969 resultados para Radiation dose reduction
Resumo:
The aim of the present study was to establish the extent of in vitro radioresponse of lymphocytes among 62 healthy adults of both genders and to estimate the distribution of baseline micronuclei and radiosensitivity among individuals of the study population using the cytochalasin block micronucleus test. A younger study group consisted of 10 males (mean age, 22.4 years; range, 21-27) and 12 females (mean age, 24.8 years; range, 20-29), whereas an older study group consisted of 18 males (mean age, 35.1 years; range, 30-44) and 22 females (mean age, 38.5 years; range, 30-48). For evaluation of radiosensitivity blood samples were irradiated in vitro using 60Co g-ray source. The radiation dose employed was 2 Gy, the dose rate 0.45 Gy/min. The study revealed a significant gender effect on baseline micronuclei favoring females (Z = 3.25, P < 0.001), while yields of radiation-induced micronuclei did not differ significantly (Z = 0.56, P < 0.56) between genders. The distribution of baseline micronuclei among the individuals tested followed Poisson distribution in both study groups and in both genders, whereas the distribution of radiosensitivity among individuals of the older study group did not fulfill Poisson expectations (Kolmogorov-Smirnof test, P < 0.01). In contrast to a nonsignificant difference in radiosensitivity between males and females of the same age group (Z = 1.97, P < 0.56), a statistically significant difference in radiosensitivity between younger and older group for both genders was found (Z = 3.03, P < 0.03). Since the individuals tested were healthy, the observed variability in radiation response is considered to be an early effect of ageing.
Resumo:
According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry.
Resumo:
Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates.
Resumo:
Since previous investigations have shown that low levels of ionizing radiation can induce a reduction in the rates of apparent photosynthesis and in the magnitude of photoassimilated l4C exported out of a leaf, the present studies were designed and conducted to determine the relationship, if any, between the radiation effects on these two physiological processes. The experiments were particularly designed to determine if the radiation-induced reduction in export is the result of the reduction in photosynthesis and hence availability of materials for translocation or the result of a reduction in the amount of energy available for the vein loading process. This study has shown that the radiation-induced reduction in l4C export out of a leaf is likely related to a loss of energy available for the vein loading process rather than a reduction in the supply of materials available for export due to reduced C02 uptake. The process of photophosphorylation was shown to be reduced by exposure to radiation to an extent similar to the reduction in the export of l4C which was also observed. Both of these processes returned to their pre-irradiation rates 120 minutes following radiatruon exposure. The rate of photosynthetic C02 uptake was also reduced by radiation exposur~ howeve~ this process did not return to the control level nor was the extent of reduction as large as observed for photophosphorylation and photoassimilate export. The observed relationship between the reductions of export and photoph~sphorylation pointed to the utilization of photosynthetically produced ATP in the vein loading process. The radiation-induced reduction in the export of l4C was observed at the highest light intensity used in this study which would also imply the involvement of the photophosphorylation process as an energy seurce for vein loading. The lack of radiation-induced reduction in export at low light intensities was interpreted as being due to the utilization of respiratory derived ATP, a process known to be insensitive to radiation at the levels used in this study, as the energy source for the vein loading process. Studies using plants not stressed by radiation showed that there was an increase in export of 14C with higher light intensities. In summary, the data has been interpreted as showing that at high light intensities the ATP, produced by photophosphorylation, is available for use in the vein loading process. The site of ATP utilization could not be determined from the data obtained in this study but possible sites have been indicated from the work done by other physiologists and are discussed in the thesis.
Resumo:
The effect of pH on the complexation of poly(acrylic acid) with poly(vinyl alcohol) in aqueous solution, the miscibility of these polymers in the solid state and the possibility for crosslinking the blends using gamma radiation has been studied. It is demonstrated that the complexation ability of poly(vinyl alcohol) with respect to poly(acrylic acid) is relatively low in comparison with some other synthetic non-ionic polymers. The precipitation of interpolymer complexes was observed below the critical pH of complexation (pH(crit1)), which characterizes the transition between a compact hydrophobic polycomplex and an extended hydrophilic interpolymer associate. Films prepared by casting from aqueous solutions at different pH values exhibited a transition from miscibility to immiscibility at a certain critical pH, pH(crit2), above which hydrogen bonding is prevented. It is shown here that gamma radiation crosslinking of solid blends is efficient and only results in the formation of hydrogel films for blends prepared between pH(crit1), and pH(crit2). The yield of the gel fraction and the swelling properties of the films depended on the absorbed radiation dose and the polymer ratio.
Resumo:
In medical processes where ionizing radiation is used, dose planning and dose delivery are the key elements to patient safety and treatment success, particularly, when the delivered dose in a single session of treatment can be an order of magnitude higher than the regular doses of radiotherapy. Therefore, the radiation dose should be well defined and precisely delivered to the target while minimizing radiation exposure to surrounding normal tissues [1]. Several methods have been proposed to obtain three-dimensional (3-D) dose distribution [2, 3]. In this paper, we propose an alternative method, which can be easily implemented in any stereotactic radiosurgery center with a magnetic resonance imaging (MRI) facility. A phantom with or without scattering centers filled with Fricke gel solution is irradiated with Gamma Knife(A (R)) system at a chosen spot. The phantom can be a replica of a human organ such as head, breast or any other organ. It can even be constructed from a real 3-D MR image of an organ of a patient using a computer-aided construction and irradiated at a specific region corresponding to the tumor position determined by MRI. The spin-lattice relaxation time T (1) of different parts of the irradiated phantom is determined by localized spectroscopy. The T (1)-weighted phantom images are used to correlate the image pixels intensity to the absorbed dose and consequently a 3-D dose distribution with a high resolution is obtained.
Resumo:
Some dosimetric properties of watch glasses were studied applying the thermoluminescence technique. The watch glass samples were powdered, and the selected grains were mixed with Teflon (TM). The mixture was pressed and sintered to produce pellets of watch glass-Teflon (TM) composites. The glow curves of the pellets show two peaks at 130 and 195 degrees C. Reproducibility of TL response was estimated to have a maximum coefficient of variation of 4.0%. The dose-response curve is sublinear between 0.5 and 20.0kGy. The calibration curve is linear between 1.0Gy and 1.0kGy. The minimum detection limits were also determined. The gamma radiation dose response and the thermal stability of the materials were studied with the purpose to establish the best conditions of watch glasses for use in gamma radiation dosimetry. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
O trabalho foi desenvolvido no município de Jaboticabal, SP, no ano agrícola de 1990/91, onde testou-se a integração de práticas culturais e menor dosagem de herbicida aplicado em pós-emergência na cultura da soja, cultivar Paraná. O delineamento experimental utilizado foi o de blocos ao acaso, com dezesseis tratamentos e quatro repetições, sendo quatro tipos de manejos de plantas daninhas: testemunha infestada, 50% da dose recomendada (360 g/ha do herbicida bentazon, dose recomendada do herbicida bentazon (720 g/ha) e testemunha capinada; dois espaçamentos entre-linhas: 30 cm e 60 cm; e duas densidades: normal e reduzida (em torno de 20 e 10 plantas por metro linear, respectivamente). Observou-se que a quantidade de matéria seca das plantas daninhas por época da colheita da soja, foi ligeiramente maior no tratamento com 50% do que no tratamento com 100% da dose do herbicida, porém a diferença não foi significativa. A produtividade no tratamento com 50% de redução na dose do herbicida foi 8,7% menor do que no tratamento com 100%. A redução de 50% na dose do herbicida testado, quando se interagiu com espaçamento e densidades adequadas (30 cm entre-linhas e densidade normal), é possível, considerando-se aceitável as perdas menores que 10% de grãos de soja em relação ao tratamento com dose normal e levando-se em conta os benefícios de tal redução da dose do herbicida.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The aim of this study is to analyze the effects of copper vapor laser radiation on the radicular wall of human teeth. Materials and Methods: Immediately after the crowns of 10 human uniradicular teeth were cut along the cement-enamel junction, a chemical-surgical preparation of the radicular canals was completed. Then the roots were longitudinally sectioned to allow for irradiation of the surfaces of the dentin walls of the root canals. The hemi-roots were separated into two groups: one (control) with five hemi-roots that were not irradiated, and another (experimental) with 15 hemi-roots divided into three subgroups that were submitted to the following exposure times: 0.02,0.05, and 0.1 s. A copper vapor laser (510.6 nm) with a total average power of 6.5 W in green emission, frequency of 16.000 Hz, and pulse duration of 30 ns was used. Results: The results obtained by scanning electron microscope analysis showed the appearance of a cavity in the region of laser beam impact, with melting, recrystallization, and cracking on the edges of the dentin of the cavity due to heat diffusion. Conclusions: We determined that the copper vapor laser produces significant morphologic changes in the radicular wall of human teeth when using the parameters in this study. However, further research should be done to establish parameters that are compatible with dental structure in order to eliminate thermal damages. © Mary Ann Liebert, Inc.
Resumo:
This study aims the evaluation of the radiation dose levels involved in veterinary radiology and to contribute to review the procedures for performing radiographic exams in animals in the Department of Veterinary Radiology of Faculdade de Medicina Veterinária e Zootecnia of Universidade Estadual Paulista (FMVZ-UNESP/Brazil). The obtained results has shown to be extremely important the assessment of doses involved in veterinary diagnostic radiology procedures both to protect the occupationally exposed workers and to optimize the delivered doses to the animals. © 2009 Springer-Verlag.
Resumo:
This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm X 5 mm) and covered with a Mylar strip. The tip of the lightcuring unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37°C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (α=0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the lightcuring unit and by its light energy density. © Operative Dentistry.
Resumo:
Background & Aims Patients infected with hepatitis C virus (HCV) genotype 1, body weight <85 kg, and high baseline viral load respond poorly to standard doses of pegylated interferon (peginterferon) and ribavirin. We evaluated intensified therapy with peginterferon alfa-2a plus ribavirin. Methods This double-blind randomized trial included HCV genotype 1-infected outpatients from hepatology clinics with body weight <85 kg and HCV RNA titer <400,000 IU/mL. Patients were randomized to 180 μg/wk peginterferon alfa-2a for 48 weeks plus 1200 mg/day ribavirin (standard of care) (group A, n = 191) or 1400/1600 mg/day ribavirin (group B, n = 189). Additional groups included 360 μg/wk peginterferon alfa-2a for 12 weeks then 180 μg/wk peginterferon alfa-2a for 36 weeks plus 1200 mg/day ribavirin (group C, n = 382) or 1400/1600 mg/day ribavirin (group D, n = 383). Follow-up lasted 24 weeks after treatment. Results Sustained virologic response rates (HCV RNA level <15 IU/mL at end of follow-up) in groups A, B, C, and D were 38%, 43%, 44%, and 41%, respectively. There were no significant differences among the 4 groups or between pooled peginterferon alfa-2a regimens (A + B vs C + D: odds ratio [OR], 1.08; 95% confidence interval [CI], 0.831.39; P = .584) or pooled ribavirin regimens (A + C vs B + D: OR, 1.00; 95% CI, 0.791.28; P = .974). Conclusions In patients infected with HCV genotype 1 who are difficult to treat (high viral load, body weight <85 kg), a 12-week induction regimen of peginterferon alfa-2a and/or higher-dose ribavirin is not more effective than the standard regimen. © 2010 AGA Institute.
Resumo:
The aim of this study was to evaluate the effect of specific parameters of low-level laser therapy (LLLT) on biofilms formed by Streptococcus mutans, Candida albicans or an association of both species. Single and dual-species biofilms - SSB and DSB - were exposed to laser doses of 5, 10 or 20 J/cm 2 from a near infrared InGaAsP diode laser prototype (LASERTable; 780 ± 3 nm, 0.04 W). After irradiation, the analysis of biobilm viability (MTT assay), biofilm growth (cfu/mL) and cell morphology (SEM) showed that LLLT reduced cell viability as well as the growth of biofilms. The response of S. mutans (SSB) to irradiation was similar for all laser doses and the biofilm growth was dose dependent. However, when associated with C. albicans (DSB), S. mutans was resistant to LLLT. For C. albicans, the association with S. mutans (DSB) caused a significant decrease in biofilm growth in a dose-dependent fashion. The morphology of the microorganisms in the SSB was not altered by LLLT, while the association of microbial species (DSB) promoted a reduction in the formation of C. albicans hyphae. LLLT had an inhibitory effect on the microorganisms, and this capacity can be altered according to the interactions between different microbial species.
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB