969 resultados para Soft liner material


Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. MATERIAL AND METHODS: For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. RESULTS: All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. CONCLUSIONS: The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Long-term fluoride application on the teeth of patients receiving radiation therapy for head and neck tumors results in excessive staining and roughening of ceramic restorations. PURPOSE: The purpose of this in vitro study was to compare the staining effects of 2 fluoride treatments on ceramic disks by simulating 1 year of clinical exposure at 10 minutes per day. In addition, 2 different surface preparations were tested. MATERIAL AND METHODS: Eighty ceramic disks (IPS Empress), 20 x 2 mm, were fabricated. Half of the disks were glazed, and the remaining disks were polished. All disks were brushed for 3 minutes with a soft-bristle power toothbrush and mild dentifrice (baseline) and were immersed in 1 of the 2 fluoride products (0.4% SnF(2), Gel-Kam Gel, or 1.1% NaF, Prevident 5000) for 10 days (n=20). Means and standard deviations of color change (Delta E), surface roughness (Ra, um), and surface gloss (GU) of the ceramic material were measured with a reflection spectrophotometer, a profilometer, and a gloss meter, respectively, at baseline and after fluoride treatment. Two- and 3-way ANOVA (alpha=.05), with surface preparation (polished vs. glazed) and fluoride treatment (0.4% SnF(2) or 1.1% NaF) as independent variables and condition (baseline vs. after fluoride treatment) as a repeated measure, was used to analyze the data. Fisher's PLSD intervals (alpha=.05) were calculated for comparisons among the means. RESULTS: The polished specimens had significantly higher Delta E values, significantly higher surface gloss values, and significantly lower surface roughness values than the glazed specimens before fluoride treatment (P<.001). After both fluoride treatments, ceramic disks exhibited significantly higher surface roughness values when polished and significantly lower surface gloss values when glazed or polished (P<.001). The glazed specimens presented significantly higher surface roughness (P<.001) and lower surface gloss values (P<.001) when treated with 0.4% SnF(2) as compared to NaF. For the polished specimens, there was no significant difference in surface roughness and surface gloss values between the 2 fluoride treatments. CONCLUSIONS: Use of 0.4% SnF(2) and 1.1% NaF gels, in vitro, caused significant color change in the polished IPS Empress ceramic disks. Polishing of the ceramic surface before immersion in either fluoride agent caused the ceramic tested to be more resistant to etching by the 2 solutions tested. The NaF caused less deterioration of the porcelain surface and was less stain inducing than SnF(2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. MATERIAL AND METHODS This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. RESULTS AND CONCLUSIONS The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To investigate and correct the temperature dependence of postmortem MR quantification used for soft tissue characterization and differentiation in thoraco-abdominal organs. MATERIAL AND METHODS Thirty-five postmortem short axis cardiac 3-T MR examinations were quantified using a quantification sequence. Liver, spleen, left ventricular myocardium, pectoralis muscle and subcutaneous fat were analysed in cardiac short axis images to obtain mean T1, T2 and PD tissue values. The core body temperature was measured using a rectally inserted thermometer. The tissue-specific quantitative values were related to the body core temperature. Equations to correct for temperature differences were generated. RESULTS In a 3D plot comprising the combined data of T1, T2 and PD, different organs/tissues could be well differentiated from each other. The quantitative values were influenced by the temperature. T1 in particular exhibited strong temperature dependence. The correction of quantitative values to a temperature of 37 °C resulted in better tissue discrimination. CONCLUSION Postmortem MR quantification is feasible for soft tissue discrimination and characterization of thoraco-abdominal organs. This provides a base for computer-aided diagnosis and detection of tissue lesions. The temperature dependence of the T1 values challenges postmortem MR quantification. Equations to correct for the temperature dependence are provided. KEY POINTS • Postmortem MR quantification is feasible for soft tissue discrimination and characterization • Temperature dependence of the T1 values challenges the MR quantification approach • The results provide the basis for computer-aided postmortem MRI diagnosis • Diagnostic criteria may also be applied for living patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Material properties of soft tissues are highly conditioned by the hierarchical structure of this kind of composites. These collagen-based tissues present a complex framework of fibres, fibrils, tropocollagen molecules and amino-acids. As the structural mechanisms that control the degradation of soft tissues are related with the behaviour of its fundamental constituents, the relationship between the molecular and intermolecular properties and the tissue behaviour needs to be studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Integrity assurance of configuration data has a significant impact on microcontroller-based systems reliability. This is especially true when running applications driven by events which behavior is tightly coupled to this kind of data. This work proposes a new hybrid technique that combines hardware and software resources for detecting and recovering soft-errors in system configuration data. Our approach is based on the utilization of a common built-in microcontroller resource (timer) that works jointly with a software-based technique, which is responsible to periodically refresh the configuration data. The experiments demonstrate that non-destructive single event effects can be effectively mitigated with reduced overheads. Results show an important increase in fault coverage for SEUs and SETs, about one order of magnitude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine the critical fitting characteristics of modern soft contact lens fits and from this to devise a simplified recording scheme. Methods: Ten subjects (aged 28.1 ± 7.4 years) wore eight different modern soft contact lenses. Video was captured and analysed of blink (central and up-gaze), excursion lag (up, down, right and left gaze) and push-up movement, centration and coverage. Results: Lens centration was on average close to the corneal centre. Movement on blink was significantly smaller in up-gaze than in primary-gaze (p<0.001). Lag was greatest in down-gaze and least in up-gaze (p<0.001). Push-up test recovery speed was 1.32±0.73mm/s. Overall lens movement was determined best by assessing horizontal lag, movement on blink in up-gaze and push-up recovery speed. Steeper lens base-curves did not have a significant effect on lens fit characteristics. Contact lens material did influence lens fit characteristics, particularly silicone-hydrogels which generally had lower centration and a faster push-up speed of recovery than HEMA lenses (p<0.05). Conclusion: Lag on vertical gaze, and movement on blink in primary gaze generally provide little extra information on overall lens movement compared to horizontal lag, movement on blink in up gaze and push-up recovery speed. They can therefore be excluded from a simplified recording scheme. A simplified and comprehensive soft contact lens fit recording system could consist of a cross-hairs indicating the centre of the cornea; a circle to indicate the lens centration; a mark on the relevant position of the circle to indicate any limbal incursion; a grade (‘B’) below for movement with blink in up-gaze, a grade (‘L’) to the side for horizontal lag and a grade above (‘P’) for the assessed push-up recovery speed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Soft contact lens wear has become a common phenomenon in recent times. The contact lens when placed in the eye rapidly undergoes change. A film of biological material builds up on and in the lens matrix. The long term wear characteristics of the lens ultimately depend on this process. With time distinct structures made up of biological material have been found to build up on the lens. A fuller understanding of this process and how it relates to the lens chemistry could lead to contact lenses that are better tolerated by the eye. The tear film is a complex biological fluid, it is this fluid that bathes the lens during wear. It is reasonable to suppose that it is material derived from this source that accumulates on the lens. To understand this phenomenon it was decided to investigate the make up and conformation of the protein species that are found on and in the lens. As inter individual variations in tear fluid composition have been found it is important to be able to study the proteins on a single lens. Many of the analytical techniques used in bio research are not suitable for this study because of the lack of sensitivity. Work with poly acrylamide electrophoresis showed the possibility of analyzing the proteins extracted from a single lens. The development of a biotin avidin electro-blot and an enzyme linked aniibody electro-blot, lead to the high sensitivity detection and identification of the proteins present. The extraction of proteins from a lens is always incomplete. A method that analyses the proteins in situ would be a great advancement. Fourier transform infra red microscopy was developed to a point where a thin section of a contact lens could yield information about the proteins present and their conformation. The three dimensional structure of the gross macroscopic structures termed white spots was investigated using confocal laser microscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To evaluate the influence of soft contact lens midperipheral shape profile and edge design on the apparent epithelial thickness and indentation of the ocular surface with lens movement. Methods. Four soft contact lens designs comprising of two different plano midperipheral shape profiles and two edge designs (chiseled and knife edge) of silicone-hydrogel material were examined in 26 subjects aged 24.7 ± 4.6 years, each worn bilaterally in randomized order. Lens movement was imaged enface on insertion, at 2 and 4 hours with a high-speed, high-resolution camera simultaneous to the cross-section of the edge of the contact lens interaction with the ocular surface captured using optical coherence tomography (OCT) nasally, temporally, and inferiorly. Optical imaging distortions were individually corrected for by imaging the apparent distortion of a glass slide surface by the removed lens. Results. Apparent epithelial thickness varied with edge position (P < 0.001). When distortion was corrected for, epithelial indentation decreased with time after insertion (P = 0.010), changed after a blink (P < 0.001), and varied with position on the lens edge (P < 0.001), with the latter being affected by midperipheral lens shape profile and edge design. Horizontal and vertical lens movement did not change with time postinsertion. Vertical motion was affected by midperipheral lens shape profile (P < 0.001) and edge design (P < 0.001). Lens movement was associated with physiologic epithelium thickness for lens midperipheral shape profile and edge designs. Conclusions. Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the adhesive properties of an in-house amino-propyltrimethoxysilane-methylenebisacrylamide (APTMS-MBA) siloxane system and compare them with a commercially available adhesive, n-butyl cyanoacrylate (nBCA). The ability of the material to perform as a soft tissue adhesive was established by measuring the physical (bond strength, curing time) and biological (cytotoxicity) properties of the adhesives on cartilage. Complementary physical techniques, X-ray photoelectron spectroscopy, Raman and infrared imaging, enabled the mode of action of the adhesive to the cartilage surface to be determined. Adhesion strength to cartilage was measured using a simple butt joint test after storage in phosphate-buffered saline solution at 37°C for periods up to 1 month. The adhesives were also characterised using two in vitro biological techniques. A live/dead stain assay enabled a measure of the viability of chondrocytes attached to the two adhesives to be made. A water-soluble tetrazolium assay was carried out using two different cell types, human dermal fibroblasts and ovine meniscal chondrocytes, in order to measure material cytotoxicity as a function of both supernatant concentration and time. IR imaging of the surface of cartilage treated with APTMS-MBA siloxane adhesive indicated that the adhesive penetrated the tissue surface marginally compared to nBCA which showed a greater depth of penetration. The curing time and adhesion strength values for APTMS-MBA siloxane and nBCA adhesives were measured to be 60 s/0.23 MPa and 38 min/0.62 MPa, respectively. These materials were found to be significantly stronger than either commercially available fibrin (0.02 MPa) or gelatin resorcinol formaldehyde (GRF) adhesives (0.1 MPa) (P <0.01). Cell culture experiments revealed that APTMS-MBA siloxane adhesive induced 2% cell death compared to 95% for the nBCA adhesive, which extended to a depth of approximately 100-150 μm into the cartilage surface. The WST-1 assay demonstrated that APTMS-MBA siloxane was significantly less cytotoxic than nBCA adhesive as an undiluted conditioned supernatant (P <0.001). These results suggest that the APTMS-MBA siloxane may be a useful adhesive for medical applications. © VSP 2005.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The phenomenon of microscopic hot-spots, during the calcination of MCM-41, was investigated by quantifying the magnitude of the temperature increase during the calcination of a soft MCM-41 mesophase using a SAXS comparative study. This was performed by thermally treating a soft material that was detemplated via Fenton chemistry followed by equilibrating and drying in a low-surface-tension solvent (n-butanol or N,N-dimethylformamide); these samples have limited structural shrinkage. The resulting samples were thermally treated at increasing temperatures, and the structural shrinkage was compared with that of the directly calcined material. By comparing the structural shrinkage, it was found that the microscopic temperature increase would fall between 190 and 250 C, as deduced from N,N-dimethyl-formamide and n-butanol. The order of magnitude of the temperature increase appears to be consistent with the well-known glow effect. It is, however, substantially higher than the experimentally determined macroscopic temperature increase. Several aspects are discussed to interpret this difference. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A mild protocol that allows the template removal of soft un-aged silica nanoparticles was investigated. After oxidizing the organic template by Fenton chemistry, a good structural preservation is only achieved when the material is equilibrated and dried in a low-surface tension solvent. This avoids excessive capillary stress induced by the high surface tension of water, a major component in the Fenton reaction medium. The Fenton reaction should be carried out under mild conditions as well; otherwise the sample deteriorates by extensive hydrolysis, and capillary stress, and the structural ordering diminishes severely. We propose employing 10 ppm Fe concentration at 70 °C for 24 h for the cetyltrimethylammonium bromide template. The proposed protocol involves 2 steps resulting in an overall significantly higher pore volume attributed to the wider pores and limited particle agglomeration, while the calcined counterpart evidences aggregation and loss of the hexagonal ordering. n-BuOH exchange is unnecessary when the mesophase is stabilized by ageing, as the structure resists the water capillary stress. © The Royal Society of Chemistry 2013.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study explores how great powers not allied with the United States formulate their grand strategies in a unipolar international system. Specifically, it analyzes the strategies China and Russia have developed to deal with U.S. hegemony by examining how Moscow and Beijing have responded to American intervention in Central Asia. The study argues that China and Russia have adopted a soft balancing strategy of to indirectly balance the United States at the regional level. This strategy uses normative capabilities such as soft power, alternative institutions and regionalization to offset the overwhelming material hardware of the hegemon. The theoretical and methodological approach of this dissertation is neoclassical realism. Chinese and Russian balancing efforts against the United States are based on their domestic dynamics as well as systemic constraints. Neoclassical realism provides a bridge between the internal characteristics of states and the environment which those states are situated. Because China and Russia do not have the hardware (military or economic power) to directly challenge the United States, they must resort to their software (soft power and norms) to indirectly counter American preferences and set the agenda to obtain their own interests. Neoclassical realism maintains that soft power is an extension of hard power and a reflection of the internal makeup of states. The dissertation uses the heuristic case study method to demonstrate the efficacy of soft balancing. Such case studies help to facilitate theory construction and are not necessarily the demonstrable final say on how states behave under given contexts. Nevertheless, it finds that China and Russia have increased their soft power to counterbalance the United States in certain regions of the world, Central Asia in particular. The conclusion explains how soft balancing can be integrated into the overall balance-of-power framework to explain Chinese and Russian responses to U.S. hegemony. It also suggests that an analysis of norms and soft power should be integrated into the study of grand strategy, including both foreign policy and military doctrine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pico de Navas landslide was a large-magnitude rotational movement, affecting 50x106m3 of hard to soft rocks. The objectives of this study were: (1) to characterize the landslide in terms of geology, geomorphological features and geotechnical parameters; and (2) to obtain an adequate geomechanical model to comprehensively explain its rupture, considering topographic, hydro-geological and geomechanical conditions. The rupture surface crossed, from top to bottom: (a) more than 200 m of limestone and clay units of the Upper Cretaceous, affected by faults; and (b) the Albian unit of Utrillas facies composed of silty sand with clay (Kaolinite) of the Lower Cretaceous. This sand played an important role in the basal failure of the slide due to the influence of fine particles (silt and clay), which comprised on average more than 70% of the sand, and the high content presence of kaolinite (>40%) in some beds. Its geotechnical parameters are: unit weight (δ) = 19-23 KN/m3; friction angle (φ) = 13º-38º and cohesion (c) = 10-48 KN/m2. Its microstructure consists of accumulations of kaolinite crystals stuck to terrigenous grains, making clayey peds. We hypothesize that the presence of these aggregates was the internal cause of fluidification of this layer once wet. Besides the faulted structure of the massif, other conditioning factors of the movement were: the large load of the upper limestone layers; high water table levels; high water pore pressure; and the loss of strength due to wet conditions. The 3D simulation of the stability conditions concurs with our hypothesis. The landslide occurred in the Recent or Middle Holocene, certainly before at least 500 BC and possibly during a wet climate period. Today, it appears to be inactive. This study helps to understand the frequent slope instabilities all along the Iberian Range when facies Utrillas is present.