959 resultados para Readability Formulas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study noisy computation in randomly generated k-ary Boolean formulas. We establish bounds on the noise level above which the results of computation by random formulas are not reliable. This bound is saturated by formulas constructed from a single majority-like gate. We show that these gates can be used to compute any Boolean function reliably below the noise bound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

* This work was financially supported by the Russian Foundation for Basic Research, project no. 04-01-00858a.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mathematics Subject Classification: 42A38, 42C40, 33D15, 33D60

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantitative analysis of receptor-mediated effect is based on experimental concentration-response data in which the independent variable, the concentration of a receptor ligand, is linked with a dependent variable, the biological response. The steps between the drug–receptor interaction and the subsequent biological effect are to some extent unknown. The shape of the fitting curve of the experimental data may give some in-sights into the nature of the concentration–receptor–response (C-R-R) mechanism. It can be evaluated by non-linear regression analysis of the experimental data points of the independent and dependent variables, which could be considered as a history of the interaction between the drug and receptors. However, this information is not enough to evaluate such important parameters of the mechanism as the dissociation constant (affinity) and efficacy. There are two ways to provide more detailed information about the C-R-R mechanism: (i) an experimental way for obtaining data with new or

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2010 Mathematics Subject Classification: Primary 65D30, 32A35, Secondary 41A55.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the Parr-Hubbard and Knudtson formulas to calculate retinal vessel calibers and to examine the effect of omitting vessels on the overall result. METHODS: We calculated the central retinal arterial equivalent (CRAE) and central retinal venular equivalent (CRVE) according to the formulas described by Parr-Hubbard and Knudtson including the six largest retinal arterioles and venules crossing through a concentric ring segment (measurement zone) around the optic nerve head. Once calculated, we removed one arbitrarily selected artery and one arbitrarily selected vein and recalculated all outcome parameters again for (1) omitting one artery only, (2) omitting one vein only, and (3) omitting one artery and one vein. All parameters were compared against each other. RESULTS: Both methods showed good correlation (r for CRAE = 0.58; r for CRVE = 0.84), but absolute values for CRAE and CRVE were significantly different from each other when comparing both methods (p < 0.000001): CRAE had higher values for the Parr-Hubbard (165 [±16] μm) method compared with the Knudtson method (148 [±15] μm). In addition, CRAE and CRVE values dropped for both methods when omitting one arbitrarily selected vessel each (all p < 0.000001). Arteriovenous ratio (AVR) calculations showed a similar change for both methods when omitting one vessel each: AVR decreased when omitting one arteriole whereas it increased when omitting one venule. No change, however, was observed for AVR calculated with six or five vessel pairs each. CONCLUSIONS: Although the absolute value for CRAE and CRVE is changing significantly depending on the number of vessels included, AVR appears to be comparable as long as the same number of arterioles and venules is included.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MSC 2010: 33C15, 33C05, 33C45, 65R10, 20C40

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to identify problems when translating standard formulas of expression in English to Spanish legal translation. To achieve the goal, a total of 250 Spanish translations were analyzed of 10 sentences from legal texts in English. The degree of difficulty posed by the translation of these formulas is confirmed by the results obtained, which is related not so much to the intrinsic meaning of the words that compose them, but to their contextual meaning. An eclectic approach that combines discourse analysis with contrastive linguistics is proposed, and some specific didactic guidelines are indicated to facilitate the translation teaching of these standard formulas of expression. Lexical interpretation and contextual recreation allow the apprentice translator to make progress with the translation of these phrases and to improve his/her attitude when facing them to achieve a successful semantic and contextual interpretation, that is to say, getting the closest natural equivalent while respecting the genius of the language.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes part of an ongoing effort to improve the readability of Swedish electronic health records (EHRs). An EHR contains systematic documentation of a single patient’s medical history across time, entered by healthcare professionals with the purpose of enabling safe and informed care. Linguistically, medical records exemplify a highly specialised domain, which can be superficially characterised as having telegraphic sentences involving displaced or missing words, abundant abbreviations, spelling variations including misspellings, and terminology. We report results on lexical simplification of Swedish EHRs, by which we mean detecting the unknown, out-ofdictionary words and trying to resolve them either as compounded known words, abbreviations or misspellings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In acquired immunodeficiency syndrome (AIDS) studies it is quite common to observe viral load measurements collected irregularly over time. Moreover, these measurements can be subjected to some upper and/or lower detection limits depending on the quantification assays. A complication arises when these continuous repeated measures have a heavy-tailed behavior. For such data structures, we propose a robust structure for a censored linear model based on the multivariate Student's t-distribution. To compensate for the autocorrelation existing among irregularly observed measures, a damped exponential correlation structure is employed. An efficient expectation maximization type algorithm is developed for computing the maximum likelihood estimates, obtaining as a by-product the standard errors of the fixed effects and the log-likelihood function. The proposed algorithm uses closed-form expressions at the E-step that rely on formulas for the mean and variance of a truncated multivariate Student's t-distribution. The methodology is illustrated through an application to an Human Immunodeficiency Virus-AIDS (HIV-AIDS) study and several simulation studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física