921 resultados para Standard method


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it's more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The application of microwave radiation on the sample preparation has been expanding increasingly in areas involving decomposition by wet and dry roads, fusion, extraction, acceleration of chemical reactions, for example. Currently, the use of microwave ovens for analytical purposes are recognized for having excellent performance for organic and inorganic samples. In the international market there are several kinds of microwaves oven which adapt the varied purposes, however yet with elevated prices which incapacitate your use as routine equipment in laboratory. Thus, many researchers have been choosing for developing own projects of microwaves oven production or to use domestic oven for the laboratory, with or without adaptations. For the evaluation of the proposed method was used in the Kjeldahl methodology for determining total nitrogen in samples of crude protein, using a domestic microwave oven and a digester pot made up in TeflonTM and distillation by steam. Were made to adapt and characterization of a domestic microwave oven, the confeccion vessel digester and the metal support for the vessel. The accuracy of the proposed method was confirmed by comparison of two methods, the standard method for conventional heating and by the proposed method, with heating by microwave radiation through the calculated values of relative standard deviation analysis

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to present a systematized review of different methods used to evaluate the masticatory efficiency in conventional complete denture wearers. A survey was conducted in the databases PubMed, Scopus, and Cochrane, seeking scientific articles according to the previously selected terms: "Masticatory performance", "Masticatory efficiency" and "Chewing ability complete denture". Moreover, complementary studies have been carried out with library manual search/databases, which included studies related to different ways to assess masticatory efficiency, specifically as it related to conventional complete denture wearers. Forty three papers were selected to be used in the present review. Despite the wide variety of methodologies in the literature, the sieves method is currently considered the gold standard method to evaluation of conventional complete denture wearers masticatory efficiency, since it is the simplest, does not depend on specific devices (beyond the set of sieves), allows for a rational assessment, and it has been widely reproduced in various types of oral rehabilitation. More, the almond, as natural test food, and the optocal (made from the molding material Optosil), as artificial test food, are the most constantly employed test foods to evaluate masticatory efficiency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

One approach to verify the adequacy of estimation methods of reference evapotranspiration is the comparison with the Penman-Monteith method, recommended by the United Nations of Food and Agriculture Organization - FAO, as the standard method for estimating ET0. This study aimed to compare methods for estimating ET0, Makkink (MK), Hargreaves (HG) and Solar Radiation (RS), with Penman-Monteith (PM). For this purpose, we used daily data of global solar radiation, air temperature, relative humidity and wind speed for the year 2010, obtained through the automatic meteorological station, with latitude 18° 91' 66 S, longitude 48° 25' 05 W and altitude of 869m, at the National Institute of Meteorology situated in the Campus of Federal University of Uberlandia - MG, Brazil. Analysis of results for the period were carried out in daily basis, using regression analysis and considering the linear model y = ax, where the dependent variable was the method of Penman-Monteith and the independent, the estimation of ET0 by evaluated methods. Methodology was used to check the influence of standard deviation of daily ET0 in comparison of methods. The evaluation indicated that methods of Solar Radiation and Penman-Monteith cannot be compared, yet the method of Hargreaves indicates the most efficient adjustment to estimate ETo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Brucellosis remains as a public health concern worldwide. In domestic animals, the disease is characterized by reproductive disorders in male and female. Besides extensive use of serological tests and recent development of molecular biology techniques, microbiological culture of Brucella species is yet considered a “gold standardmethod for diagnosis. Here, semen of 335 bovine bulls was subjected simultaneously to microbiological culture in Brucella agar, Farrell media, and CITA media to evaluate comparatively the best selective media for isolation of Brucella sp. Among all 335 samples, B. abortus B19 strain was isolated from semen of five (1.49%) bulls using the three selective media. However, Farrell media was considered the best selective media for microbiological diagnosis, because of allowed isolation of B. abortus B19 strain from bull semen without bacterial commensal or fungal contamination of plates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate the influence of interdental spacing on the performance of proximal caries detection methods in primary molars. In addition, aspects related to temporary tooth separation with orthodontic separators were evaluated. The proximal spaces between the posterior primary teeth (n = 344) of 76 children (4-12 years old) were evaluated before and after temporary separation. Stainless steel strips with different standardized thicknesses were used to measure the presence of biological spacing and the spacing obtained after temporary separation with orthodontic rubber rings. First, the presence of proximal caries lesions was assessed by visual inspection, bitewing radiographs and a pen-type laser fluorescence device (DIAGNOdent pen). Visual inspection after temporary separation with separators was the reference standard method in checking the actual presence of caries. Multilevel analyses were performed considering different outcomes: the performance of the methods in detecting caries lesions and the spacing after temporary separation. The spacing did not influence the performance of the caries detection methods. The maximum spacing obtained with temporary tooth separation was 0.80 mm (mean +/- standard deviation = 0.46 +/- 0.13 mm). The temporary separation was more effective in the upper arch and less effective when an initial biological interdental spacing was present. The biological interdental spacing does not influence the performance of proximal caries detection methods in primary molars, and temporary tooth separation provides spacing narrower than 1.0 mm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Estimates of evapotranspiration on a local scale is important information for agricultural and hydrological practices. However, equations to estimate potential evapotranspiration based only on temperature data, which are simple to use, are usually less trustworthy than the Food and Agriculture Organization (FAO)Penman-Monteith standard method. The present work describes two correction procedures for potential evapotranspiration estimates by temperature, making the results more reliable. Initially, the standard FAO-Penman-Monteith method was evaluated with a complete climatologic data set for the period between 2002 and 2006. Then temperature-based estimates by Camargo and Jensen-Haise methods have been adjusted by error autocorrelation evaluated in biweekly and monthly periods. In a second adjustment, simple linear regression was applied. The adjusted equations have been validated with climatic data available for the Year 2001. Both proposed methodologies showed good agreement with the standard method indicating that the methodology can be used for local potential evapotranspiration estimates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: In chronic renal failure patients under hemodialysis (HD) treatment, the availability of simple, safe, and effective tools to assess body composition enables evaluation of body composition accurately, in spite of changes in body fluids that occur in dialysis therapy, thus contributing to planning and monitoring of nutritional treatment. We evaluated the performance of bioelectrical impedance analysis (BIA) and the skinfold thickness sum (SKF) to assess fat mass (FM) in chronic renal failure patients before (BHD) and after (AHD) HD, using air displacement plethysmography (ADP) as the standard method. Design: This single-center cross-sectional trial involved comparing the FM of 60 HD patients estimated BHD and AHD by BIA (multifrequential; 29 women, 31 men) and by SKF with those estimated by the reference method, ADP. Body fat-free mass (FFM) was also obtained by subtracting the total body fat from the individual total weight. Results: Mean estimated FM (kg [%]) observed by ADP BHD was 17.95 +/- 0.99 kg (30.11% +/- 1.30%), with a 95% confidence interval (CI) of 16.00 to 19.90 (27.56 to 32.66); mean estimated FM observed AHD was 17.92 +/- 1.11 kg (30.04% +/- 1.40%), with a 95% CI of 15.74 to 20.10 (27.28 to 32.79). Neither study period showed a difference in FM and FFM (for both kg and %) estimates by the SKF method when compared with ADP; however, the BIA underestimated the FM and overestimated the FFM (for both kg and %) when compared with ADP. Conclusion: The SKF, but not the BIA, method showed results similar to ADP and can be considered adequate for FM evaluation in HD patients. (C) 2012 by the National Kidney Foundation, Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

No presente trabalho, foram comparados dois métodos de extração de cobre (Cu) e zinco (Zn) em solos com teor de matéria orgânica (MO) maior que 50g kg-1. Os métodos de extração comparados foram: Extração com HCl 0,1mol L-1 (método padrão para os estados do Rio Grande do Sul e Santa Catarina) e Mehlich 3. Este trabalho foi realizado no Laboratório de Química e Fertilidade do Solo da Universidade do Estado de Santa Catarina (UDESC), no ano de 2009. As duas metodologias de extração foram aplicadas em 286 amostras de solo provenientes do Laboratório de Análise do Solo da UDESC, todas com mais de 50g kg-1 de MO. Os teores de cobre e zinco nos extratos foram determinados por espectrometria de absorção atômica com chama. Os resultados mostraram que houve correlação significativa entre os métodos, Cu (r=0,80) e Zn (r=0,93). A solução de Mehlich 3 extraiu mais cobre e menos zinco, quando comparada à solução de HCl 0,1mol L-1. O Mehlich 3 demonstrou ser eficiente na extração de cobre e zinco em solos com alto teor de MO, podendo substituir o método atual.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The distribution of delta ferrite fraction was measured with the magnetic method in specimens of different stainless steel compositions cast by the investment casting (lost wax) process. Ferrite fraction measurements published in the literature for stainless steel cast samples were added to the present work data, enabling an extensive analysis about practical methods to calculate delta ferrite fractions in stainless steel castings. Nineteen different versions of practical methods were formed using Schaeffler, DeLong, and Siewert diagrams and the nickel and chromium equivalent indexes suggested by several authors. These methods were evaluated by a detailed statistical analysis, showing that the Siewert diagram, including its equivalent indexes and iso-ferrite lines, gives the lowest relative errors between calculated and measured delta ferrite fractions. Although originally created for stainless steel welds, this diagram gives relative errors lower than those for the current ASTM standard method (800/A 800M-01), developed to predict ferrite fractions in stainless steel castings. Practical methods originated from a combination of different chromium/nickel equivalent indexes and the iso-ferrite lines from Schaeffler diagram give the lowest relative errors when compared with combinations using other iso-ferrite line diagrams. For the samples cast in the present work, an increase in cooling rate from 0.78 to 2.7 K/s caused a decrease in the delta ferrite fraction, but a statistical hypothesis test revealed that this effect is significant in only 50% of the samples that have ferrite in their microstructures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

International Journal of Paediatric Dentistry 2012; 22: 459466 Aim. This in vitro study aimed to test the performance of fluorescence-based methods in detecting occlusal caries lesions in primary molars compared to conventional methods. Design. Two examiners assessed 113 sites on 77 occlusal surfaces of primary molars using three fluorescence devices: DIAGNOdent (LF), DIAGNOdent pen (LFpen), and fluorescence camera (VistaProof-FC). Visual inspection (ICDAS) and radiographic methods were also evaluated. One examiner repeated the evaluations after one month. As reference standard method, the lesion depth was determined after sectioning and evaluation in stereomicroscope. The area under the ROC curve (Az), sensitivity, specificity, and accuracy of the methods were calculated at enamel (D1) and dentine caries (D3) lesions thresholds. The intra and interexaminer reproducibility were calculated using the intraclass correlation coefficient (ICC) and kappa statistics. Results. At D1, visual inspection presented higher sensitivities (0.970.99) but lower specificities (0.180.25). At D3, all the methods demonstrated similar performance (Az values around 0.90). Visual and radiographic methods showed a slightly higher specificity (values higher than 0.96) than the fluorescence based ones (values around 0.88). In general, all methods presented high reproducibility (ICC higher than 0.79). Conclusions. Although fluorescence-based and conventional methods present similar performance in detecting occlusal caries lesions in primary teeth, visual inspection alone seems to be sufficient to be used in clinical practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pulmonary arterial hypertension (PAH) is a disease of the pulmonary vasculature characterized by vasoconstriction and vascular remodeling leading to a progressive increase in pulmonary vascular resistance (PVR). It is becoming increasingly recognized that it is the response of the right ventricle (RV) to the increased afterload resulting from this increase in PVR that is the most important determinant of patient outcome. A range of hemodynamic, structural, and functional measures associated with the RV have been found to have prognostic importance in PAH and, therefore, have potential value as parameters for the evaluation and follow-up of patients. If such measures are to be used clinically, there is a need for simple, reproducible, accurate, easy-to-use, and noninvasive methods to assess them. Cardiac magnetic resonance imaging (CMRI) is regarded as the "gold standard" method for assessment of the RV, the complex structure of which makes accurate assessment by 2-dimensional methods, such as echocardiography, challenging. However, the majority of data concerning the use of CMRI in PAH have come from studies evaluating a variety of different measures and using different techniques and protocols, and there is a clear need for the development of standardized methodology if CMRI is to be established in the routine assessment of patients with PAH. Should such standards be developed, it seems likely that CMRI will become an important method for the noninvasive assessment and monitoring of patients with PAH. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;110[suppl]:25S-31S)