988 resultados para Third space


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of parameter-space size adjustment is pn,posed in order to enable successful application of genetic algorithms to continuous optimization problems. Performance of genetic algorithms with six different combinations of selection and reproduction mechanisms, with and without parameter-space size adjustment, were severely tested on eleven multiminima test functions. An algorithm with the best performance was employed for the determination of the model parameters of the optical constants of Pt, Ni and Cr.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endoscopic third ventriculostomy (ETV) has been established as an effective method in the treatment of tumoral obstructive hydrocephalus. Delayed closure of the ETV stoma has been attributed to scarring involving the third ventricular floor. Secondary obstruction of the stoma due to intraventricular tumor seeding is an extremely rare condition, with only one case described to date. The authors report on a unique case of late closure of the ETV stoma caused by metastatic seeding of a recurrent medulloblastoma 9 years after the initial treatment. The patient was submitted to a second endoscopic procedure in which a reddish mass located just at the third ventricular floor was resected, leading to reopening of the previous ETV stoma. To the best of the authors` knowledge, this case is the first report of an ETV obstruction due to metastatic CSF seeding of a medulloblastoma. In such cases of late failure of the ETV stoma because of tumor obstruction, a second ETV can be safely performed and lead to adequate function of the stoma, even if limited by the aggressive nature of the disease. (DOI: 10.3171/2010.1.PEDS09320)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: One of the key elements for a successful endoscopic intervention in the ventricular system is the ability to recognize the anatomic structures and use them as a reference. OBJECTIVE: To measure the choroid plexus with endoscopy in the interventricular foramen, together with the structures on the third ventricle floor, and to compare these variables. METHODS: An observational prospective study was carried out on 37 brains of cadavers for which the cause of death was assessed at the Death Check Unit of the University of Sao Paulo in April 2008. This study was done on adults of both sexes with a rigid neuroendoscope. Endoscopic images were recorded, submitted for correction of distortion, and then measured. RESULTS: The measurements of the choroid plexus in the interventricular foramen, laterolateral distance of mammillary bodies, distance from the infundibular recess to the mammillary bodies, and area of the triangle in the tuber cinereum were 1.71 +/- 0.77 mm, 2.23 +/- 0.74 mm, 3.22 +/- 0.82 mm, and 3.69 +/- 2.09 mm(2), respectively. The ventricle floor was opaque in 84% of cases. The internal distance of mammillary bodies was absent in 89%. Associations between the translucent floor of the third ventricle and laterolateral distance of mammillary bodies, internal distance of mammillary bodies, and age were identified. CONCLUSION: Before this research, there was no record of the measurements of the choroid plexus in the interventricular foramen. The remaining variables of the present study show a greater number in normal brains compared with others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the use of orbital polyacrylamide gel injection for the correction of anophthalmic enophthalmos. Methods: Noncontrolled clinical trial of 21 patients (14 with ocular implants, 5 with phthisis bulbi, and 2 with dermis-fat graft). Orbital CT was performed to estimate the volume of polyacrylamide gel needed to restore orbital volume. Polyacrylamide gel was injected using a 22-gauge (30 x 0.7 min) needle transcutaneously inserted in the lateral third of the lower eyelid, directed to the orbital muscle cone. A second injection was administered 15 days later. if necessary. CT was repeated 30 days after the last procedure. Exophthalmometry was performed before Bind 90 days after file procedure. Results: The mean total volume injected per orbit was 2.4 +/- 0.7 ml (range 1-3.5 ml). The volume of the enophthalmic orbit increased front 26.9 +/- 5.0 ml to 29.3 +/- 4.9 ml (p < 0.001). The mean difference in exophthalmometry readings was 3.3 +/- 1.6 mm (range, 1.5-8.0 mm) before the procedure and 1.0 +/- 0.9 mm (range, 0.0-3.0 mm) after 3 months (p < 0.001). Adjustment of the ocular prosthesis or fabrication of a new one was necessary in 11 patients (52.4%), and the mean volume of the ocular prosthesis was reduced front 2.0 +/- 0.6 ml to 1.6 +/- 0.6 ml (p = 0.003). All patients were satisfied with the aesthetic results. No serious adverse events were observed. The initial results were maintained 1 year after the procedure. Conclusions: Polyacrylamide gel injection in the orbital space effectively reduces enophthalmos in ocular prosthesis wearers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selected as part of an anthology featuring best or most representative of 20th century art writing. Other authors in anthology included Benjamin, Greenberg, Krauss, T.j. Clark, Roger Fry, Stuart Hall, etc. Intended as US textbook. My essay featured as part of study day on globalism in art at Tate Modern. Essay itself subject of PhD thesis by Sally Butler of EMSAH and other subsequent commentaries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the influence of oral contraceptives (OCs) containing 20 mu mu g ethinylestradiol (EE) and 150 mu mu g gestodene (GEST) on the autonomic modulation of heart rate (HR) in women. Methods One-hundred and fifty-five women aged 24 +/-+/- 2 years were divided into four groups according to their physical activity and the use or not of an OC: active-OC, active-non-OC (NOC), sedentary-OC, and sedentary-NOC. The heart rate was registered in real time based on the electrocardiogram signal for 15 minutes, in the supine-position. The heart rate variability (HRV) was analysed using Shannon`s entropy (SE), conditional entropy (complexity index [CInd] and normalised CInd [NCI]), and symbolic analysis (0V%, 1V%, 2LV%, and 2ULV%). For statistical analysis the Kruskal-Wallis test with Dunn post hoc and the Wilcoxon test (p < 0.05 was considered significant) were applied. Results Treatment with this COC caused no significant changes in SE, CInd, NCI, or symbolic analysis in either active or sedentary groups. Active groups presented higher values for SE and 2ULV%, and lower values for 0V% when compared to sedentary groups (p < 0.05). Conclusion HRV patterns differed depending on life style; the non-linear method applied was highly reliable for identifying these changes. The use of OCs containing 20 mu mu g EE and 150 mu mu g GEST does not influence HR autonomic modulation.