984 resultados para Lung volume measurement


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Computer-Aided-Design (CAD) and Computer-Aided-Manufacture (CAM) has been developed to fabricate fixed dental restorations accurately, faster and improve cost effectiveness of manufacture when compared to the conventional method. Two main methods exist in dental CAD/CAM technology: the subtractive and additive methods. While fitting accuracy of both methods has been explored, no study yet has compared the fabricated restoration (CAM output) to its CAD in terms of accuracy. The aim of this present study was to compare the output of various dental CAM routes to a sole initial CAD and establish the accuracy of fabrication. The internal fit of the various CAM routes were also investigated. The null hypotheses tested were: 1) no significant differences observed between the CAM output to the CAD and 2) no significant differences observed between the various CAM routes. Methods: An aluminium master model of a standard premolar preparation was scanned with a contact dental scanner (Incise, Renishaw, UK). A single CAD was created on the scanned master model (InciseCAD software, V2.5.0.140, UK). Twenty copings were then fabricated by sending the single CAD to a multitude of CAM routes. The copings were grouped (n=5) as: Laser sintered CoCrMo (LS), 5-axis milled CoCrMo (MCoCrMo), 3-axis milled zirconia (ZAx3) and 4-axis milled zirconia (ZAx4). All copings were micro-CT scanned (Phoenix X-Ray, Nanotom-S, Germany, power: 155kV, current: 60µA, 3600 projections) to produce 3-Dimensional (3D) models. A novel methodology was created to superimpose the micro-CT scans with the CAD (GOM Inspect software, V7.5SR2, Germany) to indicate inaccuracies in manufacturing. The accuracy in terms of coping volume was explored. The distances from the surfaces of the micro-CT 3D models to the surfaces of the CAD model (CAD Deviation) were investigated after creating surface colour deviation maps. Localised digital sections of the deviations (Occlusal, Axial and Cervical) and selected focussed areas were then quantitatively measured using software (GOM Inspect software, Germany). A novel methodology was also explored to digitally align (Rhino software, V5, USA) the micro-CT scans with the master model to investigate internal fit. Fifty digital cross sections of the aligned scans were created. Point-to-point distances were measured at 5 levels at each cross section. The five levels were: Vertical Marginal Fit (VF), Absolute Marginal Fit (AM), Axio-margin Fit (AMF), Axial Fit (AF) and Occlusal Fit (OF). Results: The results of the volume measurement were summarised as: VM-CoCrMo (62.8mm3 ) > VZax3 (59.4mm3 ) > VCAD (57mm3 ) > VZax4 (56.1mm3 ) > VLS (52.5mm3 ) and were all significantly different (p presented as areas with different colour. No significant differences were observed at the internal aspect of the cervical aspect between all groups of copings. Significant differences (p< M-CoCrMo Internal Occlusal, Internal Axial and External Axial 2 ZAx3 > ZAx4 External Occlusal, External Cervical 3 ZAx3 < ZAx4 Internal Occlusal 4 M-CoCrMo > ZAx4 Internal Occlusal and Internal Axial The mean values of AMF and AF were significantly (p M-CoCrMo and CAD > ZAx4. Only VF of M-CoCrMo was comparable with the CAD Internal Fit. All VF and AM values were within the clinically acceptable fit (120µm). Conclusion: The investigated CAM methods reproduced the CAD accurately at the internal cervical aspect of the copings. However, localised deviations at axial and occlusal aspects of the copings may suggest the need for modifications in these areas prior to fitting and veneering with porcelain. The CAM groups evaluated also showed different levels of Internal Fit thus rejecting the null hypotheses. The novel non-destructive methodologies for CAD/CAM accuracy and internal fit testing presented in this thesis may be a useful evaluation tool for similar applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed at determining the incidence and pattern of pneumonia, in slaughtered goats in Kumasi abattoir, Ghana. One thousand three hundred and fifty lungs of goats; (1,012 Sahelian and 338 West Africa Dwarf goats (WAD) lungs) of different ages (less than a year to above 4 years) were used in this study. The frequency of occurrence of pneumonia, the degree of consolidation as a percentage of the total lung volume and histological assessment were determined by standard techniques. Fifty five (55) lungs (39 Sahelian, 16 WAD goats) were pneumonic (4.07% prevalence). The right lungs had a significant higher average lung consolidation percentage (19.11) while the right cranial lobes were more affected (9.37). WAD goats of 1-2 years are mostly affected with an average percentage consolidation of 11.73% while Sahelian goats above 4 years of age were the most affected with 32.59% consolidation. Does of both breeds were more while Sahelian goats had higher consolidation than other breeds. Histological examination revealed the presence of giant cell, fibrinous and suppurative bronchointerstitial pneumonia suggesting complicated viral pneumonia which was observed to be the most important caprine pneumonia in slaughtered goats in Ghana. Transportation and pregnancy stress were the major contributory factor to the pneumonia observed hence effective ante-mortem examinations will help to minimize the slaughter of pregnant does and transportation stress in Ghana.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction : Les nourrissons, vu la grande compliance de leur cage thoracique, doivent maintenir activement leur volume pulmonaire de fin d’expiration (VPFE). Ceci se fait par interruption précoce de l’expiration, et par le freinage expiratoire au niveau laryngé et par la persistance de la contraction des muscles inspiratoires. Chez les nourrissons ventilés mécaniquement, notre équipe a montré que le diaphragme est activé jusqu’à la fin de l’expiration (activité tonique). Il n’est pas clair si cette activité tonique diaphragmatique compense pour l’absence de freinage laryngé liée à l’intubation endotrachéale. Objectif : Notre objectif est de déterminer si l’activité tonique diaphragmatique persiste après l’extubation chez les nourrissons et si elle peut être observée chez les enfants plus âgés. Méthode : Ceci est une étude observationnelle longitudinale prospective de patients âgés de 1 semaine à 18 ans admis aux soins intensifs pédiatriques (SIP), ventilés mécaniquement pour >24 heures et avec consentement parental. L’activité électrique du diaphragme (AEdi) a été enregistrée à l’aide d’une sonde nasogastrique spécifique à 4 moments durant le séjour aux SIP : en phase aigüe, pré et post-extubation et au congé. L’AEdi a été analysée de façon semi-automatique. L’AEdi tonique a été définie comme l’AEdi durant le dernier quartile de l’expiration. Résultats : 55 patients avec un âge médian de 10 mois (écart interquartile: 1-48) ont été étudiés. Chez les nourrissons (<1an, n=28), l’AEdi tonique en pourcentage de l’activité inspiratoire était de 48% (30-56) en phase aigüe, 38% (25-44) pré-extubation, 28% (17-42) post-extubation et 33% (22-43) au congé des SIP (p<0.05, ANOVA, avec différence significative entre enregistrements 1 et 3-4). Aucun changement significatif n’a été observé pré et post-extubation. L’AEdi tonique chez les patients plus âgés (>1an, n=27) était négligeable en phases de respiration normale (0.6mcv). Par contre, une AEdi tonique significative (>1mcv et >10%) a été observée à au moins un moment durant le séjour de 10 (37%) patients. La bronchiolite est le seul facteur indépendant associé à l’activité tonique diaphragmatique. Conclusion : Chez les nourrissons, l’AEdi tonique persiste après l’extubation et elle peut être réactivée dans certaines situations pathologiques chez les enfants plus âgés. Elle semble être un indicateur de l’effort du patient pour maintenir son VPFE. D’autres études devraient être menées afin de déterminer si la surveillance de l’AEdi tonique pourrait faciliter la détection de situations de ventilation inappropriée.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction : Les nourrissons, vu la grande compliance de leur cage thoracique, doivent maintenir activement leur volume pulmonaire de fin d’expiration (VPFE). Ceci se fait par interruption précoce de l’expiration, et par le freinage expiratoire au niveau laryngé et par la persistance de la contraction des muscles inspiratoires. Chez les nourrissons ventilés mécaniquement, notre équipe a montré que le diaphragme est activé jusqu’à la fin de l’expiration (activité tonique). Il n’est pas clair si cette activité tonique diaphragmatique compense pour l’absence de freinage laryngé liée à l’intubation endotrachéale. Objectif : Notre objectif est de déterminer si l’activité tonique diaphragmatique persiste après l’extubation chez les nourrissons et si elle peut être observée chez les enfants plus âgés. Méthode : Ceci est une étude observationnelle longitudinale prospective de patients âgés de 1 semaine à 18 ans admis aux soins intensifs pédiatriques (SIP), ventilés mécaniquement pour >24 heures et avec consentement parental. L’activité électrique du diaphragme (AEdi) a été enregistrée à l’aide d’une sonde nasogastrique spécifique à 4 moments durant le séjour aux SIP : en phase aigüe, pré et post-extubation et au congé. L’AEdi a été analysée de façon semi-automatique. L’AEdi tonique a été définie comme l’AEdi durant le dernier quartile de l’expiration. Résultats : 55 patients avec un âge médian de 10 mois (écart interquartile: 1-48) ont été étudiés. Chez les nourrissons (<1an, n=28), l’AEdi tonique en pourcentage de l’activité inspiratoire était de 48% (30-56) en phase aigüe, 38% (25-44) pré-extubation, 28% (17-42) post-extubation et 33% (22-43) au congé des SIP (p<0.05, ANOVA, avec différence significative entre enregistrements 1 et 3-4). Aucun changement significatif n’a été observé pré et post-extubation. L’AEdi tonique chez les patients plus âgés (>1an, n=27) était négligeable en phases de respiration normale (0.6mcv). Par contre, une AEdi tonique significative (>1mcv et >10%) a été observée à au moins un moment durant le séjour de 10 (37%) patients. La bronchiolite est le seul facteur indépendant associé à l’activité tonique diaphragmatique. Conclusion : Chez les nourrissons, l’AEdi tonique persiste après l’extubation et elle peut être réactivée dans certaines situations pathologiques chez les enfants plus âgés. Elle semble être un indicateur de l’effort du patient pour maintenir son VPFE. D’autres études devraient être menées afin de déterminer si la surveillance de l’AEdi tonique pourrait faciliter la détection de situations de ventilation inappropriée.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Introduction: Standard Uptake Value (SUV) is a measurement of the uptake in a tumour normalized on the basis of a distribution volume and is used to quantify 18F-Fluorodeoxiglucose (FDG) uptake in tumors, such as primary lung tumor. Several sources of error can affect its accuracy. Normalization can be based on body weight, body surface area (BSA) and lean body mass (LBM). The aim of this study is to compare the influence of 3 normalization volumes in the calculation of SUV: body weight (SUVW), BSA (SUVBSA) and LBM (SUVLBM), with and without glucose correction, in patients with known primary lung tumor. The correlation between SUV and weight, height, blood glucose level, injected activity and time between injection and image acquisition is evaluated. Methods: Sample included 30 subjects (8 female and 22 male) with primary lung tumor, with clinical indication for 18F-FDG Positron Emission Tomography (PET). Images were acquired on a Siemens Biography according to the department’s protocol. Maximum pixel SUVW was obtained for abnormal uptake focus through semiautomatic VOI with Quantification 3D isocontour (threshold 2.5). The concentration of radioactivity (kBq/ml) was obtained from SUVW, SUVBSA, SUVLBM and the glucose corrected SUV were mathematically obtained. Results: Statistically significant differences between SUVW, SUVBSA and SUVLBM and between SUVWgluc, SUVBSAgluc and SUVLBMgluc were observed (p=0.000<0.05). The blood glucose level showed significant positive correlations with SUVW (r=0.371; p=0.043) and SUVLBM (r=0.389; p=0.034). SUVBSA showed independence of variations with the blood glucose level. Conclusion: The measurement of a radiopharmaceutical tumor uptake normalized on the basis of different distribution volumes is still variable. Further investigation on this subject is recommended.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Background: Tumor volume has been shown to be a prognostic factor for the response of some tumors to radiotherapy. TNM stage has prognostic value for patients treated surgically for non-small cell lung cancer (NSCLC), but its value is less clear for patients treated by nonsurgical means. This may be because tumor size is not a consistent determinant of T stage or stage group. As part of the preliminary analyses for the Trans-Tasman Radiation Oncology Group 99-05 study, the authors performed this analysis to determine to what extent stage reflects tumor volume. Methods: In this prospective multicenter observational study, patients had to have histologically proven NSCLC, no evidence of disease beyond the primary site or thoracic lymph nodes, and been planned for radical radiotherapy with or without chemotherapy. Tumor volume measurements were based on computed tomography-based treatment planning images. Results: Four hundred four patients were available for analysis. There was a strong correlation between (log) maximum tumor diameter and (log) tumor volume (r = 0.93, p < 0.001). Although there was a highly significant trend of increasing volume with increasing T stage and stage group, when tumors were categorized into four groups according to increasing volume, there was only 55% concordance with T stage and 67% concordance with stage group. Conclusions: There is limited correlation between tumor size and disease stage in patients with NSCLC. This justifies documentation and investigation of size as a potential prognostic factor independent of stage. Maximum tumor diameter may be an adequate substitute for volume as a measurement of size.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lateral ventricular volumes based on segmented brain MR images can be significantly underestimated if partial volume effects are not considered. This is because a group of voxels in the neighborhood of lateral ventricles is often mis-classified as gray matter voxels due to partial volume effects. This group of voxels is actually a mixture of ventricular cerebro-spinal fluid and the white matter and therefore, a portion of it should be included as part of the lateral ventricular structure. In this note, we describe an automated method for the measurement of lateral ventricular volumes on segmented brain MR images. Image segmentation was carried in combination of intensity correction and thresholding. The method is featured with a procedure for addressing mis-classified voxels in the surrounding of lateral ventricles. A detailed analysis showed that lateral ventricular volumes could be underestimated by 10 to 30% depending upon the size of the lateral ventricular structure, if mis-classified voxels were not included. Validation of the method was done through comparison with the averaged manually traced volumes. Finally, the merit of the method is demonstrated in the evaluation of the rate of lateral ventricular enlargement. (C) 2001 Elsevier Science Inc. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To compare pressure–volume (P–V) curves obtained with the Galileo ventilator with those obtained with the CPAP method in patients with ALI or ARDS receiving mechanical ventilation. P–V curves were fitted to a sigmoidal equation with a mean R2 of 0.994 ± 0.003. Lower (LIP) and upper inflection (UIP), and deflation maximum curvature (PMC) points calculated from the fitted variables showed a good correlation between methods with high intraclass correlation coefficients. Bias and limits of agreement for LIP, UIP and PMC obtained with the two methods in the same patient were clinically acceptable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACT. A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is renewed interest in the immune regulatory role of the spleen in oncology. To date, very few studies have examined macroscopic variations of splenic volume in the setting of cancer, prior to or during therapy, especially in humans. Changes in splenic volume may be associated with changes in splenic function. The purpose of this study was to investigate variations in spleen volume in NSCLC patients during chemo-radiotherapy. Sixty patients with stage I-IIIB NSCLC underwent radiotherapy (60Gy/30 fractions) for six weeks with concomitant carboplatin/paclitaxel (Ca/P; n = 32) or cisplatin/etoposide (Ci/E; n = 28). A baseline PET/CT scan was performed within 2 weeks prior to treatment and during Weeks 2 and 4 of chemo-radiotherapy. Spleen volume was measured by contouring all CT slices. Significant macroscopic changes in splenic volume occurred early after the commencement of treatment. A significant decrease in spleen volume was observed for 66% of Ca/P and 79% of Ci/E patients between baseline and Week 2. Spleen volume was decreased by 14.2% for Ca/P (p<0.001) and 19.3% for Ci/E (p<0.001) patients. By Week 4, spleen volume was still significantly decreased for Ca/P patients compared to baseline, while for Ci/E patients, spleen volume returned to above baseline levels. This is the first report demonstrating macroscopic changes in the spleen in NSCLC patients undergoing radical chemo-radiotherapy that can be visualized by non-invasive imaging.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pulmonary dysfunction represents the most important cause of death in patients with paracoccidioidomycosis (PBM). In order to investigate the functional changes of the lungs in the early stages of PBM, a model of benign disease was developed by intratracheal challenge of 12-week old isogenic Wistar rats with 1 x 106 yeast forms of Paracoccidioides brasiliensis. Animals were studied 30 and 60 days after infection, when fully developed granulomas were demonstrable in the lungs. Measurements of airway resistance, lung elastance and tissue hysteresis were made during sinusoidal deformations (100 breaths/min, tidal volume = 2 ml) with direct measurement of alveolar pressure using the alveolar capsule technique. Infection caused a significant increase in hysteresis (infected: 1.69, N = 13; control: 1.13, N = 12, P = 0.024, ANOVA), with no alterations in airway resistance or lung elastance. Histopathological analysis revealed the presence of fully developed granulomas located in the axial compartment of the lung interstitial space. These results suggest that alterations of tissue mechanics represent an early event in experimental PBM

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mechanical ventilation with high tidal volumes (V T) has been shown to induce lung injury. We examined the hypothesis that this procedure induces lung injury with inflammatory features. Anesthetized male Wistar rats were randomized into three groups: group 1 (N = 12): V T = 7 ml/kg, respiratory rate (RR) = 50 breaths/min; group 2 (N = 10): V T = 21 ml/kg, RR = 16 breaths/min; group 3 (N = 11): V T = 42 ml/kg, RR = 8 breaths/min. The animals were ventilated with fraction of inspired oxygen of 1 and positive end-expiratory pressure of 2 cmH2O. After 4 h of ventilation, group 3, compared to groups 1 and 2, had lower PaO2 [280 (range 73-458) vs 517 (range 307-596), and 547 mmHg (range 330-662), respectively, P<0.05], higher wet lung weight [3.62 ± 0.91 vs 1.69 ± 0.48 and 1.44 ± 0.20 g, respectively, P<0.05], and higher wet lung weight/dry lung weight ratio [18.14 (range 11.55-26.31) vs 7.80 (range 4.79-12.18), and 6.34 (range 5.92-7.04), respectively, P<0.05]. Total cell and neutrophil counts were higher in group 3 compared to groups 1 and 2 (P<0.05), as were baseline TNF-alpha concentrations [134 (range <10-386) vs 16 (range <10-24), and 17 pg/ml (range <10-23), respectively, P<0.05]. Serum TNF-alpha concentrations reached a higher level in group 3, but without statistical significance. These results suggest that mechanical ventilation with high V T induces lung injury with inflammatory characteristics. This ventilatory strategy can affect the release of TNF-alpha in the lungs and can reach the systemic circulation, a finding that may have relevance for the development of a systemic inflammatory response.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for measuring the buccal bone volume around dental implants. Materials and methods: Three to six implants were inserted into the anterior maxilla of eight skulls, depending on the availability of bone, and after this, the CBCT was performed. By means of CBCT image, measurements of the bone wall at three points of the implant were obtained, analyzed and compared with those obtained in the plaster skull casting. Results: The results showed that for the three points of the implants, no statistically significant difference in the measurements was obtained from the plaster model and CBCT images. Conclusions: CBCT can be a useful tool for assessing buccal bone volume along the implant. To cite this article:?Shiratori LN, Marotti J, Yamanouchi J, Chilvarquer I, Contin I, Tortamano-Neto P. Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography.?Clin. Oral Impl. Res. 23, 2012; 797804.?doi: 10.1111/j.1600-0501.2011.02207.x