970 resultados para Iterative Methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS We compared weighted volume CT dose index (CTDIvol) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS CTDIVol of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. METHODS AND RESULTS: In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P < 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P < 0.0001) while the stent length was decreased (-4.7 ± 0.9%,

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To determine the image quality of an iterative reconstruction (IR) technique in low-dose MDCT (LDCT) of the chest of immunocompromised patients in an intraindividual comparison to filtered back projection (FBP) and to evaluate the dose reduction capability. MATERIALS AND METHODS 30 chest LDCT scans were performed in immunocompromised patients (Brilliance iCT; 20-40 mAs; mean CTDIvol: 1.7 mGy). The raw data were reconstructed using FBP and the IR technique (iDose4™, Philips, Best, The Netherlands) set to seven iteration levels. 30 routine-dose MDCT (RDCT) reconstructed with FBP served as controls (mean exposure: 116 mAs; mean CDTIvol: 7.6 mGy). Three blinded radiologists scored subjective image quality and lesion conspicuity. Quantitative parameters including CT attenuation and objective image noise (OIN) were determined. RESULTS In LDCT high iDose4™ levels lead to a significant decrease in OIN (FBP vs. iDose7: subscapular muscle 139.4 vs. 40.6 HU). The high iDose4™ levels provided significant improvements in image quality and artifact and noise reduction compared to LDCT FBP images. The conspicuity of subtle lesions was limited in LDCT FBP images. It significantly improved with high iDose4™ levels (> iDose4). LDCT with iDose4™ level 6 was determined to be of equivalent image quality as RDCT with FBP. CONCLUSION iDose4™ substantially improves image quality and lesion conspicuity and reduces noise in low-dose chest CT. Compared to RDCT, high iDose4™ levels provide equivalent image quality in LDCT, hence suggesting a potential dose reduction of almost 80%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES In this phantom CT study, we investigated whether images reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) with reduced tube voltage and current have equivalent quality. We evaluated the effects of different acquisition and reconstruction parameter settings on image quality and radiation doses. Additionally, patient CT studies were evaluated to confirm our phantom results. METHODS Helical and axial 256 multi-slice computed tomography scans of the phantom (Catphan(®)) were performed with varying tube voltages (80-140kV) and currents (30-200mAs). 198 phantom data sets were reconstructed applying FBP and IR with increasing iterations, and soft and sharp kernels. Further, 25 chest and abdomen CT scans, performed with high and low exposure per patient, were reconstructed with IR and FBP. Two independent observers evaluated image quality and radiation doses of both phantom and patient scans. RESULTS In phantom scans, noise reduction was significantly improved using IR with increasing iterations, independent from tissue, scan-mode, tube-voltage, current, and kernel. IR did not affect high-contrast resolution. Low-contrast resolution was also not negatively affected, but improved in scans with doses <5mGy, although object detectability generally decreased with the lowering of exposure. At comparable image quality levels, CTDIvol was reduced by 26-50% using IR. In patients, applying IR vs. FBP resulted in good to excellent image quality, while tube voltage and current settings could be significantly decreased. CONCLUSIONS Our phantom experiments demonstrate that image quality levels of FBP reconstructions can also be achieved at lower tube voltages and tube currents when applying IR. Our findings could be confirmed in patients revealing the potential of IR to significantly reduce CT radiation doses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To investigate whether the effects of hybrid iterative reconstruction (HIR) on coronary artery calcium (CAC) measurements using the Agatston score lead to changes in assignment of patients to cardiovascular risk groups compared to filtered back projection (FBP). MATERIALS AND METHODS 68 patients (mean age 61.5 years; 48 male; 20 female) underwent prospectively ECG-gated, non-enhanced, cardiac 256-MSCT for coronary calcium scoring. Scanning parameters were as follows: Tube voltage, 120 kV; Mean tube current time-product 63.67 mAs (50 - 150 mAs); collimation, 2 × 128 × 0.625 mm. Images were reconstructed with FBP and with HIR at all levels (L1 to L7). Two independent readers measured Agatston scores of all reconstructions and assigned patients to cardiovascular risk groups. Scores of HIR and FBP reconstructions were correlated (Spearman). Interobserver agreement and variability was assessed with ĸ-statistics and Bland-Altmann-Plots. RESULTS Agatston scores of HIR reconstructions were closely correlated with FBP reconstructions (L1, R = 0.9996; L2, R = 0.9995; L3, R = 0.9991; L4, R = 0.986; L5, R = 0.9986; L6, R = 0.9987; and L7, R = 0.9986). In comparison to FBP, HIR led to reduced Agatston scores between 97 % (L1) and 87.4 % (L7) of the FBP values. Using HIR iterations L1 - L3, all patients were assigned to identical risk groups as after FPB reconstruction. In 5.4 % of patients the risk group after HIR with the maximum iteration level was different from the group after FBP reconstruction. CONCLUSION There was an excellent correlation of Agatston scores after HIR and FBP with identical risk group assignment at levels 1 - 3 for all patients. Hence it appears that the application of HIR in routine calcium scoring does not entail any disadvantages. Thus, future studies are needed to demonstrate whether HIR is a reliable method for reducing radiation dose in coronary calcium scoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to directly compare metal artifact reduction (MAR) of virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (CT) with iterative MAR (iMAR) from single energy in pelvic CT with hip prostheses. MATERIALS AND METHODS A human pelvis phantom with unilateral or bilateral metal inserts of different material (steel and titanium) was scanned with third-generation dual-source CT using single (120 kVp) and dual-energy (100/150 kVp) at similar radiation dose (CT dose index, 7.15 mGy). Three image series for each phantom configuration were reconstructed: uncorrected, VME, and iMAR. Two independent, blinded radiologists assessed image quality quantitatively (noise and attenuation) and subjectively (5-point Likert scale). Intraclass correlation coefficients (ICCs) and Cohen κ were calculated to evaluate interreader agreements. Repeated measures analysis of variance and Friedman test were used to compare quantitative and qualitative image quality. Post hoc testing was performed using a corrected (Bonferroni) P < 0.017. RESULTS Agreements between readers were high for noise (all, ICC ≥ 0.975) and attenuation (all, ICC ≥ 0.986); agreements for qualitative assessment were good to perfect (all, κ ≥ 0.678). Compared with uncorrected images, VME showed significant noise reduction in the phantom with titanium only (P < 0.017), and iMAR showed significantly lower noise in all regions and phantom configurations (all, P < 0.017). In all phantom configurations, deviations of attenuation were smallest in images reconstructed with iMAR. For VME, there was a tendency toward higher subjective image quality in phantoms with titanium compared with uncorrected images, however, without reaching statistical significance (P > 0.017). Subjective image quality was rated significantly higher for images reconstructed with iMAR than for uncorrected images in all phantom configurations (all, P < 0.017). CONCLUSIONS Iterative MAR showed better MAR capabilities than VME in settings with bilateral hip prosthesis or unilateral steel prosthesis. In settings with unilateral hip prosthesis made of titanium, VME and iMAR performed similarly well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on an order-theoretic approach, we derive sufficient conditions for the existence, characterization, and computation of Markovian equilibrium decision processes and stationary Markov equilibrium on minimal state spaces for a large class of stochastic overlapping generations models. In contrast to all previous work, we consider reduced-form stochastic production technologies that allow for a broad set of equilibrium distortions such as public policy distortions, social security, monetary equilibrium, and production nonconvexities. Our order-based methods are constructive, and we provide monotone iterative algorithms for computing extremal stationary Markov equilibrium decision processes and equilibrium invariant distributions, while avoiding many of the problems associated with the existence of indeterminacies that have been well-documented in previous work. We provide important results for existence of Markov equilibria for the case where capital income is not increasing in the aggregate stock. Finally, we conclude with examples common in macroeconomics such as models with fiat money and social security. We also show how some of our results extend to settings with unbounded state spaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a remote sensing observational method for the measurement of the spatio-temporal dynamics of ocean waves. Variational techniques are used to recover a coherent space-time reconstruction of oceanic sea states given stereo video imagery. The stereoscopic reconstruction problem is expressed in a variational optimization framework. There, we design an energy functional whose minimizer is the desired temporal sequence of wave heights. The functional combines photometric observations as well as spatial and temporal regularizers. A nested iterative scheme is devised to numerically solve, via 3-D multigrid methods, the system of partial differential equations resulting from the optimality condition of the energy functional. The output of our method is the coherent, simultaneous estimation of the wave surface height and radiance at multiple snapshots. We demonstrate our algorithm on real data collected off-shore. Statistical and spectral analysis are performed. Comparison with respect to an existing sequential method is analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes new approaches to improve the local and global approximation (matching) and modeling capability of Takagi–Sugeno (T-S) fuzzy model. The main aim is obtaining high function approximation accuracy and fast convergence. The main problem encountered is that T-S identification method cannot be applied when the membership functions are overlapped by pairs. This restricts the application of the T-S method because this type of membership function has been widely used during the last 2 decades in the stability, controller design of fuzzy systems and is popular in industrial control applications. The approach developed here can be considered as a generalized version of T-S identification method with optimized performance in approximating nonlinear functions. We propose a noniterative method through weighting of parameters approach and an iterative algorithm by applying the extended Kalman filter, based on the same idea of parameters’ weighting. We show that the Kalman filter is an effective tool in the identification of T-S fuzzy model. A fuzzy controller based linear quadratic regulator is proposed in order to show the effectiveness of the estimation method developed here in control applications. An illustrative example of an inverted pendulum is chosen to evaluate the robustness and remarkable performance of the proposed method locally and globally in comparison with the original T-S model. Simulation results indicate the potential, simplicity, and generality of the algorithm. An illustrative example is chosen to evaluate the robustness. In this paper, we prove that these algorithms converge very fast, thereby making them very practical to use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fully 3D iterative image reconstruction algorithm has been developed for high-resolution PET cameras composed of pixelated scintillator crystal arrays and rotating planar detectors, based on the ordered subsets approach. The associated system matrix is precalculated with Monte Carlo methods that incorporate physical effects not included in analytical models, such as positron range effects and interaction of the incident gammas with the scintillator material. Custom Monte Carlo methodologies have been developed and optimized for modelling of system matrices for fast iterative image reconstruction adapted to specific scanner geometries, without redundant calculations. According to the methodology proposed here, only one-eighth of the voxels within two central transaxial slices need to be modelled in detail. The rest of the system matrix elements can be obtained with the aid of axial symmetries and redundancies, as well as in-plane symmetries within transaxial slices. Sparse matrix techniques for the non-zero system matrix elements are employed, allowing for fast execution of the image reconstruction process. This 3D image reconstruction scheme has been compared in terms of image quality to a 2D fast implementation of the OSEM algorithm combined with Fourier rebinning approaches. This work confirms the superiority of fully 3D OSEM in terms of spatial resolution, contrast recovery and noise reduction as compared to conventional 2D approaches based on rebinning schemes. At the same time it demonstrates that fully 3D methodologies can be efficiently applied to the image reconstruction problem for high-resolution rotational PET cameras by applying accurate pre-calculated system models and taking advantage of the system's symmetries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a technique to reconstruct the electromagnetic properties of a medium or a set of objects buried inside it from boundary measurements when applying electric currents through a set of electrodes. The electromagnetic parameters may be recovered by means of a gradient method without a priori information on the background. The shape, location and size of objects, when present, are determined by a topological derivative-based iterative procedure. The combination of both strategies allows improved reconstructions of the objects and their properties, assuming a known background.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Las enfermedades no transmisibles provocan cada ano 38 millones de fallecimientos en el mundo. Entre ellas, tan solo cuatro enfermedades son responsables del 82% de estas muertes: las enfermedades cardiovasculares, las enfermedades crónicas respiratorias, la diabetes, y el cáncer. Se prevé que estas cifras aumenten en los próximos anos, ya que las tendencias indican que en el año 2030 las muertes por esta causa ascenderán a 53 millones de personas. La Organización Mundial de la Salud (OMS) considera importante buscar soluciones para afrontar esta situación y ha solicitado a los gobiernos del mundo la implementación de intervenciones para mejorar los hábitos de vida de las personas y reducir así el riesgo de desarrollo de enfermedades no trasmisibles. Cada año se producen 32 millones de infartos de miocardio y derrames celebrales, de los cuales 12.5 son mortales. En el mundo entre el 40% y 75% de la víctimas de un infarto de miocardio mueren antes de su ingreso en el hospital. En los casos que sobreviven, la adopción de un estilo de vida saludable puede evitar infartos sucesivo, y supone un ahorro potencial de 6 billones de euros al año. La rehabilitación cardiaca es un programa individualizado que aplica un método multidisciplinar para ayudar al paciente a recuperar su condición física, a gestionar la enfermedad cardiovascular y sus comorbilidades, a adoptar hábitos de vida saludables, y a promover su salud mental. La rehabilitación cardiaca requiere la total involucración y motivación del paciente, solo de esta manera se podrán promover hábitos saludables y mejorar la gestión y prevención de su enfermedad. Aunque la participación en los programas de rehabilitación cardiaca es baja, hoy en día existen programas de rehabilitación cardiaca que el paciente puede realizar en su casa. Estos suponen una solución prometedora para aumentar la participación. La rehabilitación cardiaca se considera una intervención integral donde los modelos de psicología de la salud son aplicados para promover un cambio en el estilo de vida de las personas así como para ayudarles a afrontar su propia enfermedad. Existen métodos para implementar cambios de hábitos y de aptitud, y también se considera muy relevante promover no solo el bienestar físico sino también el mental. Existen tecnologías que promueven los cambios de comportamientos en los seres humanos. En concreto, las tecnologías persuasivas y los sistemas de apoyo al cambio de comportamientos modelan las características, las estrategias y los métodos de diseño para promover cambios usando la tecnología. Pero estos modelos tienen algunas limitaciones: todavía no se ha definido que rol tienen las emociones en el cambio de comportamientos y como traducir los métodos de la psicología de la salud en la tecnología. Esta tesis se centra en tres elementos que tienen un rol clave en los cambios de hábitos y actitud: el estado físico, el estado mental, y la tecnología. -Estado de salud: un estado de salud critico puede modificar la actitud del ser humano respecto al cambio. A la vez un buen estado de salud hace que la necesidad del cambio sea menos percibida. -Estado emocional: la actitud tiene un componente afectivo. Los estados emocionales negativos pueden reducir la habilidad de una persona para adoptar nuevos comportamientos. La salud mental es la situación ideal donde los individuos tienen predisposición a los cambios. La tecnología puede ayudar a las personas a adoptar nuevos hábitos, así como a mantener una salud física y mental. Este trabajo de investigación se centra en el diseño de tecnologías para la mejora del estado físico y emocional de las personas. Se ha propuesto un marco de diseño llamado “Well.Be.Sign”. El marco se basa en tres aspectos: El marco teórico: representa los elementos que se tienen que definir para diseñar tecnologías para promover el bienestar de las personas. -El diagrama de influencia: presenta las fuerzas de ‘persuasión’ en el contexto de la salud. El rol de las tecnologías persuasivas ha sido contextualizado en una dimensión donde otros elementos influencian el usuario.  El proceso de diseño: describe el proceso de diseño utilizando una metodología iterativa e incremental que aplica una combinación de métodos de diseño existentes (Diseño Orientado a Objetivos, Diseño de Sistemas Persuasivos) así como elementos originales de este trabajo de investigación. Los métodos se han aplicados para diseñar un sistema que ofrezca un programa de tele-rehabilitación cardiaca. Inicialmente se ha diseñado un prototipo de acuerdo con las necesidades del usuario. En segundo lugar, el prototipo se ha extendido especificando la intervención requerida para al programa de rehabilitación cardiaca. Finalmente el sistema se ha desarrollado y validado en un ensayo clínico con grupo control, donde se observaron las variaciones del estado cardiovascular, el nivel de conocimiento acerca de la enfermedad, la percepción de la enfermedad, la persistencia de hábitos saludables, y la aceptabilidad del sistema. Los resultados muestran que el grupo de intervención tiene una superior capacidad cardiovascular, mejor conocimiento acerca de la enfermedad, y más percepción de control de la enfermedad. Asimismo, en algunos casos se ha registrado persistencia de los hábitos de ejercicios 6 meses después del uso del sistema. Otros dos estudios se han presentado para demonstrar la relevancia del estado emocional del usuario en el diseño de aplicaciones para la promoción del bienestar.  En personas con una grave enfermedad crónica como la insuficiencia cardiaca, donde se ha presentado las conexiones entre estado de salud y estado emocional. En el estudio se ensena la relaciones que tienen los síntomas y las emociones negativas y como un estado negativo emocional puede empeorar la condición física del paciente. -Personas con trastornos del humor: el estudio muestra como las emociones pueden tener un impacto en la percepción de la tecnología por parte del usuario. ABSTRACT Noncommunicable diseases (NCDs) cause the death of 38 million people every year. Four major NCDs are responsible for 82% of these deaths: cardio vascular disease, chronic respiratory disease, diabetes and cancer. These pandemic numbers are projected to raise to 53 million deaths in 2030, and for this reason the assembly of the World Health Organization (WHO) considers communicable diseases as an urgent need to be addressed. It is also a trend to advocate the adoption of mobile technology to deliver health services and to promote healthy behaviours among citizens, but adopting healthS promoting lifestyle is still a difficult task facing human tendencies. Within this context, there is a promising opportunity: persuasive technologies. These technologies are intentionally designed to change a person’s attitudes or behaviours; when applied in this context, than can be used to change health-related attitudes, beliefs, and behaviours. Each year there are 32 million heart attacks and strokes globally, of which about 12.5 million are fatal. Worldwide between 40 and 75% of all heart-attack victims die before reaching hospital. Avoiding a second heart attack by improving adherence to lifestyle and medication regimens has a cost saving potential of around €6 billion per year. In most of the cases the cardiovascular event has been provoked by unhealthy lifestyle. Furthermore, after an MI event the patient's decision to adopt or not healthier behaviour will influence the progress of the disease. Cardio-rehabilitation is an individualized program that follows a multidisciplinary approach to support the user to recover from the Myocardial Infarction, manage the Cardio Vascular Disease and the comorbidities, adopt healthy habits, and cope with any emotional distress. Cardio- rehabilitation requires patient participation and willingness to perform behavioral modifications and change the attitude toward the management and prevention of the disease. Participation in the Cardio Rehabilitation program is not high; the home-based rehabilitation program is a promising solution to increase participation. Nowadays cardio rehabilitation is considered a comprehensive intervention in which models of health psychology are applied to promote the behaviour change of the individuals. Relevant methods that have been successfully applied to foster healthy habits include the Health Belief Model and the Trans Theoretical Model. Studies also demonstrate the importance to promote not only the physical but also the mental well being of the individuals. The idea of also promoting behaviour change using technologies has been defined by the literature as persuasive technologies or behaviour change support systems, in which the features, the strategies and the design method have been modelled to foster the behaviour change using technology. Limitations have been found in this model: there is still research to be done on the role of the emotions and how psychological health intervention can be translated into computer methods. This research focuses on three elements that could foster behaviour change in individuals: the physical and emotional status of the person, and the technology. Every component can influence the user's attitude and behaviour in the following ways: ' Physical status: bad physical status could change human attitude toward the necessity to adopt health behaviours; at the same time, good health status reduces the need to adopt healthy habits. ' Emotional status: the attitude has an affective component, negative emotional state can reduce the ability of a person to adopt new behaviours, and mental well being is the ideal situation in which individuals have a predisposition to adopt healthy behaviours. ' Technology: it can help users to adopt new behaviours and can also be support to promote physical and emotional status. Following this approach the idea driven in this research is that technology that is designed to improve the physical status and the emotional status of the individual could better foster behaviour change. According to this principle, the Well.Be.Sign framework has been proposed. The framework is based on three views: ' The theoretical framework: it represents the patterns that have to be defined to design the technologies to promote well being. ' The influence diagram: it shows the persuasive forces in the context of health care. The role of the persuasive technologies is contextualized in a wider universe where other factors and persuasive forces influence a patient. ' The design process: it shows the process of design using an iterative, incremental methodology that applies a combination of existing methodologies (Goal Directed Design and Persuasive System Design) and others that are original to this research. The methods have been applied to design a system to deliver cardio rehabilitation at home: first a prototype has been defined according to the user’s needs, then it has been extended with the specific intervention required for the cardio–rehabilitation, finally the system has been developed and validated in a controlled clinical study in which the cardiovascular fitness, the level of knowledge, the perception of the illness, the persistence of healthy habits and the system acceptance (only the intervention group) were measured. The results show that the intervention group increased cardiovascular capacity, knowledge, feeling of control of illness and perceived benefits of exercise at the end of the study. After six months of the study, a followSup of the exercise habits was performed. Some individuals of the intervention group continued to be engaged in the running exercise sessions promoted in the designed system. Two other cases have been presented to demonstrate the foundations of the Well.Be.Sign’s approach to promote both physical and emotional status: ' People affected by Heart Failure, in which a bidirectional connection between health status and emotions has been discussed with patients. Two correlations were demonstrated: the relationship between symptoms and negative emotional response, and that negative emotional status is correlated with worsening of chronic conditions. ' People with mood disorders: the study shows that emotions could also impact how the user perceives the technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel protein superfamily with over 600 members was discovered by iterative profile searches and analyzed with powerful bioinformatics and information visualization methods. Evidence exists that these proteins generate a radical species by reductive cleavage of S-adenosylmethionine (SAM) through an unusual Fe-S center. The superfamily (named here Radical SAM) provides evidence that radical-based catalysis is important in a number of previously well- studied but unresolved biochemical pathways and reflects an ancient conserved mechanistic approach to difficult chemistries. Radical SAM proteins catalyze diverse reactions, including unusual methylations, isomerization, sulfur insertion, ring formation, anaerobic oxidation and protein radical formation. They function in DNA precursor, vitamin, cofactor, antibiotic and herbicide biosynthesis and in biodegradation pathways. One eukaryotic member is interferon-inducible and is considered a candidate drug target for osteoporosis; another is observed to bind the neuronal Cdk5 activator protein. Five defining members not previously recognized as homologs are lysine 2,3-aminomutase, biotin synthase, lipoic acid synthase and the activating enzymes for pyruvate formate-lyase and anaerobic ribonucleotide reductase. Two functional predictions for unknown proteins are made based on integrating other data types such as motif, domain, operon and biochemical pathway into an organized view of similarity relationships.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Iterative Closest Point algorithm (ICP) is commonly used in engineering applications to solve the rigid registration problem of partially overlapped point sets which are pre-aligned with a coarse estimate of their relative positions. This iterative algorithm is applied in many areas such as the medicine for volumetric reconstruction of tomography data, in robotics to reconstruct surfaces or scenes using range sensor information, in industrial systems for quality control of manufactured objects or even in biology to study the structure and folding of proteins. One of the algorithm’s main problems is its high computational complexity (quadratic in the number of points with the non-optimized original variant) in a context where high density point sets, acquired by high resolution scanners, are processed. Many variants have been proposed in the literature whose goal is the performance improvement either by reducing the number of points or the required iterations or even enhancing the complexity of the most expensive phase: the closest neighbor search. In spite of decreasing its complexity, some of the variants tend to have a negative impact on the final registration precision or the convergence domain thus limiting the possible application scenarios. The goal of this work is the improvement of the algorithm’s computational cost so that a wider range of computationally demanding problems from among the ones described before can be addressed. For that purpose, an experimental and mathematical convergence analysis and validation of point-to-point distance metrics has been performed taking into account those distances with lower computational cost than the Euclidean one, which is used as the de facto standard for the algorithm’s implementations in the literature. In that analysis, the functioning of the algorithm in diverse topological spaces, characterized by different metrics, has been studied to check the convergence, efficacy and cost of the method in order to determine the one which offers the best results. Given that the distance calculation represents a significant part of the whole set of computations performed by the algorithm, it is expected that any reduction of that operation affects significantly and positively the overall performance of the method. As a result, a performance improvement has been achieved by the application of those reduced cost metrics whose quality in terms of convergence and error has been analyzed and validated experimentally as comparable with respect to the Euclidean distance using a heterogeneous set of objects, scenarios and initial situations.