 80.09 +/- 20.71; p<0.05). In the between-group comparison, there was no difference in RSBI_MIN (34.79 +/- 14.67 and 38.64 +/- 12.31), however RSBI_ESP was higher in patients with extubation failure: SG (60.95 +/- 24.64) and FG (80.09 +/- 20.71; p<0.05). Conclusion: In critically ill patients on MV for more than 72h, low levels of PS overestimate the RSBI, and the index needs to be measured with the patient breathing spontaneously without the aid of pressure support.