846 resultados para Screen-printed electrode


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the sensitivity of information processing, recall and orientation tasks to the presence of mild Traumatic Brain Injury (mTBI). Fifty-six (40 male, 16 female) mTBI patients and 85 (57 male and 28 female) controls with orthopaedic injuries were tested within 24 hr of injury in the Department of Emergency Medicine. mTBI patients answered fewer orientation questions and recalled fewer words in delayed recall than orthopaedic patients. mTBI patients judged fewer sentences in 2 min than orthopaedic controls, and female mTBI patients judged fewer sentences than male mTBI patients. Male mTBI patients correctly recalled fewer words during immediate memory and learning than female mTBI patients and orthopaedic controls. Those mTBI patients with a history of previous head injuries did not perform more poorly than those mTBI patients without previous head injuries. These results indicate that tests of speed of information processing, word learning and orientation questions are sensitive to the acute effects of mTBI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. Aim: To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Methods: Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects, Results: The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. Conclusion: These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. (C) 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article, which is part of a larger historical study of infant-feeding advice received by mothers in Queensland, Australia, identifies and examines print materials that were used by mothers, or that influenced other texts, during the postwar period from 1945 to 1965. The texts are described within the context of their environmental influences and the medical knowledge and research of the time to assess what effect, if any, these latter materials had on the established system of infant-feeding advice. Two innovations that were employed are the use of interviews to identify the most-used texts and the comparison of popular advice books with medical journal material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a subtractive hybridisation approach, we enriched for genes likely to play a role in embryonic development of the mammalian face and other structures. This was achieved by subtracting cDNA derived from adult mouse liver from that derived from 10.5 dpc mouse embryonic branchial arches 1 and 2. Random sequencing of clones from the resultant library revealed that a high percentage correspond to genes with a previously established role in embryonic development and disease, while 15% represent novel or uncharacterised genes. Whole mount in situ hybridisation analysis of novel genes revealed that approximately 50% have restricted expression during embryonic development. In addition to expression in branchial arches, these genes showed a range of expression domains commonly including neural tube and somites. Notably, all genes analysed were found to be expressed not only in the branchial arches but also in the developing limb buds, providing support for the hypothesis that development of the limbs and face is likely to involve analogous molecular processes. (C) 2003 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Provision of health information to people with aphasia is inadequate. Current practice in providing printed health education materials to people with aphasia does not routinely take into consideration their language and associated reading difficulties. Aims: This study aimed to investigate if people with aphasia can comprehend health information contained in printed health education materials and if the application of aphasia-friendly principles is effective in assisting them to comprehend health information. It was hypothesised that participants with aphasia would comprehend significantly more information from aphasia-friendly materials than from existing materials. Other aims included investigating if the effectiveness of the aphasia-friendly principles is related to aphasia severity, if people with aphasia are more confident in responding to health information questions after they have read the aphasia-friendly material, if they prefer to read the aphasia-friendly brochures, and if they prefer to read the brochure type that resulted in the greatest increase in their knowledge. Methods & Procedures: Twelve participants with mild to moderately severe aphasia were matched according to their reading abilities. A pre and post experimental design was employed with repeated measures ANOVA (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the 12-lead electrocardiogram has become an essential medical and research tool, many current and envisaged applications would benefit from simpler devices, using 3-lead ECG configuration. This is particularly true for Ambient Assisted Living (in a broad perspective). However, the chest anatomy of female patients, namely during pregnancy, can hamper the adequate placement of a 3-lead ECG device and, very often, electrodes are placed below the chest rather than at the precise thoracic landmarks. Thus, the aim of this study was to compare the effect of electrode positioning on the ECG signal of pregnant women and provide guidelines for device development. The effect of breast tissue on the ECG signal was investigated by relating breast size with the signal-to-noise ratio, root mean square and R-wave amplitude. Results show that the 3-lead ECG should be placed on the breast rather than under the breast and indicate positive correlation between breast size and signal-to-noise ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A unique neural electrode design is proposed with 3 mm long shafts made from an aluminum-based substrate. The electrode is composed by 100 individualized shafts in a 10 × 10 matrix, in which each aluminum shafts are precisely machined via dicing-saw cutting programs. The result is a bulk structure of aluminum with 65 ° angle sharp tips. Each electrode tip is covered by an iridium oxide thin film layer (ionic transducer) via pulsed sputtering, that provides a stable and a reversible behavior for recording/stimulation purposes, a 40 mC/cm2 charge capacity and a 145 Ω impedance in a wide frequency range of interest (10 Hz-100 kHz). Because of the non-biocompatibility issue that characterizes aluminum, an anodization process is performed that forms an aluminum oxide layer around the aluminum substrate. The result is a passivation layer fully biocompatible that furthermore, enhances the mechanical properties by increasing the robustness of the electrode. For a successful electrode insertion, a 1.1 N load is required. The resultant electrode is a feasible alternative to silicon-based electrode solutions, avoiding the complexity of its fabrication methods and limitations, and increasing the electrode performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports on a-Si:H-based low-leakage blue-enhanced photodiodes for dual-screen x-ray imaging detectors. Doped nanocrystalline silicon was incorporated in both the n- and p-type regions to reduce absorption losses for light incoming from the top and bottom screens. The photodiode exhibits a dark current density of 900 pA/cm(2) and an external quantum efficiency up to 90% at a reverse bias of 5 V. In the case of illumination through the tailored p-layer, the quantum efficiency of 60% at a 400 nm wavelength is almost double that for the conventional a-Si:H n-i-p photodiode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Programas de investigação epidemiológica e de ação no âmbito da violência familiar estão em franca ascensão, requerendo instrumentos de aferição adaptados e vertidos para o português. O objetivo do estudo é avaliar a equivalência semântica entre o original em inglês e duas versões para o português do instrumento Abuse Assessment Screen (AAS) usado no rastreamento de casos de violência contra a mulher grávida e recomendar uma versão-síntese para uso corrente. MÉTODOS: O processo de avaliação de equivalência semântica envolveu quatro etapas: tradução, retradução, apreciação formal de equivalência e crítica final através de consultas com especialista na área temática. RESULTADOS: Para cada item do instrumento apresentam-se os resultados relativos às quatro etapas. O texto cobre cada passo do processo que levou à versão final. As duas versões mostraram-se bastante semelhantes, com 14 das 15 assertivas similares, embora a segunda versão tenha se mostrado mais adequada, ainda que para alguns itens tenha sido decidido juntar as duas versões ou mesmo utilizar um item oriundo da versão um. CONCLUSÃO: É importante usar mais de uma versão no processo, em várias etapas de avaliação e de crítica, e discutir a pertinência de se acrescentar uma etapa adicional de interlocução do instrumento com membros da população-alvo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biosensor for urea has been developed based on the observation that urea is a powerful active-site inhibitor of amidase, which catalyzes the hydrolysis of amides such as acetamide to produce ammonia and the corresponding organic acid. Cell-free extract from Pseudomonas aeruginosa was the source of amidase (acylamide hydrolase, EC 3.5.1.4) which was immobilized on a polyethersulfone membrane in the presence of glutaraldehyde; anion-selective electrode for ammonium ions was used for biosensor development. Analysis of variance was used for optimization of the biosensorresponse and showed that 30 mu L of cell-free extract containing 7.47 mg protein mL(-1), 2 mu L of glutaraldehyde (5%, v/v) and 10 mu L of gelatin (15%, w/v) exhibited the highest response. Optimization of other parameters showed that pH 7.2 and 30 min incubation time were optimum for incubation ofmembranes in urea. The biosensor exhibited a linear response in the range of 4.0-10.0 mu M urea, a detection limit of 2.0 mu M for urea, a response timeof 20 s, a sensitivity of 58.245 % per mu M urea and a storage stability of over 4 months. It was successfully used for quantification of urea in samples such as wine and milk; recovery experiments were carried out which revealed an average substrate recovery of 94.9%. The urea analogs hydroxyurea, methylurea and thiourea inhibited amidase activity by about 90%, 10% and 0%, respectively, compared with urea inhibition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para dar resposta aos grandes avanços tecnológicos e, consequentemente, à postura mais exigente dos clientes, a empresa Francisco Parracho – Electrónica Industrial, Lda., que tem actividade no ramo dos elevadores, decidiu introduzir no mercado um controlador dedicado de ecrãs Liquid Crystal Display / Thin Film Transistor (LCD / TFT). O objectivo é substituir um sistema suportado por um computador, caracterizado pelas suas elevadas dimensões e custos, mas incontornável até à data, nomeadamente para resoluções de ecrã elevadas. E assim nasceu este trabalho. Com uma selecção criteriosa de todos os componentes e, principalmente, sem funcionalidades inúteis, obteve-se um sistema embebido com dimensões e custos bem mais reduzidos face ao seu opositor. O ecrã apontado para este projecto é um Thin Film Transistor – Liquid Crystal Display (TFT-LCD) da Sharp de 10.4” de qualidade industrial, com uma resolução de 800 x 600 píxeis a 18 bits por píxel. Para tal, foi escolhido um micro-controlador da ATMEL, um AVR de 32 bits que, entre outras características, possui um controlador LCD que suporta resoluções até 2048 x 2048 píxeis, de 1 a 24 bits por píxel. Atendendo ao facto deste produto ser inserido na área dos elevadores, as funcionalidades, quer a nível do hardware quer a nível do software, foram projectadas para este âmbito. Contudo, o conceito aqui exposto é adjacente a quaisquer outras áreas onde este produto se possa aplicar, até porque o software está feito para se tornar bem flexível. Com a ajuda de um kit de desenvolvimento, foram validados os drivers dos controladores e periféricos base deste projecto. De seguida, aplicou-se esse software numa placa de circuito impresso, elaborada no âmbito deste trabalho, para que fossem cumpridos todos os requisitos requeridos pela empresa patrocinadora: - Apresentação de imagens no ecrã consoante o piso; - Possibilidade de ter um texto horizontalmente deslizante;Indicação animada do sentido do elevador; - Representação do piso com deslizamento vertical; - Descrição sumária do directório de pisos também com deslizamento vertical; - Relógio digital; - Leitura dos conteúdos pretendidos através de um cartão SD/MMC; - Possibilidade de actualização dos conteúdos via USB flash drive.