950 resultados para X-rays.


Relevância:

70.00% 70.00%

Publicador:

Resumo:

We present high time-resolution multiwavelength observations of X-ray bursts in the low-mass X-ray binary UY Vol. Strong reprocessed signals are present in the ultraviolet and optical, lagged and smeared with respect to the X-rays. The addition of far-ultraviolet coverage for one burst allows much tighter constraints on the temperature and geometry of the reprocessing region than previously possible. A blackbody reprocessing model for this burst suggests a rise in temperatures during the burst from 18,000 to 35,000 K and an emitting area comparable to that expected for the disk and/or irradiated companion star. The lags are consistent with those expected. The single-zone blackbody model cannot reproduce the ratio of optical to ultraviolet flux during the burst, however. The discrepancy seems too large to explain with deviations from a local blackbody spectrum and more likely indicates that a range of reprocessing temperatures are required. Comparable results are derived from other bursts, and in particular the lag and smearing both appear shorter when the companion star is on the near side of the disk as predicted. The burst observed by HST also yielded a spectrum of the reprocessed light. It is dominated by continuum, with a spectral shape consistent with the temperatures derived from lightcurve modeling. Taken as a whole, our observations confirm the standard paradigm of prompt reprocessing distributed across the disk and companion star, with the response dominated by a thermalized continuum rather than by emission lines.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90 degrees, measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study presents a comparison of the X-ray transmission through microsized and nanosized materials. For this purpose CuO nanoparticles, with 13.4 nm average grain size, and CuO microparticles, with a mean particle size of 56 mu m, were incorporated separately to beeswax in a concentration of 5%. Results show that the transmission through the above material plates with microsized and nanosized CuO was almost the same for X-ray beams generated at 60 and 102 kV tube voltages. However, for the radiation beams generated at 26 and 30 kV tube voltages the X-rays are more attenuated by the nanostructured CuO plates by a factor of at least 14%. Results suggest that the difference in the low energy range may be due to the higher number of particles/gram in the plates designed with CuO nanoparticles and due to the grain size effect on the X-ray transmission. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, alpha) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We describe how the method of detection of delayed K x-rays produced by the electron capture decay of the residual nuclei can be a powerful tool in the investigation of the effect of the breakup process on the complete fusion (CF) cross-section of weakly bound nuclei at energies close to the Coulomb barrier. This is presently one of the most interesting subjects under investigation in the field of low-energy nuclear reactions, and the difficult experimental task of separating CF from the incomplete fusion (ICF) of one of the breakup fragments can be achieved by the x-ray spectrometry method. We present results for the fusion of the (9)Be + (144)Sm system. Copyright (c) 2008 John Wiley & Sons, Ltd.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz`min energy threshold, 6 x 10(19) eV. The anisotropy was measured by the fraction of arrival directions that are less than 3.1 degrees from the position of an active galactic nucleus within 75 Mpc (using the Veron-Cetty and Veron 12th catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (38(-6)(+7))%, compared with 21% expected for isotropic cosmic rays. This is down from the early estimate of (69-(+11)(13))%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work we compare and contrast the stability of retained austenite during tensile testing of Nb-Mo-Al transformation-induced plasticity steel subjected to different thermomechanical processing schedules. The obtained microstructures were characterised using optical metallography, transmission electron microscopy and X-ray diffraction. The transformation of retained austenite to martensite under tensile loading was observed by in-situ high energy X-ray diffraction at 1ID / APS. It has been shown that the variations in the microstructure of the steel, such as volume fractions of present phases, their morphology and dimensions, play a critical role in the strain-induced transition of retained austenite to martensite.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

High-brightness synchrotron X-rays together with precision achromatic focusing optics on beamline 7.3.3 at the Advanced Light Source have been applied for Laue microdiffraction analysis of mineralogical phases in Egyptian pigments. Although this task is usually performed using monochromatic X-ray diffraction, the Laue technique was both faster and more reliable for the present sample. In this approach, white-beam diffraction patterns are collected as the sample is raster scanned across the incident beam (0.8 µm × 0.8 µm). The complex Laue diffraction patterns arising from illumination of multiple grains are indexed using the white-beam crystallographic software package XMAS, enabling a mineralogical map as a function of sample position. This methodology has been applied to determine the mineralogy of colour pigments taken from the ancient Egyptian coffin of Tjeseb, a priestess of the Apis bull dating from the Third Intermediate to Late period, 25th Dynasty to early 26th Dynasty (747 to 600 BC). For all pigments, a ground layer of calcite and quartz was identified. For the blue pigment, cuprorivaite (CuCaSi4O10) was found to be the primary colouring agent with a grain size ranging from ∼10 to 50 µm. In the green and yellow samples, malachite [Cu2(OH)2CO3] and goethite [FeO(OH)] were identified, respectively. Grain sizes from these pigments were significantly smaller. It was possible to index some malachite grains up to ∼20 µm in size, while the majority of goethite grains displayed a nanocrystalline particle size. The inability to obtain a complete mineralogical map for goethite highlights the fact that the incident probe size is considerably larger than the grain size. This limit will continue to improve as the present trend is toward focusing optics approaching the diffraction limit (∼1000× smaller beam area).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This work main objective is to study the use of bricks in barium X-rays rooms in order to contribute to the optimization of shielding rooms diagnosis. The work was based on experimental measurements of X-ray attenuation (40 to 150 kV), using ceramic seal bearing the incorporation of barium sulfat (BaSO4). Different formulations were studied in three different firing temperatures and evaluated for incorporation in the ceramic body. The composition of 20% of barite processed at a temperature of 950 ° C showed better physical and mechanical properties, is considered the most suitable for the purpose of this work. Were produced bricks sealing composition formulated based on that presented the best technological features. These blocks were tested physically as a building material and wall protective barrier. Properties such as visual, deviation from the square, face flatness, water absorption and compressive strength were evaluated for all the blocks produced. The behavior of this material as attenuator for X-rays was investigated by experimental results which take into account mortar manufacturers barium through the different strains and compared with the reference material (Pb). The simulation results indicated that the ceramic block barium shows excellent properties of attenuation equivalence lead taking into account the energy used in diagnostic X-ray

Relevância:

70.00% 70.00%

Publicador:

Resumo:

X-rays were initially used for the inspection of special-purpose wood pieces for quantitative evaluation properties of different species. X-ray densitometry has had its use expanded ill dendroclimatology of Picea engelmannii trees. Subsequent laboratories developed applications of X-ray densitometry for environmental, wood science and technology, and related areas. This paper describes the basic methodology of X-ray densitometry applied to the eucalypt wood analysis, as well its presenting the results of applications in three areas: (i) evaluation of wood biodegradation by white rot fungi, (ii) detection of sapwood and heartwood, and (iii) determination of the effect of management oil wood properties. The wood decayed by white rot fungi was detected by X-ray densitometry with it decreasing wood density due to the biodegradation of cell wall components. The sapwood and heartwood of eucalypts were separated in response to the attenuation of X-rays, reflected by the wood anatomical structure and chemical composition. Also, Ill eucalypt trees after the application of irrigation and i characteristic wood density profiles were detected. Ill addition, the significant potential of X-ray densitometry for eucalypt wood research and analysis is discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

No presente trabalho, objetivou-se avaliar os efeitos da dessecação e identificar lesões por predação por insetos, em diásporos de canela-batalha (Cryptocarya aschersoniana Mez.), utilizando-se testes de raios X. Os danos provocados pela dessecação foram dimensionados nas imagens e associados à formação de plântulas. Diásporos recém-beneficiados (45 % de umidade e 37 % de germinação) foram colocados para secar em sala climatizada (20 ºC e 60 % UR), dentro de bandejas plásticas em camada única. Posteriormente, com o intuito de acelerar o processo de secagem, foram colocados em caixas de secagem com solução saturada de hidróxido de sódio (28 % UR) e amostrados com 45, 37, 35, 31 e 26 % de umidade. Para as radiografias, utilizou-se a intensidade de radiação de 40 kVp e tempo de exposição de 1,5 minutos. Posteriormente, as radiografias foram fotografadas e as imagens analisadas em computador, sendo medido o afastamento entre o endocarpo e a semente. As sementes foram classificadas em sementes intactas, sementes com afastamento parcial, sementes com afastamento total e sementes predadas. Os testes de germinação foram realizados sobre areia, em germinadores tipo Mangelsdorf a 25 ºC e luz branca constante. Pelos resultados, observa-se que a germinação é comprometida quando o teor de água das sementes fica abaixo de 26 %. Nesse ponto, o afastamento entre o endocarpo e a semente é de 0,65 mm. Houve uma correlação positiva entre a viabilidade das sementes, avaliada pelo teste de germinação, e o afastamento entre o endocarpo e a semente observado nas radiografias. A análise radiográfica possibilita identificar danos provocados por predação após infestação por insetos.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: the failure of osseointegration in oral rehabilitation has gained importance in current literature and in clinical practice. The integration of titanium dental implants in alveolar bone has been partly ascribed to the biocompatibility of the implant surface oxide layer. The aim of this investigation was to analyze the surface topography and composition of failed titanium dental implants in order to determine possible causes of failure.Methods: Twenty-one commercially pure titanium (cpTi) implants were retrieved from 16 patients (mean age of 50.33 +/- 11.81 years). Fourteen implants were retrieved before loading (early failures), six after loading (late failures), and one because of mandibular canal damage. The failure criterion was lack of osseointegration characterized as dental implant mobility. Two unused implants were used as a control group. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) to element analysis. Evaluations were performed on several locations of the same implant.Results: SEM showed that the surface of all retrieved implants consisted of different degrees of organic residues, appearing mainly as dark stains. The surface topography presented as grooves and ridges along the machined surface similar to control group. Overall, foreign elements such as carbon, oxygen, sodium, calcium, silicon, and aluminum were detected in failed implants. The implants from control group presented no macroscopic contamination and clear signs of titanium.Conclusion: These preliminary results do not suggest any material-related cause for implant failures, although different element composition was assessed between failed implants and control implants.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Large single crystals have been obtained of S-III-SPIII, a phospholipase A(2) from the venom of Bothrops jararacussu. The crystals belong to the orthorhombic system space group C222, and diffract X-rays to a resolution of 1.9 Angstrom. Preliminary analysis reveals the presence of one molecule in the crystallographic asymmetric unit. The crystal structure is currently being determined using molecular replacement techniques.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BnSP-6 (myotoxin I) is a phospholipase A2 homologue isolated from Bothrops neuwiedi pauloensis venom. Crystals of BnSP-6 were obtained which diffracted X-rays to 2.5 Angstrom resolution using a synchrotron radiation source at room temperature and belong to space group P3(1)21. The unit cell dimensions are a=b=57.7, c=131.1 Angstrom. The structure was solved by molecular replacement using the coordinates of bothropstoxin I from B. jararacussu venom. There are two molecules in the asymmetric unit.