911 resultados para Minimally Invasive Surgical Procedures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To reduce the surgical trauma to the patient, minimally invasive surgery is gaining considerable importance since the eighties. More recently, robot assisted minimally invasive surgery was introduced to enhance the surgeon's performance in these procedures. This resulted in an intensive research on the design, fabrication and control of surgical robots over the last decades. A new development in the field of surgical tool manipulators is presented in this article: a flexible manipulator with distributed degrees of freedom powered by microhydraulic actuators. The tool consists of successive flexible segments, each with two bending degrees of freedom. To actuate these compliant segments, dedicated fluidic actuators are incorporated, together with compact hydraulic valves which control the actuator motion. Especially the development of microvalves for this application was challenging, and are the main focus of this paper. The valves distribute the hydraulic power from one common high pressure supply to a series of artificial muscle actuators. Tests show that the angular stroke of the each segment of this medical instrument is 90°. © 2012 Springer Science+Business Media, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine the epidemiological characteristics of postoperative invasive Staphylococcus aureus infection following 4 types of major surgical procedures.design. Retrospective cohort study. SETTING: Eleven hospitals (9 community hospitals and 2 tertiary care hospitals) in North Carolina and Virginia. PATIENTS: Adults undergoing orthopedic, neurosurgical, cardiothoracic, and plastic surgical procedures. METHODS: We used previously validated, prospectively collected surgical surveillance data for surgical site infection and microbiological data for bloodstream infection. The study period was 2003 through 2006. We defined invasive S. aureus infection as either nonsuperficial incisional surgical site infection or bloodstream infection. Nonparametric bootstrapping was used to generate 95% confidence intervals (CIs). P values were generated using the Pearson chi2 test, Student t test, or Wilcoxon rank-sum test, as appropriate. RESULTS: In total, 81,267 patients underwent 96,455 procedures during the study period. The overall incidence of invasive S. aureus infection was 0.47 infections per 100 procedures (95% CI, 0.43-0.52); 227 (51%) of 446 infections were due to methicillin-resistant S.aureus. Invasive S. aureus infection was more common after cardiothoracic procedures (incidence, 0.79 infections per 100 procedures [95%CI, 0.62-0.97]) than after orthopedic procedures (0.37 infections per 100 procedures [95% CI, 0.32-0.42]), neurosurgical procedures (0.62 infections per 100 procedures [95% CI, 0.53-0.72]), or plastic surgical procedures (0.32 infections per 100 procedures [95% CI, 0.17-0.47]) (P < .001). Similarly, S. aureus bloodstream infection was most common after cardiothoracic procedures (incidence, 0.57 infections per 100 procedures [95% CI, 0.43-0.72]; P < .001, compared with other procedure types), comprising almost three-quarters of the invasive S. aureus infections after these procedures. The highest rate of surgical site infection was observed after neurosurgical procedures (incidence, 0.50 infections per 100 procedures [95% CI, 0.42-0.59]; P < .001, compared with other procedure types), comprising 80% of invasive S.aureus infections after these procedures. CONCLUSION: The frequency and type of postoperative invasive S. aureus infection varied significantly across procedure types. The highest risk procedures, such as cardiothoracic procedures, should be targeted for ongoing preventative interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Operative treatment of coronoid fracture often requires a large dissection of soft tissue, resulting in elbow stiffness and functional limitation. The authors present a minimal invasive, safe technique, useful in the case of isolated coronoid fracture associated with elbow dislocation. This technique does not require soft tissue dissection and allows an early unlimited resumption of sports activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Articular cartilage lesions, with their inherent limited healing potential, are hard to treat and remain a challenging problem for orthopedic surgeons. Despite the development of several treatment strategies, the real potential of each procedure in terms of clinical benefit and effects on the joint degeneration processes is not clear. Aim of this PhD project was to evaluate the results, both in terms of clinical and imaging improvement, of new promising procedures developed to address the challenging cartilage pathology. Several studies have been followed in parallel and completed over the 3-year PhD, and are reported in detail in the following pages. In particular, the studies have been focused on the evaluation of the treatment indications of a scaffold based autologous chondrocyte implantation procedure, documenting its results for the classic indication of focal traumatic lesions, as well as its use for the treatment of more challenging patients, older, with degenerative lesions, or even as salvage procedure for more advanced stages of articular degeneration. The second field of study involved the analysis of the results obtained treating lesions of the articular surface with a new biomimetic osteochondral scaffold, which showed promise for the treatment of defects where the entire osteochondral unit is involved. Finally, a new minimally invasive procedure based on the use of growth factors derived from autologous platelets has been explored, showing results and underlining indicatios for the treatment of cartilage lesions and different stages of joint degeneration. These studies shed some light on the potential of the evaluated procedures, underlining good results as well as limits, they give some indications on the most appropriate candidates for their application, and document the current knowledge on cartilage treatment procedures suggesting the limitations that need to be addressed by future studies to improve the management of cartilage lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE : For the facilitation of minimally invasive robotically performed direct cochlea access (DCA) procedure, a surgical planning tool which enables the surgeon to define landmarks for patient-to-image registration, identify the necessary anatomical structures and define a safe DCA trajectory using patient image data (typically computed tomography (CT) or cone beam CT) is required. To this end, a dedicated end-to-end software planning system for the planning of DCA procedures that addresses current deficiencies has been developed. METHODS :    Efficient and robust anatomical segmentation is achieved through the implementation of semiautomatic algorithms; high-accuracy patient-to-image registration is achieved via an automated model-based fiducial detection algorithm and functionality for the interactive definition of a safe drilling trajectory based on case-specific drill positioning uncertainty calculations was developed. RESULTS :    The accuracy and safety of the presented software tool were validated during the conduction of eight DCA procedures performed on cadaver heads. The plan for each ear was completed in less than 20 min, and no damage to vital structures occurred during the procedures. The integrated fiducial detection functionality enabled final positioning accuracies of [Formula: see text] mm. CONCLUSIONS :    Results of this study demonstrated that the proposed software system could aid in the safe planning of a DCA tunnel within an acceptable time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Acute leg ischaemia (ALI) is a common vascular emergency for which new minimally invasive treatment options were introduced in the 1990s. The aim of this study was to determine recent hospital trends for ALI in England and to assess whether the introduction of the new treatment modalities had affected management. METHODS Routine hospital data covering ALI were provided by Hospital Episode Statistics for the years 2000 to 2011 and mortality data were obtained from the Office for National Statistics. All data were age standardised, reported per 100,000 of the population, and stratified by age band (60-74 years and ≥75 years) and sex. RESULTS Hospital admissions have risen significantly from 60.3 to 94.3 per 100,000 of the population, with an average annual increase of 6.2% since 2003 (p<0.001). The rise was greater in the older age group (from 79.9 to 134.4 vs 49.3 to 73.0) and yet procedures for ALI have shown a significant decrease since 2000 from 14.3 to 12.4 per 100,000 (p=0.013), independent of age and sex. Open embolectomy of the femoral artery remains the most common procedure and the proportion of endovascular interventions showed only a small increase. Only a few deaths were attributed to ALI (range: 95-150 deaths per year). CONCLUSIONS Hospital workload for ALI has increased, particularly since 2003, but this trend does not appear to have translated into increased endovascular or surgical activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Colonic lipomas larger than 2 cm in diameter are likely to be symptomatic. In some cases a complication is the first clinical sign. Massive lower intestinal bleeding or obstruction, acute bleeding, prolapse or perforation or, rarely, acute intussusception with intestinal obstruction require urgent surgery. Diagnosis is often made following colonoscopy, which can also have a therapeutic role. Imaging procedures such as CT has a secondary role. Patients with small asymptomatic colonic lipomas need regular follow up. For larger (diameter > 2 cm) and/or symptomatic lipomas, resection should be considered, although the choice between endoscopic or surgical resection remains controversial. We believe that even lipomas > 2 cm can safely be removed by endoscopic resection. If surgery is indicated, we consider laparoscopy to be the ideal approach in all patients for whom minimally invasive surgery is not contraindicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteoporosis is a disease characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis affects over 200 million people worldwide, with an estimated 1.5 million fractures annually in the United States alone, and with attendant costs exceeding $10 billion dollars per annum. Osteoporosis reduces bone density through a series of structural changes to the honeycomb-like trabecular bone structure (micro-structure). The reduced bone density, coupled with the microstructural changes, results in significant loss of bone strength and increased fracture risk. Vertebral compression fractures are the most common type of osteoporotic fracture and are associated with pain, increased thoracic curvature, reduced mobility, and difficulty with self care. Surgical interventions, such as kyphoplasty or vertebroplasty, are used to treat osteoporotic vertebral fractures by restoring vertebral stability and alleviating pain. These minimally invasive procedures involve injecting bone cement into the fractured vertebrae. The techniques are still relatively new and while initial results are promising, with the procedures relieving pain in 70-95% of cases, medium-term investigations are now indicating an increased risk of adjacent level fracture following the procedure. With the aging population, understanding and treatment of osteoporosis is an increasingly important public health issue in developed Western countries. The aim of this study was to investigate the biomechanics of spinal osteoporosis and osteoporotic vertebral compression fractures by developing multi-scale computational, Finite Element (FE) models of both healthy and osteoporotic vertebral bodies. The multi-scale approach included the overall vertebral body anatomy, as well as a detailed representation of the internal trabecular microstructure. This novel, multi-scale approach overcame limitations of previous investigations by allowing simultaneous investigation of the mechanics of the trabecular micro-structure as well as overall vertebral body mechanics. The models were used to simulate the progression of osteoporosis, the effect of different loading conditions on vertebral strength and stiffness, and the effects of vertebroplasty on vertebral and trabecular mechanics. The model development process began with the development of an individual trabecular strut model using 3D beam elements, which was used as the building block for lattice-type, structural trabecular bone models, which were in turn incorporated into the vertebral body models. At each stage of model development, model predictions were compared to analytical solutions and in-vitro data from existing literature. The incremental process provided confidence in the predictions of each model before incorporation into the overall vertebral body model. The trabecular bone model, vertebral body model and vertebroplasty models were validated against in-vitro data from a series of compression tests performed using human cadaveric vertebral bodies. Firstly, trabecular bone samples were acquired and morphological parameters for each sample were measured using high resolution micro-computed tomography (CT). Apparent mechanical properties for each sample were then determined using uni-axial compression tests. Bone tissue properties were inversely determined using voxel-based FE models based on the micro-CT data. Specimen specific trabecular bone models were developed and the predicted apparent stiffness and strength were compared to the experimentally measured apparent stiffness and strength of the corresponding specimen. Following the trabecular specimen tests, a series of 12 whole cadaveric vertebrae were then divided into treated and non-treated groups and vertebroplasty performed on the specimens of the treated group. The vertebrae in both groups underwent clinical-CT scanning and destructive uniaxial compression testing. Specimen specific FE vertebral body models were developed and the predicted mechanical response compared to the experimentally measured responses. The validation process demonstrated that the multi-scale FE models comprising a lattice network of beam elements were able to accurately capture the failure mechanics of trabecular bone; and a trabecular core represented with beam elements enclosed in a layer of shell elements to represent the cortical shell was able to adequately represent the failure mechanics of intact vertebral bodies with varying degrees of osteoporosis. Following model development and validation, the models were used to investigate the effects of progressive osteoporosis on vertebral body mechanics and trabecular bone mechanics. These simulations showed that overall failure of the osteoporotic vertebral body is initiated by failure of the trabecular core, and the failure mechanism of the trabeculae varies with the progression of osteoporosis; from tissue yield in healthy trabecular bone, to failure due to instability (buckling) in osteoporotic bone with its thinner trabecular struts. The mechanical response of the vertebral body under load is highly dependent on the ability of the endplates to deform to transmit the load to the underlying trabecular bone. The ability of the endplate to evenly transfer the load through the core diminishes with osteoporosis. Investigation into the effect of different loading conditions on the vertebral body found that, because the trabecular bone structural changes which occur in osteoporosis result in a structure that is highly aligned with the loading direction, the vertebral body is consequently less able to withstand non-uniform loading states such as occurs in forward flexion. Changes in vertebral body loading due to disc degeneration were simulated, but proved to have little effect on osteoporotic vertebra mechanics. Conversely, differences in vertebral body loading between simulated invivo (uniform endplate pressure) and in-vitro conditions (where the vertebral endplates are rigidly cemented) had a dramatic effect on the predicted vertebral mechanics. This investigation suggested that in-vitro loading using bone cement potting of both endplates has major limitations in its ability to represent vertebral body mechanics in-vivo. And lastly, FE investigation into the biomechanical effect of vertebroplasty was performed. The results of this investigation demonstrated that the effect of vertebroplasty on overall vertebra mechanics is strongly governed by the cement distribution achieved within the trabecular core. In agreement with a recent study, the models predicted that vertebroplasty cement distributions which do not form one continuous mass which contacts both endplates have little effect on vertebral body stiffness or strength. In summary, this work presents the development of a novel, multi-scale Finite Element model of the osteoporotic vertebral body, which provides a powerful new tool for investigating the mechanics of osteoporotic vertebral compression fractures at the trabecular bone micro-structural level, and at the vertebral body level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Paediatric Spine Research group was formed in 2002 to perform high quality research into the prevention and management of spinal deformity, with an emphasis on scoliosis. The group has successfully built collaborative bridges between the scientific and research expertise at QUT, and the clinical skills and experience of the spinal orthopaedic surgeons at the Mater Children’s Hospital in Brisbane. Clinical and biomechanical research is now possible as a result of the development of detailed databases of patients who have innovative and unique surgical interventions for spinal deformity such as thoracoscopic scoliosis correction, thoracoscopic staple insertion for juvenile idiopathic scoliosis and minimally invasive growing rods. The Mater in Brisbane provides these unique datasets of spinal deformity surgery patients, whose procedures are not being performed anywhere else in the Southern Hemisphere. The most detailed is a database of thoracoscopic scoliosis correction surgery which now contains 180 patients with electronic collections of X-Rays, photographs and patient questionnaires. With ethics approval, a subset of these patients has had CT scans, and a further subset have had MRI scans with and without a compressive load to simulate the erect standing position. This database has to date contributed to 17 international refereed journal papers, a further 7 journal papers either under review or in final preparation, 53 national conference presentations and 35 international conference presentations. Major findings from selected journal publications will be presented. It is anticipated that as the surgical databases grow they will continue to provide invaluable clinical data which will feed into clinically relevant projects driven by both medical and engineering researchers whose findings will benefit spinal deformity patients and scientific knowledge worldwide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background A large animal model is required for assessment of minimally invasive, tissue engineering based approaches to thoracic spine fusion, with relevance to deformity correction surgery for human adolescent idiopathic scoliosis. Here we develop a novel open mini–thoracotomy approach in an ovine model of thoracic interbody fusion which allows assessment of various fusion constructs, with a focus on novel, tissue engineering based interventions. Methods The open mini-thoracotomy surgical approach was developed through a series of mock surgeries, and then applied in a live sheep study. Customized scaffolds were manufactured to conform with intervertebral disc space clearances required of the study. Twelve male Merino sheep aged 4 to 6 years and weighing 35 – 45 kg underwent the abovementioned procedure and were divided into two groups of six sheep at survival timelines of 6 and 12 months. Each sheep underwent a 3-level discectomy (T6/7, T8/9 and T10/11) with randomly allocated implantation of a different graft substitute at each of the three levels; (i) polycaprolactone (PCL) based scaffold plus 0.54μg rhBMP-2, (ii) PCL-based scaffold alone or (iii) autograft. The sheep were closely monitored post- operatively for signs of pain (i.e. gait abnormalities/ teeth gnawing/ social isolation). Fusion assessments were conducted post-sacrifice using Computed Tomography and hard-tissue histology. All scientific work was undertaken in accordance with the study protocol has been approved by the Institute's committee on animal research. Results. All twelve sheep were successfully operated on and reached the allotted survival timelines, thereby demonstrating the feasibility of the surgical procedure and post-operative care. There were no significant complications and during the post-operative period the animals did not exhibit marked signs of distress according to the described assessment criteria. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL-based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluation of the respective groups. Conclusion. This novel open mini-thoracotomy surgical approach to the ovine thoracic spine represents a safe surgical method which can reproducibly form the platform for research into various spine tissue engineered constructs (TEC) and their fusion promoting properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Urinary incontinence is a common problem, affecting one third of the women at least at some time during their lives. The prevalence of urinary incontinence increases with advancing age, and the everyday impact of incontinence on women and on health services is enormous. Urinary incontinence is usually divided into three different subtypes, of which stress urinary incontinence (SUI) is the most common. Surgical treatment is often needed to cure SUI, and modern mid-urethral sling procedures give the possibility to cure this condition with a low risk of adverse events, a problem often associated with the so-called traditional incontinence operations. Life expectancy among women in Western countries has grown beyond 80 years of age. Long-term efficacy of treatment options for urinary incontinence therefore becomes an important issue in a world with limited eco-nomic resources. The purpose of the present study was to prospectively evaluate the long-term efficacy and safety of the first minimally invasive mid-urethral tape procedure, the Tension-free Vaginal Tape (TVT) procedure. The long-term (5-year) follow-up results of the TVT procedure as a repeat operation af-ter an unsuccessful mid-urethral tape operation were studied and the reasons for failure of the first operation were analyzed. Another purpose was to compare the original TVT procedure with a newer modification, the Tension-free Vaginal Tape Obturator (TVT-O) procedure within a multi-centre, randomized context in order to find out possible differences between these procedures re-garding efficacy and complications and the effects on symptoms of urgency. The first study of the present thesis is a prospective, Nordic, three-centre follow-up study of 90 women suffering from SUI, who were treated by means of the TVT procedure. The mean follow-up time was more than eleven years, and the study is the first to be published in connection with more than ten years of follow-up. The second study is a retrospective analysis of 26 women who were treated with a repeat TVT procedure after an unsuccessful primary mid-urethral tape procedure. The third and fourth studies concern 273 women in seven centres in Finland who were ran-domly assigned to the TVT and TVT-O procedures, the 3-year follow-up results of which are pre-sented in this thesis. After eleven years of follow-up, 90% of the women had a negative cough stress test result and a negative 24-h pad test result. The subjective cure rate measured as the women s global impression of cure was 77%, the rate of improvement 20%, and only 3% thought that the treatment had failed. No late-onset adverse effects were found. The repeat TVT procedure was successful in 75% of the cases when women who were cured and women who were significantly improved were included. The reasons for failure of the first operation could be separated into four different groups: tape material-related, operation technique-related, concomitant illness-related and a group with no identifiable reason. There were no intra-operative complications during the repeat operation. In the randomized trial comparing the TVT with the TVT-O procedure a cough stress test results were negative in 94.6% and 89.5% of the women in the two groups, respectively, after a 3-year follow-up period. There were no statistical differences in the cure rate or the rate of complications be-tween the two procedures. Symptoms of urgency were analyzed more closely and the main finding was that the prevalence of urgency symptoms decreased significantly after both mid-urethral sling procedures. The TVT operation was found to be an effective and safe procedure even after eleven years of follow-up. Long-term follow-up after a repeat TVT procedure revealed that the TVT procedure can well be considered after an unsuccessful mid-urethra tape procedure, because 75% of the patients showed significantly improvement of their incontinence. The TVT and TVT-O procedures showed no statistically significant differences in efficacy and rate of complications after three years of follow-up. In most cases these procedures alleviate preoperative symptoms of urgency and the risk of developing de novo urgency is low.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arteries are heterogeneous, composite structures that undergo large cyclic deformations during blood transport. Presence, build-up and consequent rupture of blockages in blood vessels, called atherosclerotic plaques, lead to disruption in the blood flow that can eventually be fatal. Abnormal lipid profile and hypertension are the main risk factors for plaque progression. Treatments span from pharmacological methods, to minimally invasive balloon angioplasty and stent procedures, and finally to surgical alternatives. There is a need to understand arterial disease progression and devise methods to detect, control, treat and manage arterial disease through early intervention. Local delivery through drug eluting stents also provide an attractive option for maintaining vessel integrity and restoring blood flow while releasing controlled amount of drug to reduce and alleviate symptoms. Development of drug eluting stents is hence interesting albeit challenging because it requires an integration of knowledge of mechanical properties with material transport of drug through the arterial wall to produce a desired biochemical effect. Although experimental models are useful in studying such complex multivariate phenomena, numerical models of mass transport in the vessel have proved immensely useful to understand and delineate complex interactions between chemical species, physical parameters and biological variables. The goals of this review are to summarize literature based on studies of mass transport involving low density lipoproteins in the arterial wall. We also discuss numerical models of drug elution from stents in layered and porous arterial walls that provide a unique platform that can be exploited for the design of novel drug eluting stents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O carcinoma epidermóide de pênis (CEP) representa 95% das neoplasias penianas e afeta quase sempre pacientes não circuncidados estando muitas vezes associado à falta de higiene local adequada e à fimose. No Brasil a sua incidência é de 2,7 % porém em algumas áreas do país pode chegar a 17% dos casos diagnosticados por ano. O tumor pode ocorrer em qualquer parte do órgão sexual masculino e o tipo de estadiamento empregado é controverso. A classificação de Broders é a mais utilizada. Estudos sugerem a relação entre o desenvolvimento do carcinoma de pênis com a infecção por HPV (Papiloma Vírus Humano). O método de avaliação dos linfonodos inguinais permanece controverso sendo difícil a diferenciação entre linfadenomegalia inflamatória reacional e metastática. O exame físico não é um preditor confiável do comprometimento linfonodal pois pacientes com linfonodos palpáveis podem não apresentar metástases. Há poucas publicações sobre os mecanismos moleculares envolvidos na gênese e progressão do CEP. Apesar de vários marcadores terem sido avaliados, atualmente a aplicação clínica destes é limitada. A maior parte dos marcadores estudados requer procedimentos invasivos para obtenção do tecido tumoral. Existe a necessidade de encontrar através de uma técnica pouco invasiva marcadores tumorais circulantes capazes de diferenciar portadores de CEP com e sem envolvimento metastático. Neste tipo de neoplasia, a descoberta de biomarcadores que avaliem o prognóstico é relevante, pois o exame físico não é um indicador confiável do comprometimento linfonodal e da sobrevida.Os objetivos foram 1) revisar e discutir a epidemiologia, a etiologia, os diversos tipos de abordagem cirúrgica e as controvérsias no tratamento cirúrgico do câncer de pênis 2) investigar através da plataforma ClinProt/ MALDI / TOF a presença de marcadores plasmáticos capazes de discriminar indivíduos saudáveis de pacientes afetados por carcinoma epidermóide de pênis (CEP) 3) avaliar a importância destes marcadores na evolução da doença. Foram coletados e analisados pela plataforma ClinProt / MALDI / TOF o plasma de 36 indivíduos saudáveis e 25 pacientes com CEP invasivo, submetidos a tratamento cirúrgico entre junho de 2010 e junho de 2011, nos serviços de urologia do Instituto Nacional de Câncer e do Hospital Mário Kröeff (Rio de Janeiro). Nossos resultados apontaram para um conjunto de dois peptídeos (A = m / z 1897,22 + -9 Da e B = m / z 2021,99 + -9 Da) que foram capazes de diferenciar pacientes com CEP de indivíduos controles. Esses peptídeos foram posteriormente identificados como fragmentos C3 e C4 A/B do sistema complemento. A validação cruzada, utilizando toda casuística apresentou 62,5% e 86,76% de sensibilidade e de especificidade, respectivamente, com uma alta sensibilidade (100%) e especificidade (97%) nos pacientes que morreram pela doença. Além disso, os pacientes com envolvimento ganglionar obtiveram uma sensibilidade e uma especificidade de 80 % e 97%, respectivamente. Ficou demonstrado que à medida que a doença progride mais subexpressos está o conjunto de peptídeos quando comparados com indivíduos saudáveis. Estes resultados podem ser úteis como ferramentas para a avaliação do prognóstico destes pacientes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A articulação temporomandibular (ATM) é uma articulação complexa com características e funções únicas. Certamente é uma das articulações mais utilizadas e seu uso inadequado e excessivo consequentemente promove inúmeros transtornos. Dentre as alterações de hipermobilidade articular, o deslocamento mandibular refere-se ao posicionamento, geralmente anterior, do côndilo mandibular sobre a eminência articular, com completa separação das superfícies articulares e consequente travamento. Quando os episódios se tornam frequentes, algum método de tratamento, seja conservador ou cirúrgico, deve ser utilizado, devido ao grande transtorno funcional e social gerados. A injeção de sangue autógeno na articulação temporomandibular é uma técnica minimamente invasiva, com escassos relatos na literatura e que foi recentemente reintroduzida. Onze pacientes diagnosticados com luxação recidivante da articulação da cabeça mandibular receberam injeções bilaterais de sangue autógeno no compartimento articular superior e região pericapsular. Em acompanhamento, que variou de 24 a 35 meses (média de 29,6 meses), 3 (27,3%) pacientes apresentaram recidivas. O mesmo protocolo de tratamento foi repetido para estes três casos, porém sem sucesso, sendo então encaminhados para procedimento cirúrgico de eminectomia. Dessa forma, dos 11 pacientes inicialmente tratados, 8 (72,7%) não apresentaram episódios de deslocamento mandibular recorrente após o procedimento proposto. Trata-se de um procedimento simples, rápido, pouco invasivo, de baixo custo e com mínima possibilidade de complicações, sendo uma alternativa de tratamento viável, antes de se indicar procedimentos cirúrgicos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.

PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.

RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.

CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.