993 resultados para foramen of Huschke


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have conducted a systematic review of air embolism complications of neurosurgery in the sitting position and patent foramen ovale (PFO) closure. It assesses the risk and benefit of PFO closure before neurosurgery in the sitting position. The databases Medline, Embase, and Cochrane Controlled Trial Register were systematically searched from inception to November 2007 for keywords in both topics separately. In total, 4806 patients were considered for neurosurgery in sitting position and 5416 patients underwent percutaneous PFO closure. The overall rate of venous air embolism during neurosurgery in sitting position was 39% for posterior fossa surgery and 12% for cervical surgery. The rate of clinical and transoesophageal echocardiography detected paradoxical air embolism was reported between 0% and 14%. The overall success rate for PFO closure using new and the most common closure devices was reported 99%, whereas the average risk of major complications is <1%. On the basis of our systematic review, we recommend screening for PFO and considering closure in cases in which the sitting position is the preferred neurosurgical approach. Our proposed management including the time of PFO closure according to available data is presented. However, the conclusions from our systematic review may be limited due to the lack of level A evidence and from using data from observational cohort studies. Thus, definite evidence-based recommendations require prospective evaluation of the issue in well-designed studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the growing recognition of the patent foramen ovale (PFO), particularly when associated with an atrial septal aneurysm, as risk factor for several disease manifestations (above all paradoxical embolism), the optimal treatment strategy for symptomatic patients remains controversial. Percutaneous PFO closure is a minimally invasive procedure which can be performed with high success and low morbidity. For secondary prevention of recurrent embolic events, it appears to be clinically at least as effective as oral anticoagulation. Ventricular septal defects (VSDs) are the most common congenital heart defects. Percutaneous VSD closure is more intricate than PFO closure. It is associated with a significant risk of both peri-interventional and mid-term complications. In suitable patients with congenital VSD, device closure may well be the preferred treatment both for muscular or perimembranous VSDs and for residual defects after surgical VSD closure. The risk of complete atrioventricular conduction block remains a concern in the perimembranous group. The history, technique and clinical role of percutaneous PFO and VSD closure are discussed, with emphasis on current problems and future developments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To assess feasibility and outcomes of left atrial appendage (LAA) closure when using a patent foramen ovale (PFO) for left atrial access. Background: Because of the fear of entering the left atrium too high, using a PFO for left atrial access during LAA occlusion (LAAO) is generally discouraged. We report our single-center experience using a concomitant PFO for LAAO, thereby avoiding transseptal puncture. METHODS: LAAO was performed with local anesthesia and fluoroscopic guidance only (no echocardiography). The Amplatzer Cardiac Plug (ACP) was used in all patients. After LAAO, the PFO was closed at the same sitting, using an Amplatzer occluder through the ACP delivery sheath. Patients were discharged the same or the following day on dual antiplatelet therapy for 1-6 months, at which time a follow-up transesophageal echocardiogram (TEE) was performed. RESULTS: In 49 (96%) of 51 patients (35 males, age 70.9 ± 11.9 years), LAAO was successful using the PFO for left atrial access. In one patient, a long tunnel PFO precluded LAAO, which was performed via a more caudal transseptal puncture. In a second patient, a previously inserted ASD occluder precluded LAAO, which was abandoned because of pericardial bleeding. PFO closure was successful in all patients. Follow-up TEE was performed in 43 patients 138 ± 34 days after the procedure. It showed proper sitting of both devices in all patients. CONCLUSIONS: Using a PFO for LAAO had a high success rate and could be the default access in all patients with a PFO, potentially reducing procedural complications arising from transseptal puncture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 34-year-old male patient was referred for primary percutaneous coronary intervention for ST-segment elevation myocardial infarction with cardiogenic shock and was found to have embolic left coronary artery occlusion and subsegmental pulmonary artery emboli as a consequence of venous thrombosis to trauma to the thigh in the presence of a patent foramen ovale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Multidetector computed tomography (MDCT) may be useful to identify patients with patent foramen ovale (PFO). The aim of this study was to analyze whether a MDCT performed before pulmonary vein isolation reliably detects a PFO that may be used for access to the left atrium. METHODS AND RESULTS In 79 consecutive patients, who were referred for catheter ablation of symptomatic paroxysmal or persistent atrial fibrillation (AF), the presence of a PFO was explored by MDCT and transesophageal echocardiography (TEE). TEE was considered as the gold standard, and quality of TEE was good in all patients. In 16 patients (20.3%), MDCT could not be used for analysis because of artifacts, mainly because of AF. On TEE, a PFO was found in 15 (23.8%) of the 63 patients with usable MDCT. MDCT detected six PFO of which four were present on TEE. This corresponded to a sensitivity of 26.7%, a specificity of 95.8%, a negative predictive value of 80.7%, and a positive predictive value of 66.7%. The receiver operating characteristics curve of MDCT for the detection of PFO was 0.613 (95% confidence interval 0.493-0.732). CONCLUSIONS MDCT may detect a PFO before pulmonary isolation. However, presence of AF may lead to artifacts on MDCT impeding a meaningful analysis. Furthermore, in this study sensitivity and positive predictive value of MDCT were low and therefore MDCT was not a reliable screening tool for detection of PFO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE We aimed to create an index to stratify cryptogenic stroke (CS) patients with patent foramen ovale (PFO) by their likelihood that the stroke was related to their PFO. METHODS Using data from 12 component studies, we used generalized linear mixed models to predict the presence of PFO among patients with CS, and derive a simple index to stratify patients with CS. We estimated the stratum-specific PFO-attributable fraction and stratum-specific stroke/TIA recurrence rates. RESULTS Variables associated with a PFO in CS patients included younger age, the presence of a cortical stroke on neuroimaging, and the absence of these factors: diabetes, hypertension, smoking, and prior stroke or TIA. The 10-point Risk of Paradoxical Embolism score is calculated from these variables so that the youngest patients with superficial strokes and without vascular risk factors have the highest score. PFO prevalence increased from 23% (95% confidence interval [CI]: 19%-26%) in those with 0 to 3 points to 73% (95% CI: 66%-79%) in those with 9 or 10 points, corresponding to attributable fraction estimates of approximately 0% to 90%. Kaplan-Meier estimated stroke/TIA 2-year recurrence rates decreased from 20% (95% CI: 12%-28%) in the lowest Risk of Paradoxical Embolism score stratum to 2% (95% CI: 0%-4%) in the highest. CONCLUSION Clinical characteristics identify CS patients who vary markedly in PFO prevalence, reflecting clinically important variation in the probability that a discovered PFO is likely to be stroke-related vs incidental. Patients in strata more likely to have stroke-related PFOs have lower recurrence risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Patent foramen ovale (PFO) and cryptogenic stroke are commonly associated but some PFOs are incidental. Specific radiological findings associated with PFO may be more likely to indicate a PFO-related cause. We examined whether specific radiological findings are associated with PFO among subjects with cryptogenic stroke and known PFO status. METHODS We analyzed the Risk of Paradoxical Embolism(RoPE) Study database of subjects with cryptogenic stroke and known PFO status, for associations between PFO and: (1) index stroke seen on imaging, (2) index stroke size, (3) index stroke location, (4) multiple index strokes, and (5) prior stroke on baseline imaging. We also compared imaging with purported high-risk echocardiographic features. RESULTS Subjects (N=2680) were significantly more likely to have a PFO if their index stroke was large (odds ratio [OR], 1.36; P=0.0025), seen on index imaging (OR, 1.53; P=0.003), and superficially located (OR, 1.54; P<0.0001). A prior stroke on baseline imaging was associated with not having a PFO (OR, 0.66; P<0.0001). Finding multiple index strokes was unrelated to PFO status (OR, 1.21; P=0.161). No echocardiographic variables were related to PFO status. CONCLUSIONS This is the largest study to report the radiological characteristics of patients with cryptogenic stroke and known PFO status. Strokes that were large, radiologically apparent, superficially located, or unassociated with prior radiological infarcts were more likely to be PFO-associated than were unapparent, smaller, or deep strokes, and those accompanied by chronic infarcts. There was no association between PFO and multiple acute strokes nor between specific echocardiographic PFO features with neuroimaging findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The etiology of feline dental resorptive lesions is unknown, but some evidence suggests that interactions between components of the periodontium may be initiating factors in the development of these lesions. In the present study, 22 clinically normal teeth were harvested from 7 cats. The teeth and periodontium were radiographed and examined histologically. In addition, 14 of the 22 teeth were examined histometrically. Two teeth were histologically normal with an open apical foramen and two were normal with a closed apical foramen. Histological evidence of periodontal ligament degeneration without cementum resorption was observed in 8 teeth, and varying degrees of cementum resorption were observed in 10 teeth. Mandibular molar and premolar teeth had distal drift, and mandibular canine teeth had mesial drift. Alterations in the periodontal ligament may represent a preclinical stage of dental resorption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To compare clinical outcome of Amplatzer PFO (APFO) to Cardia PFO (CPFO) occluder. Percutaneous patent foramen ovale (PFO) closure prevents stroke recurrence in stroke due to paradoxical embolism. Methods and results: The primary endpoint was a composite of stroke, TIA, or peripheral embolism at follow-up. The secondary endpoint was residual shunt. Outcome was compared among 934 (APFO: 712; CPFO: 222) patients, and in 297 propensity score-matched patients. The primary endpoint occurred in 29 patients (0.71/100 patient-years): four (2%) with the CPFO (0.31/100 patient-years), and 25 (4%) with the APFO (0.89/100 patient-years) (p=0.20). Residual shunt at six months was more frequent with the CPFO (31% versus 9%, p<0.001). No differences in residual shunts were seen at the last available echocardiographic follow-up (9±18 months): APFO 11%, CPFO 14%, p=0.22. Conclusions: This study suggests that PFO closure with APFO or CPFO is equally effective for the prevention of recurrent events. Residual shunt was more frequent at six months with CPFO, but was similar to APFO at later follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE For dental implant treatment planning and placement, a precise anatomic description of the nasopalatine canal (NC) is necessary. This descriptive retrospective study evaluated dimensions of the NC and buccal bone plate (BBP) and the tridimensional association of the anatomic variants of NC, using cone-beam computed tomography (CBCT). METHODS This study included 230 CBCTs. Sagittal slices were used for measurements of the NC and BBP and to evaluate shape and direction-course of the NC. Coronal slices were used to assess NC shape and axial slices to assess number of incisive foramina and foramina of Stenson. RESULTS Mean NC length was 12.34 ± 2.79 mm, statistically significant differences were detected between genders (p < 0.001). Mean BBP length was 20.87 ± 3.68 mm, statistically significant differences were found for the dental status (p < 0.001) and mean BBP width was 6.83 ± 1.28 mm, significant differences were detected between genders (p < 0.001). Mean nasopalatine angle was 73.33° ± 8.11°, significant differences were found in sagittal and coronal classifications. The most prevalent canal was: cylindrical sagittal shape (48.2 %); slanted-straight direction-course (57.6 %); Ya-type coronal shape (42.4 %); and one foramen incisive with two Stenson's foramina (1-2) (50.9 %). Sagittal shape was associated with sagittal direction-course (p < 0.001). Coronal shape was associated with axial classification (p < 0.001). CONCLUSIONS The NC anatomy is highly variable. Gender is related to the NC length and BBP width, while dental status is related to BBP length. There was an association between the different sagittal classifications of the NC and between the coronal shape and axial classification.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Concurrent cardiac diseases are frequent among elderly patients and invite simultaneous treatment to ensure an overall favourable patient outcome. Aim To investigate the feasibility of combined single-session percutaneous cardiac interventions in the era of transcatheter aortic valve implantation (TAVI). Methods This prospective, case–control study included 10 consecutive patients treated with TAVI, left atrial appendage occlusion and percutaneous coronary interventions. Some in addition had patent foramen ovale or atrial septal defect closure in the same session. The patients were matched in a 1:10 manner with TAVI-only cases treated within the same time period at the same institution regarding their baseline factors. The outcome was validated according to the Valve Academic Research Consortium (VARC) criteria. Results Procedural time (126±42 vs 83±40 min, p=0.0016), radiation time (34±8 vs 22±12 min, p=0.0001) and contrast dye (397±89 vs 250±105 mL, p<0.0001) were higher in the combined intervention group than in the TAVI-only group. Despite these drawbacks, no difference in the VARC endpoints was evident during the in-hospital period and after 30 days (VARC combined safety endpoint 32% for TAVI only and 20% for combined intervention, p=1.0). Conclusions Transcatheter treatment of combined cardiac diseases is feasible even in a single session in a high-volume centre with experienced operators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proof that percutaneous closure of the patent foramen ovale (PFO) is superior to medical treatment is still incomplete. Paradoxical embolism is a rare event occurring over decades rather than years. None of the 4 randomized trials published carried enough patients or was followed up for long enough to reach superiority endpoints. All data, however, point to a benefit of PFO closure. Free wall erosion (exceedingly rare) and triggering of atrial fibrillation (in about 1% of patients) are the only noteworthy complications. They are outweighed by the supposedly prevented events of paradoxical embolisms, such as stroke, transient ischemic attacks, myocardial infarctions, or other systemic embolisms. Medical treatment with perhaps the exception of lifelong oral anticoagulation provides less protection. During a 10-year follow-up of a comparative study the annual mortality was significantly lower in the patients with PFO closure (0.4%) than in those with medical treatment (1.1%, P < 0.03). PFO closure can be accomplished in less than 1 hour with immediate resumption of physical activity. It represents thus a kind of mechanical vaccination.