875 resultados para validação


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improving the adherence between oilwell metallic casing and cement sheath potentially decrease the number of corrective actions present/y necessary for Northeastern wells submitted to steam injection. In addition to the direct costs involved in the corrective operations, the economic impact of the failure of the primary cementing aIso includes the loss in the production of the well. The adherence between casing and cement is current/y evaluated by a simple shear tests non standardized by the American Petroleum Institute (API). Therefore, the objective of the present is to propose and evaluate a standardized method to assess the adherence of oilwell metallic casing to cement sheath. To that end, a section of a cemented oilwell was simulated and used to test the effect of different parameters on the shear stress of the system. Surface roughness and different cement compositions submitted or not to thermal cycling were evaluated. The results revealed that the test geometry and parameters proposed yielded different values for the shear stress of the system, corresponding to different adherent conditions between metallic casing and cement sheath

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical activity is one of the main components of a healthy lifestyle, responsible for many health benefits. Despite being considered important for both disease prevention and health promotion there is high prevalence of sedentary behavior in the elderly population. Questionnaires are practical and feasible instruments for assessing levels of physical activity. However, they may have limitations in older age ranges. Accelerometers, movement sensors that make physical activity data more objective, emerge as reliable measuring devices. Aim: Determine the validity of the International Physical Activity Questionnaire (IPAQ) adapted for elderly with accelerometry in elderly women. Methods: 57 elderly women, with mean age of 66.05 ± 5.98 years who took part in hypertension control and physical activity incentive programs were assessed in relation to objective and subjective measures of physical activity. The accelerometer was used for 07 consecutive days, 24 hours per day before the IPAQ was applied. Data were analyzed using measures of central tendency and dispersion to characterize the sample according to variables collected. To check the validity of the data we used the Spearman correlation test, considering a significance level of p <0.05. Results: With respect to the categories of physical activity obtained by IPAQ, 46.4% developed moderate physical activity, followed by a high (30.3%) and low level (23.2%). There was a negative correlation only between self-reported time spent sitting and time spent on light activities as measured by accelerometry (r = - 0.408; p = 0.003) and mean activity level (counts/min) with physical activity levels evaluated by IPAQ (r = 0.297; p = 0.036). Conclusion: The IPAQ used in elderly women shows moderate to low validity levels according to accelerometry measures. Assessment of sedentary activities exhibited acceptable levels compared to accelerometry; however, moderate (r = 0.096; p > 0.05) to vigorous (r = 0.098; p > 0.05) activities were not correlated, demonstrating the inability of IPAQ to evaluate this type of activity in elderly women

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The term fatigability concerns the degree of fatigue associated with performing an activity of any type (physical, mental, emotional and / or social). Recently scales for assessing fatigue in the English language were created, however, gaps exist regarding the validity of these scales in relation to oxygen consumption and levels of perceived fatigue. Objective: To investigate the validity of perceived fatigability scale in older women frail and non-frail by the expired gases kinetics. Methods: This is a study of type validation, where were evaluated 48 elderly. The evaluation was conducted at two different sessions. In the first, data were collected demographic partners, as well as assessment of cognitive function, physical health, and the phenotype of frailty. The second was composed by the test 6-minute walk (6MWT) associated the expired gases kinects and assessment of perceived fatigability. Statistical analysis was performed a descriptive analysis and then we used the Pearson correlation test to evaluate the relationship between the measure of perceived fatigue and variables oxygen consumption (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER)before and after 6MWT. We used a linear regression model initially considering the following explanatory variable: age, Body Mass Index (BMI), presence of frailty, comorbidities, level of physical activity, distance covered in the 6MWT , the energy cost of walking and severity of fatigability on performance. Results: The final sample consisted of 44 elderly women, 4 elderly were excluded because they didn t complete all phases of this study. The mean age obtained was 75 years (± 7.2 years). There was no significant correlation between fatigability measures and the values of VO2 ( r = .09 , p = .56 ) , VCO2 ( r = .173 , p = .26 ) , RER ( r = - .121 , p = .43 ). The final linear regression model showed that the energy cost of walking, the usual level of physical activity and the performance severity of fatigability explained 83.5 % (R2 = 0.835, p < 0.01) of the variation in the perceived fatigability. Conclusion: Our findings indicate a relationship between greater severity of fatigability and lower levels of physical activity and increased energy cost in walking, suggesting that the fatigability analyses using a simple numeric scale is valid and viable for assessment of fatigue in older women

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esse estudo se propôs a avaliar um método auxiliar de diagnóstico (DIAGNOdent®) na predição de cárie de dentina em dentes decíduos, através de validação histológica e de microdureza. Verificando possíveis diferenças entre os valores obtidos através do método auxiliar, além de determinar um ponto de corte para parada de remoção de tecido cariado. A amostra do estudo foi de 15 crianças que apresentaram 21 cavidades de cárie, tratadas e analisadas desde antes da realização da restauração até quando da exodontia do elemento dentário. Os espécimes foram analisados através do DIAGNOdent® antes da abertura das cavidades, após a remoção do tecido cariado e depois da reabertura das cavidades que se deu após a exodontia dos elementos dentários. Posteriormente, receberam preparo metalográfico para realização de testes de microdureza e microscopia óptica que serviram como forma de validação para as mensurações obtidas pela fluorescência a laser. Houve diferença significativa entre os valores DIAGNOdent® encontrados antes da abertura da cavidade e os demais (p < 0,0001). Havendo correlação significativa (r = 0,432 ; p = 0,019) apenas para as aferições obtidas antes da abertura das cavidades e quando do término da remoção do tecido cariado. Para a microdureza, as médias axiais foram significativamente maiores que as pulpares, existindo correlação entre a microdureza pulpar e os valores do DIAGNOdent® após a reabertura (r = - 0,472 ; p = 0,002). Valores de 15,38% para a sensibilidade, 100% para a especificidade, 100% para o valor preditivo positivo e 71,79% para o valor preditivo negativo, foram obtidos quando se utilizou um ponto de corte de 30 para fluorescência a laser, tendo como padrão-ouro a microdureza pulpar. Partindo da média dos valores de fluorescência a laser obtidos após a remoção do tecido cariado e acrescentando-se um desvio-padrão a esta, o método indicou o valor de 19 como ponto de corte para cessar a remoção de dentina. Concluiu-se que, nas condições analisadas, o método auxiliar de diagnóstico (DIAGNOdent®) é um método acurado na predição de cárie de dentina em dentes decíduos. Além disso, o método comprovou que o padrão usual de remoção de dentina garante a remoção do tecido cariado

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of the motivation to practice physical activities is relevant once through this it is possible to develop intervention strategies for sedentary population. In this way, the present dissertation aimed to adapt and validate for the Brazilian context the Motives for Physical Activity Measure Revised (MPAM-R). It was investigated yet the relation of some socio-demographic variables (age, gender, Body Mass Index - BMI, types of physical activity; way to practice and time of practice) and the participants means in the motives studied. The physical activity (PA) is defined as any bodily movement produced by skeletal muscles resulting in energy expenditure above the basal level. However, in the present study it was considered motivation for two types of PA: the physical exercises and sports. The Self-Determination Theory (SDT) underlay this research, once it has been used in the sportive context, beyond the facto of it was used as theoretical base to the development of MPAM-R. To attain the proposed goals, it was accomplished translations to Portuguese of the original English scale. Next, was carried out the semantic analysis and the judge analysis. For the empirical analysis of items, participated 309 practitioner of PA, classified in physical exercises practitioners and sports practitioners, with ages between 16 and 74 years, distributed equally by sex. They answered the final version in Portuguese of the MPAM-R and socio-demographic questions. The data was collected in Natal/RN, where the researcher approached people in some places where the PA is practiced, following she communicated that their involvement will be spontaneous and their responses will be confidential. The obtained results pointed the confirmation of the existence of five factors in the final version of the instrument, that was composed by 26 items that presented the following statistics indexes: x² (289) = 757.75, p < 0.000, x²/DF = 2.62, with GFI of 0.83, AGFI of 0.80 and RMSEA of 0.07. The reliability (Cronbach Alpha) of the complete instrument was 0.90, and the indexes of each factor were considered satisfactory too: Enjoyment (α = 0.88), Health (α = 0.84), Appearance (α = 0.79), Competence (α = 0.85) and Social (α = 0.75). It was observed that, in general, the main motive presented by the participants to practice PA was Health. It was verified yet, that women and aged had a higher mean in the Health factor; among the exercise practitioners was found a higher mean in the Appearance factor; and a higher mean in the Social factor was found among those that practice PA with accompaniment. It was concluded that the MPAM-R presented satisfactory psychometric parameters, became it useful in futures researches. Moreover, proposed the accomplishment of new studies that considered others variables to the intent of the better understanding of motivation to practice physical activity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While providing physical and psychological benefits, excessive exercise could be or cause a compulsive behavior, making the individual dependent on it. In a parallel discussion, computerized psychological instruments, for a hand, reflects the development of information technology and your applicability to other areas, but also shows little advance for Psychological Assessment. In this perspective, this study aims to adapt the Exercise Dependence Scale (EDS-R) in two formats (paper-and-pencil and computerized) and evaluate evidence of factorial and convergent validity, and reliability of each version and compare them with each other. It is also proposed to observe the relationship of some bio-demographic (Sex, age, frequency, duration and intensity of practice exercise) and the exercise dependence (DEF). For this purpose, 709 regular physical activity practitioners, selected by procedures non-probabilistic sampling, responded a adapted version of EDS-R, Muscle Appearance Satisfaction Scale (MASS), Body Modification Scale (BMS) and a demographic questionnaire, analyzed through Exploratory Factor Analysis, Cronbach's Alpha and not parametric tests. Both the traditional version and the computer showed a seven factors structure, explaining 57 and 62% of the variance, respectively, and Cronbach's alphas of 0.83 and 0.89. Factors were: (1) intentionality, (2) continuity, (3) tolerance, (4) reduction of other activities, (5) lack of control, (6) abstinence and (7) time spent on exercise. Relationships were observed between the Exercise Dependence and the variables: age, diets, consumption of food supplements and medicines for weight change, desire to do plastic surgery and body satisfaction. We observed also a positive correlation between the DEF and the frequency, duration and intensity of exercise, and the factor "Dependence on exercising" from MASS, indicating convergent validity of the EDS-R. Finally, comparisons between the two formats were equivalent, with few changes: computerized version achieved higher DEF scores. Based on these results, it can be concluded that the EDS-R has factorial and convergent validity, reliability, to measure exerceise dependence on traditional e computerized formats. DEF is related to actions used to body modification and behaviors toward exercise. Finally, it was found equivalence between the formats, especially in psychometric parameters, thus suggesting feasibility of a computerized assessment. However, it was observed that the computerized data has sample recruiting strategies more limited

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we worked with the validation of a methodology for analysis of bioactive amines in shrimp, considering it to be one of the main products of the northriograndense trade balance, maintaining the state of Rio Grande do Norte topped the list of Brazilian exports of this product the last decade. The sector of the Brazilian shrimp works exclusively with gray shrimp Litopenaeus Vannamei since the late 1990s. This study used liquid chromatography with conductimetric detector, using as the mobile phase methylsulfonic 3 mM acid (MSA) with gradient and phase C18 column with reverse the development of methodology for the analysis of bioactive amines in shrimp. In the sample preparation was used as 5% trichloroacetic acid (TCA) extraction solution. Validation analysis of biotativas amines (putrescine - PUT, histamine - HIST, agmatine - AGM, spermidine - EPD and spermine - EPN) in shrimp, the linear working range was 0.1 to 2.0 mg L-1 to was sensitive, homoscedastic, in effect, selective, accurate and precise array. Thus, considered feasible for these determinations bioactive amines in this array. Determined the concentration of these amines in fresh shrimps (AGM = 0.61 ± 0.05 mg kg- 1 EPD = 2.57 ± 0.14 mg kg-1 and EPN = 1.79 ± 0.11 mg kg-1), and freezing weather predetermined in cooked shrimp (AGM = 6.28 ± 0.18 mg kg-1, EPD = 12.72 ± 0.02 mg kg- 1 and EPN = 22.30 ± 0.60 mg kg-1), the shrimp with twenty-four hour stay at room temperature (PUT = 879.52 ± 28.12 mg kg-1, AGM = 848.13 ± 19.40 mg kg-1, ESPD = 13.59 ± 0.97 mg kg-1 and ESPN = 18.47 + 1.57 mg kg-1). In shrimp subjected to freezing for a week, two weeks, three weeks and four weeks, the results showed that there is an increase in the content of agmatine (7.31 ± 0.21 mg kg-1) while in spermine ( 1.22 ± 0.14 mg kg-1) and spermidine (below limit of quantification) there was a decrease in the freeze time, while there is a decrease in the level of spermidine not reaching detectad. The putrescine was only found in shrimp that remained for 24 hours at room temperature and histamine was not found in any of the samples

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dentre os vários aspectos da saúde do idoso, a saúde bucal merece atenção especial pelo fato de que, historicamente, nos serviços odontológicos, não se considera esse grupo populacional como prioridade de atenção. Por isso, se faz necessária a produção de um indicador multidimensional capaz de mensurar todas as alterações bucais encontradas em um idoso, facilitando a categorização da saúde bucal como um todo. Tal indicador representará um importante instrumento capaz de elencar prioridades de atenção voltadas à população idosa. Portanto, o estudo em questão propõe a produção e validação de um indicador de saúde bucal a partir dos dados secundários coletados pelo projeto SB Brasil 2010 referente ao grupo etário de 65 a 74 anos. A amostra foi representada pelos 7619 indivíduos do grupo etário de 65 a 74 anos que participaram da pesquisa nas 5 (cinco) regiões do Brasil. Tais indivíduos foram submetidos à avaliação epidemiológica das condições de saúde bucal, a partir dos índices CPO-d, CPI e PIP. Além disso, verificou-se o uso e necessidade de prótese, bem como características sociais, econômicas e demográficas. Uma análise fatorial identificou um número relativamente pequeno de fatores comuns, através da análise de componentes principais. Após a nomenclatura dos fatores, foi realizada a soma dos escores fatoriais por indivíduo. Por último, a dicotomização dessa soma nos forneceu o indicador de saúde bucal proposto. Para esse estudo foram incluídas na análise fatorial 12 variáveis de saúde bucal oriundas do banco de dados do SB Brasil 2010 e, também 3 variáveis socioeconômicas e demográficas. Com base no critério de Kaiser, observa-se que foram retidos cinco fatores que explicaram 70,28% da variância total das variáveis incluídas no modelo. O fator 1 (um) explica sozinho 32,02% dessa variância, o fator 2 (dois) 14,78%, enquanto que os fatores 3 (três), 4 (quatro) e 5 (cinco) explicam 8,90%, 7,89% e 6,68%, respectivamente. Por meio das cargas fatoriais, o fator um foi denominado dente hígido e pouco uso de prótese , o dois doença periodontal presente , o três necessidade de reabilitação , já o quarto e quinto fator foram denominados de cárie e condição social favorável , respectivamente. Para garantir a representatividade do indicador proposto, realizou-se uma segunda análise fatorial em uma subamostra da população de idosos investigados. Por outro lado, a aplicabilidade do indicador produzido foi testada por meio da associação do mesmo com outras variáveis do estudo. Por fim, Cabe ressaltar que, o indicador aqui produzido foi capaz de agregar diver sas informações a respeito da saúde bucal e das condições sociais desses indivíduos, traduzindo assim, diversos dados em uma informação simples, que facilita o olhar dos gestores de saúde sobre as reais necessidades de intervenções em relação à saúde bucal de determinada população

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Symbolic Data Analysis (SDA) main aims to provide tools for reducing large databases to extract knowledge and provide techniques to describe the unit of such data in complex units, as such, interval or histogram. The objective of this work is to extend classical clustering methods for symbolic interval data based on interval-based distance. The main advantage of using an interval-based distance for interval-based data lies on the fact that it preserves the underlying imprecision on intervals which is usually lost when real-valued distances are applied. This work includes an approach allow existing indices to be adapted to interval context. The proposed methods with interval-based distances are compared with distances punctual existing literature through experiments with simulated data and real data interval

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: O ensaio do cometa ou técnica da eletroforese de células isoladas é largamente empregado para avaliação de danos e reparo do DNA em células individuais. O material pode ser corado por técnicas de fluorescência ou por sal de prata. Este último apresenta vantagens técnicas, como o tipo de microscópio utilizado e a possibilidade de armazenamento das lâminas. A análise dos cometas pode ser feita de modo visual, porém há a desvantagem da subjetividade dos resultados, que pode ser minimizada por análise digital automatizada. OBJETIVOS: Desenvolvimento e validação de método de análise digital de cometas corados por sal de prata. MÉTODOS: Cinquenta cometas foram fotografados de maneira padronizada e impressos em papel. Além de medidas manualmente, essas imagens foram classificadas em cinco categorias por três avaliadores, antes e depois de pré-processadas automaticamente pelo software ImageJ 1.38x. As estimativas geradas pelos avaliadores foram comparadas quanto sua correlação e reprodutibilidade. em seguida, foram desenvolvidos algoritmos de análise digital das medidas, com base em filtros estatísticos de mediana e de mínimo. Os valores obtidos foram comparados com os estimados manual e visualmente após o pré-processamento. RESULTADOS: As medidas manuais das imagens pré-processadas apresentaram maior correlação intraclasse do que as imagens preliminares. Os parâmetros automatizados apresentaram alta correlação com as medidas manuais pré-processadas, sugerindo que este sistema aumenta a objetividade da análise, podendo ser utilizado na estimativa dos parâmetros dos cometas. CONCLUSÃO: A presente análise digital proposta para o teste do cometa corado pela prata mostrou-se factível e de melhor reprodutibilidade que a análise visual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artigo apresenta o desenvolvimento, validação e utilização de uma metodologia de avaliação da qualidade dos serviços de atenção primária do Sistema Único de Saúde (SUS), o Questionário de Avaliação da Qualidade de Serviços de Atenção Básica (QualiAB). Destina-se aos serviços de atenção básica, organizados segundo diferentes modelos de atenção, incluindo a Saúde da Família. Contém 50 indicadores sobre oferta e organização do trabalho assistencial e programático e 15 sobre gerenciamento, na forma de questões de múltipla escolha, autorespondidas via web pela equipe local do serviço. Confere a cada resposta valor zero, um ou dois; a média geral atribui ao serviço um grau de qualidade expresso pela distância do melhor padrão correspondente à média dois. Foi construído por processo de consenso interativo, que incluiu metodologias qualitativas, teste-piloto, aplicação em 127 serviços, validação de construto e confiabilidade. Respondido, em 2007, por 598 (92%) dos serviços de 115 municípios paulistas, mostrou bom poder para discriminar níveis de qualidade. Adotado em 2010 como parte de um programa de apoio à Atenção Básica da Secretaria de Estado da Saúde de São Paulo, foi respondido por 95% (2.735) dos serviços de 586 municípios (90,8% do Estado). Os resultados foram encaminhados aos municípios. O QualiAB fornece uma avaliação válida, simples e com a possibilidade de retorno imediato para gerentes e profissionais. Mostrou factibilidade, aceitabilidade, bom poder de discriminação e utilidade para auxiliar a gestão da rede de atenção básica do SUS em São Paulo. A experiência indica aplicabilidade nas redes de atenção básica do Brasil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em meados da década de 50 iniciou-se o desenvolvimento da citometria de fluxo, tecnologia que permite verificar características físico-químicas de células ou partículas suspensas em meio fluido. Esta tecnologia utiliza anticorpos monoclonais marcados com fluorocromos como ferramenta de investigação em diversas análises e necessita de controles isotípicos para definição da região negativa (background). Estes controles são constituídos por imunoglobulinas de mesmo isotipo e fluorocromo dos anticorpos testes, sendo o isotiocianato de fluoresceína (FITC) o marcador fluorescente mais utilizado na conjugação de anticorpos. Os controles isotípicos têm como função definir a fluorescência inespecífica (células negativas) e as regiões fluorescentes (células positivas). No presente estudo foi selecionado anticorpo monoclonal murino (AcMm) dirigido contra antígeno eritrocitário canino, produzido no Laboratório de Anticorpos Monoclonais do Hemocentro de Botucatu, o qual reage positivamente com hemácias de cães, mas nunca com leucócitos humanos, tendo, portanto, potencial utilidade como controle negativo em citometria de fluxo. A purificação do AcMm da subclasse IgG1 foi feita por cromatografia de afinidade em Proteína-A Sepharose, e o controle da purificação realizado por eletroforese em géis de ágarose e poliacrilamida (SDS-PAGE). A imunoglobulina purificada foi conjugada ao FITC e filtrado em coluna de Sephadex G-25 para separação das proteínas marcadas e não-marcadas. O AcMm conjugado foi testado contra hemácias de cães, e o êxito da conjugação comprovado por testes de fluorescência, sendo a mediana de positividade de 94,70. Frente a leucócitos humanos a mediana de positividade foi 0,03 contra 0,50 dos reagentes comerciais. Os testes estatísticos não-paramétricos de Wilcoxon e correlação de Spearman comprovaram a eficiência e validam o controle isotípico produzido em comparação aos reagentes comerciais testados.