973 resultados para upper primary


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant issue in primary teacher education is developing a knowledge base which prepares teachers to teach in a range of subject areas. In Australia, the problem in primary social science education is compounded by the integrated nature of the key learning area of Studies of Society and Environment (SOSE). Recent debates on teaching integrated social sciences omit discussions on the knowledge base for teaching. In this paper, a case study approach is used to investigate primary pre-service teachers’ approaches to developing a knowledge base in designing a SOSE curriculum unit. Data from five teacher-educators who taught primary SOSE curriculum indicates that novice teachers’ subject content knowledge, as revealed through their curriculum planning, lacked a disciplinary basis. However, understanding of inquiry learning, which is fundamental to social science education, was much stronger. This paper identifies a gap in the scholarship on teaching integrated social science and illustrates the need to support and develop primary teachers’ disciplinary knowledge in teacher education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims & Rationale/Objectives: With the knowledge that overweight is a major public health concern in Australia, that a multidisciplinary team approach to the management of lifestyle-related conditions is supported, and that the Australian Government recently recognised the role of the exercise physiologist (EP) in reducing the health burden of disease by their inclusion for reimbursement under the Medicare Plus scheme, this study sought to undertake a pilot RCT to compare GP and EP interventions to reduce primary cardiovascular risk in the overweight general practice population. Methods and Measures: Overweight patients recruited by a convenience sample of GPs were randomised into one of three arms: the control group, or the GP or EP intervention group (in which patients received either five GP or five EP consultations over 24 weeks). Patients had baseline, 12- and 24-week measures of body composition and cardio-respiratory fitness, and completed baseline and end-of-study surveys, fasting lipids and glucose. GPs and EPs completed an end-of-study survey. Results:Sixty-seven patients attended the baseline assessment. Overall retention rate was 67%. Patients were generally satisfied with the effectiveness of the interventions and their weight reduction. Favourable trends in BMI, weight, glucose and exercise levels for GP and EP intervention groups and in physical activity levels for all groups Conclusions: This study supports the feasibility of a RCT of GP and EP interventions for decreasing primary cardiovascular risk in the overweight general practice population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eyelids play an important role in lubricating and protecting the surface of the eye. Each blink serves to spread fresh tears, remove debris and replenish the smooth optical surface of the eye. Yet little is known about how the eyelids contact the ocular surface and what pressure distribution exists between the eyelids and cornea. As the principal refractive component of the eye, the cornea is a major element of the eye’s optics. The optical properties of the cornea are known to be susceptible to the pressure exerted by the eyelids. Abnormal eyelids, due to disease, have altered pressure on the ocular surface due to changes in the shape, thickness or position of the eyelids. Normal eyelids also cause corneal distortions that are most often noticed when they are resting closer to the corneal centre (for example during reading). There were many reports of monocular diplopia after reading due to corneal distortion, but prior to videokeratoscopes these localised changes could not be measured. This thesis has measured the influence of eyelid pressure on the cornea after short-term near tasks and techniques were developed to quantify eyelid pressure and its distribution. The profile of the wave-like eyelid-induced corneal changes and the refractive effects of these distortions were investigated. Corneal topography changes due to both the upper and lower eyelids were measured for four tasks involving two angles of vertical downward gaze (20° and 40°) and two near work tasks (reading and steady fixation). After examining the depth and shape of the corneal changes, conclusions were reached regarding the magnitude and distribution of upper and lower eyelid pressure for these task conditions. The degree of downward gaze appears to alter the upper eyelid pressure on the cornea, with deeper changes occurring after greater angles of downward gaze. Although the lower eyelid was further from the corneal centre in large angles of downward gaze, its effect on the cornea was greater than that of the upper eyelid. Eyelid tilt, curvature, and position were found to be influential in the magnitude of eyelid-induced corneal changes. Refractively these corneal changes are clinically and optically significant with mean spherical and astigmatic changes of about 0.25 D after only 15 minutes of downward gaze (40° reading and steady fixation conditions). Due to the magnitude of these changes, eyelid pressure in downward gaze offers a possible explanation for some of the day-to-day variation observed in refraction. Considering the magnitude of these changes and previous work on their regression, it is recommended that sustained tasks performed in downward gaze should be avoided for at least 30 minutes before corneal and refractive assessment requiring high accuracy. Novel procedures were developed to use a thin (0.17 mm) tactile piezoresistive pressure sensor mounted on a rigid contact lens to measure eyelid pressure. A hydrostatic calibration system was constructed to convert raw digital output of the sensors to actual pressure units. Conditioning the sensor prior to use regulated the measurement response and sensor output was found to stabilise about 10 seconds after loading. The influences of various external factors on sensor output were studied. While the sensor output drifted slightly over several hours, it was not significant over the measurement time of 30 seconds used for eyelid pressure, as long as the length of the calibration and measurement recordings were matched. The error associated with calibrating at room temperature but measuring at ocular surface temperature led to a very small overestimation of pressure. To optimally position the sensor-contact lens combination under the eyelid margin, an in vivo measurement apparatus was constructed. Using this system, eyelid pressure increases were observed when the upper eyelid was placed on the sensor and a significant increase was apparent when the eyelid pressure was increased by pulling the upper eyelid tighter against the eye. For a group of young adult subjects, upper eyelid pressure was measured using this piezoresistive sensor system. Three models of contact between the eyelid and ocular surface were used to calibrate the pressure readings. The first model assumed contact between the eyelid and pressure sensor over more than the pressure cell width of 1.14 mm. Using thin pressure sensitive carbon paper placed under the eyelid, a contact imprint was measured and this width used for the second model of contact. Lastly as Marx’s line has been implicated as the region of contact with the ocular surface, its width was measured and used as the region of contact for the third model. The mean eyelid pressures calculated using these three models for the group of young subjects were 3.8 ± 0.7 mmHg (whole cell), 8.0 ± 3.4 mmHg (imprint width) and 55 ± 26 mmHg (Marx’s line). The carbon imprints using Pressurex-micro confirmed previous suggestions that a band of the eyelid margin has primary contact with the ocular surface and provided the best estimate of the contact region and hence eyelid pressure. Although it is difficult to directly compare the results with previous eyelid pressure measurement attempts, the eyelid pressure calculated using this model was slightly higher than previous manometer measurements but showed good agreement with the eyelid force estimated using an eyelid tensiometer. The work described in this thesis has shown that the eyelids have a significant influence on corneal shape, even after short-term tasks (15 minutes). Instrumentation was developed using piezoresistive sensors to measure eyelid pressure. Measurements for the upper eyelid combined with estimates of the contact region between the cornea and the eyelid enabled quantification of the upper eyelid pressure for a group of young adult subjects. These techniques will allow further investigation of the interaction between the eyelids and the surface of the eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The cornea is known to be susceptible to forces exerted by eyelids. There have been previous attempts to quantify eyelid pressure but the reliability of the results is unclear. The purpose of this study was to develop a technique using piezoresistive pressure sensors to measure upper eyelid pressure on the cornea. Methods: The technique was based on the use of thin (0.18 mm) tactile piezoresistive pressure sensors, which generate a signal related to the applied pressure. A range of factors that influence the response of this pressure sensor were investigated along with the optimal method of placing the sensor in the eye. Results: Curvature of the pressure sensor was found to impart force, so the sensor needed to remain flat during measurements. A large rigid contact lens was designed to have a flat region to which the sensor was attached. To stabilise the contact lens during measurement, an apparatus was designed to hold and position the sensor and contact lens combination on the eye. A calibration system was designed to apply even pressure to the sensor when attached to the contact lens, so the raw digital output could be converted to actual pressure units. Conclusions: Several novel procedures were developed to use tactile sensors to measure eyelid pressure. The quantification of eyelid pressure has a number of applications including eyelid reconstructive surgery and the design of soft and rigid contact lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Written by the surgeons of the Exeter Hip Team and their colleagues from around the world, this book describes 40 years of innovation and development with cemented hip replacement. Topics covered include the basic science behind successful cemented hip replacement, modern surgical techniques and recent advances. There is also extensive coverage of the revision techniques developed at Exeter and elsewhere, focussing on femoral and acetabular impaction grafting. Each chapter is a self-contained article with an emphasis, where appropriate, on practical techniques and surgical tips, supported by line drawings and intra-operative photographs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The objective of routine outpatient assessment of well functioning patients after primary total hip arthroplasty (THA) is to detect asymptomatic failure of prostheses to guide recommendations for early intervention. We have observed that the revision of THAs in asymptomatic patients is highly uncommon. We therefore question the need for routine follow-up of patients after THA. Methods: A prospective analysis of an orthopaedic database identified 158 patients who received 177 revision THAs over a 4 year period. A retrospective chart review was conducted. Patient demographics, primary and revision surgery parameters and follow-up information was recorded and cross referenced with AOA NJRR data. Results: 110 THAs in 104 patients (average age 70.4 (SD 9.8 years). There were 70 (63.6%) total, 13 (11.8%) femoral and 27 (24.5%) acetabular revisions. The indications for revision were aseptic loosening (70%), dislocation (8.2%), peri-prosthetic fracture (7.3%), osteolysis (6.4%) and infection (4.5%). Only 4 (3.6%) were asymptomatic revisions. A mean of 5.3 (SD 5.2 and 1.9 (SD 5.3 follow-up appointments were required before revision in patients with and without symptoms, respectively. The average time from the primary to revision surgery was 11.8 (SD 7.23) years. Conclusions: We conclude that patients with prostheses with excellent long term clinical results as validated by Joint Registries, routine follow-up of asymptomatic THA should be questioned and requires further investigation. Based on the work of this study, the current practice of routine follow-up of asymptomatic THA may be excessively costly and unnecessary and a less resource-intensive review method may be more appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current healthcare models promote the equitable provision of palliative care to oncology patients with advancing disease, in the setting of their usual care, often in conjunction with anti-cancer therapies. This has resulted in specialist cancer services, as well as primary care across metropolitan, rural and remote communities, being called upon to integrate palliative care principles into their practice. To meet this increased demand for skilled health care professionals several national strategies have been initiated over the last five years. In this paper two projects are discussed in detail: the Palliative Care Curriculum for Undergraduates and the Program of Experience in the Professional Approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spectrum sensing is considered to be one of the most important tasks in cognitive radio. Many sensing detectors have been proposed in the literature, with the common assumption that the primary user is either fully present or completely absent within the window of observation. In reality, there are scenarios where the primary user signal only occupies a fraction of the observed window. This paper aims to analyse the effect of the primary user duty cycle on spectrum sensing performance through the analysis of a few common detectors. Simulations show that the probability of detection degrades severely with reduced duty cycle regardless of the detection method. Furthermore we show that reducing the duty cycle has a greater degradation on performance than lowering the signal strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no denying that the information technology revolution of the late twentieth century has arrived. Whilst not equitably accessible for many, others hold high expectations for the contributions online activity will make to student learning outcomes. Concurrently, and not necessarily consequentially, the number of science and technology secondary school and university graduates throughout the world has declined substantially, as has their motivation and engagement with school science (OECD, 2006). The aim of this research paper is to explore one aspect of online activity, that of forum-based netspeak (Crystal, 2006), in relation to the possibilities and challenges it provides for forms of scientific learning. This paper reports findings from a study investigating student initiated netspeak in a science inspired multiliteracies (New London Group, 2000) project in one middle primary (aged 7-10 years) multi-age Australian classroom. Drawing on the theoretical description of the Five phases of enquiry proposed by Bybee (1997), an analytic framework is proffered that allows identification of student engagement, exploration, explanation, elaboration and evaluation of scientific enquiry. The findings provide insight into online forums for advancing learning in and motivation for science in the middle primary years.