972 resultados para LC-PDA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid method was developed for determination of 8 carbamate insecticides and 10 of their metabolites in apples, pears, and lettuce by liquid chromatography with UV diode array detector. With this method no derivatization is needed. Carbamates not belonging to the N-methylcarbamate class and metabolites without the N-methyl group can also be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automated on-line solid phase extraction procedure followed by liquid chromatography with diode array detection was investigated for the determination of different classes of pesticides in water samples containing varied amount of humic substances. The different pesticides used were: carbendazin, carbofuran, atrazine, diuron, propanil, molinate, alachlor, parathion-ethyl, diazinon, trifluralin and the degradation products deisopropylatrazine and deethylatrazine. Humic substances extracted from a Brazilian sediment were used from 5 to 80 mg/l and their influence on recoveries was evaluated in neutral and acidic media. Recoveries higher than 70% were obtained for all the pesticides, from the preconcentration of 75 mi of aqueous sample fortified at 2 ng/ml using precolumns packed with PLRP-S. Good recoveries were obtained at neutral pH for most of the analytes up to 40 mg/l of humic acid. Only at 80 mg/l the recoveries were significantly affected, both at acidic and neutral pH. The method was applied to the determination of pesticides in river water spiked at 0.1 to 1 ng/ml. Detection limits obtained for water containing 10 mg/l of humic acid were between 0.05 and 0.3 ng/ml.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative method using liquid chromatography with UV detection for the determination of prochloraz as 2,4,6-trichlorophenol in mango, papaya and orange is described. Ethyl acetate, acetone and dichloromethane were tested for extraction of prochloraz from the fruits. After extraction the residue of prochloraz was derivatized with pyridine hydrochloride. The analysis was carried out using liquid chromatography with UV detection and gas chromatography with electron-capture detection. Average recoveries of prochloraz from spiked fruits (0.1 and 0.2 mg kg-1) ranged from 80% to 94% with relative standard deviations between 5.6% and 12.6% (n=8). Detection and quantification limits were 0.05 and 0.1 mg kg-1, respectively. The LC-UV method was applied to mango and papaya samples submitted to dip treatment with a prochloraz formulation under laboratory conditions. In addition, fruit samples obtained from local markets were analysed. ©2005 Sociedade Brasileira de Química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative HPLC-UV and LC-MS/MS studies of impurity profiles of a reference sample (Xenical®, F. Hoffmann-La Roche Ltd., Switzerland) vs. generic (Lipiblock®, EMS-Sigma Pharma, a generic drug) were carried out with ethanol extracts of commercial samples. The generic formulation contained higher levels of common impurities as well as a considerable number of impurities not found in the reference product. The detected impurity profile of Lipiblock® revealed that it most likely is based on fermentation. Since the effect of the impurities is unknown, at this point fully synthetic Xenical® appears to offer a better safety margin than Lipiblock® which, however, compares quite well to other generic formulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of tigecycline in lyophilized powder. The LC method was conducted on a Luna C18 column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of buffer containing sodium phosphate monobasic (0.015M) and oxalic acid (0.015M) (pH 7.0)-acetonitrile (75:25, v/v), run at a flow rate of 1.0 mL/min and using ultraviolet detection at 280 nm. The chromatographic separation was obtained with a retention time of 8.6 min, and was linear in the range of 40-100 μg/mL (r2 = 0.9997). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed no interference of the excipients. The accuracy was 99.01% with a bias lower than 1.81%. The limits of detection and quantitation were 1.67 and 5.05 μg/mL, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the lyophilized powder formulation, contributing to improve the quality control and to assure the therapeutic efficacy. © The Author [2012]. Published by Oxford University Press. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)