891 resultados para organ-on-a-chip


Relevância:

80.00% 80.00%

Publicador:

Resumo:

InGaN/GaN multi-quantum-well-structure laser diodes with an array structure are successfully fabricated on sapphire substrates. The laser diode consists of four emitter stripes which share common electrodes on one laser chip. An 800-mu m-long cavity is formed by cleaving the substrate along the < 1 (1) over bar 00 >. orientation using laser scriber. The threshold current and voltage of the laser array diode are 2A and 10.5 V, respectively. A light output peak power of 12W under pulsed current injection at room temperature is achieved. We simulate the electric properties of GaN based laser diode in a co-planar structure and the results show that minimizing the difference of distances between the different ridges and the n-electrode and increasing the electrical conductivity of the n-type GaN are two effective ways to improve the uniformity of carrier distribution in emitter stripes. Two pairs of emitters on a chip are arranged to be located near the two n-electrode pads on the left and right sides, and the four stripe emitters can laser together. The laser diode shows two sharp peaks of light output at 408 and 409 nm above the threshold current. The full widths at half maximum for the parallel and perpendicular far field patterns are 8 degrees and 32 degrees, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An extended subtraction method of scattering parameters for characterizing laser diode is introduced in this paper. The intrinsic small-signal response can be directly extracted from the measured transmission coefficients of laser diode by the method. However the chip temperature may change with the injection bias current due to thermal effects, which causes inaccurate intrinsic response by our method. Therefore, how to determine the chip temperature and keep the laser chip adiabatic is very critical when extracting the intrinsic response. To tackle these problems, the dependence of the lasing wavelength of the laser diode on the chip temperature is investigated, and an applicable measurement setup which keeps the chip temperature stable is presented. The scattering parameters of laser diode are measured on diabatic and adiabatic conditions, and the extracted intrinsic responses for both conditions are compared. It is found that the adiabatic intrinsic responses are evidently superior to those without thermal consideration. The analysis indicates that inclusion of thermal effects is necessary to acquire accurate intrinsic response.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study reports a subretinal implant device which can imitate the function of photoreceptor cells. Photodiode (PD) arrays on the chip translate the incident light into current according to the intensity of light. With an electrode at the end of every photodiode, the PDs transfer the current to the remnant healthy visual cells such as bipolar cells and horizontal cells and then activate these cells. Biocompatible character of the materials and artificial photoreceptor itself were tested and the photoelectric characteristics of the chips in simulative condition were described and discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel design of 100GHz-spaced 16channel arrayed-waveguide grating (AWG) based on silica-on-silicon chip is reported.AWG is achieved by adding a Y-branch to the AWG and arranging the input/output channel in a neat row,so the whole configuration can be aligned and packaged using only one fiber-array.This configuration can decrease the device's size,enlarge the minimum radius of curvature,save time on polishing and alignment,and reduce the chip's fabrication cost.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To improve the sensitivity of our laser radar system, we provided a set of control method for APDs (Avalanched Photodiodes) based on single-chip computer together with the circuits dealing with noise and temperature. It adjusts the voltages intelligently and maintains the APD's optimal working status.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

液滴操纵和控制是实现微全分析系统(μTAS)和芯片上的实验室(lab-on-a-chip)功能的基础,基于液滴操控的显示及微透镜已经成功应用。目前电润湿启动液滴方法简单、响应时间快,引起越来越多的关注。另一方面超疏水表面上的液滴具有低摩擦、低粘附的特性,借由这种原理制作的微流器件可以实现微量液体传输。为了更好的利用超疏水表面的特性,就需要研究液滴运动规律,以及表面特性的影响。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

为了改进现有防伪数码相机不能处理通过翻拍伪造数码照片的缺陷,提出了一种新的基于安全芯片的防伪数码相机架构。在拍摄时将所拍摄的区域分成多个小单元,并用对焦测距系统测量各个单元到相机的距离。用安全芯片对图像元数据、图像内容及距离信息进行数字签名,并将签名内容及距离信息都保存在图像文件的元数据里。通过验证数字签名有效且距离信息不完全相等来保证图片的真实可信。该防伪数码相机能同时发现照片在拍摄后被篡改和翻拍问题,所拍摄照片真实可信。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent advances and key strategies in capillary electrophoresis and microchip CE with electrochemical detection (ECD) and electrochemiluminescence (ECL) detection are reviewed. This article consists of four main parts: CE-ECD; microchip CE-ECD; CE-ECL; and microchip CE-ECL. It is expected that ECD and ECL will become powerful tools for CE microchip systems and will lead to the creation of truly disposable devices. The focus is on papers published in the last two years (from 2005 to 2006).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As a high efficiency separation technique, capillary electrophoresis(CE) has been widely used in various fields of analytical science. Amperometry is one of the most sensitive electrochemical detection methods in CE. The capillary/electrode decoupling mechanism, applications,of new electrode systems in CE, detection cell technique are discussed in detail. Amperometric detection is compatible with microfabricated CE chips and will make the concept of lab-on-a-chip become a reality. Because of these progresses, amperometry is becoming a widely acceptable detection method,for more chemical and biological analytes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the development of a mini-electrochemical detector for microchip electrophoresis. The small size (3.6 x 5.0 cm(2), W x L) of the detector is compatible with the dimension of the microchip. The use of universal serial bus (USB) ports facilitates installation and use of the detector, miniaturizes the detector, and makes it ideal for lab-on-a-chip applications. A fixed 10 M Omega feedback resistance was chosen to convert current of the working electrode to voltage with second gain of 1, 2, 4, 8, 16, 32, 64 and 128 for small signal detection instead of adopting selectable feedback resistance. Special attention has been paid to the power support circuitry and printed circuit board (PCB) design in order to obtain good performance in such a miniature size. The working electrode potential could be varied over a range of +/-2.5 V with a resolution of 0.01 mV. The detection current ranges from -0.3 x 10(-7) A to 2.5 x 10(-7) A and the noise is lower than 1 pA. The analytical performance of the new system was demonstrated by the detection of epinephrine using an integrated PDMS/glass microchip with detection limit of 2.1 mu M (S/N = 3).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present theoretical, numerical, and experimental analyses on the non-linear dynamic behavior of superparamagnetic beads exposed to a periodic array of micro-magnets and an external rotating field. The agreement between theoretical and experimental results revealed that non-linear magnetic forcing dynamics are responsible for transitions between phase-locked orbits, sub-harmonic orbits, and closed orbits, representing different mobility regimes of colloidal beads. These results suggest that the non-linear behavior can be exploited to construct a novel colloidal separation device that can achieve effectively infinite separation resolution for different types of beads, by exploiting minor differences in their bead's properties. We also identify a unique set of initial conditions, which we denote the "devil's gate" which can be used to expeditiously identify the full range of mobility for a given bead type.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The advent of digital microfluidic lab-on-a-chip (LoC) technology offers a platform for developing diagnostic applications with the advantages of portability, reduction of the volumes of the sample and reagents, faster analysis times, increased automation, low power consumption, compatibility with mass manufacturing, and high throughput. Moreover, digital microfluidics is being applied in other areas such as airborne chemical detection, DNA sequencing by synthesis, and tissue engineering. In most diagnostic and chemical-detection applications, a key challenge is the preparation of the analyte for presentation to the on-chip detection system. Thus, in diagnostics, raw physiological samples must be introduced onto the chip and then further processed by lysing blood cells and extracting DNA. For massively parallel DNA sequencing, sample preparation can be performed off chip, but the synthesis steps must be performed in a sequential on-chip format by automated control of buffers and nucleotides to extend the read lengths of DNA fragments. In airborne particulate-sampling applications, the sample collection from an air stream must be integrated into the LoC analytical component, which requires a collection droplet to scan an exposed impacted surface after its introduction into a closed analytical section. Finally, in tissue-engineering applications, the challenge for LoC technology is to build high-resolution (less than 10 microns) 3D tissue constructs with embedded cells and growth factors by manipulating and maintaining live cells in the chip platform. This article discusses these applications and their implementation in digital-microfluidic LoC platforms. © 2007 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

cERMIT is a computationally efficient motif discovery tool based on analyzing genome-wide quantitative regulatory evidence. Instead of pre-selecting promising candidate sequences, it utilizes information across all sequence regions to search for high-scoring motifs. We apply cERMIT on a range of direct binding and overexpression datasets; it substantially outperforms state-of-the-art approaches on curated ChIP-chip datasets, and easily scales to current mammalian ChIP-seq experiments with data on thousands of non-coding regions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The curing of a thermosetting polymer materials utilized on micro-electronics packaging applications can be performed using microwave systems. The use of microwave energy enables the cure process to be completed more rapidly than with alternative approaches due to the ability to heat volumetrically. Furthermore, advanced dual-section microwave systems enable curing of individual components on a chip-on-board assembly. The dielectric properties of thermosetting polymer materials, commonly used in microelectronics packaging applications, vary significantly with temperature and degree of cure. The heating rate within a material subjected to an electric field is primarily dependant on the dielectric loss properties of the material itself. This article examines the variation in dielectric properties of a commercially available encapsulant paste with frequency and temperature and the resulting influence on the cure process. The 'FAMOBS' dual section microwave system and its application to microelectronics manufacture are described. The measurement of the dielectric properties of 'Henkel EO1080' encapsulant paste uses a commercially available 'dielectric probe kit' and is described in this paper. The FAMOBS heating system is used to encapsulate a small op-amp chip. A numerical model formulated to assess the cure process in thermosetting polymer materials under microwave heating is outlined. Numerical results showing that the microwave processing systems is capable of rapidly and evenly curing thermosetting polymer materials are presented.