904 resultados para Laparoscopy surgery
Resumo:
Background Recent advances in laparoscopic techniques have resulted in growing indications for laparoscopic hepatectomy. However, this procedure has not been widely developed, and anatomic segmental liver resection is not Currently performed due to difficulty controlling the segmental Glissonian pedicles laparoscopically. This study aimed to report a novel technique for laparoscopic anatomic resection of left liver segments using the intrahepatic Glissonian approach based on small incisions according to anatomic landmarks such as Arantius` and round ligaments. Methods Nine consecutive patients underwent laparoscopic liver resection using the intrahepatic Glissonian technique from April 2007 to June 2008. Five patients underwent laparoscopic bisegmentectomy 2-3, one laparoscopic left hemihepatectomy, two resections of segment 3, and one resection of segment 4. Results One patient required a blood transfusion. The mean operation time was 180 min (range, 120-300 min), and the median hospital stay was 3 days (range, 1-5 days). No patient had postoperative signs of liver failure or bile leakage. No postoperative mortality was observed. Conclusion The main advantage of the intrahepatic Glissonian procedure over other techniques is the possibility of gaining a rapid and precise access to the left Glissonian sheaths facilitating left hemihepatectomy, bisegmentectomy 2-3, and individual resections of segments 2, 3, and 4. The authors believe that the intrahepatic Glissonian technique facilitates laparoscopic liver resection and may increase the development of segment-based laparoscopic liver resection.
Resumo:
Background: In view of conflicting neuroimaging results regarding autonomic-specific activity within the anterior cingulate cortex (ACC), we investigated autonomic responses to direct brain stimulation during sterecitactic limbic surgery. Methods: Skin conductance activity and accelerative heart rate responses to multi-voltage stimulation of the ACC (n = 7) and paralimbic subcauclate (n = 5) regions were recorded during bilateral anterior cingulotomy and bilateral subcauclate tractotomy (in patients that had previously received an adequate lesion in the ACC), respectively. Results: Stimulations in both groups were accompanied by increased autonomic arousal. Skin conductance activity was significantly increased during ACC stimulations compared with paralimbic targets at 2 V (2.34 +/- .68 [score in microSiemens +/- SE] vs. .34 +/- .09, p = .013) and 3 V (3.52 +/- .86 vs. 1.12 +/- .37, p = .036), exhibiting a strong ""voltage-response"" relationship between stimulus magnitude and response amplitude (difference from 1 to 3 V = 1.15 +/- .90 vs. 3.52 +/- .86, p = .041). Heart rate response was less indicative of between-group differences. Conclusions: This is the first study of its kind aiming at seeking novel insights into the mechanisms responsible for central autonomic modulation. It supports a concept that interregional interactions account for the coordination of autonomic arousal.
Resumo:
BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)
Resumo:
Solid pseudopapillary neoplasm of the pancreas is an uncommon but distinctive pancreatic neoplasm with low metastatic potential [1]. Therefore, whenever feasible, an organ-preserving operation should be performed. As previously reported, women with solid pseudopapillary neoplasm of the pancreas may be best treated by more conservative procedures [2]. Recently, laparoscopic pancreatic resections became more common and are being performed in highly specialized centers. There are only six cases of laparoscopic resection for solid pseudopapillary neoplasm of pancreas published in the English literature and, to our knowledge, laparoscopic resection of uncinate process of the pancreas has never been reported [3-6]. This video demonstrates the technical aspects of a totally laparoscopic resection of the uncinate process of the pancreas in a patient with solid pseudopapillary neoplasm. A 26-year-old woman with a 4-cm solid pseudopapillary pancreatic neoplasm was referred for surgical treatment. According to preoperative echoendoscopy, there was a safe margin between neoplasm and main pancreatic duct. The patient was placed in supine position with the surgeon standing between her legs. Four trocars, one 10-mm and three 5-mm, were used. At inspection, the inferior vena cava, transverse colon, duodenum, and pancreas are clearly identified. A Kocher maneuver was performed with complete exposure of pancreatic head and uncinate process. The uncinate process was dissected from the superior mesenteric vein and venous branches were divided between metallic clips or by use of laparoscopic coagulation shears (LCS; Ethicon Endo Surgery Industries, Cincinnati, OH, USA). Blood supply of the duodenum was preserved by ligature of small pancreatic branches from inferior pancreatoduodenal artery. Transection of pancreatic parenchyma was performed using laparoscopic coagulation shears, which is an effective tool for cutting the pancreas [7, 8]. Surgical specimen was removed through a suprapubic incision inside a retrieval bag. A hemostatic absorbable tissue (Surgicel; Ethicon Inc., Cincinnati, OH) was placed in the cutting pancreatic surface, and one round 19F Blake abdominal drain (Ethicon) was left in place. Operative time was 180 minutes and blood loss estimated in 40 ml with no blood transfusion. Hospital stay was 4 days. The patient did not have postoperative pancreatitis or pancreatic leakage, and the abdominal drain was removed on the tenth postoperative day. Final pathology confirmed the diagnosis of solid pseudopapillary neoplasm of pancreas with free surgical margins. The patient was well and asymptomatic 2 months after the procedure. Laparoscopic resection of uncinate process of the pancreas is safe and feasible and should be considered for patients suffering from pancreatic neoplasms.
Resumo:
Objective To delineate the effects of extracorporeal bypass on biomarkers of hemostasis, fibrinolysis, and inflammation and clinical sequelae. Methods Patients were assigned prospectively and randomly to either on-pump (n=41) or off-pump (n=51) coronary bypass surgery. The concentrations of C-reactive protein, fibrinogen, D-dimer, and plasminogen activator inhibitor type-1 in blood were quantified before and after (1 and 24 h) surgery. Similar surgical and anesthetic procedures were used for both groups. Clinical events were assessed during initial hospitalization and at the end of I year. Results The concentrations of plasminogen activator inhibitor type-1 and D-dimer were greater compared with preoperative values 1 and 24 h after surgery in both groups, but their concentrations increased to a greater extent 24 h after surgery in the on-pump group (P<0.01). The concentration of C-reactive protein did not change appreciably immediately after surgery in either group but increased in a parallel manner 24 h after either on-pump or off-pump surgery (P<0.01). Bypass surgery in the on-pump group was associated with greater blood loss during surgery and more bleeding after surgery (P <= 0.01). The incidence of all other complications was similar in the two groups. Conclusion On-pump surgery was associated with biochemical evidence of a prothrombotic state early after surgery but no greater incidence of thrombotic events was observed. The prothrombotic state might be a consequence of extracorporeal bypass, compensation in response to more bleeding, or both in patients undergoing on-pump surgery. Coron Artery Dis 20:100-105 (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Resumo:
Experience with laparoscopic liver resections has increased in recent years, and so have the number of patients operated on by minimally invasive techniques. Specimen extraction is an important step of laparoscopic liver resection. The size of the specimen, is Usually a limitation for the use Of laparoscopy. The aim of this paper is to describe a new technique combining Pfannenstiel suprapubic incision and obstetric forceps to remove a large specimen from laparoscopic liver resections. The present technique allows an expeditious extraction of intact specimens, even huge ones, through a standard suprapubic Pfannenstiel incision. This technique has additional functional and cosmetic advantages over other techniques of specimen retrieval. We believe that the described technique is feasible, can be easily and rapidly performed, and facilitates laparoscopic liver resection by reducing the technical difficulties for specimen removal and may also be used in other abdominal laparoscopic interventions that deal with large surgical specimens.
Resumo:
Bisegmentectomy 7-8 is feasible even in the absence of a large inferior right hepatic vein. To our knowledge, this operation has never been performed by laparoscopy. This study was designed to present video of pure laparoscopic bisegmentectomy 7-8 and bisegmentectomy 2-3 in one-stage operation for bilateral liver metastasis. A 67-year-old man with metachronous bilobar colorectal liver metastasis was referred for surgical treatment after neoadjuvant chemotherapy. CT scan disclosed two liver metastases: one located between segments 7 and 8 and another one in segment 2. At liver examination, another metastasis was found on segment 3. We decided to perform a bisegmentectomy 7-8 along with bisegmentectomy 2-3 in a single procedure. The operation began with mobilization of the right liver with complete dissection of retrohepatic vena cava. Inferior right hepatic vein was absent. Right hepatic vein was dissected and encircled. Upper part of right liver, containing segment 7 and 8, was marked with cautery. Selective hemi-Pringle maneuver was performed and right hepatic vein was divided with stapler. At this point, liver rotation to the left allowed direct view and access to the superior aspect of the right liver. Liver transection was accomplished with harmonic scalpel and endoscopic stapling device. Bisegmentectomy 2-3 was performed using the intrahepatic Glissonian approach. The specimens were extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 240 minutes with no need for transfusion. Recovery was uneventful. Patient was discharged on the fifth postoperative day. Patient is well with no evidence of disease 14 months after liver resection. Tumor markers are within normal range. Bisegmentectomy 7-8 may increase resectability rate in patients with bilateral lesions. This operation can be performed safely by laparoscopy. Preservation of segments 5 and 6 permitted simultaneous resection of segments 2 and 3 with adequate liver remnant.
Resumo:
Objective: To analyze the prognostic effect of epidermal growth factor receptor (EGFR), matrix metalloproteinases 2 and 9, and vascular endothelial growth factor expression in patients with locally recurrent oral carcinoma after salvage surgery. Design: Retrospective cohort study. Settings: Tertiary center cancer hospital. Patients: The charts of 111 patients with local recurrence of oral carcinomas were retrospectively analyzed. The previous treatment consisted of surgery in 33 patients (30.0%), radiotherapy with or without chemotherapy in 46 patients (41.0%), and surgery with adjuvant radiotherapy in 32 patients (29.0%). The expression of EGFR, matrix metalloproteinases 2 and 9, and vascular endothelial growth factor was analyzed with a tissue microarray immunohistochemical technique. Main Outcome Measures: Overall survival and cancer-specific survival (CSS). Results: The recurrences were diagnosed in less than 1 year in 69 patients (62.2%) and in more than 1 year in 42 patients (37.8%). The prognosis was worse in the group with the disease-free interval of less than 1 year (P=.01). Patients with more advanced disease (clinical stage of recurrence, III/IV) had worse rates of CSS (P=.04). Cases that were positive for EGFR had a 3-year CSS of 27.2%, while EGFR-negative cases had a 3-year CSS of 64.3% (P=.001). The expression of matrix metalloproteinases 2 (P=.83) and 9 (P=.15) and vascular endothelial growth factor (P=.86) was not significant in this group. In multivariate analysis, only the disease-free interval and the overexpression of EGFR were associated with a higher risk of cancer death. Conclusions: Local recurrence in oral carcinomas carries a poor prognosis. A disease-free interval of more than 1 year and a EGFR-negative expression are the main prognostic factors related to better CSS in patients treated with salvage surgery.
Resumo:
Experience with advanced techniques has increased the indications for laparoscopic liver resection. This video demonstrates technical aspects of a pure laparoscopic mesohepatectomy using intrahepatic Glissonian technique. To the best of our knowledge, this is the first case of anatomic laparoscopic mesohepatectomy using the Glissonian approach published in the English literature. A 62-year-old man with colorectal liver metastasis occupying central liver segments was referred for surgical treatment. The first step is the control of segment 4 pedicle. Using the round ligament as a guide, one incision is performed on its right margin and another is made at the bottom of segment 4. A vascular clamp is introduced through those incisions to occlude segment 4 Glissonian sheath. The next step is to control the right anterior pedicle. The first incision is made in front of the hilum and another is performed on the right edge of gallbladder bed. Laparoscopic clamp is introduced through these incisions and closed producing ischemic discoloration of segments 5 and 8. Vascular clamp is replaced by an endoscopic vascular stapling device and stapler is fired. Line of liver transection is marked along the liver surface following ischemic area. Liver transection is accomplished with bipolar vessel sealing device and endoscopic stapling device as appropriate. Specimen was extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 200 min with minimum blood loss and no need for blood transfusion. Recovery was uneventful, and the patient was discharged on the fifth postoperative day. Histological examination revealed clear surgical margins. Mesohepatectomy can be safely performed laparoscopically in selected patients and by surgeons with expertise in both liver surgery and laparoscopic techniques. The use of the intrahepatic Glissonian approach may help to identify the exact limits of the mesohepatectomy to avoid ischemic injury of the remnant liver.
Resumo:
Background Facial motor evoked potential (FMEP) amplitude ratio reduction at the end of the surgery has been identified as a good predictor for postoperative facial nerve outcome. We sought to investigate variations in FMEP amplitude and waveform morphology during vestibular schwannoma (VS) resection and to correlate these measures with postoperative facial function immediately after surgery and at the last follow-up. Methods Intraoperative orbicularis oculi and oris muscles FMEP data from 35 patients undergoing surgery for VS resection were collected, then analysed by surgical stage: initial, dural opening, tumour dissection (TuDis), tumour resection (TuRes) and final. Findings Immediately after surgery, postoperative facial function correlated significantly with the FMEP amplitude ratio during TuDis, TuRes and final stages in both the orbicularis oculi (p = 0.003, 0.055 and 0.028, respectively) and oris muscles (p = 0.002, 0.104 and 0.014, respectively). At the last follow-up, however, facial function correlated significantly with the FMEP amplitude ratio only during the TuDis (p = 0.005) and final (p = 0.102) stages for the orbicularis oris muscle. At both time points, postoperative facial paresis correlated significantly with FMEP waveform deterioration in orbicularis oculi during the final stage (immediate, p = 0.023; follow-up, p = 0.116) and in orbicularis oris during the TuDis, TuRes and final stages (immediate, p = 0.071, 0.000 and 0.001, respectively; follow-up, p = 0.015, 0.001 and 0.01, respectively). Conclusions FMEP amplitude ratio and waveform morphology during VS resection seem to represent independent quantitative parameters that can be used to predict postoperative facial function. Event-to-baseline FMEP monitoring is quite useful to dictate when intraoperative changes in surgical strategy are warranted to reduce the chances of facial nerve injury.
Resumo:
Purpose: The objective of this study was to evaluate the postoperative quality of life (QOL) experienced among a group of 1167 patients who underwent video-assisted thoracoscopic sympathectomy (VATS) to treat primary hyperhidrosis, as compared with the presurgical QOL. Methods: Between February 2002 and June 2007, 1167 patients who had undergone VATS were surveyed. The majority had presented with palmar hyperhidrosis (794 patients; 68%), while 340 (29%) had presented with axillary hyperhidrosis. Based on data obtained from the QOL protocol applied to all of the patients preoperatively, the patients were divided into two groups according to the level of their QOL: group 1 consisted of 312 patients (27%) with poor QOL and group 2 of 855 patients (73%) with very poor QOL. The same protocol was applied postoperatively, and five different levels of satisfaction were obtained. The same parameters were evaluated for both the palmar and the axillary hyperhidrosis subgroups. Results: The patients with very poor QOL had much better results in terms of improvement in QOL than did those with poor QOL ( P < .05). The same result was observed for both the palmar and. axillary hyperhidrosis subgroups (P < .05). Conclusion: The worse the preoperative QOL among patients undergoing sympathectomy to treat primary hyperhidrosis is, the better the postoperative improvement in QOL will be. (J Vase Surg 2010;51:1190-4.)
Resumo:
The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.