989 resultados para 1995_03270045 TM-45 4501704


Relevância:

20.00% 20.00%

Publicador:

Resumo:

2μm波长激光对人眼安全,在相干探测风切变、非线性频率转换等方面有重要应用。2μm波长激光还可应用到激光医疗,由于其吸收深度浅,手术精度高于发射1μm波长的激光。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

文章报道了室温下二极管泵浦Tm:YAP激光器,最大输出功率5.2瓦,波长为1981nm,斜率效率是30%。实验测量800nm左右晶体的吸收谱以及1800nm附近的荧光发射谱。此外,讨论了输出功率随晶体工作温度关系。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The YAG crystal codoped with Yb3+ and Tm3+ has been grown by Czochralski (Cz) method. The crystal structure of the crystal has been determined by X-ray diffraction analysis. The absorption and emission spectra of Yb,Tm:YAG crystal at room temperature have also been studied. The emission cross-sections have been calculated by Fuechtbauer-Ladenburg formula and reciprocity method. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports that the TM3+:Lu2SiO5 (Tm:LSO) crystal is grown by Czochralski technique. The room-temperature absorption spectra of Tm:LSO crystal are measured on a b-cut sample with 4 at.% thulium. According to the obtained Judd-Ofelt intensity parameters Omega(2)=9.3155 x 10(-20) cm(2), Omega(4)=8.4103 x 10(-20) cm(2), Omega(6)=1.5908 x 10(-20) cm(2), the fluorescence lifetime is calculated to be 2.03 ms for F-3(4) -> H-3(6) transition, and the integrated emission cross section is 5.81 x 10(-18) cm(2). Room-temperature laser action near 2 mu m under diode pumping is experimentally evaluated in Tm:LSO. An optical-optical conversion efficiency of 9.1% and a slope efficiency of 16.2% are obtained with continuous-wave maximum output power of 0.67 W. The emission wavelengths of Tm:LSO laser are centred around 2.06 mu m with spectral bandwidth of similar to 13.6 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the continuous-wave and acousto-optical Q-switched operation of a diode-end-pumped Tm:YAP laser. Continuous-wave output power of 3.5 W at 1.99 mu m was obtained under the absorbed pump power of 14 W. Under Q-switched laser operation, the average output power increased from 1.57 W to 2.0 W, with an absorbed pump power of 12.6 W, as the repetition rate increased from 1 kHz to 10 kHz. The maximum Q-switched pulse energy was 1.57 mJ with a repetition rate of 1 kHz. The minimum pulse width was measured to be about 80 ns, corresponding to a peak power of 19.6 kW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用中频感应提拉法生长了高质量的Tm:Y2SiO5(Tm:YSO)晶体,测定了晶体的晶格常数和分凝系数.运用劳厄照相法确定了单斜晶系Tm:YSO晶体的三个偏振轴〈010〉,D1和D2,在室温下测量了三个偏振轴方向的吸收光谱、荧光光谱和荧光寿命,计算了晶体吸收峰的吸收线宽和吸收截面.研究发现,相对于其他两个偏振轴方向,D1方向在790 nm处出现较强的吸收峰,同时在2μm附近出现了一定强度的发射峰,D1方向的吸收截面较大,荧光寿命较长.Tm:YSO晶体适用于AlGaAs二极管抽运固体激光器,在2μm波段固体激光器的应用上将有很大的发展潜力.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用丘克拉斯基(Czochralski)技术生长了掺铥硅酸镥(Tm∶Lu2SiO5,Tm∶LSO)晶体;测量了LSO晶体在室温下的非偏振吸收光谱和非偏振荧光光谱;利用窄得-奥菲特(Judd-Ofelt)理论计算了Tm∶LSO晶体的窄得-奥菲特强度参数、振子强度、自发辐射概率、辐射寿命、积分吸收截面和积分发射截面.Tm∶LSO晶体的强度参数为Ω2=9.1355×10-20cm2,Ω4=8.4103×10-20cm2,Ω6=1.5908×10-20cm2;Tm∶LSO晶体在1.9μm附近有明显的发射峰(3F4→3H6跃迁),相应的辐射寿命为2.03 ms,积分发射截面为5.81×10-18cm2,半峰全宽(FWHM)为250 nm.用Tm∶LSO晶体在77 K温度下实现了激光运转.利用792 nm的激光二极管(LD)作为抽运源,获得中心波长为1960 nm的激光输出,抽运阈值为2.13 kW/cm2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We reported on a diode end-pumped AO Q-switched Tm:YAP laser at 1937 nm. The average output power was 3.9 W, with a slope efficiency of 29.4% and optical-optical conversion efficiency of 21.6% at a 5-kHz repetition rate. The temperature dependency of the output power and the pulse width at different repetition rates were investigated in details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a diode-pumped, cryogenic and room temperature operation of a Tm,Ho:YAlO3 (c-cut) laser. In a temperature of 77 K, an optical-optical conversion efficiency of 27% and a slope efficiency of 29% were achieved with the maximum continuous-wave (CW) output power of 5.0 W at 2.13 mu m. Acousto-optic switched operation was performed at pulse repetition frequency (PRF) from 1 kHz to 10 kHz, the highest pulse energy of 3.3 mJ in a pulse duration of 40 ns was obtained. In room temperature (RT), the maximum CW power of Tm,Ho:YAlO3 laser was 160 mW with a slope efficiency of 11% corresponding to the absorbed pump power. (C) 2008 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Ho:YAP crystal is grown by the Czochralski technique. The room-temperature polarized absorption spectra of Ho:YAP crystal was measured on a c-cut sample with 1 at% holmium. According to the obtained Judd-Ofelt intensity parameters Omega(2) = 1.42 x 10(-20) cm(2), Omega(4) = 2.92 x 10(-20) cm(2), and Omega(6) = 1.71 x 10(-20) cm(2), this paper calculated the fluorescence lifetime to be 6 ms for I-5(7) -> I-5(8) transition, and the integrated emission cross section to be 2.24 x 10(-18) cm(2). It investigates the room-temperature Ho:YAP laser end-pumped by a 1.91-mu m Tm:YLF laser. The maximum output power was 4.1 W when the incident 1.91-mu m pump power was 14.4W. The slope efficiency is 40.8%, corresponding to an optical-to-optical conversion efficiency of 28.4%. The Ho:YAP output wavelength was centred at 2118 nm with full width at half maximum of about 0.8 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The National Science Foundation of China(Grant No. 60578044).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nutrientes específicos, denominados farmaconutrientes, demonstraram possuir a capacidade de modular a resposta imunológica e inflamatória de animais e seres humanos, em estudos clínicos e laboratoriais. Dentre os substratos conhecidos, os que têm maior relevância e ação imunomoduladora são a arginina, glutamina, ácido graxo n-3 e nucleotídeos. No entanto, revisões sistemáticas e meta-análises buscam consenso em relação aos vários e controversos resultados publicados sobre os possíveis benefícios da imunonutrição em pacientes críticos. Nossos objetivos foram avaliar a efetividade das dietas enriquecidas com Imunonutrientes na redução de complicações e mortalidade nos diferentes tipos de pacientes críticos. O presente estudo é uma revisão sistemática com metanálise onde foram inseridos ensaios clínicos randomizados avaliando o uso de nutrientes imunomoduladores em doente adulto de ambos os sexos, definido como crítico traumatizado, séptico, queimado ou cirúrgico; as dietas utilizadas deveriam conter um ou mais dos imunonutrientes, em qualquer dose, administradas por via enteral comparadas à dieta padrão pela mesma via em pelo menos um dos grupos de comparação. As bases de dados consultadas foram Pubmed e Cinhal, utilizando os termos: Immunonutrition, arginine, glutamine, n-3, nucleotides e criticall illness. De 206 artigos encontrados inicialmente, apenas 35 preencheram os critérios de elegibilidade estabelecidos. Destes 35 ensaios clínicos, 18 foram conduzidos em pacientes cirúrgicos, 6 em pacientes traumatizados, 5 em pacientes queimados, 5 em pacientes críticos em geral e 1 em pacientes sépticos. Para a população geral, não houve redução significativa do risco de morrer indicada pelo RR de 0,84 (IC de 0,68 a 1,05) e os queimados foram mais protegidos de morrer com RR de 0,25 (IC de 0,09 a 0,66); as complicações infecciosas foram reduzidas com RR de 0,56 (IC de 0,42 a 0,73); a incidência de sepse foi reduzida com RR de 0,45 (IC de 0,29 a 0,69), especialmente nos pacientes traumatizados com RR de 0,42 (IC de 0,26 a 0,68); a incidência de abscesso abdominal também foi reduzida com RR de 0,39 (IC de 0,21 a 0,72) e também de bacteremia com RR de 0,46 (IC de 0,31 a 0,66); o tempo de internação hospitalar diminuiu -3,9 dias (IC de -5,0 a -2,8). Para a população de pacientes cirúrgicos: o óbito não apresentou redução significativa do RR de 0,93 (IC de 0,44 a 1,95), as complicações infecciosas foram reduzidas com RR de 0,51 (IC de 0,41 a 0,63), o tempo de internação hospitalar foi reduzido - 3,41 dias (IC de -4,25 a -2,58) e o tempo de internação em UTI -1,72 dias (IC de -2,12 a -1,31). A utilização de dietas com nutrientes imunomoduladores não alterou a mortalidade em doentes críticos ou cirúrgicos. Indivíduos com mais de 60 anos são menos protegidos de morrer pela utilização de dietas com imunomoduladores. As complicações infecciosas são reduzidas em pacientes críticos com a utilização de imunonutrição, em especial a população de pacientes cirúrgicos. Dietas com mais de 10g/l de arginina protegem mais os pacientes críticos da incidência de complicações infecciosas. Pacientes traumatizados são protegidos da incidência de sepse pela utilização da imunonutrição. O tempo de internação hospitalar e o tempo de internação em UTI foram reduzidos em críticos e cirúrgicos com imunonutrição. A execução de ensaios clínicos explanatórios nos diferentes tipos de doentes críticos com um nutriente imunomodulador isolado, seguida de ensaios pragmáticos de acordo com os resultados dos anteriores, é um fato a ser considerado em futuras pesquisas.