917 resultados para RESONANCE FREQUENCY ANALYSIS
Resumo:
The pirarucu (giant red fish), Arapaima gigas (Cuvier), (Arapaimidae) is among the diverse fish resources of Amazonia which are threatened by over-exploitation. Little is known about the biology of this species despite its commercial importance. The present paper provides indirect information about the length-frequency structure of the stock which was estimated by sampling its tongue bone in craft shops and weighing fresh manias (processed fish product) in fish markets since these were the only remaining recognizable features of the fish. The length-frequency reconstruction was carried out using a regression analysis calculated by utilizing individuals caught in experimental fishing.
Resumo:
Purpose - The purpose of this paper is to present a method to analyze the noise in aircraft cabins through the VHF Aeronautical Communication Channel, aimed at examining an environment that has the possibility of communication problems between the aircraft crew and the professionals responsible for the controls on land. Design/methodology/approach - This analysis includes equipment normally used for identification and comparison of electromagnetic noise, the cabin and the environment that are present in an airport, as well as equipment for frequency analysis and intensity of those signals. The analysis is done in a reverse way, eliminating situations that are not common in the examined environment, until the identification of the situation with the irregularity. Findings - According to the results, the implementation of the Fourier transform for noise analysis in the cabin was efficient. These results demonstrate that through this transformation, the noise sources can be identified in the environments in cases where there is much spectrum pollution. Research limitations/implications - This kind of noise analysis is important, considering the importance of having good accuracy in airport environment analysis. Originality/value - The paper presents the main trends in the future of aviation communications, and describes the new applications that aim to minimize problems with the current VHF channel.
Resumo:
Human T-lymphotropic virus type 1 (HTLV-1) is associated with adult T-cell leukemia (ATL) and HTLV-1 associated myelopathy/tropical spastic paraparesis (HAM/TSP) and has also been implicated in several disorders, including periodontal disease. The proviral load is an important biological marker for understanding HTLV-1 pathogenesis and elucidating whether or not the virus is related to the clinical manifestation of the disease. This study describes the oral health profile of HTLV-1 carriers and HAM/TSP patients in order to investigate the association between the proviral load in saliva and the severity of the periodontal disease and to examine virus intra-host variations from peripheral blood mononuclear cells and saliva cells. It is a cross-sectional analytical study of 90 individuals carried out from November 2006 to May 2008. Of the patients, 60 were HTLV-1 positive and 30 were negative. Individuals from the HTLV-1 positive and negative groups had similar mean age and social-economic status. Data were analyzed using two available statistical software packages, STATA 8.0 and SPSS 11.0 to conduct frequency analysis. Differences of P?<?0.05 were considered statistically significant. HTLV-1 patients had poorer oral health status when compared to seronegative individuals. A weak positive correlation between blood and saliva proviral loads was observed. The mean values of proviral load in blood and saliva in patients with HAM/TSP was greater than those in HTLV-1 carriers. The HTLV-1 molecular analysis from PBMC and saliva specimens suggests that HTLV-1 in saliva is due to lymphocyte infiltration from peripheral blood. A direct relationship between the proviral load in saliva and oral manifestations was observed. J. Med. Virol. 84:1428-1436, 2012. (c) 2012 Wiley Periodicals, Inc.
Resumo:
Ferro- or piezoelectrets are dielectric materials with two elastically very different macroscopic phases and electrically charged interfaces between them. One of the newer piezoelectret variants is a system of two fluoroethylenepropylene (FEP) films that are first laminated around a polytetrafluoroethylene (PTFE) template. Then, by removing the PTFE template, a two-layer FEP structure with open tubular channels is obtained. After electrical charging, the channels form easily deformable macroscopic electric dipoles whose changes under mechanical or electrical stress lead to significant direct or inverse piezoelectricity, respectively. Here, different PTFE templates are employed to generate channel geometries that vary in height or width. It is shown that the control of the channel geometry allows a direct adjustment of the resonance frequencies in the tubular-channel piezoelectrets. By combining several different channel widths in a single ferroelectret, it is possible to obtain multiple resonance peaks that may lead to a rather flat frequency-response region of the transducer material. A phenomenological relation between the resonance frequency and the geometrical parameters of a tubular channel is also presented. This relation may help to design piezoelectrets with a specific frequency response.
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.
Resumo:
Human reactions to vibration have been extensively investigated in the past. Vibration, as well as whole-body vibration (WBV), has been commonly considered as an occupational hazard for its detrimental effects on human condition and comfort. Although long term exposure to vibrations may produce undesirable side-effects, a great part of the literature is dedicated to the positive effects of WBV when used as method for muscular stimulation and as an exercise intervention. Whole body vibration training (WBVT) aims to mechanically activate muscles by eliciting neuromuscular activity (muscle reflexes) via the use of vibrations delivered to the whole body. The most mentioned mechanism to explain the neuromuscular outcomes of vibration is the elicited neuromuscular activation. Local tendon vibrations induce activity of the muscle spindle Ia fibers, mediated by monosynaptic and polysynaptic pathways: a reflex muscle contraction known as the Tonic Vibration Reflex (TVR) arises in response to such vibratory stimulus. In WBVT mechanical vibrations, in a range from 10 to 80 Hz and peak to peak displacements from 1 to 10 mm, are usually transmitted to the patient body by the use of oscillating platforms. Vibrations are then transferred from the platform to a specific muscle group through the subject body. To customize WBV treatments, surface electromyography (SEMG) signals are often used to reveal the best stimulation frequency for each subject. Use of SEMG concise parameters, such as root mean square values of the recordings, is also a common practice; frequently a preliminary session can take place in order to discover the more appropriate stimulation frequency. Soft tissues act as wobbling masses vibrating in a damped manner in response to mechanical excitation; Muscle Tuning hypothesis suggest that neuromuscular system works to damp the soft tissue oscillation that occurs in response to vibrations; muscles alters their activity to dampen the vibrations, preventing any resonance phenomenon. Muscle response to vibration is however a complex phenomenon as it depends on different parameters, like muscle-tension, muscle or segment-stiffness, amplitude and frequency of the mechanical vibration. Additionally, while in the TVR study the applied vibratory stimulus and the muscle conditions are completely characterised (a known vibration source is applied directly to a stretched/shortened muscle or tendon), in WBV study only the stimulus applied to a distal part of the body is known. Moreover, mechanical response changes in relation to the posture. The transmissibility of vibratory stimulus along the body segment strongly depends on the position held by the subject. The aim of this work was the investigation on the effects that the use of vibrations, in particular the effects of whole body vibrations, may have on muscular activity. A new approach to discover the more appropriate stimulus frequency, by the use of accelerometers, was also explored. Different subjects, not affected by any known neurological or musculoskeletal disorders, were voluntarily involved in the study and gave their informed, written consent to participate. The device used to deliver vibration to the subjects was a vibrating platform. Vibrations impressed by the platform were exclusively vertical; platform displacement was sinusoidal with an intensity (peak-to-peak displacement) set to 1.2 mm and with a frequency ranging from 10 to 80 Hz. All the subjects familiarized with the device and the proper positioning. Two different posture were explored in this study: position 1 - hack squat; position 2 - subject standing on toes with heels raised. SEMG signals from the Rectus Femoris (RF), Vastus Lateralis (VL) and Vastus medialis (VM) were recorded. SEMG signals were amplified using a multi-channel, isolated biomedical signal amplifier The gain was set to 1000 V/V and a band pass filter (-3dB frequency 10 - 500 Hz) was applied; no notch filters were used to suppress line interference. Tiny and lightweight (less than 10 g) three-axial MEMS accelerometers (Freescale semiconductors) were used to measure accelerations of onto patient’s skin, at EMG electrodes level. Accelerations signals provided information related to individuals’ RF, Biceps Femoris (BF) and Gastrocnemius Lateralis (GL) muscle belly oscillation; they were pre-processed in order to exclude influence of gravity. As demonstrated by our results, vibrations generate peculiar, not negligible motion artifact on skin electrodes. Artifact amplitude is generally unpredictable; it appeared in all the quadriceps muscles analysed, but in different amounts. Artifact harmonics extend throughout the EMG spectrum, making classic high-pass filters ineffective; however, their contribution was easy to filter out from the raw EMG signal with a series of sharp notch filters centred at the vibration frequency and its superior harmonics (1.5 Hz wide). However, use of these simple filters prevents the revelation of EMG power potential variation in the mentioned filtered bands. Moreover our experience suggests that the possibility of reducing motion artefact, by using particular electrodes and by accurately preparing the subject’s skin, is not easily viable; even though some small improvements were obtained, it was not possible to substantially decrease the artifact. Anyway, getting rid of those artifacts lead to some true EMG signal loss. Nevertheless, our preliminary results suggest that the use of notch filters at vibration frequency and its harmonics is suitable for motion artifacts filtering. In RF SEMG recordings during vibratory stimulation only a little EMG power increment should be contained in the mentioned filtered bands due to synchronous electromyographic activity of the muscle. Moreover, it is better to remove the artifact that, in our experience, was found to be more than 40% of the total signal power. In summary, many variables have to be taken into account: in addition to amplitude, frequency and duration of vibration treatment, other fundamental variables were found to be subject anatomy, individual physiological condition and subject’s positioning on the platform. Studies on WBV treatments that include surface EMG analysis to asses muscular activity during vibratory stimulation should take into account the presence of motion artifacts. Appropriate filtering of artifacts, to reveal the actual effect on muscle contraction elicited by vibration stimulus, is mandatory. However as a result of our preliminary study, a simple multi-band notch filtering may help to reduce randomness of the results. Muscle tuning hypothesis seemed to be confirmed. Our results suggested that the effects of WBV are linked to the actual muscle motion (displacement). The greater was the muscle belly displacement the higher was found the muscle activity. The maximum muscle activity has been found in correspondence with the local mechanical resonance, suggesting a more effective stimulation at the specific system resonance frequency. Holding the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization could be obtained by simply monitoring local acceleration (resonance). However, our study revealed some short term effects of vibratory stimulus; prolonged studies should be assembled in order to consider the long term effectiveness of these results. Since local stimulus depends on the kinematic chain involved, WBV muscle stimulation has to take into account the transmissibility of the stimulus along the body segment in order to ensure that vibratory stimulation effectively reaches the target muscle. Combination of local resonance and muscle response should also be further investigated to prevent hazards to individuals undergoing WBV treatments.
Resumo:
Within this work, a particle-polymer surface system is studied with respect to the particle-surface interactions. The latter are governed by micromechanics and are an important aspect for a wide range of industrial applications. Here, a new methodology is developed for understanding the adhesion process and measure the relevant forces, based on the quartz crystal microbalance, QCM. rnThe potential of the QCM technique for studying particle-surface interactions and reflect the adhesion process is evaluated by carrying out experiments with a custom-made setup, consisting of the QCM with a 160 nm thick film of polystyrene (PS) spin-coated onto the quartz and of glass particles, of different diameters (5-20µm), deposited onto the polymer surface. Shifts in the QCM resonance frequency are monitored as a function of the oscillation amplitude. The induced frequency shifts of the 3rd overtone are found to decrease or increase, depending on the particle-surface coupling type and the applied oscillation (frequency and amplitude). For strong coupling the 3rd harmonic decreased, corresponding to an “added mass” on the quartz surface. However, positive frequency shifts are observed in some cases and are attributed to weak-coupling between particle and surface. Higher overtones, i.e. the 5th and 7th, were utilized in order to derive additional information about the interactions taking place. For small particles, the shift for specific overtones can increase after annealing, while for large particle diameters annealing causes a negative frequency shift. The lower overtones correspond to a generally strong-coupling regime with mainly negative frequency shifts observed, while the 7th appears to be sensitive to the contact break-down and the recorded shifts are positive.rnDuring oscillation, the motion of the particles and the induced frequency shift of the QCM are governed by a balance between inertial forces and contact forces. The adherence of the particles can be increased by annealing the PS film at 150°C, which led to the formation of a PS meniscus. For the interpretation, the Hertz, Johnson-Kendall-Roberts, Derjaguin-Müller-Toporov and the Mindlin theory of partial slip are considered. The Mindlin approach is utilized to describe partial slip. When partial slip takes place induced by an oscillating load, a part of the contact ruptures. This results in a decrease of the effective contact stiffness. Additionally, there are long-term memory effects due to the consolidation which along with the QCM vibrations induce a coupling increase. However, the latter can also break the contact, lead to detachment and even surface damage and deformation due to inertia. For strong coupling the particles appear to move with the vibrations and simply act as added effective mass leading to a decrease of the resonance frequency, in agreement with the Sauerbrey equation that is commonly used to calculate the added mass on a QCM). When the system enters the weak-coupling regime the particles are not able to follow the fast movement of the QCM surface. Hence, they effectively act as adding a “spring” with an additional coupling constant and increase the resonance frequency. The frequency shift, however, is not a unique function of the coupling constant. Furthermore, the critical oscillation amplitude is determined, above which particle detach. No movement is detected at much lower amplitudes, while for intermediate values, lateral particle displacement is observed. rnIn order to validate the QCM results and study the particle effects on the surface, atomic force microscopy, AFM, is additionally utilized, to image surfaces and measure surface forces. By studying the surface of the polymer film after excitation and particle removal, AFM imaging helped in detecting three different meniscus types for the contact area: the “full contact”, the “asymmetrical” and a third one including a “homocentric smaller meniscus”. The different meniscus forms result in varying bond intensity between particles and polymer film, which could explain the deviation between number of particles per surface area measured by imaging and the values provided by the QCM - frequency shift analysis. The asymmetric and the homocentric contact types are suggested to be responsible for the positive frequency shifts observed for all three measured overtones, i.e. for the weak-coupling regime, while the “full contact” type resulted in a negative frequency shift, by effectively contributing to the mass increase of the quartz..rnThe interplay between inertia and contact forces for the particle-surface system leads to strong- or weak-coupling, with the particle affecting in three mentioned ways the polymer surface. This is manifested in the frequency shifts of the QCM system harmonics which are used to differentiate between the two interaction types and reflect the overall state of adhesion for particles of different size.rn
Resumo:
This thesis work aims to find a procedure for isolating specific features of the current signal from a plasma focus for medical applications. The structure of the current signal inside a plasma focus is exclusive of this class of machines and a specific analysis procedure has to be developed. The hope is to find one or more features that shows a correlation with the dose erogated. The study of the correlation between the current discharge signal and the dose delivered by a plasma focus could be of some importance not only for the practical application of dose prediction but also for expanding the knowledge anbout the plasma focus physics. Vatious classes of time-frequency analysis tecniques are implemented in order to solve the problem.
Resumo:
In patients diagnosed with pharmaco-resistant epilepsy, cerebral areas responsible for seizure generation can be defined by performing implantation of intracranial electrodes. The identification of the epileptogenic zone (EZ) is based on visual inspection of the intracranial electroencephalogram (IEEG) performed by highly qualified neurophysiologists. New computer-based quantitative EEG analyses have been developed in collaboration with the signal analysis community to expedite EZ detection. The aim of the present report is to compare different signal analysis approaches developed in four different European laboratories working in close collaboration with four European Epilepsy Centers. Computer-based signal analysis methods were retrospectively applied to IEEG recordings performed in four patients undergoing pre-surgical exploration of pharmaco-resistant epilepsy. The four methods elaborated by the different teams to identify the EZ are based either on frequency analysis, on nonlinear signal analysis, on connectivity measures or on statistical parametric mapping of epileptogenicity indices. All methods converge on the identification of EZ in patients that present with fast activity at seizure onset. When traditional visual inspection was not successful in detecting EZ on IEEG, the different signal analysis methods produced highly discordant results. Quantitative analysis of IEEG recordings complement clinical evaluation by contributing to the study of epileptogenic networks during seizures. We demonstrate that the degree of sensitivity of different computer-based methods to detect the EZ in respect to visual EEG inspection depends on the specific seizure pattern.
Resumo:
The current standard for temperature sensitive imaging using magnetic resonance (MR) is 2-D, spoiled, fast gradient-echo (fGRE) phase-difference imaging exploiting temperature dependent changes in the proton resonance frequency (PRF). The echo-time (TE) for optimal sensitivity is larger than the typical repetition time (TR) of an fGRE sequence. Since TE must be less than TR in the fGRE sequence, this limits the technique's achievable sensitivity, spatial, and temporal resolution. This adversely affects both accuracy and volume coverage of the measurements. Accurate measurement of the rapid temperature changes associated with pulsed thermal therapies, such as high-intensity focused ultrasound (FUS), at optimal temperature sensitivity requires faster acquisition times than those currently available. ^ Use of fast MR acquisition strategies, such as interleaved echo-planar and spiral imaging, can provide the necessary increase in temporal performance and sensitivity while maintaining adequate signal-to-noise and in-plane spatial resolution. This research explored the adaptation and optimization of several fast MR acquisition methods for thermal monitoring of pulsed FUS thermal therapy. Temperature sensitivity, phase-difference noise and phase-difference to phase-difference-to noise ratio for the different pulse sequences were evaluated under varying imaging parameters in an agar gel phantom to establish optimal sequence parameters for temperature monitoring. The temperature sensitivity coefficient of the gel phantom was measured, allowing quantitative temperature extrapolations. ^ Optimized fast sequences were compared based on the ability to accurately monitor temperature changes at the focus of a high-intensity focused ultrasound unit, volume coverage, and contrast-to-noise ratio in the temperature maps. Operating parameters, which minimize complex phase-difference measurement errors introduced by use of the fast-imaging methods, were established. ^
Resumo:
Durante los últimos años el flujo de datos en la transmisión que tiene lugar en los sistemas de comunicación ha aumentado considerablemente de forma que día a día se requieren más aplicaciones trabajando en un rango de frecuencias muy alto (3-30 GHz). Muchos de estos sistemas de comunicación incluyen dispositivos de onda acústica superficial (SAW) y por tanto se hace necesario el aumento de frecuencia a la que éstos trabajan. Pero este incremento de frecuencia de los dispositivos SAW no sólo es utilizado en los sistemas de comunicación, varios tipos de sensores, por ejemplo, aumentan su sensibilidad cuando la frecuencia a la que trabajan también lo hace. Tradicionalmente los dispositivos SAW se han fabricado sobre cuarzo, LiNbO3 y LiTaO3 principalmente. Sin embargo la principal limitación de estos materiales es su velocidad SAW. Además, debido a la alta temperatura a la que se depositan no pueden ser integrados en la tecnología de fabricación CMOS. El uso de la tecnología de capa delgada, en la que un material piezoeléctrico es depositado sobre un substrato, se está utilizando en las últimas décadas para incrementar la velocidad SAW de la estructura y poder obtener dispositivos trabajando en el rango de frecuencias requerido en la actualidad. Por otra parte, esta tecnología podría ser integrada en el proceso de fabricación CMOS. Durante esta tesis nos hemos centrado en la fabricación de dispositivos SAW trabajando a muy alta frecuencia. Para ello, utilizando la tecnología de capa delgada, hemos utilizado la estructura nitruro de aluminio (AlN) sobre diamante que permite conseguir velocidades SAW del sustrato que no se pueden alcanzar con otros materiales. El depósito de AlN se realizó mediante sputtering reactivo. Durante esta tesis se han realizado diferentes experimentos para optimizar dicho depósito de forma que se han obtenido los parámetros óptimos para los cuales se pueden obtener capas de AlN de alta calidad sobre cualquier tipo de sustrato. Además todo el proceso se realizó a baja temperatura para que el procesado de estos dispositivos pueda ser compatible con la tecnología CMOS. Una vez optimizada la estructura AlN/diamante, mediante litografía por haz de electrones se fabricaron resonadores SAW de tamaño nanométrico que sumado a la alta velocidad resultante de la combinación AlN/diamante nos ha permitido obtener dispositivos trabajando en el rango de 10-28 GHz con un alto factor de calidad y rechazo fuera de la banda. Estás frecuencias y prestaciones no han sido alcanzadas por el momento en resonadores de este tipo. Por otra parte, se han utilizado estos dispositivos para fabricar sensores de presión de alta sensibilidad. Estos dispositivos son afectados altamente por los cambios de temperatura. Se realizó también un exhaustivo estudio de cómo se comportan en temperatura estos resonadores, entre -250ºC y 250ºC (rango de temperaturas no estudiado hasta el momento) diferenciándose dos regiones una a muy baja temperatura en la que el dispositivo muestra un coeficiente de retraso en frecuencia (TCF) relativamente bajo y otra a partir de los -100ºC en la que el TCF es similar al observado en la bibliografía. Por tanto, durante esta tesis se ha optimizado el depósito de AlN sobre diamante para que sea compatible con la tecnología CMOS y permita el procesado de dispositivos trabajando a muy alta frecuencia con altas prestaciones para comunicaciones y sensores. ABSTRACT The increasing volume of information in data transmission systems results in a growing demand of applications working in the super-high-frequency band (3–30 GHz). Most of these systems work with surface acoustic wave (SAW) devices and thus there is a necessity of increasing their resonance frequency. Moreover, sensor application includes this kind of devices. The sensitivity of them is proportional with its frequency. Traditionally, quartz, LiNbO3 and LiTaO3 have been used in the fabrication of SAW devices. These materials suffer from a variety of limitations and in particular they have low SAW velocity as well as being incompatible with the CMOS technology. In order to overcome these problems, thin film technology, where a piezoelectric material is deposited on top of a substrate, has been used during the last decades. The piezoelectric/substrate structure allows to reach the frequencies required nowadays and could be compatible with the mass electronic production CMOS technology. This thesis work focuses on the fabrication of SAW devices working in the super-high-frequency range. Thin film technology has been used in order to get it, especially aluminum nitride (AlN) deposited by reactive sputtering on diamond has been used to increase the SAW velocity. Different experiments were carried out to optimize the parameters for the deposit of high quality AlN on any kind of substrates. In addition, the system was optimized under low temperature and thus this process is CMOS compatible. Once the AlN/diamond was optimized, thanks to the used e-beam lithography, nanometric SAW resonators were fabricated. The combination of the structure and the size of the devices allow the fabrication of devices working in the range of 10-28 GHz with a high quality factor and out of band rejection. These high performances and frequencies have not been reached so far for this kind of devices. Moreover, these devices have been used as high sensitivity pressure sensors. They are affected by temperature changes and thus a wide temperature range (-250ºC to 250ºC) study was done. From this study two regions were observed. At very low temperature, the temperature coefficient of frequency (TCF) is low. From -100ºC upwards the TCF is similar to the one appearing in the literature. Therefore, during this thesis work, the sputtering of AlN on diamond substrates was optimized for the CMOS compatible fabrication of high frequency and high performance SAW devices for communication and sensor application.
Resumo:
We have analyzed a resonant behavior in the dielectric constant associated to the barrier of YBa2Cu3O7 (YBCO) grain boundary Josephson junctions (GBJJs) fabricated on a wide variety of bicrystalline substrates: 12° [0 0 1] tilt asymmetric, 24° [0 0 1] tilt asymmetric, 24° [0 0 1] tilt symmetric, 24° [1 0 0] tilt asymmetric, 45° [1 0 0] tilt asymmetric and 24° [0 0 1] tilt symmetric +45° [1 0 0] tilt asymmetric bicrystals. The resonance analysis allows us to estimate a more appropriate value of the relative dielectric constant, and so a more adequate value for the length L of the normal N region assuming a SNINS model for the barrier. In this work, the L dependence on the critical current density Jc has been investigated. This analysis makes possible a single representation for all the substrate geometries independently on around which axes the rotation is produced to generate the grain boundary. On the other hand, no clear evidences exist on the origin of the resonance. The resonance frequency is in the order of 1011 Hz, pointing to a phonon dynamic influence on the resonance mechanism. Besides, its position is affected by the oxygen content of the barrier: a shift at low frequencies is observed when the misorientation angle increases.
Resumo:
The type of signals obtained has conditioned chaos analysis tools. Almost in every case, they have analogue characteristics. But in certain cases, a chaotic digital signal is obtained and theses signals need a different approach than conventional analogue ones. The main objective of this paper will be to present some possible approaches to the study of this signals and how information about their characteristics may be obtained in the more straightforward possible way. We have obtained digital chaotic signals from an Optical Logic Cell with some feedback between output and one of the possible control gates. This chaos has been reported in several papers and its characteristics have been employed as a possible method to secure communications and as a way to encryption. In both cases, the influence of some perturbation in the transmission medium gave problems both for the synchronization of chaotic generators at emitter and receiver and for the recovering of information data. A proposed way to analyze the presence of some perturbation is to study the noise contents of transmitted signal and to implement a way to eliminate it. In our present case, the digital signal will be converted to a multilevel one by grouping bits in packets of 8 bits and applying conventional methods of time-frequency analysis to them. The results give information about the change in signals characteristics and hence some information about the noise or perturbations present. Equivalent representations to the phase and to the Feigenbaum diagrams for digital signals are employed in this case.
Resumo:
Helicopters are one of the most important tactical elements in maritime operations. The necessity for an improvement in the conditions in which the landing and take-off operations are carried out leads to the study of the flow that separates from the ship?s superstructure over the flight deck. To investigate this flow a series of wind tunnel experiments have been performed by testing a sub-scale model of a generic frigate. Measurements of the flow?s velocity have been taken by means of Laser Doppler Anemometry (LDA) in five points that simulate the last path of the landing trajectory. The data obtained in these experiments is manipulated in a frequency analysis where the corresponding spectra are calculated. Onboard measurements from an actual full scale frigate are analyzed and compared with the wind tunnel results. Conclusions obtained consist of a series of illustrative values of turbulent energy frequency ranges which can be valuable for any study in this field. The comparison shows a clear similarity between both experiments, reasserting the wind tunnel measurements and its reliability.
Resumo:
La presente tesis revisa y analiza algunos aspectos fundamentales relativos al comportamiento de los sensores basados en resonadores piezoeléctricos TSM (Thickness Shear Mode), así como la aplicación de los mismos al estudio y caracterización de dos medios viscoelásticos de gran interés: los fluidos magnetoreológicos y los biofilms microbianos. El funcionamiento de estos sensores está basado en la medida de sus propiedades resonantes, las cuales varían al entrar en contacto con el material que se quiere analizar. Se ha realizado un análisis multifrecuencial, trabajando en varios modos de resonancia del transductor, en algunas aplicaciones incluso de forma simultánea (excitación pulsada). Se han revisado fenómenos como la presencia de microcontactos en la superficie del sensor y la resonancia de capas viscoelásticas de espesor finito, que pueden afectar a los sensores de cuarzo de manera contraria a lo que predice la teoría convencional (Sauerbrey y Kanazawa), pudiéndonos llevar a incrementos positivos de la frecuencia de resonancia. Además, se ha estudiado el efecto de una deposición no uniforme sobre el resonador piezoeléctrico. Para ello se han medido deposiciones de poliuretano, modelándose la respuesta del resonador con estas deposiciones mediante FEM. El modelo numérico permite estudiar el comportamiento del resonador al modificar distintas variables geométricas (espesor, superficie, no uniformidad y zona de deposición) de la capa depositada. Se ha demostrado que para espesores de entre un cuarto y media longitud de onda aproximadamente, una capa viscoelástica no uniforme sobre la superficie del sensor, amplifica el incremento positivo del desplazamiento de la frecuencia de resonancia en relación con una capa uniforme. Se ha analizado también el patrón geométrico de la sensibilidad del sensor, siendo también no uniforme sobre su superficie. Se han aplicado sensores TSM para estudiar los cambios viscoelásticos que se producen en varios fluidos magneto-reológicos (FMR) al aplicarles distintos esfuerzos de cizalla controlados por un reómetro. Se ha podido ver que existe una relación directa entre diversos parámetros reológicos obtenidos con el reómetro (fuerza normal, G’, G’’, velocidad de deformación, esfuerzo de cizalla…) y los parámetros acústicos, caracterizándose los FMR tanto en ausencia de campo magnético, como con campo magnético aplicado a distintas intensidades. Se han estudiado las ventajas que aporta esta técnica de medida sobre la técnica basada en un reómetro comercial, destacando que se consigue caracterizar con mayor detalle algunos aspectos relevantes del fluido como son la deposición de partículas (estabilidad del fluido), el proceso de ruptura de las estructuras formadas en los FMR tanto en presencia como en ausencia de campo magnético y la rigidez de los microcontactos que aparecen entre partículas y superficies. También se han utilizado sensores de cuarzo para monitorear en tiempo real la formación de biofilms de Staphylococcus epidermidis y Eschericia coli sobre los propios resonadores de cristal de cuarzo sin ningún tipo de recubrimiento, realizándose ensayos con cepas que presentan distinta capacidad de producir biofilm. Se mostró que, una vez que se ha producido una primera adhesión homogénea de las bacterias al sustrato, podemos considerar el biofilm como una capa semi-infinita, de la cual el sensor de cuarzo refleja las propiedades viscoelásticas de la región inmediatamente contigua al resonador, no siendo sensible a lo que sucede en estratos superiores del biofilm. Los experimentos han permitido caracterizar el módulo de rigidez complejo de los biofilms a varias frecuencias, mostrándose que el parámetro característico que indica la adhesión de un biofilm tanto en el caso de S. epidermidis como de E. coli, es el incremento de G’ (relacionado con la elasticidad o rigidez de la capa), el cual viene ligado a un incremento de la frecuencia de resonancia del sensor. ABSTRACT This thesis reviews and analyzes some key aspects of the behavior of sensors based on piezoelectric resonators TSM (Thickness Shear Mode) and their applications to the study and characterization in two viscoelastic media of great interest: magnetorheological fluids and microbial biofilms. The operation of these sensors is based on the analysis of their resonant properties that vary in contact with the material to be analyzed. We have made a multi-frequency analysis, working in several modes of resonance of the transducer, in some applications even simultaneously (by impulse excitation). We reviewed some phenomena as the presence of micro-contacts on the sensor surface and the resonance of viscoelastic layers of finite thickness, which can affect quartz sensors contrary to the conventional theory predictions (Sauerbrey and Kanazawa), leading to positive resonant frequency shifts. In addition, we studied the effect of non-uniform deposition on the piezoelectric resonator. Polyurethane stools have been measured, being the resonator response to these depositions modeled by FEM. The numerical model allows studying the behavior of the resonator when different geometric variables (thickness, surface non-uniformity and deposition zone) of the deposited layer are modified. It has been shown that for thicknesses between a quarter and a half of a wavelength approximately, non-uniform deposits on the sensor surface amplify the positive increase of the resonance frequency displacement compared to a uniform layer. The geometric pattern of the sensor sensitivity was also analyzed, being also non-uniform over its surface. TSM sensors have been applied to study the viscoelastic changes occurring in various magneto-rheological fluids (FMR) when subjected to different controlled shear stresses driven by a rheometer. It has been seen that there is a direct relationship between various rheological parameters obtained with the rheometer (normal force, G', G'', stress, shear rate ...) and the acoustic parameters, being the FMR characterized both in the absence of magnetic field, and when the magnetic field was applied at different intensities. We have studied the advantages of this technique over the characterization methods based on commercial rheometers, noting that TSM sensors are more sensitive to some relevant aspects of the fluid as the deposition of particles (fluid stability), the breaking process of the structures formed in the FMR both in the presence and absence of magnetic field, and the rigidity of the micro-contacts appearing between particles and surfaces. TSM sensors have also been used to monitor in real time the formation of biofilms of Staphylococcus epidermidis and Escherichia coli on the quartz crystal resonators themselves without any coating, performing tests with strains having different ability to produce biofilm. It was shown that, once a first homogeneous adhesion of bacteria was produced on the substrate, the biofilm can be considered as a semi-infinite layer and the quartz sensor reflects only the viscoelastic properties of the region immediately adjacent to the resonator, not being sensitive to what is happening in upper layers of the biofilm. The experiments allow the evaluation of the biofilm complex stiffness module at various frequencies, showing that the characteristic parameter that indicates the adhesion of a biofilm for the case of both S. epidermidis and E. coli, is an increased G' (related to the elasticity or stiffness of the layer), which is linked to an increase in the resonance frequency of the sensor.