417 resultados para Porcelain veneer
Resumo:
Purpose: The objective of this study was to verify the influence of test environment on the flexural strength of dental porcelains with distinct microstructures. Material and Methods: Disk-shaped specimens from three dental porcelains with distinct leucite content (VM: zero; CE: 12; NS: 22 vol%) were manufactured and tested for biaxial flexural strength in air and immersed in artificial saliva. The results were analyzed by means of two-way ANOVA and Tukey`s test (alpha = 0.05). Results: The flexural strength (MPa) obtained for ambient air and artificial saliva environments, respectively, were: 110.0 +/- 16.0 and 81.5 +/- 10.8 for VM; 51.9 +/- 4.0 and 42.0 +/- 4.7 for CE; 72.0 +/- 11.5 and 63.6 +/- 5.8 for NS. A numerical decrease in the mean flexural strength was observed for all groups when specimens were tested under artificial saliva; however, the difference was only statistically significant for VM. Conclusions: The results indicate that the effect of water immersion on the flexural strength of dental porcelains varies according to their leucite content, as only the material without leucite in its microstructure (VM) showed significant strength degradation when tested under water.
Resumo:
This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.
Resumo:
Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.
Resumo:
This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.
Resumo:
To study luminescence, reflectance, and color stability of dental composites and ceramics. Materials and Methods: IPS e.max, IPS Classic, Gradia, and Sinfony materials were tested, both unpolished (as-cast) and polished specimens. Coffee, tea, red wine, and distilled water (control) were used as staining drinks. Disk-shaped specimens were soaked in the staining drinks for up to 5 days. Color was measured by a colorimeter. Fluorescence was recorded using a spectrofluorometer, in the front-face geometry. Time-resolved fluorescence spectra were recorded using a laser nanosecond spectrofluorometer. Results: The exposure of the examined dental materials to staining drinks caused changes in color of the composites and ceramics, with the polished specimens exhibiting significantly lower color changes as compared to unpolished specimens. Composites exhibited lower color stability as compared to ceramic materials. Water also caused perceptible color changes in most materials. The materials tested demonstrated significantly different initial luminescence intensities. Upon exposure to staining drinks, luminescence became weaker by up to 40%, dependent on the drink and the material. Time-resolved luminescence spectra exhibited some red shift of the emission band at longer times, with the lifetimes in the range of tens of nanoseconds. Conclusions: Unpolished specimens with a more developed surface have lower color stability. Specimens stored in water develop some changes in their visual appearance. The presently proposed methods are effective in evaluating the luminescence of dental materials. Luminescence needs to be tested in addition to color, as the two characteristics are uncorrelated. It is important to further improve the color and luminescence stability of dental materials.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica
Resumo:
The tropical tree Schizolobium amazonicum is native from the Amazonian forest, naturally occurring in Brazil, Peru and Colombia. This work aimed to study the veneer yield made from this species. For this purpose, 50 logs from S. amazonicum were rotary peeled in a plywood industry installed in Brazilian Amazon region. The results indicated that S. amazonicum had a peeling yield similar or even higher than those usually obtained for species traditionally used for this purpose in Brazil, like those of Pinus and Eucalyptus. It was also observed that the dendrometric parameters of the log can be used to estimate the peeling yield in this species.
Resumo:
Purpose. This study was conducted to determine whether newer infrared or laser welding technologies created joints superior to traditional furnace or torch soldering methods of joining metals. It was designed to assess the mechanical resistance, the characteristics of the fractured surfaces, and the elemental diffusion of joints obtained by four different techniques: (1) preceramic soldering with a propane-oxygen torch, (2) postceramic soldering with a porcelain furnace, (3) preceramic and (4) postceramic soldering with an infrared heat source, and (5) laser welding. Material and methods. Mechanical resistance was determined by measuring the ultimate tensile strength of the joint and by determining their resistance to fatigue loading. Elemental diffusion to and from the joint was assessed with microprobe tracings. Scanning electron microscopy micrographs of the fractured surface were also obtained and evaluated. Results. Under monotonic tensile stress, three groups emerged: The laser welds were the strongest, the preceramic joints ranged second, and the postceramic joints were the weakest. Under fatigue stress, the order was as follows: first, the preceramic joints, and second, a group that comprised both postceramic joints and the laser welds. Inspection of the fractographs revealed several fracture modes but no consistent pattern emerged. Microprobe analyses demonstrated minor diffusion processes in the preceramic joints, whereas significant diffusion was observed in the postceramic joints. Clinical Implications. The mechanical resistance data conflicted as to the strength that could be expected of laser welded joints. On the basis of fatigue resistance of the joints, neither infrared solder joints nor laser welds were stronger than torch or furnace soldered joints.
Resumo:
OBJECTIVES: Transcatheter aortic valve replacement (TAVR) provides good results in selected high-risk patients. However, it is unclear whether this procedure carries advantages in extreme-risk profile patients with logistic EuroSCORE above 35%. METHODS: From January 2009 to July 2011, of a total number of 92 transcatheter aortic valve procedures performed, 40 'extreme-risk' patients underwent transapical TAVR (TA-TAVR) (EuroSCORE above 35%). Variables were analysed as risk factors for hospital and mid-term mortality, and a 2-year follow-up (FU) was obtained. RESULTS: The mean age was: 81 ± 10 years. Twelve patients (30%) had chronic pulmonary disease, 32 (80%) severe peripheral vascular disease, 14 (35%) previous cardiac surgery, 19 (48%) chronic renal failure (2 in dialysis), 7 (17%) previous stroke (1 with disabilities), 3 (7%) a porcelain aorta and 12 (30%) were urgent cases. Mean left ventricle ejection fraction (LVEF) was 49 ± 13%, and mean logistic EuroSCORE was 48 ± 11%. Forty stent-valves were successfully implanted with six Grade-1 and one Grade-2 paravalvular leakages (success rate: 100%). Hospital mortality was 20% (8 patients). Causes of death following the valve academic research consortium (VARC) definitions were: life-threatening haemorrhage (1), myocardial infarction (1), sudden death (1), multiorgan failure (2), stroke (1) and severe respiratory dysfunction (2). Major complications (VARC definitions) were: myocardial infarction for left coronary ostium occlusion (1), life-threatening bleeding (2), stroke (2) and acute kidney injury with dialysis (2). Predictors for hospital mortality were: conversion to sternotomy, life-threatening haemorrhage, postoperative dialysis and long intensive care unit (ICU) stay. Variables associated with hospital mortality were: conversion to sternotomy (P = 0.03), life-threatening bleeding (P = 0.02), acute kidney injury with dialysis (P = 0.03) and prolonged ICU stay (P = 0.02). Mean FU time was 24 months: actuarial survival estimates for all-cause mortality at 6 months, 1 year, 18 months and 2 years were 68, 57, 54 and 54%, respectively. Patients still alive at FU were in good clinical condition, New York Heart Association (NYHA) class 1-2 and were never rehospitalized for cardiac decompensation. CONCLUSIONS: TA-TAVR in extreme-risk patients carries a moderate risk of hospital mortality. Severe comorbidities and presence of residual paravalvular leakages affect the mid-term survival, whereas surviving patients have an acceptable quality of life without rehospitalizations for cardiac decompensation.
Resumo:
Two goals were pursued in this research: first, to evaluate statistically some effects of sample preparation and instrument geometry on reproducibility of X-ray diffraction intensity data; and second, to develop a procedure for finding minimum peak and background counting times for a desired level of accuracy. The ratio of calcite to dolomite in limestones was determined in trials. Ultra-fine wet grinding of the limestone in porcelain impact type ball mill gave most consistent X-ray results, but caused considerable line broadening, and peaks were best measured on an area count basis. Sample spinning reduced variance about one third, and a coarse beam-medium detector slit arrangement was found to be best. An equation is developed relating coefficient of variation of a count ratio to peak and background counts. By use of the equation or graphs the minimum coefficient of variation is predicted from one fast scan, and the number and optimum arrangement of additional counting periods to reduce variation to a desired limit may be obtained. The calculated coefficient is the maximum which may be attributed to the counting statistic but does not include experimental deviations.
Resumo:
Vanerin tai kertopuun valmistusprosessissaviilun kuivaukseen käytetään suurin osa koko valmistusprosessin primäärienergiasta. Viilunkuivauskoneessa viilun sisältämä vesi siirretään tyypillisesti prosessihöyryllä lämmitettyyn viilunkuivaajan kiertoilmaan höyrystämällä ja poistetaanviilunkuivaajasta poistoilman mukana. Viilunkuivaajan poistoilma on lämmintä jaerittäin suuren kosteuspitoisuutensa takia sisältää runsaasti energiaa. Tyypillisellä viilunkuivaajalla poistoilmaan sitoutunut lämpöteho vaihtelee prosessiolosuhteista riippuen välillä 2,7-5,7 MW. Diplomityössä tutkittiin viilunkuivaajan poistoilman sisältämän lämmön talteenottoa laitteistolla, johon kuuluu lämmöntalteenottopesuri, jossa poistoilmalla lämmitetään tuotantolaitoksen tukkipuun hautomon kiertovettä sekä ilma-ilma-lämmönsiirrin, jolla lämmitetään pesurista poistuvan ilman jäännöslämmöllä ulkoilmaa tehdassalin tuloilmakäyttöön. Työn tavoitteena oli kehittää lämmöntalteenottojärjestelmän suunnittelua, mitoitusta ja ajotapoja. Työssä analysoitiin teoreettisesti pesuria ja ilmalämmönsiirrintä, kehitettiin lämmöntalteenottopesurin simulointimenetelmä ja mitattiin toiminnassa olevia talteenottolaitteistoja. Tutkimuksessa todettiin lämmöntalteenottohyötysuhteen vaihtelevan lämmityskaudella välillä 50-70 %. Lämmöntalteenottolaitteiston pesurin veteen saatava teho riippuu ensisijaisesti viilunkuivaajan poistoilman lämpösisällöstä, joka on enimmäkseen kosteusriippuvainen ja ilmanvaihtoilmaan saatava teho ulkolämpö-tilan määräämästä tehontarpeesta. Pesurin vesijärjestelmän vaikutusmekanismit pesurin suorituskykyyn tunnistettiin ja niiden pohjalta annetaan suositukset mitoitukseen ja ajotapaan. Lämmöntalteenottolaitteiston lämpötehon tasapainottamiseen pesurin ja ilma-ilma-lämmönsiirtimen välillä mitoituksen avulla esitellään työkalut.
Resumo:
Diplomityössä tutkittiin muotopuristeissa käytettävien viilujen soveltuvuutta yhteistyöyrityksen, VK Valmiskaluste Oy:n, valmistaman lepotuolin materiaaliksi. Tuoliaihion muoto edellytti viilun taivuttamista kahteen suuntaan, eli kyseessä oli ns. 3D-muoto. Muotopuristeita valmistavissa yrityksissä tehtyjen haastattelujen perusteella valittiin viilumateriaalit ja mitattiin niiden murtovenymä. Materiaaleja testattiin puristamalla tuoliaihioita. Aihionmuoto edellytti viilulta vähintään 3,3 %:n venyvyyttä. Koepuristuksetvahvistivat murtovenymätestauksen tulokset, eli tutkitun aihion pintarakenne säilyi ehjänä käyttämällä paperitaustaista viilua tai 3D-muotoihin tarkoitettua 3D-viilua. Kirjallisuusosiossa on selvitetty taivutettavuuteen vaikuttavia tekijöitä ja viilun rakenteen muokkausta taivutettavuuden parantamiseksi .