297 resultados para ANASTOMOTIC LEAKS
Resumo:
Geological carbon dioxide storage (CCS) has the potential to make a significant contribution to the decarbonisation of the UK. Amid concerns over maintaining security, and hence diversity, of supply, CCS could allow the continued use of coal, oil and gas whilst avoiding the CO2 emissions currently associated with fossil fuel use. This project has explored some of the geological, environmental, technical, economic and social implications of this technology. The UK is well placed to exploit CCS with a large offshore storage capacity, both in disused oil and gas fields and saline aquifers. This capacity should be sufficient to store CO2 from the power sector (at current levels) for a least one century, using well understood and therefore likely to be lower-risk, depleted hydrocarbon fields and contained parts of aquifers. It is very difficult to produce reliable estimates of the (potentially much larger) storage capacity of the less well understood geological reservoirs such as non-confined parts of aquifers. With the majority of its large coal fired power stations due to be retired during the next 15 to 20 years, the UK is at a natural decision point with respect to the future of power generation from coal; the existence of both national reserves and the infrastructure for receiving imported coal makes clean coal technology a realistic option. The notion of CCS as a ‘bridging’ or ‘stop-gap’ technology (i.e. whilst we develop ‘genuinely’ sustainable renewable energy technologies) needs to be examined somewhat critically, especially given the scale of global coal reserves. If CCS plant is built, then it is likely that technological innovation will bring down the costs of CO2 capture, such that it could become increasingly attractive. As with any capitalintensive option, there is a danger of becoming ‘locked-in’ to a CCS system. The costs of CCS in our model for UK power stations in the East Midlands and Yorkshire to reservoirs in the North Sea are between £25 and £60 per tonne of CO2 captured, transported and stored. This is between about 2 and 4 times the current traded price of a tonne of CO2 in the EU Emissions Trading Scheme. In addition to the technical and economic requirements of the CCS technology, it should also be socially and environmentally acceptable. Our research has shown that, given an acceptance of the severity and urgency of addressing climate change, CCS is viewed favourably by members of the public, provided it is adopted within a portfolio of other measures. The most commonly voiced concern from the public is that of leakage and this remains perhaps the greatest uncertainty with CCS. It is not possible to make general statements concerning storage security; assessments must be site specific. The impacts of any potential leakage are also somewhat uncertain but should be balanced against the deleterious effects of increased acidification in the oceans due to uptake of elevated atmospheric CO2 that have already been observed. Provided adequate long term monitoring can be ensured, any leakage of CO2 from a storage site is likely to have minimal localised impacts as long as leaks are rapidly repaired. A regulatory framework for CCS will need to include risk assessment of potential environmental and health and safety impacts, accounting and monitoring and liability for the long term. In summary, although there remain uncertainties to be resolved through research and demonstration projects, our assessment demonstrates that CCS holds great potential for significant cuts in CO2 emissions as we develop long term alternatives to fossil fuel use. CCS can contribute to reducing emissions of CO2 into the atmosphere in the near term (i.e. peak-shaving the future atmospheric concentration of CO2), with the potential to continue to deliver significant CO2 reductions over the long term.
Resumo:
Ulcerative colitis (UC) is characterized by impairment of the epithelial barrier and the formation of ulcer-type lesions, which result in local leaks and generalized alterations of mucosal tight junctions. Ultimately, this results in increased basal permeability. Although disruption of the epithelial barrier in the gut is a hallmark of inflammatory bowel disease and intestinal infections, it remains unclear whether barrier breakdown is an initiating event of UC or rather a consequence of an underlying inflammation, evidenced by increased production of proinflammatory cytokines. UC is less common in smokers, suggesting that the nicotine in cigarettes may ameliorate disease severity. The mechanism behind this therapeutic effect is still not fully understood, and indeed it remains unclear if nicotine is the true protective agent in cigarettes. Nicotine is metabolized in the body into a variety of metabolites and can also be degraded to form various breakdown products. It is possible these metabolites or degradation products may be the true protective or curative agents. A greater understanding of the pharmacodynamics and kinetics of nicotine in relation to the immune system and enhanced knowledge of out permeability defects in UC are required to establish the exact protective nature of nicotine and its metabolites in UC. This review suggests possible hypotheses for the protective mechanism of nicotine in UC, highlighting the relationship between gut permeability and inflammation, and indicates where in the pathogenesis of the disease nicotine may mediate its effect.
Resumo:
The growth of molds on paper containing cellulose is a frequent occurrence when the level of relative air humidity is high or when books become wet due to water leaks in libraries. The aim of this study is to differentiate the bioreceptivity of different types of book paper for different fungi. Laboratory tests were performed with strains of Aspergillus niger, Cladosporium sp., Chaetomium globosum and Trichoderma harzianum isolated from books. Four paper types were evaluated: couche Men (offset), recycled and a reference paper containing only cellulose. The tests were carried out in chambers with relative air humidity of 95% and 100%. Mold growth was greatest in the tests at 100% relative humidity. Results of stereoscopic microscopy observation showed that Cladosporium sp. grew in 74% of these samples, A. niger in 75%, T. harzianum in 72% and C. globosum in 60%. In the chambers with 95% air humidity Cladosporium sp. grew in only 9% of the samples, A. niger in 1%, T harzianum in 3% and C globosum did not grow in any sample. The most bioreceptive paper was couche and the least receptive was recycled paper. The composition of the recycled paper, however, varies depending on the types of waste materials used to make it. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The paper investigates which of Shannon’s measures (entropy, conditional entropy, mutual information) is the right one for the task of quantifying information flow in a programming language. We examine earlier relevant contributions from Denning, McLean and Gray and we propose and motivate a specific quantitative definition of information flow. We prove results relating equivalence relations, interference of program variables, independence of random variables and the flow of confidential information. Finally, we show how, in our setting, Shannon’s Perfect Secrecy theorem provides a sufficient condition to determine whether a program leaks confidential information.
Resumo:
When an accurate hydraulic network model is available, direct modeling techniques are very straightforward and reliable for on-line leakage detection and localization applied to large class of water distribution networks. In general, this type of techniques based on analytical models can be seen as an application of the well-known fault detection and isolation theory for complex industrial systems. Nonetheless, the assumption of single leak scenarios is usually made considering a certain leak size pattern which may not hold in real applications. Upgrading a leak detection and localization method based on a direct modeling approach to handle multiple-leak scenarios can be, on one hand, quite straightforward but, on the other hand, highly computational demanding for large class of water distribution networks given the huge number of potential water loss hotspots. This paper presents a leakage detection and localization method suitable for multiple-leak scenarios and large class of water distribution networks. This method can be seen as an upgrade of the above mentioned method based on a direct modeling approach in which a global search method based on genetic algorithms has been integrated in order to estimate those network water loss hotspots and the size of the leaks. This is an inverse / direct modeling method which tries to take benefit from both approaches: on one hand, the exploration capability of genetic algorithms to estimate network water loss hotspots and the size of the leaks and on the other hand, the straightforwardness and reliability offered by the availability of an accurate hydraulic model to assess those close network areas around the estimated hotspots. The application of the resulting method in a DMA of the Barcelona water distribution network is provided and discussed. The obtained results show that leakage detection and localization under multiple-leak scenarios may be performed efficiently following an easy procedure.
Resumo:
Uma das complicações cirúrgicas que mais afeta o resultado do transplante pulmonar é a complicação da anastomose brônquica. Esta pode apresentar-se com um espectro que vai desde a isquemia transitória da anastomose sem outras alterações até a deiscência total com mediastinite e sépsis. Embora a sua ocorrência tenha diminuído nos últimos anos, continua sendo uma das complicações mais frequentes no pós-operatório. Em nosso trabalho, foi analisada a ocorrência de complicações de anastomose brônquica que necessitaram algum tipo de intervenção cirúrgica na população de pacientes transplantados de pulmão durante um período de dez anos (1989-1999). Este grupo representa a quase totalidade dos transplantes pulmonares realizados no Brasil neste período. Pacientes e Métodos: Foram avaliados todos os transplantes de pulmão realizados em um período de 10 anos (1989-1999) no Pavilhão Pereira Filho, Santa Casa de Misericórdia, Porto Alegre, RS, Brasil, para a ocorrência de complicação da anastomose brônquica e possíveis fatores de risco. Resultados: Em um total de 76 pacientes e 81 anastomoses com o risco de complicação, ocorreram 12 complicações (15,79%). Entre os fatores analisados para risco possivelmente associado à complicação, não houve diferença estatisticamente significativa para o tempo de isquemia superior ou inferior a quatro horas (Teste de Fischer com p=1,00), entre um ou mais de um episódio de rejeição (Teste de Fischer com p=0,756), um ou mais de um pulsos de metilprednisolona (p=0,58), a ocorrência de infecção por citomegalovírus ou não ( teste de Fischer com p=0,169), e nem houve maior número de complicações brônquicas nos pacientes que tiveram maior número de episódios de infecção. Houve diferença estatisticamente entre a técnica de anastomose brônquica término-terminal e a telescopagem brônquica, sendo a ocorrência de complicações bem menor no segundo grupo (teste de Fischer com p=0,005), e também ocorreu diferença estatisticamente significativa entre dois períodos de transplante, de 1989 a 1993 e de 1994 a 1999, sendo a ocorrência menor no segundo grupo (teste exato de Fischer com p=0,037). Conclusões: A técnica de telescopagem brônquica apresentou menor número de complicações da anastomose brônquica, e a maior experiência da equipe de transplantes também contribuiu para a redução das complicações da anastomose.
Resumo:
Government transfers to individuals and families play a central role in the Brazilian social protection system, accounting for almost 14 per cent of GDP in 2009. While their fiscal and redistributive impacts have been widely studied, the macroeconomic effects of transfers are harder to ascertain. We constructed a Social Accounting Matrix (SAM) for 2009 and estimated short-term multipliers for seven different government monetary transfers . The SAM is a double-entry square matrix depicting all income flows in the economy. The data were compiled from the 2009 Brazilian National Accounts and the 2008/2009 POF, a household budget survey. Our SAM was disaggregated into 56 sectors, 110 commodities, 200 household groups and seven factors of production (capital plus six types of labor, according to schooling). Finally, we ran a set of regressions to separate household consumption into ‘autonomous’ (or ‘exogenous’) and ‘endogenous’ components. More specifically, we are interested in the effects of an exogenous injection into each of the seven government transfers outlined above. All the other accounts are thus endogenous. The so-called demand ‘leaks’ are income flows from the endogenous to exogenous accounts. Leaks—such as savings, taxes and imports—are crucial to determine the multiplier effect of an exogenous injection, as they allow the system to go back to equilibrium. The model assumes that supply is perfectly elastic to demand shocks. It assumes that the families’ propensity to save and consumption profile are fixed—that is, rising incomes do not provoke changes in behaviour. The multiplier effects of the on GDP corresponds to the growth in GDP resulting from each additional dollar injected into each transfer seven government transfers. If the government increased Bolsa Família expenditures by 1 per cent of GDP, overall economic activity would grow by 1.78 per cent, the highest effect. The Continuous Cash Benefit, comes second. Only three transfers— the private-sector and public servants’ pensions and FGTS withdrawals—had multipliers lower than unity. The multipliers for other relevant macroeconomic aggregates—household and total consumption, disposable income etc. —reveal a similar pattern. Thus, under the stringent assumptions of our model, we cannot reject the hypothesis that government transfers targeting poor households, such as the Bolsa Família, help foster economic expansion. Naturally, it should be stressed that the multipliers relate marginal injections into government transfers to short-term economic performance either real growth, or inflation if there is no idle capacity which is also useful to analyze. In the long term, there is no doubt that what truly matters is the growth of the country’s productive capacity.
Resumo:
Plasma process like ionic nitriding and cathodic cage plasma nitriding are utilized in order to become hard surface of steels. The ionic nitriding is already accepted in the industry while cathodic cage plasma nitriding process is in industrial implementation stage. Those process depend of plasma parameters like electronic and ionic temperature (Te, Ti), species density (ne, ni) and of distribution function of these species. In the present work, the plasma used to those two processes has been observed through Optical Emission Spectroscopy OES technique in order to identify presents species in the treatment ambient and relatively quantify them. So plasma of typical mixtures like N2 H2 has been monitored through in order to study evolution of those species during the process. Moreover, it has been realized a systematic study about leaks, also thought OES, that accomplish the evolution of contaminant species arising because there is flux of atmosphere to inside nitriding chamber and in what conditions the species are sufficiently reduced. Finally, to describe the physic mechanism that acts on both coating techniques ionic nitriding and cathodic cage plasma nitriding
Resumo:
The transport of fluids through pipes is used in the oil industry, being the pipelines an important link in the logistics flow of fluids. However, the pipelines suffer deterioration in their walls caused by several factors which may cause loss of fluids to the environment, justifying the investment in techniques and methods of leak detection to minimize fluid loss and environmental damage. This work presents the development of a supervisory module in order to inform to the operator the leakage in the pipeline monitored in the shortest time possible, in order that the operator log procedure that entails the end of the leak. This module is a component of a system designed to detect leaks in oil pipelines using sonic technology, wavelets and neural networks. The plant used in the development and testing of the module presented here was the system of tanks of LAMP, and its LAN, as monitoring network. The proposal consists of, basically, two stages. Initially, assess the performance of the communication infrastructure of the supervisory module. Later, simulate leaks so that the DSP sends information to the supervisory performs the calculation of the location of leaks and indicate to which sensor the leak is closer, and using the system of tanks of LAMP, capture the pressure in the pipeline monitored by piezoresistive sensors, this information being processed by the DSP and sent to the supervisory to be presented to the user in real time
Resumo:
Estuaries are environments prone to the input of chemical pollutants of various kinds and origins, including polycyclic aromatic hydrocarbons (PAHs). Anthropogenic PAHs may have two possible sources: pyrolytic (with four or more aromatic rings and low degree of alkylation) and petrogenic (with two and three aromatic rings and high degree of alkylation). This study aimed to evaluate the levels, distribution and possible sources of polycyclic aromatic hydrocarbons in the estuary of the Potengi river, Natal, Brazil. Samples of bottom sediments were collected in the final 12 km of the estuary until its mouth to the sea, where the urbanization of the Great Natal is more concentrated. Sampling was performed on 12 cross sections, with three stations each, totaling 36 samples, identified as T1 to T36. The non alkylated and alkylated PAHs were analyzed by gas chromatography coupled to mass spectrometry (GC / MS). PAHs were detected in all 36 stations with total concentration on each varying 174-109407 ng g-1. These values are comparable to those of several estuarine regions worldwide with high anthropogenic influence, suggesting the record of diffuse contamination installed in the estuary. PAHs profiles were similar for most stations. In 32 of the 36 stations, low molecular weight PAHs (with 2 and 3 ring: naphthalene, phenanthrene and their alkylated homologues) prevailed, which ranged from 54% to 100% of the total PAH, indicating that leaks, spills and combustion fuels are the dominant source of PAH pollution in the estuary. The level of contamination by PAHs in most stations suggests that there is potential risk of occasional adverse biological effects, but in some stations adverse impacts on the biota may occur frequently. The diagnostic ratios could differentiate sources of PAHs in sediments of the estuary, which were divided into three groups: petrogenic, pyrolytic and mixing of sources. The urban concentration of the Great Natal and the various industrial activities associated with it can be blamed as potential sources of PAHs in bottom sediments of the estuary studied. The data presented highlight the need to control the causes of existing pollution in the estuary
Resumo:
The State of Paraíba is one of the most dynamic states of Brazil, strategically located in the northeast, is notable for the excellent potential for integration of different transportation modes forming the states of Rio Grande do Norte, Pernambuco and Alagoas. The dynamic that occurs with port activity causes changes in the space where it is installed. And the elements of this space are always more than suffering direct or indirect influences as the flow in the port is expanded. Therefore, this region became subject to the accidental spillage of oil, because it presents a heavy traffic of ships of various sizes that can run aground or collide with oil causing accidental events. The study of geomorphological and sedimentological compositions of seafloor becomes important as more is known about the relationships between these parameters and associated fauna, and can identify their preferred habitats. The database background, acoustically collected along the proposed study area, is a wealth of information, which were duly examined, cataloged and made available. Such information can serve as an important tool, providing a geomorphological survey of the sedimentary area studied, and come to subsidize, in a flexible, future decision making. With the study area Port of Cabedelo, Paraíba - Brazil, this research aimed to evaluate the influence of the tidal surface and background in modeling the seabed, including the acquisition of information about the location of submerged rocky bodies and the depth of these bodies may turn out to be natural traps for the trapping of oil in case of leaks, and obtain the relationship between types of bed and the hydrodynamic conditions present in the region. In this context, for this study were collected bathymetric data (depth) and physical oceanographic (height of water column, water temperature, intensity and direction of currents, waves and turbidity), meteorological (rainfall, air temperature, humidity, winds and barometric pressure) of the access channel to the Port of Cabedelo / PB and its basin evolution (where the cruise ships dock), and includes tools of remote sensing (Landsat 7 ETM +, 2001), so that images and the results are integrated into Geographic Information Systems and used in the elaboration of measures aimed at environmental protection areas under the influence of this scale facilities, serving as a grant to prepare a contingency plan in case of oil spills in the region. The main findings highlight the techniques of using hydroacoustic data acquisition together bathymetric surveys of high and low frequency. From there, five were prepared in bathymetric pattern of Directorate of Hydrography and Navigation - DHN, with the depth in meters, on a scale of 1:2500 (Channel and Basin Evolution of Access to Port of Cabedelo), where there is a large extent possible beachrocks that hinder the movement of vessels in the port area, which can cause collisions, running aground and leaking oil. From the scatter diagram of the vectors of currents, it can be seen as the tidal stream and undergoes a channeling effect caused by the bidirectional effect of the tide (ebb and flood) in the basin of the Port of Cabedelo evolution in NW-direction SE and the highest speed of the currents occurs at low tide. The characterization weather for the period from 28/02 to 04/07/2010 values was within the expected average for the region of study. The multidisciplinary integration of products (digital maps and remote sensing images), proved to be efficient for the characterization of underwater geomorphological study area, reaching the aim to discriminate and enhance submerged structures, previously not visible in the images
Resumo:
Today a major responsibility for the contamination of soil and groundwater and surface water are establishments known as gas stations of fuel which has attracted increasing attention from both the general population as the state agencies of environmental control due to leaks in storage tanks and mainly to disruption of pipe corrosion of tanks and pumping. Other services, like oil changes and car wash are also causes for concern in this type of establishment. These leaks can cause or waste produced, and the contamination of aquifers, serious health problems and public safety, since most of these stations located in urban areas. Based on this, the work was to evaluate soil contamination of a particular service station and fuel sales in the city of Natal, through the quantification of heavy metals like Cd, Cu, Cr, Ni, Pb, Zn of total organic carbon (TOC) and organic matter using different techniques such as optical emission spectrometry with inductively coupled plasma source (ICP OES), Total Organic Carbon analyzer and gravimetric analysis respectively. And also to characterize the soil through particle size analysis. Samples were taken in 21 georeferenced points and collected in the same period. The soils sampled in sampling stations P3, P5, P6, P10, P11, P12, P13, P14, P15, P17, P18 and P20 showed the smallest size fractions ranging from fine sand to medium sand. The other study sites ranged from fine sand to medium sand, except the point P8 showed that only the type size medium sand and P19, indicating a particle size of the coarse type. The small correlation of organic matter with the elements studied in this work suggests that these are not of anthropogenic origin but geochemical support
Resumo:
The retail fuel stations are partially or potentially polluters and generators of environmental accidents, potentially causing contamination of underground and surface water bodies, soil and air. Leaks in fuel retail stations´ underground storage systems are often detected in Brazil and around the world. Monoaromatic hydrocarbons, BTEX (benzene, toluene, ethylbenzene and xylenes) and polycyclic aromatic hydrocarbons (PAHs) are an indication of the presence of contamination due to its high toxicity. This paper presents a case study of contamination in a Fuel Retail Station by petroleum derivative products in the city of Natal. For identification and quantification of the hydrocarbons, EPA analytical methods were used. The values of benzene quantified by EPA method 8021b CG-PID/FID, ranged from 1.164 to 4.503 mg.Kg-1 in soil samples, and from 12.10 to 27,639 μg.L-1 in underground water samples. Among the PAHs, naphthalene and anthracene showed the most significant results in soil samples, 0.420 to 15.46 mg.Kg-1 and 0.110 to 0,970 mg.Kg-1, respectively. In underground water samples, the results for Naphthalene varied between 0.759 and 614.7 μg.L-1. PAHs were quantified by EPA Method 8270 for GCMS. All of the results for the chemical analysis were compared with the values for the CONAMA 420/2009 resolution. The results for benzene (27,639 μg.L-1) showed levels highly above the recommended by the CONAMA 420 resolution, wherein the maximum permissible for underground water is 5 μg.L-1. This is a worrying factor, since underground water makes up 70% of the city of Natal´s water supply
Resumo:
This work deals with the development of a prototype of a helicopter quadrotor for monitoring applications in oil facilities. Anomaly detection problems can be resolved through monitoringmissions performed by a suitably instrumented quadrotor, i.e. infrared thermosensors should be embedded. The proposed monitoring system aims to reduce accidents as well as to make possible the use of non-destructive techniques for detection and location of leaks caused by corrosion. To this end, the implementation of a prototype, its stabilization and a navigation strategy have been proposed. The control strategy is based on dividing the problem into two control hierarchical levels: the lower level stabilizes the angles and the altitude of the vehicle at the desired values, while the higher one provide appropriate references signals to the lower level in order the quadrotor performs the desired movements. The navigation strategy for helicopter quadrotor is made using information provided by a acquisition image system (monocular camera) embedded onto the helicopter. Considering that the low-level control has been solved, the proposed vision-based navigation technique treats the problem as high level control strategies, such as, relative position control, trajectory generation and trajectory tracking. For the position control we use a control technique for visual servoing based on image features. The trajectory generation is done in a offline step, which is a visual trajectory composed of a sequence of images. For the trajectory tracking problem is proposed a control strategy by continuous servovision, thus enabling a navigation strategy without metric maps. Simulation and experimental results are presented to validate the proposal
Resumo:
The objectives of the IPP Project-Periodic Inspection on Crop Sprayers-are to develop methods for sprayer certification, analyze quality on spray operation, propose an inspection system for crop sprayers in Brazil, improve environmental quality on spray operation, and reduce costs on chemical control for plant protection systems. Periodic inspections on crop sprayers are performed in several countries and are compulsory in most of them, and it is becoming an important tool for improvement and optimization of use of chemicals. The IPP Project in Brazil is funded by FAPESP-Fundação de Amparo a Pesquisa do Estado de São Paulo. The results so far showed that all the sprayers presented failures. However, most of them could be approved with minor services. As an example, 56.6% of the sprayers with more than 2 years of use presented leaks, 47% of them had damaged hoses and 80.5% presented bad tips (nozzles). These results indicate the need for better procedures of use and maintenance of sprayers, justifying the periodic inspection system.