878 resultados para Marcha gait
Resumo:
Managing gait disturbances in people with Parkinson’s disease is a pressing challenge, as symptoms can contribute to injury and morbidity through an increased risk of falls. While drug-based interventions have limited efficacy in alleviating gait impairments, certain non-pharmacological methods, such as cueing, can also induce transient improvements to gait. The approach adopted here is to use computationally-generated sounds to help guide and improve walking actions. The first method described uses recordings of force data taken from the steps of a healthy adult which in turn were used to synthesize realistic gravel-footstep sounds that represented different spatio-temporal parameters of gait, such as step duration and step length. The second method described involves a novel method of sonifying, in real time, the swing phase of gait using real-time motion-capture data to control a sound synthesis engine. Both approaches explore how simple but rich auditory representations of action based events can be used by people with Parkinson’s to guide and improve the quality of their walking, reducing the risk of falls and injury. Studies with Parkinson’s disease patients are reported which show positive results for both techniques in reducing step length variability. Potential future directions for how these sound approaches can be used to manage gait disturbances in Parkinson’s are also discussed.
Resumo:
Objectives: A common behavioural symptom of Parkinson’s disease (PD) is reduced step length (SL). Whilst sensory cueing strategies can be effective in increasing SL and reducing gait variability, current cueing strategies conveying spatial or temporal information are generally confined to the use of either visual or auditory cue modalities, respectively. We describe a novel cueing strategy using ecologically-valid ‘action-related’ sounds (footsteps on gravel) that convey both spatial and temporal parameters of a specific action within a single cue.
Methods: The current study used a real-time imitation task to examine whether PD affects the ability to re-enact changes in spatial characteristics of stepping actions, based solely on auditory information. In a second experimental session, these procedures were repeated using synthesized sounds derived from recordings of the kinetic interactions between the foot and walking surface. A third experimental session examined whether adaptations observed when participants walked to action-sounds were preserved when participants imagined either real recorded or synthesized sounds.
Results: Whilst healthy control participants were able to re-enact significant changes in SL in all cue conditions, these adaptations, in conjunction with reduced variability of SL were only observed in the PD group when walking to, or imagining the recorded sounds.
Conclusions: The findings show that while recordings of stepping sounds convey action information to allow PD patients to re-enact and imagine spatial characteristics of gait, synthesis of sounds purely from gait kinetics is insufficient to evoke similar changes in behaviour, perhaps indicating that PD patients have a higher threshold to cue sensorimotor resonant responses.
Resumo:
Gait period estimation is an important step in the gait recognition framework. In this paper, we propose a new gait cycle detection method based on the angles of extreme points of both legs. In addition to that, to further improve the estimation of the gait period, the proposed algorithm divides the gait sequence into sections before identifying the maximum values. The proposed algorithm is scale invariant and less dependent on the silhouette shape. The performance of the proposed method was evaluated using the OU-ISIR speed variation gait database. The experimental results show that the proposed method achieved 90.2% gait recognition accuracy and outperforms previous methods found in the literature with the second best only achieved 67.65% accuracy.
Resumo:
A nonsense mutation in DMRT3 ('Gait keeper' mutation) has a predominant effect on gaiting ability in horses, being permissive for the ability to perform lateral gaits and having a favourable effect on speed capacity in trot. The DMRT3 mutant allele (A) has been found in high frequency in gaited breeds and breeds bred for harness racing, while other horse breeds were homozygous for the wild-type allele (C). The aim of this study was to evaluate further the effect of the DMRT3 nonsense mutation on the gait quality and speed capacity in the multigaited Icelandic horse and demonstrate how the frequencies of the A- and C- alleles have changed in the Icelandic horse population in recent decades. It was confirmed that homozygosity for the DMRT3 nonsense mutation relates to the ability to pace. It further had a favourable effect on scores in breeding field tests for the lateral gait tölt, demonstrated by better beat quality, speed capacity and suppleness. Horses with the CA genotype had on the other hand significantly higher scores for walk, trot, canter and gallop, and they performed better beat and suspension in trot and gallop. These results indicate that the AA genotype reinforces the coordination of ipsilateral legs, with the subsequent negative effect on the synchronized movement of diagonal legs compared with the CA genotype. The frequency of the A-allele has increased in recent decades with a corresponding decrease in the frequency of the C-allele. The estimated frequency of the A-allele in the Icelandic horse population in 2012 was 0.94. Selective breeding for lateral gaits in the Icelandic horse population has apparently altered the frequency of DMRT3 genotypes with a predicted loss of the C-allele in relatively few years. The results have practical implications for breeding and training of Icelandic horses and other gaited horse breeds.
Resumo:
Studies have been carried out to recognize individuals from a frontal view using their gait patterns. In previous work, gait sequences were captured using either single or stereo RGB camera systems or the Kinect 1.0 camera system. In this research, we used a new frontal view gait recognition method using a laser based Time of Flight (ToF) camera. In addition to the new gait data set, other contributions include enhancement of the silhouette segmentation, gait cycle estimation and gait image representations. We propose four new gait image representations namely Gait Depth Energy Image (GDE), Partial GDE (PGDE), Discrete Cosine Transform GDE (DGDE) and Partial DGDE (PDGDE). The experimental results show that all the proposed gait image representations produce better accuracy than the previous methods. In addition, we have also developed Fusion GDEs (FGDEs) which achieve better overall accuracy and outperform the previous methods.
Resumo:
Gait disturbances are a common feature of Parkinson’s disease, one of the most severe being freezing of gait. Sensory cueing is a common method used to facilitate stepping in people with Parkinson’s. Recent work has shown that, compared to walking to a metronome, Parkinson’s patients without freezing of gait (nFOG) showed reduced gait variability when imitating recorded sounds of footsteps made on gravel. However, it is not known if these benefits are realised through the continuity of the acoustic information or the action-relevance. Furthermore, no study has examined if these benefits extend to PD with freezing of gait. We prepared four different auditory cues (varying in action-relevance and acoustic continuity) and asked 19 Parkinson’s patients (10 nFOG, 9 with freezing of gait (FOG)) to step in place to each cue. Results showed a superiority of action-relevant cues (regardless of cue-continuity) for inducing reductions in Step coefficient of variation (CV). Acoustic continuity was associated with a significant reduction in Swing CV. Neither cue-continuity nor action-relevance was independently sufficient to increase the time spent stepping before freezing. However, combining both attributes in the same cue did yield significant improvements. This study demonstrates the potential of using action-sounds as sensory cues for Parkinson’s patients with freezing of gait. We suggest that the improvements shown might be considered audio-motor ‘priming’ (i.e., listening to the sounds of footsteps will engage sensorimotor circuitry relevant to the production of that same action, thus effectively bypassing the defective basal ganglia).
Resumo:
The knee adduction moment (KAM) during gait has been proposed as an indirect measure of dynamic knee joint loading and has been reported to be higher in obese children [1, 2]. The KAM is primarily calculated from the resultant ground reaction force (GRF) and the lever arm length, both of which can be manipulated through weight-loss or medical interventions [1]. However, there is little data on the relationships between the mechanical, anthropometric and gait contributors to the KAM during paediatric gait. The objectives of the study were to examine the associations with the first (1st) and second (2nd) peak KAM (pKAM) and: (1) centre of pressure (CoP), KAM lever arm length, vertical and mediolateral ground reaction forces (GRF) and, (2) fat mass, height, step width, foot rotation, knee rotation and walking velocity.
Resumo:
Introdução: As canadianas são utilizadas em múltiplos quadros clínicos em que existe compromisso da marcha. No entanto, é fulcral considerar as diferentes exigências metabólicas associadas a cada auxiliar e tipo de marcha. Objetivo: Avaliar o dispêndio energético (DE) na marcha normal (MN), com uma canadiana e com duas canadianas a 3 pontos e a 3 pontos modificada em jovens e idosos. Metodologia: Estudo analítico transversal, composto por 21 indivíduos. As variáveis analisadas foram o volume de oxigénio inspirado (VO2), volume de dióxido de carbono expirado (VCO2) e quociente respiratório (QR), obtidas através do sistema portátil (Cosmed K4b2, Cosmed, Roma, Itália). Resultados: Os participantes tinham idades entre 18 e 75 anos (11 jovens e 10 idosos). Os idosos apresentaram valores significativamente mais elevados que os jovens no DE na marcha com uma canadiana a 3 pontos (p=0,009) e com duas canadianas a 3 pontos (p=0,008), enquanto nas restantes marchas não houve diferenças estatisticamente significativas (p>0,05). A MN e a marcha com duas canadianas a 3 pontos foram os tipos de marcha com maior DE nos jovens, e nos idosos. Nos jovens, a MN apresentou 19% a 45% maior DE do que as restantes marchas, enquanto nos idosos verificou-se que todas as marchas (à exceção de uma canadiana a 3 pontos modificada) apresentaram um maior DE (entre 7 e 16%) comparativamente à MN. Conclusão: Os idosos apresentaram valores significativamente mais elevados de DE que os jovens nas marchas uma e duas canadianas a 3 pontos. Na MN e na marcha uma canadiana a 3 pontos modificada existe uma tendência para os jovens apresentarem valores de DE superior aos idosos. A medição do DE fornece uma indicação precisa da eficiência da marcha, sendo útil como suporte para a decisão clínica e para uma adequada reabilitação.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
O presente estudo tem como objetivo comparar experimentalmente duas crianças praticantes de Hóquei em Patins, uma normal e uma com a patologia dos joelhos valgos, avaliando qualitativamente as diferenças posturais, estáticas e dinâmicas, decorrentes da utilização dos patins específicos desta modalidade, através do sistema de análise da Força de Reação do Solo (FRS), de Eletromiografia (EMG), de captura de movimento, e de modelação e simulação. Para atingir o objetivo definiu-se um protocolo de ensaios com as seguintes tarefas: repouso com e sem patins, marcha, corrida, deslizar com os dois pés apoiados e deslizar com o pé esquerdo levantado. No repouso avaliou-se a variação do ponto de aplicação da FRS da criança normal e patológica, com e sem patins. Ainda na tarefa de repouso avaliou-se também as componentes médio-lateral, antero-posterior individualmente e a componente vertical da FRS, juntamente com a atividade muscular dos músculos Gastrocnémio Medial (GM), Recto Femoral (RF), Vasto Medial (VM), Vasto Lateral (VL), Bicípete Femoral (BF), Semitendinoso (ST), Tensor da Fascia Lata (TFL), Gastrocnémio Lateral (GL), de forma a comparar os valores de intensidade de FRS e da atividade muscular dos diferentes instantes de tempo desta tarefa. Para as restantes tarefas apenas se avaliou individualmente as componentes médio-lateral e antero-posterior da FRS e a componente vertical da FRS juntamente com a atividade muscular dos referidos músculos, salientando as diferenças evidentes entre as curvas da criança normal e as curvas da criança patológica durante os diferentes instantes do movimento. Todas as tarefas referidas, exceto a tarefa de repouso com patins, foram ainda simuladas recorrendo a modelos músculo-esqueléticos. A partir destas simulações do movimento obtiveram-se os ângulos articulares e efetuou-se a respetiva análise. No final dos resultados obtidos apresentou-se uma tabela de resumo com o cálculo dos coeficientes de variação de cada grandeza, exceto nos gráficos da posição no espaço da FRS, onde se constatou que existe uma grande variabilidade inter-individuo em cada tarefa. A análise dos resultados de cada tarefa permite concluir que a utilização de patins pode trazer uma maior ativação muscular para a criança patológica, embora se verifique instabilidade articular. Apesar dessa instabilidade pode-se inferir que, uma maior ativação muscular decorrente da utilização de patins, tal como acontece na prática do hóquei em patins, pode trazer uma melhoria, a longo prazo, na estabilidade da articulação do joelho e na sustentação corporal, proporcionada pelo fortalecimento muscular.
Resumo:
This study compared the ground reaction forces (GRF) and plantar pressures between unloaded and occasional loaded gait. The GRF and plantar pressures of 60 participants were recorded during unloaded gait and occasional loaded gait (wearing a backpack that raised their body mass index to 30); this load criterion was adopted because is considered potentially harmful in permanent loaded gait (obese people). The results indicate an overall increase (absolute values) of GRF and plantar pressures during occasional loaded gait (p < 0.05); also, higher normalized (by total weight) values in the medial midfoot and toes, and lower values in the lateral rearfoot region were observed. During loaded gait the magnitude of the vertical GRF (impact and thrust maximum) decreased and the shear forces increased more than did the proportion of the load (normalized values). These data suggest a different pattern of GRF and plantar pressure distribution during occasional loaded compared to unloaded gait.
Resumo:
Introdução – O efeito de êmbolo é um dos principais problemas relacionados com a eficácia de uma prótese. Uma diminuição do mesmo pode levar a uma marcha mais natural através do aumento da propriocetividade. Objetivos – Verificar se existe diferença de valores do efeito de êmbolo entre vários sistemas de suspensão para próteses transtibiais com a utilização de Liners e testar a aplicação de testes de imagiologia na análise da melhor solução protésica para um determinado indivíduo. Metodologia – Foi obtida uma radiografia da prótese em carga na posição ortostática, mantendo o peso do indivíduo igualmente distribuído pelos dois pés. Seguidamente foi realizada outra radiografia no plano sagital com o joelho com 30° de flexão, com a prótese suspensa e um peso de 5kg aplicado na extremidade distal da mesma durante 30 seg. Através destes dois exames efetuaram-se as medições do êmbolo para cada tipo de sistema de suspensão. Resultados – Dos quatro sistemas estudados apenas três apresentam valores de êmbolo, visto que um dos sistemas não criou suspensão suficiente para suportar o peso colocado na extremidade distal da prótese. Através das medições realizadas nos exames imagiológicos dos três sistemas pudemos encontrar variações de efeito de êmbolo que vão dos 47,91mm aos 72,55mm. Conclusão – Através da realização do estudo imagiológico verificaram-se diferenças a nível do efeito de êmbolo nos vários sistemas de suspensão, provando que esta é uma ferramenta viável na avaliação do mesmo. Também através da análise dos resultados ficou notório que o sistema de suspensão Vacuum Assisted Suspention System (VASS) é o que apresenta menos êmbolo.