991 resultados para 1995_12100603 Optics-12
Resumo:
Recent decreases in costs, and improvements in performance, of silicon array detectors open a range of potential applications of relevance to plant physiologists, associated with spectral analysis in the visible and short-wave near infra-red (far-red) spectrum. The performance characteristics of three commercially available ‘miniature’ spectrometers based on silicon array detectors operating in the 650–1050-nm spectral region (MMS1 from Zeiss, S2000 from Ocean Optics, and FICS from Oriel, operated with a Larry detector) were compared with respect to the application of non-invasive prediction of sugar content of fruit using near infra-red spectroscopy (NIRS). The FICS–Larry gave the best wavelength resolution; however, the narrow slit and small pixel size of the charge-coupled device detector resulted in a very low sensitivity, and this instrumentation was not considered further. Wavelength resolution was poor with the MMS1 relative to the S2000 (e.g. full width at half maximum of the 912 nm Hg peak, 13 and 2 nm for the MMS1 and S2000, respectively), but the large pixel height of the array used in the MMS1 gave it sensitivity comparable to the S2000. The signal-to-signal standard error ratio of spectra was greater by an order of magnitude with the MMS1, relative to the S2000, at both near saturation and low light levels. Calibrations were developed using reflectance spectra of filter paper soaked in range of concentrations (0–20% w/v) of sucrose, using a modified partial least squares procedure. Calibrations developed with the MMS1 were superior to those developed using the S2000 (e.g. coefficient of correlation of 0.90 and 0.62, and standard error of cross-validation of 1.9 and 5.4%, respectively), indicating the importance of high signal to noise ratio over wavelength resolution to calibration accuracy. The design of a bench top assembly using the MMS1 for the non-invasive assessment of mesocarp sugar content of (intact) melon fruit is reported in terms of light source and angle between detector and light source, and optimisation of math treatment (derivative condition and smoothing function).
Resumo:
This paper proposes a multilevel inverter configuration which produces a hexagonal voltage space vector structure in the lower modulation region and a 12-sided polygonal space vector structure in the overmodulation region. A conventional multilevel inverter produces 6n plusmn 1 (n = odd) harmonics in the phase voltage during overmodulation and in the extreme square-wave mode of operation. However, this inverter produces a 12-sided polygonal space vector location, leading to the elimination of 6n plusmn 1 (n = odd) harmonics in the overmodulation region extending to a final 12-step mode of operation with a smooth transition. The benefits of this arrangement are lower losses and reduced torque pulsation in an induction motor drive fed from this converter at higher modulation indexes. The inverter is fabricated by using three conventional cascaded two-level inverters with asymmetric dc-bus voltages. A comparative simulation study of the harmonic distortion in the phase voltage and associated losses in conventional multilevel inverters and that of the proposed inverter is presented in this paper. Experimental validation on a prototype shows that the proposed converter is suitable for high-power applications because of low harmonic distortion and low losses.
Resumo:
The grain size dependencies of the yield and fracture stresses in hot rolled Mg-12.7 at % Cd alloy have been measured in the temperature range 77 to 420 K and are found to be in accordance with HalI-Petch type of equations. In hot rolled Mg-12.7 Cd alloy, the HalI-Petch intercept a w is higher than that in hot rolled magnesium, while the slope ky is comparable. The fracture is intercrystalline at 77 K, mixed mode at 300 K and ductile at 420 K. The above flow and fracture behaviours are interpreted in terms of the complimentary effects of texture hardening and solid solution strengthening.
Resumo:
This paper proposes a multilevel inverter which produces hexagonal voltage space vector structure in lower modulation region and a 12-sided polygonal space vector structure in the over-modulation region. Normal conventional multilevel inverter produces 6n +/- 1 (n=odd) harmonics in the phase voltage during over-modulation and in the extreme square wave mode operation. However, this inverter produces a 12-sided polygonal space vector location leading to the elimination of 6n 1 (n=odd) harmonics in over-modulation region extending to a final 12-step mode operation. The inverter consists of three conventional cascaded two level inverters with asymmetric dc bus voltages. The switching frequency of individual inverters is kept low throughout the modulation index. In the low speed region, hexagonal space phasor based PWM scheme and in the higher modulation region, 12-sided polygonal voltage space vector structure is used. Experimental results presented in this paper shows that the proposed converter is suitable for high power applications because of low harmonic distortion and low switching losses.
Resumo:
Purpose To provide a summary of the classic paper "Differences in the accommodation stimulus response curves of adult myopes and emmetropes" published in Ophthalmic and Physiological Optics in 1998 and to provide an update on the topic of accommodation errors in myopia. Summary The accommodation responses of 33 participants (10 emmetropes, 11 early onset myopes and 12 late onset myopes) aged 18-31 years were measured using the Canon Autoref R-1 free space autorefractor using three methods to vary the accommodation demand: decreasing distance (4 m to 0.25 cm), negative lenses (0 to -4 D at 4 m) and positive lenses (+4 to 0 D at 0.25 m). We observed that the greatest accommodation errors occurred for the negative lens method whereas minimal errors were observed using positive lenses. Adult progressing myopes had greater lags of accommodation than stable myopes at higher demands induced by negative lenses. Progressing myopes had shallower response gradients than the emmetropes and stable myopes; however the reduced gradient was much less than that observed in children using similar methods. Recent Findings This paper has been often cited as evidence that accommodation responses at near may be primarily reduced in adults with progressing myopia and not in stable myopes and/or that challenging accommodation stimuli (negative lenses with monocular viewing) are required to generate larger accommodation errors. As an analogy, animals reared with hyperopic errors develop axial elongation and myopia. Retinal defocus signals are presumably passed to the retinal pigment epithelium and choroid and then ultimately the sclera to modify eye length. A number of lens treatments that act to slow myopia progression may partially work through reducing accommodation errors.
Resumo:
J.W.Lindt’s Colonial man and Aborigine image from the GRAFTON ALBUM: “On chemistry and optics all does not depend, art must with these in triple union blend” (text from J.W. Lindt’s photographic backing card) In this paper, I follow an argument that Lindt held a position in his particular colonial environment where he was simultaneously both an insider and an outsider and that such a position may be considered prerequisite in stimulating exchange. A study of the transition of J.W. Lindt in Grafton, N.S.W. in the 1860s from a traveller to a migrant and subsequently to a professional photographer, as well as Lindt’s photographic career, which evolved through strategic action and technical approaches to photography, bears witness to his cultural relativity. One untitled photograph from this period of work constructs a unique commentary of Australian colonial life that illustrates a non-hegemonic position, particularly as it was included in one of the first albums of photographs of Aborigines that Lindt gifted to an illustrious person (in this case the Mayor of Grafton). As in his other studio constructions, props and backdrops were arranged and sitters were positioned with care, but this photograph is the only one in the album that includes a non-Aborigine in a relationship to an Aborigine. An analysis of the props, technical details of the album and the image suggests a reconciliatory aspect that thwarts the predominant attitudes towards Aborigines in the area at that time.
Resumo:
More than 140 countries offer what has become the international norm for preteritiary education, namely a kindergarten through grade 12 (K-12) system. Why kindergarten? Because, research attests to the long-term learning and social benefits of school readiness programs. Why 12 grades? Because experience in many countries shows that a K-12 system of schooling is the minimum necessary to acquire the knowledge and expertise for university education, employment training, or decent work.
Resumo:
Background: In 2011, Australia published a set of 6 population-level indicators assessing breastfeeding, formula use, and the introduction of soft/semisolid/solid foods. Objectives: This study aimed to report the feeding practices of Australian infants against these indicators and determine the predictors of early breastfeeding cessation and introduction of solids. Methods: Mother–infant dyads (N = 1470) were recruited postnatally in 2 Australian capital cities and regional areas of 1 state between February 2008 and March 2009. Demographic and feeding intention data were collected by self-completed questionnaire at infant birth, with feeding practices (current feeding mode, age of breastfeeding cessation, age of formula and/or solids introduction) reported when the infant was between 4 and 7 months of age, and around 13 months of age. Multiple logistic regression was used to determine the predictors of breastfeeding cessation and solids introduction. Results: Although initiation of breastfeeding was almost universal (93.3%), less than half of the infants were breastfed to 6 months (41.7%) and 33.3% were receiving solids by 4 months. Women who were socially disadvantaged, younger, less educated, unpartnered, primiparous, and/or overweight were most likely to have ceased breastfeeding before 6 months of age, and younger and/or less educated women were most likely to have introduced solid food by 4 months of age. Not producing adequate milk was the most common reason provided for cessation of breastfeeding. Conclusion: The feeding behaviors of Australian infants in the first 12 months fall well short of recommendations. Women need anticipatory guidance as to the indicators of breastfeeding success and the tendency of women to doubt the adequacy of their breast milk supply warrants further investigation.
Resumo:
The tomato I-3 gene introgressed from the Lycopersicon pennellii accession LA716 confers resistance to race 3 of the fusarium wilt pathogen Fusarium oxysporum f. sp. lycopersici. We have improved the high-resolution map of the I-3 region of tomato chromosome 7 with the development and mapping of 31 new PCR-based markers. Recombinants recovered from L. esculentum cv. M82 × IL7-2 F2 and (IL7-2 × IL7-4) × M82 TC1F2 mapping populations, together with recombinants recovered from a previous M82 × IL7-3 F2 mapping population, were used to position these markers. A significantly higher recombination frequency was observed in the (IL7-2 × IL7-4) × M82 TC1F2 mapping population based on a reconstituted L. pennellii chromosome 7 compared to the other two mapping populations based on smaller segments of L. pennellii chromosome 7. A BAC contig consisting of L. esculentum cv. Heinz 1706 BACs covering the I-3 region has also been established. The new high-resolution map places the I-3 gene within a 0.38 cM interval between the molecular markers RGA332 and bP23/gPT with an estimated physical size of 50-60 kb. The I-3 region was found to display almost continuous microsynteny with grape chromosome 12 but interspersed microsynteny with Arabidopsis thaliana chromosomes 1, 2 and 3. An S-receptor-like kinase gene family present in the I-3 region of tomato chromosome 7 was found to be present in the microsyntenous region of grape chromosome 12 but was absent altogether from the A. thaliana genome.
Resumo:
A necessary and sufficient condition for the 4 × 4 Mueller matrix to be derivable from the 2 × 2 Jones matrix is obtained. This condition allows one to determine if a given Mueller matrix describes a totally polarized system or a partially polarized (depolarizing) system. The result of Barakat is analysed in the light of this condition. A recently reported experimentally measured Mueller matrix is examined using this condition and is shown to represent a partially polarized system.
Resumo:
We describe how an ion-exchange waveguide was used as a strip-loading region for a planar polymer waveguide. The loading strip forms an underlay that is well preserved in the substrate. Some branching-channel waveguides were formed by this method, and wall losses were measured. The result shows that the wall losses decrease as a result of strip loading.
Resumo:
The recently introduced generalized pencil of Sudarshan which gives an exact ray picture of wave optics is analysed in some situations of interest to wave optics. A relationship between ray dispersion and statistical inhomogeneity of the field is obtained. A paraxial approximation which preserves the rectilinear propagation character of the generalized pencils is presented. Under this approximation the pencils can be computed directly from the field conditions on a plane, without the necessity to compute the cross-spectral density function in the entire space as an intermediate quantity. The paraxial results are illustrated with examples. The pencils are shown to exhibit an interesting scaling behaviour in the far-zone. This scaling leads to a natural generalization of the Fraunhofer range criterion and of the classical van Cittert-Zernike theorem to planar sources of arbitrary state of coherence. The recently derived results of radiometry with partially coherent sources are shown to be simple consequences of this scaling.
Resumo:
Purpose Transient changes in corneal topography associated with soft and conventional or reverse geometry rigid contact lens wear have been well documented; however, only a few studies have examined the influence of scleral contact lens wear upon the cornea. Therefore, in this study, we examined the influence of modern miniscleral contact lenses, which land entirely on the sclera and overlying tissues, upon anterior corneal curvature and optics. Methods Anterior corneal topography and elevation data were acquired using Scheimpflug imaging (Pentacam HR, Oculus) immediately prior to and following 8 hours of miniscleral contact lens wear in 15 young healthy adults (mean age 22 ± 3 years, 8 East Asian, 7 Caucasian) with normal corneae. Corneal diurnal variations were accounted for using data collected on a dedicated measurement day without contact lens wear. Corneal clearance was quantified using an optical coherence tomographer (RS-3000, Nidek) following lens insertion and after 8 hours of lens wear. Results Although corneal clearance was maintained throughout the 8 hour lens wear period, significant corneal flattening (up to 0.08 ± 0.04 mm) was observed, primarily in the superior mid-peripheral cornea, which resulted in a slight increase in against-the-rule corneal astigmatism (mean +0.02/-0.15 x 94 for an 8 mm diameter). Higher order aberration terms of horizontal coma, vertical coma and spherical aberration all underwent significant changes for an 8 mm corneal diameter (p ≤ 0.01), which typically resulted in a decrease in RMS error values (mean change in total higher order RMS -0.035 ± 0.046 µm for an 8 mm diameter). There was no association between the magnitude of change in central or mid-peripheral corneal clearance during lens wear and the observed changes in corneal curvature (p > 0.05). However, Asian participants displayed a significantly greater reduction in corneal clearance (p = 0.04) and greater superior-nasal corneal flattening compared to Caucasians (p = 0.048). Conclusions Miniscleral contact lenses that vault the cornea induce significant changes in anterior corneal surface topography and higher order aberrations following 8 hours of lens wear. The region of greatest corneal flattening was observed in the superior-nasal mid-periphery, more so in Asian participants. Practitioners should be aware that corneal measurements obtained following miniscleral lens removal may mask underlying corneal steepening.
Resumo:
Considerable progress has been made towards the successful classical biological control of many of Australia’s exotic weeds over the past decade. Some 43 new arthropod or pathogen agents were released in 19 projects. Effective biological control was achieved in several projects with the outstanding successes being the control of rubber vine, Cryptostegia grandiflora, and bridal creeper, Asparagus asparagoides. Significant developments also occurred in target prioritization, procedures for target and agent approval, funding, infrastructure and cooperation between agencies. Scientific developments included greater emphasis on climate matching, plant and agent phylogeny, molecular diagnostics, agent prioritization and agent evaluation.
Resumo:
In this paper, a novel 12-sided polygonal space vector structure is proposed for an induction motor drive. The space vector pattern presented in this paper consists of two 12-sided concentric polygons with the outer polygon having a radius double the inner one. As compared to previously reported 12-sided polygonal space vector structures, this paper subdivides the space vector plane into smaller sized triangles. This helps in reducing the switching frequency of the inverters without deteriorating the output voltage quality. It also reduces the device ratings and dv/dt stress on the devices to half. At the same time, other benefits obtained from the existing 12-sided space vector structure, such as increased linear modulation range and complete elimination of 5th and 7th order harmonics in the phase voltage, are also retained in this paper. The space vector structure is realized by feeding an open-end induction motor with two conventional three-level neutral point clamped (NPC) inverters with asymmetric isolated dc link voltage sources. The neutral point voltage fluctuations in the three-level NPC inverters are eliminated by utilizing the switching state multiplicities for a space vector point. The pulsewidth modulation timings are calculated using sampled reference waveform amplitudes and are explained in detail in this paper. Experimental verification on a laboratory prototype shows that this configuration may be considered suitable for high power drives.