957 resultados para Marx generator
Resumo:
Two case studies are presented in this paper to demonstrate the impact of different power system operation conditions on the power oscillation frequency modes in the Irish power system. A simplified 2 area equivalent of the Irish power system has been used in this paper, where area 1 represents the Republic of Ireland power system and area 2 represents the Northern Ireland power system.
The potential power oscillation frequency modes on the interconnector during different operation conditions have been analysed in this paper. The main objective of this paper is to analyse the influence of different operation conditions involving wind turbine generator (WTG) penetration on power oscillation frequency modes using phasor measurement unit (PMU) data.
Fast Fourier transform (FFT) analysis was performed to identify the frequency oscillation mode while correlation coefficient analysis was used to determine the source of the frequency oscillation. The results show that WTG, particularly fixed speed induction generation (FSIG), gives significant contribution to inter-area power oscillation frequency modes during high WTG operation.
Resumo:
In this paper, a new field-programmable gate array (FPGA) identification generator circuit is introduced based on physically unclonable function (PUF) technology. The new identification generator is able to convert flip-flop delay path variations to unique n-bit digital identifiers (IDs), while requiring only a single slice per ID bit by using 1-bit ID cells formed as hard-macros. An exemplary 128-bit identification generator is implemented on ten Xilinx Spartan-6 FPGA devices. Experimental results show an uniqueness of 48.52%, and reliability of 92.41% over a 25°C to 70°C temperature range and 10% fluctuation in supply voltage
Resumo:
Physically Unclonable Functions (PUFs), exploit inherent manufacturing variations and present a promising solution for hardware security. They can be used for key storage, authentication and ID generations. Low power cryptographic design is also very important for security applications. However, research to date on digital PUF designs, such as Arbiter PUFs and RO PUFs, is not very efficient. These PUF designs are difficult to implement on Field Programmable Gate Arrays (FPGAs) or consume many FPGA hardware resources. In previous work, a new and efficient PUF identification generator was presented for FPGA. The PUF identification generator is designed to fit in a single slice per response bit by using a 1-bit PUF identification generator cell formed as a hard-macro. In this work, we propose an ultra-compact PUF identification generator design. It is implemented on ten low-cost Xilinx Spartan-6 FPGA LX9 microboards. The resource utilization is only 2.23%, which, to the best of the authors' knowledge, is the most compact and robust FPGA-based PUF identification generator design reported to date. This PUF identification generator delivers a stable range of uniqueness of around 50% and good reliability between 85% and 100%.
Resumo:
- Fourieranalyse - Fouriersynthese - digitale Signalsynthese - mikrocomputergesteuerter Generator.
Resumo:
Enthält: Günter Buchholz: Einleitung - Die Krise ist die Kritik Stefan Voß: Kann die Hypothese der finanziellen Instabilität von Minsky die aktuelle Finanzkrise 2007/09 erklären? Alfred Müller: Kann die Wirtschafts- und Finanzkrise mit der Marxschen Theorie erklärt werden? Irina Jundt: Neue Finanzprodukte und Finanzmärkte
Resumo:
Marxian thinking following the TSSI (Temporal Single System Interpretation) of Marx is applied to refute the allegation of a tautology in the resource-based view of the firm--paired with providing an explanation of how and why resources create value--, where resources are synonymous with Marx's categories of constant and variable capital. Refuting the allegation naturally leads to the holy grail of resource-based thinking, i.e. the question of what, conceptually, constitutes a firm's competitive advantage within the industry context. The article achieves its objectives by tying the resource-based view into Marx's theory value.
Resumo:
In this paper, two wind turbines equipped with a permanent magnet synchronous generator (PMSG) and respectively with a two-level or a multilevel converter are simulated in order to access the malfunction transient performance. Three different drive train mass models, respectively, one, two and three mass models, are considered in order to model the bending flexibility of the blades. Moreover, a fractional-order control strategy is studied comparatively to a classical integer-order control strategy. Computer simulations are carried out, and conclusions about the total harmonic distortion (THD) of the electric current injected into the electric grid are in favor of the fractional-order control strategy.
Resumo:
Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.
Resumo:
The original objective of this work was to provide a simple generator w.hich would produce hydrogen torLfuel-cell feed and which could be operated under remote or northern conditions. A secondary objective was to maximize the yield of hydrogen and carbon monoxide from available feed-stocks. A search of the patent literature has indicated that the concept of a small Wulff-type generator is essentially sound and that hydrogen may be recovered from a wide variety of hydrocarbon feed-stocks. A simple experimental set-up has been devised, patterned after ~~t originally used by R. G. Wulff for producing acetylene. This provides a supply of feed-stock, with or Without a carrier gas, which may be passed directly through a heated tube, which may contain a catalyst. A suitable procedure has been devised for analysi~ effluent gases for hydrogen, oxygen, nitrogen, methane and carbon monoxide by gas chromatography with the column packed with .Molecular .:>ieve .5 4. Athanol with air a.s carrier gas and at the same time as oxidant o was thermolyzed at temperatures in the ra~e 700-1100 C, with or Wi~lout catalyst. Methanol with or without nitrogen as a carrier gas was also cracked with • the same type of reactor refractory tube, but the temperature range was lower t down to ,300 " C when a catalyst was used. The problems of converting methane to hydrogen and carbon monoxide effiCiently, using air and/or water as oxidants were also studied.
Resumo:
Self-dual doubly even linear binary error-correcting codes, often referred to as Type II codes, are codes closely related to many combinatorial structures such as 5-designs. Extremal codes are codes that have the largest possible minimum distance for a given length and dimension. The existence of an extremal (72,36,16) Type II code is still open. Previous results show that the automorphism group of a putative code C with the aforementioned properties has order 5 or dividing 24. In this work, we present a method and the results of an exhaustive search showing that such a code C cannot admit an automorphism group Z6. In addition, we present so far unpublished construction of the extended Golay code by P. Becker. We generalize the notion and provide example of another Type II code that can be obtained in this fashion. Consequently, we relate Becker's construction to the construction of binary Type II codes from codes over GF(2^r) via the Gray map.