1000 resultados para 82-563


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoluminescence measurements at different temperatures have been performed to investigate the effects of confinement on the electron-phonon interaction in GaAs/AlGaAs quantum wells (QWs). A series of samples with different well widths in the range from 150 up to 750 A was analyzed. Using a fitting procedure based on the Passler-p model to describe the temperature dependence of the exciton recombination energy, we determined a fit parameter which is related to the strength of the electron-phonon interaction. On the basis of the behavior of this fit parameter as a function of the well width thickness of the samples investigated, we verified that effects of confinement on the exciton recombination energy are still present in QWs with well widths as large as 450 angstrom. Our findings also show that the electron-phonon interaction is three times stronger in GaAs bulk material than in Al(0.18)Ga(0.82)As/GaAs QWs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetic and environmental influences on variation in balance performance were measured in 93 monozygous and 83 dizygous female twin pairs aged 21–82 years (mean age, 50.5 years) in Melbourne, Australia, between 1999 and 2003. The authors administered clinical (Lord's Balance Test and Step Test) and laboratory tests of static and dynamic balance from the Chattecx Balance System with and without distractor tasks. The authors conducted factor analysis and estimated genetic and environmental variance components and heritability (defined as additive genetic variance as a proportion of all variance, after adjustment for age) using a multivariate normal model with the statistical package FISHER. Three factors were identified and adjusted for age. Heritability was 46% (standard error (SE), 9) for the "sensory balance tests" factor and 30% (SE, 9) for the "static and dynamic perturbations" factor. For both factors, the remaining variance was attributed to unique environmental effects. There was no evidence that genetic factors influenced variation in the "dynamic weight shift tests" factor, with environmental effects shared by twins accounting for 38% (SE, 7) of variance. Neither genetic nor environmental proportions of variance differed significantly between twin subgroups by age (≤50/>50 years). An age-related decline in performance measures was found across the whole sample. These results imply that balance impairments may have a heritable element.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Aortic intima-media thickness measured by transabdominal ultrasound (aIMT) is an intermediate phenotype of cardiovascular risk. We aimed to (1) investigate the reproducibility of aIMT in a population-derived cohort of infants; (2) establish the distribution of aIMT in early infancy; (3) compare measurement by edge-detection software to that by manual sonographic calipers; and (4) assess the effect of individual and environmental variables on image quality. Methods. Participants were term infants recruited to a population-derived birth cohort study. Transabdominal ultrasound was performed at six weeks of age by one of two trained operators. Thirty participants had ultrasounds performed by both operators on the same day. Data were collected on environmental (infant sleeping, presence of a sibling, use of sucrose, timing during study visit) and individual (post-conception age, weight, gender) variables. Two readers assessed image quality and measured aIMT by edge-detection software and a subset by manual sonographic calipers. Measurements were repeated by the same reader and between readers to obtain intra-observer and inter-observer reliability. Results: Aortic IMT was measured successfully using edge-detection in 814 infants, and 290 of these infants also had aIMT measured using manual sonographic calipers. The intra-reader intra-class correlation (ICC) (n = 20) was 0.90 (95% CI 0.76, 0.96), mean difference 1.5 μm (95% LOA -39, 59). The between reader ICC using edge-detection (n = 20) was 0.92 (95% CI 0.82, 0.97) mean difference 2 μm (95% LOA -45.0, 49.0) and with manual caliper measurement (n = 290) the ICC was 0.84 (95% CI 0.80, 0.87) mean difference 5 μm (95% LOA -51.8, 61.8). Edge-detection measurements were greater than those from manual sonographic calipers (mean aIMT 618 μm (50) versus mean aIMT 563 μm (49) respectively; p < 0.001, mean difference 44 μm, 95% LOA -54, 142). With the exception of infant crying (p = 0.001), no associations were observed between individual and environmental variables and image quality. Conclusion: In a population-derived cohort of term infants, aIMT measurement has a high level of intra and inter-reader reproducibility. Measurement of aIMT using edge-detection software gives higher inter-reader ICC than manual sonographic calipers. Image quality is not substantially affected by individual and environmental factors. © 2014 McCloskey et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The questlon of the crowding-out of private !nvestment by public expenditure, public investment in particular , ln the Brazilian economy has been discussed more in ideological terrns than on empirical grounds. The present paper tries to avoid the limitation of previous studies by estlmatlng an equation for private investment whlch makes it possible to evaluate the effect of economic policies on prlvate investment. The private lnvestment equation was deduced modifylng the optimal flexible accelerator medel (OFAM) incorporating some channels through which public expendlture influences privateinvestment. The OFAM consists in adding adjustment costs to the neoclassical theory of investrnent. The investment fuction deduced is quite general and has the following explanatory variables: relative prices (user cost of capitaljimput prices ratios), real interest rates, real product, public expenditures and lagged private stock of capital. The model was estimated for private manufacturing industry data. The procedure adopted in estimating the model was to begin with a model as general as possible and apply restrictions to the model ' s parameters and test their statistical significance. A complete diagnostic testing was also made in order to test the stability of estirnated equations. This procedure avoids ' the shortcomings of estimating a model with a apriori restrictions on its parameters , which may lead to model misspecification. The main findings of the present study were: the increase in public expenditure, at least in the long run, has in general a positive expectation effect on private investment greater than its crowding-out effect on priva te investment owing to the simultaneous rise in interst rates; a change in economlc policy, such as that one of Geisel administration, may have an important effect on private lnvestment; and reI ative prices are relevant in determining the leveI of desired stock of capital and private investrnent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluated the clinical diagnostic, efficiency for basic death causes in patients dying of circulatory disease and de relative frequency of those diseases. METHODS: Analysis of medical record data of 82 patients, ages from 16 to 84 years old (68 over 40 years old), whose died of circulatory disease and had undergone necropsy in the period from 1988 to 1993 years in the University Hospital of Medicine Faculty of Botucatu-UNESP, Br. RESULTS: The functional class of patients were III or IV, in 78%, and 81.7% needed urgent hospitalization. By the clinical judgment the death were by ischemic heart disease in 32 (21 acute myocardial infarction), Chagas'disease in 12, valvopathy in 11, cardiomyopathy in 7, heart failure with no specification of cardiopathy in 11 and other causes in 9. At the necropsy the death cause was ischemic heart disease in 34 patients, valvopathy in 10, Chagas'disease in 10, cardiomyopathy in 5, and heart failure with no specification of cardiopathy in 2.The concordance taxes were in thhe same order: 94,6%, 90,0%, 83.3%, 71.4% and 28.5%. CONCLUSION: There was a great efficiency of clinical diagnosis for death cause in a general university hospital. The ischemic heart disease were the main causes of death.