929 resultados para LIQUID-LIQUID EXTRACTION


Relevância:

70.00% 70.00%

Publicador:

Resumo:

An LC-MS/MS method has been developed for the determination of efavirenz (EFZ) in human plasma using hydrochlorothiazide as internal standard (I.S.). An ESI negative mode with multiple reaction-monitoring was used monitoring the transitions m/z 313.88→69.24 (EFZ) and 296.02→204.76 (I.S.). Samples were extracted using liquid-liquid extraction. The total run time was 2.0 min. The separation was achieved with HPLC-RP using a monolithic column. The assay was linear in the concentration range of 100 - 5000 ng mL-1. The mean recovery was 83%. Intra- and inter-day precision were < 9.5% and < 8.9%, respectively and accuracy was in the range ± 8.33%. The method was successfully applied to a bioequivalence study.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A high performance liquid chromatographic-diode array detection method for the determination of busulfan in plasma was developed and validated. Sample preparation consisted of protein precipitation followed by derivatization with sodium diethyldithiocarbamate and liquid-liquid extraction with methyl-tert-butyl ether. Chromatograms were monitored at 277 nm. Separation was carried out on a Lichrospher RP 18 column (5 µm, 250 x 4 mm). The mobile phase consisted of water and acetonitrile (20:80, v/v). The method presented adequate specificity, linearity, precision and accuracy and allowed reliable determination of busulfan in clinical plasma samples, being applied to three patients submitted to bone marrow transplantation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study optimized and validated the liquid-liquid extraction technique with partition at low temperature (LLE-PLT) for identification and quantification of four pesticides (chlorpyrifos, λ-cyhalothrin, permethrin, bifenthrin) in water samples. Analyses were performed by HPLC-UV. The technique was efficient for pesticide recovery with extraction exceeding 86%. Chromatographic response was linear for the four compounds in the 10-45 µg L-1 range, with correlation coefficients greater than 0.99. Limits of detection and quantitation were less than 3.5 µg L-1 and equal to 10 µg L-1, respectively. The proposed method was applied to 29 water samples from the Jaíba Project in northern Minas Gerais.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Topiramate and the other frequently co-administered antiepileptic drugs carbamazepine, phenytoin and phenobarbital were determined in 100 µL plasma samples by gas chromatography with nitrogen phosphorus detection (GC-NPD), after a one-step liquid-liquid extraction with ethyl acetate, followed by flash methylation with trimethylphenylammonium hydroxide. Total chromatographic run time was 12.5 min. Intra-assay and inter-assay precision was 2.5-7.3% and 1.6-5.2%, respectively. Accuracy was 100.1-104.2%. The limit of quantitation was 1 µg mL-1 for all analytes, proving suitable for routine application in therapeutic drug monitoring of antiepileptic drugs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper describes a three-week mini-project for an Experimental Organic Chemistry course. The activities include N-C cross-coupling synthesis of N-(4-methoxyphenyl) benzamide in an adapted microwave oven by a copper catalyst (CuI). Abilities and concepts normally present in practical organic chemistry courses are covered: use of balances, volumetric glassware, separation of mixtures (liquid-liquid extraction and filtration), chromatographic techniques, melting point determination and stoichiometric calculations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Difenoconazole residues in strawberry fruit cultivated in pots were estimated using the solid-liquid extraction with low temperature partition (SLE/LTP) method for sample preparation and gas chromatography with electron capture detection (GC/ECD) for analysis. The optimized method presented excellent recovery values from fortified samples and reproducibility (average recovery values ≥ 98%; CV values < 15%). Linearity of response was demonstrated (r = 0.995) with a detection limit of 9 µg kg-1. The method was successfully applied for the determination of difenoconazole residues in strawberries. Based on these results, the fungicide dissipates quickly, but the residual concentration increases after multiple applications.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of this study was to optimize and validate a solid-liquid extraction method with low-temperature partitioning (SLE/LTP) for the analysis of pesticides. This method was coupled with gas chromatography (GC/ECD) and used to evaluate the degradation of bifenthrin and pirimiphos-methyl in maize grains on exposure to ozone. The optimized SLE/LTP-GC/ECD method is simple, effective and consumes low quantities of the solvent. It can be routinely used for the determination of bifenthrin and pirimiphos-methyl in maize samples. The use of this method of analysis determined that the levels of the insecticides in maize grains were reduced on exposure of the grains to the ozone gas. The observed reduction in the levels of insecticide was directly proportional to the increase in the concentration of the ozone gas.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this study, a method of solid-liquid extraction and purification at low temperature (SLE-PLT) to determine 16 polycyclic aromatic hydrocarbons (PAHs) in sewage sludge was optimized and validated. The analyses were performed by HPLC-UV. The extraction phase, homogenization procedure, influence of pH, ionic strength and clean-up of the extracts were optimized. Recoveries were higher than 63.4% for 11 PAHs. The correlation coefficients were greater than 0.99 and limits of detection and quantitation were less than 0.060 and 0.15 µg g-1, respectively. These values were lower than the maximum residue limits of PAHs established by European legislation. SLE-PLT proved a more practical, economical method with fewer steps compared to Soxhlet extraction (reference method) for PAHs in sewage sludge.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this work was to study four different solvent mixtures intended to increase the yield of the extraction stage of clavulanic acid (CA), which is one of the steps in the purification process. Four central composite rotatable designs (CCRD) were utilized to optimize the solvent mixtures. The variables selected for the factorial design were solvent mixture ratio (mL/mL) and temperature (ºC). The results showed that the yield of CA extracted from fermentation broth with the solvent mixtures of methyl-ethyl-ketone and ethyl acetate, and methyl-isobutyl-ketone and ethyl acetate (44.7 and 50.0%, respectively) was higher than that of the individual ethyl acetate alone (36.5%).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AbstractA device comprising a lab-made chamber with mechanical stirring and computer-controlled solenoid valves is proposed for the mechanization of liquid-liquid extractions. The performance was demonstrated by the extraction of ethanol from biodiesel as a model of the extraction of analytes from organic immiscible samples to an aqueous medium. The volumes of the sample and extractant were precisely defined by the flow-rates and switching times of the valves, while the mechanic stirring increased interaction between the phases. Stirring was stopped for phase separation, and a precise time-control also allowed a successful phase separation (i.e., the absence of the organic phase in the aqueous extract). In the model system, a linear response between the analytical response and the number of extractions was observed, indicating the potential for analyte preconcentration in the extract. The efficiency and reproducibility of the extractions were demonstrated by recoveries of ethanol spiked to biodiesel samples within 96% and 100% with coefficients of variation lower than 3.0%.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, we used an aqueous two-phase system (ATPS) consisting of the ionic liquid [C4mim][Cl] and the salt K2HPO4 to partition α-lactalbumin, β-lactoglobulin, and lactoferrin whey proteins. Extraction efficiency values above 87% indicate that the proteins primarily migrated to the ionic liquid-rich phase (top phase). Partition coefficient values ranged from 6.17 to 8.93 for a-lactalbumin, from 22.80 to 34.55 for β-lactoglobulin, and from 26.46 to 40.06 for lactoferrin. Therefore, the saline ATPS with the ionic liquid examined in this study can be considered to be a promising alternative for extracting whey proteins.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The goal of this work was to develop a simple and rapid preparation method for patulin analysis in apple juice without previous clean-up. This method combined sonication and liquid extraction techniques and was used for determination of patulin in 37 commercial apple juices available on the market in the South of Brazil. The method performance characteristics were determined using a sample obtained in a local market fortified at five concentration levels of patulin and done in triplicates. The coefficient of variation for repeatability at the fortification level of 20.70µg.L-1 was 3.53 % and the recovery 94.63 %, respectively. The correlation coefficient was 0.9996 and agrees with the requirements for a linear analytical method value. The detection limit was 0.21µg.L-1 and the quantification limit 0.70 µg.L-1. Only three of the analyzed samples were upper the allowed level of 50.00 µg.L-1 recommended for the World Health Organization.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Carboxylic acids are commonly used organic acids and have many applications in industries producing food and pharmaceutical products, surfactants and detergents. Especially formic, acetic, propionic and butyric acid are important organic chemicals. These compounds can be found in many side streams and plant effluents. Recovery costs of carboxylic acids are high when they are removed from dilute solution. Conventional processes for the recovery of carboxylic acids from aqueous solutions are classical distillation or extractive distillation, azeotropic distillation or liquid-liquid extraction. The literature part of this Master’s of Science Thesis comprises possible extractants in liquid-liquid extraction of carboxylic acids from aqueous solutions and methods for their regeneration form the extract. The experimental part of this Thesis investigates liquid-liquid extraction of carboxylic acids from aqueous solutions. The aim of this work was to find a suitable extractant for liquid-liquid extraction and suitable process conditions to recover carboxylic acids from aqueous solutions. Also, back extraction of carboxylic acids and their thermal decomposition in relation to distillation of were. Experiments showed that there is more than one possible extractant for liquid-liquid extraction of carboxylic acids. Results also showed that it is possible to separate carboxylic acids and regenerate all the used extractants by vacuum distillation at suitable temperature.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Lignoselluloosasta koostuvasta biomassasta valmistetaan hydrolysoimalla sokereita, jotka jatkojalostetaan fermentoimalla bioetanoliksi. Bioetanolia käytetään fossiilisten polttoaineiden korvaajana esimerkiksi ajoneuvoissa. Bioetanolin valmistuksessa pyritään mahdollisimman hyvään saantoon, jotta sen valmistus olisi taloudellisesti kannattavaa. Hydrolyysin aikana syntyy sokerien lisäksi orgaanisia happoja, furaanin johdannaisia sekä fenolisia yhdisteitä. Yleisimpiä syntyviä yhdisteitä ovat muun muassa etikkahappo, furfuraali ja hydroksimetyylifurfuraali. Nämä yhdisteet haittaavat sokerien fermentointiprosessia ja pienentävät etanolin saantoa. Fermentointiprosessia haittaavien yhdisteiden poistoon hydrolysaattiliuoksesta voidaan käyttää esimerkiksi haihdutusta, membraanierotusta, adsorptiota, saostusta, sekä uuttoa. Tämän työn tarkoituksena oli tutkia leikkaussekoittimen soveltuvuutta biomassahydrolysaatin epäpuhtauksien erotukseen. Lisäksi kirjallisuusosassa on esitetty hydrolysointiprosessissa syntyviä haitta-aineita ja niiden erotusmenetelmiä.