915 resultados para QUANTITATIVE NANOTRIBOLOGY
Resumo:
Objective To determine whether the use of 3-dimensional (3D) imaging translates into a better surgical performance of naïve urologic laparoscopic surgeons during pyeloplasty (PY) and partial nephrectomy (PN) procedures. Materials and Methods Eighteen surgeons without any previous laparoscopic experience were randomly assigned to perform PY and PN in a porcine model using initially 2-dimensional (2D) and 3D laparoscopy. A surgical performance score was rated by an "expert" tutor through a modified 5-item global rating scale contemplating operative field view, bimanual dexterity, efficiency, tissue handling, and autonomy. Overall surgical time, complications, subjective perception of participating surgeons, and inconveniences related to the 3D vision were recorded. Results No difference in terms if operative time was found between 2D or 3D laparoscopy for both the PY (P =.51) and the PN (P =.28) procedures. A better rate in terms of surgical performance score was noted by the tutors when the study participants were using 3D vs 2D, for both PY (3.6 [0.8] vs 3.0 [0.4]; P =.034) and PN (3.6 [0.51] vs 3.15 [0.63]; P =.001). No complications occurred in any of the procedures. Most (77.2%) of the participating na??ve laparoscopic surgeons had the perception that 3D laparoscopy was overall easier than 2D. Headache (18.1%), nausea (18.1%), and visual disturbance (18.1%) were the most common issues reported by the surgeons during 3D procedures. Conclusion Despite the absence of translation in a shorter operative time, the use of 3D technology seems to facilitate the surgical performance of naive surgeons during laparoscopic kidney procedures on a porcine model.
Resumo:
OBJECTIVE: To study the quantitative changes in intramyocardial blood vessels in rats in whom nitric oxide synthesis was inhibited. METHODS: Four groups of 10 rats were studied: control (C25 and C40) and L-NAME (L25 and L40). The animals L25 and L40 received L-NAME in the dosage of 50mg/kg/day for 25 and 40 days, respectively. On days 26 and 41 the animals in groups 25 and 40 were sacrificed. Analysis of the myocardium was performed using light microscopy and stereology. RESULTS: Arterial blood pressure and heart weight increased 74.5 and 57.8% after 25 days and 90.2 and 34.6% after 40 days, respectively. Comparing the L-NAME rats with the respective controls revealed that vessel volume density decreased 31.3% after 40 days, and the vessel length-density decreased 53.5% after 25 days and 25.7% after 40 days. The mean cross-sectional area of the vessels showed an important reduction of 154.6% after 25 days. The intramyocardial vessels decreased significantly in length- density in the L-NAME animals. The mean cross-sectional area of the vessels, which normally increases during heart growth between 25 and 40 days, showed a precocious increase by the 25th day in the L-NAME rats. This suggests an increase of the size of the heart, including blood vessels. CONCLUSION: The inhibition of the NO synthesis provokes rarefaction in the intramyocardial vessels that progresses with the time of administration of L-NAME.
Resumo:
In this paper we propose to characterize the inclusive philosophy in Thailand as well as to present and discuss results from a quantitative research carried out within the teacher pre-service context, viewed as one of the components that should be addressed by school systems that seek to be inclusive.
Resumo:
OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (³12 to <16 atm) and group 2 (³16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (³12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (³16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.
Resumo:
OBJETIVO: Analisar as diferenças relacionadas ao sexo nas medidas obtidas pelos programas Segami e Quantitative Gated SPECT (QGS). MÉTODOS: Cento e oitenta e um indivíduos assintomáticos sem evidência de cardiopatia foram submetidos a estudos de perfusão miocárdica. O volume diastólico final (VDF), volume sistólico final (VSF) e a fração de ejeção do ventrículo esquerdo (FEVE) foram quantificados pelos programas QGS and Segami para avaliar a influência do sexo, idade, peso, altura, freqüência cardíaca, pressão arterial sistólica, pressão arterial diastólica, índice de massa corporal e área de superfície corporal. RESULTADOS: As médias obtidas com o método QGS foram VDF (mulheres = 68 ml; homens = 95 ml; p < 0,001) e FEVE (mulheres = 66,24%; homens = 58,7%), e com o Segami, VDF (mulheres = 137 ml; homens = 174 ml) e FEVE (mulheres = 62,67%; homens = 58,52%). Foram observadas diferenças significantes entre homens e mulheres no VDF (p < 0,001) e VSF (p < 0,001), que persistiram após o ajuste em relação à área de superfície corporal. CONCLUSÃO: Os volumes ventriculares foram significantemente menores e a FEVE foi significantemente maior em mulheres, de acordo com os programas QGS e Segami.
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2011
Resumo:
Robuste Regelung, Schwingungsregelung, Smart-Structures, Quantitative Feedback Theory, Optimierung
Resumo:
Background: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.
Resumo:
[s.c.]
Resumo:
Magdeburg, Univ., Med. Fak., Diss., 2015
Resumo:
This study represents one of the first contributions to the knowledge on the quantitative fidelity of the recent freshwater molluscan assemblages in subtropical rivers. Thanatocoenoses and biocoenoses were studied in straight and meandering to braided sectors, in the middle course of the Touro Passo River, a fourth-order tributary of the Uruguay River, located in the westernmost part of the State of Rio Grande do Sul. Samplings were carried out through quadrats of 5 m², five in each sector. A total area of 50 m² was sampled. Samplings were also made in a lentic environment (abandoned meander), with intermittent communication with the Touro Passo River, aiming to record out-of-habitat shell transportation from the lentic communities to the main river channel. The results show that, despite the frequent oscillation of the water level, the biocoenosis of the Touro Passo River shows high ecological fidelity and undergoes little influence from the lentic vicinal environments. The taxonomic composition and some features of the structure of communities, especially the dominant species, also reflect some ecological differences between the two main sectors sampled, such as the complexity of habitats in the meandering-sector. Regarding the quantitative fidelity, 60% of the species found alive were also found dead and 47.3% of the species found dead were also found alive, at river-scale. However, 72% of the dead individuals belong to species also found alive. This value might be related with the good rank order correlation obtained for live/dead assemblages. Consequently, the dominant species of the thanatocoenoses could be used to infer the ecological attributes of the biocoenoses. The values of all the indexes analyzed were very variable in small-scale samplings (quadrat), but were more similar to others registered in previous studies, when they were analyzed in a station and river scale.
Resumo:
Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge filter. The use of ferric hydroxide gel, impregnated on the surface of glassfibre cartridge filter enable us to recover 62.5% of virus (Poliomylitis type I, Lsc strain) exsogeneously added to 400 liters of tap-water. The virus concentrator system consists of four cartridge filters, in which the three first one are clarifiers, where the contaminants are removed physically, without significant virus loss at this stage. The last cartridge filter is impregnated with ferric hydroxide gel, where the virus is adsorbed. After the required volume of water has been processed, the last filter is removed from the system and the viruses are recovered from the gel, using 1 liter of glycine/NaOH buffer, at pH 11. Immediately the eluate is clarified through series of cellulose acetate membranes mounted in a 142mm Millipore filter. For the second step of virus concentration, HC1 1N is added slowly to the eluate to achieve pH 3.5-4. MgC1, is added to give a final concentration of 0.05M and the viruses are readsorbed on a 0.45 , porosity (HA) cellulose acetate membrane, mounted in a 90 mm Millipore filter. The viruses are recovered using the same eluent plus 10% of fetal calf serum, to a final volume of 3 ml. In this way, it was possible to concentrate virus from 400 liters of tap-water, into 1 liter in the first stage of virus concentration and just to 3 ml of final volume in a second step. The efficiency, simplicity and low operational cost, provded by the method, make it feasible to study viral pollution of recreational and tap-water sources.