967 resultados para Measuring instruments.
Resumo:
Measuring consumer satisfaction in the social services has become an important source of feedback for the improvement of service delivery. Consumer satisfaction has recently been incorporated into family preservation evaluation. This article reviews instruments used to measure consumer satisfaction in family preservation services and other related areas. Trends in current practice are examined and instrument dimensions are identified. Finally, some recommendations are made about the application of consumer satisfaction measurement in family preservation services.
Resumo:
Vitrectomy is a standard ophthalmic procedure to remove the vitreous body from the eye. The biomechanics of the vitreous affects its duration (by changing the removal rate) and the mechanical forces transmitted via the vitreous on the surrounding tissues during the procedure. Biomechanical characterization of the vitreous is essential for optimizing the design and control of instruments that operate within the vitreous for improved precision, safety, and efficacy. The measurements are carried out using a magnetic microprobe inserted into the vitreous, a method known as magnetic microrheology. The location of the probe is tracked by a microscope/camera while magnetic forces are exerted wirelessly by applied magnetic fields. In this work, in vitro artificial vitreous, ex vivo human vitreous and ex vivo porcine vitreous were characterized. In addition, in vivo rabbit measurements were performed using a suturelessly injected probe. Measurements indicate that viscoelasticity parameters of the ex vivo human vitreous are an order of magnitude different from those of the ex vivo porcine vitreous. The in vivo intra-operative measurements show typical viscoelastic behavior of the vitreous with a lower compliance than the ex vivo measurements. The results of the magnetic microrheology measurements were validated with those obtained by a standard atomic force microscopy (AFM) method and in vitro artificial vitreous. This method allows minimally-invasive characterization of localized mechanical properties of the vitreous in vitro, ex vivo, and in vivo. A better understanding of the characteristics of the vitreous can lead to improvements in treatments concerning vitreal manipulation such as vitrectomy.
Resumo:
The aim of the present study was to develop a pictorial presence scale using selfassessment- manikins (SAM). The instrument assesses presence sub-dimensions (selflocation and possible actions) as well as presence determinants (attention allocation, spatial situation model, higher cognitive involvement, and suspension of disbelief). To qualitatively validate the scale, think-aloud protocols and interviews (n = 12) were conducted. The results reveal that the SAM items are quickly filled out as well as easily, intuitively, and unambiguously understood. Furthermore, the instrument’s validity and sensitivity was quantitatively examined in a two-factorial design (n = 317). Factors were medium (written story, audio book, video, and computer game) and distraction (non-distraction vs. distraction). Factor analyses reveal that the SAM presence dimensions and determinants closely correspond to those of the MEC Spatial Presence Questionnaire, which was used as a comparison measure. The findings of the qualitative and quantitative validation procedures show that the Pictorial Presence SAM successfully assesses spatial presence. In contrast to the verbal questionnaire data (MEC), the significant distraction effect suggests that the new scale is even more sensitive. This points out that the scale can be a useful alternative to existing verbal presence selfreport measures.
Resumo:
Research has shown that disease-specific health related quality of life (HRQoL) instruments are more responsive than generic instruments to particular disease conditions. However, only a few studies have used disease-specific instruments to measure HRQoL in hemophilia. The goal of this project was to develop a disease-specific utility instrument that measures patient preferences for various hemophilia health states. The visual analog scale (VAS), a ranking method, and the standard gamble (SG), a choice-based method incorporating risk, were used to measure patient preferences. Study participants (n = 128) were recruited from the UT/Gulf States Hemophilia and Thrombophilia Center and stratified by age: 0–18 years and 19+. ^ Test retest reliability was demonstrated for both VAS and SG instruments: overall within-subject correlation coefficients were 0.91 and 0.79, respectively. Results showed statistically significant differences in responses between pediatric and adult participants when using the SG (p = .045). However, no significant differences were shown between these groups when using the VAS (p = .636). When responses to VAS and SG instruments were compared, statistically significant differences in both pediatric (p < .0001) and adult (p < .0001) groups were observed. Data from this study also demonstrated that persons with hemophilia with varying severity of disease, as well as those who were HIV infected, were able to evaluate a range of health states for hemophilia. This has important implications for the study of quality of life in hemophilia and the development of disease-specific HRQoL instruments. ^ The utility measures obtained from this study can be applied in economic evaluations that analyze the cost/utility of alternative hemophilia treatments. Results derived from the SG indicate that age can influence patients' preferences regarding their state of health. This may have implications for considering treatment options based on the mean age of the population under consideration. Although both instruments independently demonstrated reliability and validity, results indicate that the two measures may not be interchangeable. ^
Resumo:
One of the core objectives of urban planning practice is to provide spatial equity in terms of opportunities and use of public space and facilities. Accessibility is the element that serves this purpose as a concept linking the reciprocal relationship between transport and land use, thus shaping individual potential mobility to reach the desired destinations. Accessibility concepts are increasingly acknowledged as fundamental to understand the functioning of cities and urban regions. Indeed, by introducing them in planning practice, better solutions can be achieved in terms of spatial equity. The COST Action TU1002 "Accessibility instruments for planning practice" was specifically designed to address the gap between scientific research in measuring and modelling accessibility, and the current use of indicators of accessibility in urban planning practice. This paper shows the full process of introducing an easily understandable measure of accessibility to planning practitioners in Madrid, which is one of the case studies of the above-mentioned COST action. Changes in accessibility after the opening of a new metro line using contour measures were analyzed and then presented to a selection of urban planners and practitioners in Madrid as part of a workshop to evaluate the usefulness of this tool for planning practice. Isochrone maps were confirmed as an effective tool, as their utility can be supplemented by other indicators, and being GIS-based, it can be easily computed (when compared with transport models) and integrated with other datasets.
Resumo:
The optical power of a thick spherical lens and its Coddington shape factor are essential magnitudes that characterize its image quality. Here, we propose an experimental procedure and apparatus that allow accurate determination of those magnitudes for any spherical lens from geometrical measurements. The performance of the technique and the used instruments are simple since it only requires a microscope and an optical mouse. The propose overcomes the drawbacks of other devices that need of the refractive index or may damage the lens surfaces, like spherometers, and provides similar results to those from commercial lensmeters.
Investigation of the operating characteristics of the Iowa sediment concentration measuring system /
Resumo:
"May 1976."
Resumo:
"March 1977--Cover."
Resumo:
Aims. To validate the Swedish version of the Sheffield Care Environment Assessment Matrix (S-SCEAM). The instrument’s items measure environmental elements important for supporting the needs of older people, and conceptualized within eight domains. Methods. Item relevance was assessed by a group of experts and measured using content validity index (CVI). Test-retest and inter-rater reliability tests were performed. The domain structure was assessed by the inter-rater agreement of a second group of experts, and measured using Fleiss kappa. Results. All items attained a CVI above 0.78, the suggested criteria for excellent content validity. Test-retest reliability showed high stability (96% and 95% for two independent raters respectively), and inter-rater reliability demonstrated high levels of agreement (95% and 94% on two separate rating occasions). Kappa values were very good for test-retest (κ = 0.903 and 0.869) and inter-rater reliability (κ = 0.851 and 0.832). Domain structure was good, Fleiss’ kappa was 0.63 (range 0.45 to 0.75). Conclusion. The S-SCEAM of 210 items and eight domains showed good content validity and construct validity. The instrument is suggested for use in measuring of the quality of the physical environment in residential care facilities for older persons.
Resumo:
OBJECTIVE: To compare, in patients with cancer and in healthy subjects, measured resting energy expenditure (REE) from traditional indirect calorimetry to a new portable device (MedGem) and predicted REE. DESIGN: Cross-sectional clinical validation study. SETTING: Private radiation oncology centre, Brisbane, Australia. SUBJECTS: Cancer patients (n = 18) and healthy subjects (n = 17) aged 37-86 y, with body mass indices ranging from 18 to 42 kg/m(2). INTERVENTIONS: Oxygen consumption (VO(2)) and REE were measured by VMax229 (VM) and MedGem (MG) indirect calorimeters in random order after a 12-h fast and 30-min rest. REE was also calculated from the MG without adjustment for nitrogen excretion (MGN) and estimated from Harris-Benedict prediction equations. Data were analysed using the Bland and Altman approach, based on a clinically acceptable difference between methods of 5%. RESULTS: The mean bias (MGN-VM) was 10% and limits of agreement were -42 to 21% for cancer patients; mean bias -5% with limits of -45 to 35% for healthy subjects. Less than half of the cancer patients (n = 7, 46.7%) and only a third (n = 5, 33.3%) of healthy subjects had measured REE by MGN within clinically acceptable limits of VM. Predicted REE showed a mean bias (HB-VM) of -5% for cancer patients and 4% for healthy subjects, with limits of agreement of -30 to 20% and -27 to 34%, respectively. CONCLUSIONS: Limits of agreement for the MG and Harris Benedict equations compared to traditional indirect calorimetry were similar but wide, indicating poor clinical accuracy for determining the REE of individual cancer patients and healthy subjects.